• 제목/요약/키워드: behavior of failure

검색결과 3,187건 처리시간 0.031초

유리섬유 보강패널로 보강된 철근콘크리트 슬래브의 구조거동에 관한 연구 (Structural Behavior of R/C Slabs Strengthened by Glass Fiber Reinforced Plastic-Panels)

  • 김우;김행준;이성문
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2000년도 봄 학술발표회 논문집
    • /
    • pp.751-756
    • /
    • 2000
  • The structural behavior of reinforced concrete slabs strengthened by glass fiber reinforced plastic-panels experimentally investigated. The experimental variables are strengthening length, strengthening width, and pre-crack existence. The pre-cracked slabs are initially loaded to 70 percent of ultimate flexural capacity and subsequently repaired with GFRP-Panels bonded to the tension face of the slabs. Five one-way slabs were tested to failure. The main failure mode of strengthened slabs is separation failure by crack propagation from load point section to end of plate. The behavior of strengthened slabs is represented by a maximum load, load-deflection curves an load-strain curves.

  • PDF

LS-DYNA를 이용한 철근 콘크리트 보의 파괴 거동 해석 (Failure Behavior Analysis of R.C Beams using LS-DYNA)

  • 박건;홍기남;한상훈;권용길
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2008년도 춘계 학술발표회 제20권1호
    • /
    • pp.297-300
    • /
    • 2008
  • 본 연구는 철근 콘크리트 보의 파괴 거동을 예측하는데 있어 외연적 유한요소해석 프로그램인 LS-DYNA의 적용성을 검증하는데 주안점을 두었다. 해석 대상 철근 콘크리트 부재의 변수는 인장 철근비, 전단 철근비, 그리고 전단 스팬비를 고려하였다. 해석 결과는 본 연구에서 고려한 모든 변수의 l파괴 거동을 적절하게 예측하는 것으로 나타나 LS-DYNA는 철근콘크리트 구조물의 파괴해석을 수행 하는데 매우 유용한 것으로 평가되었다.

  • PDF

Experimental study of failure mechanisms in elliptic-braced steel frame

  • Jouneghani, Habib Ghasemi;Haghollahi, Abbas;Beheshti-Aval, S. Bahram
    • Steel and Composite Structures
    • /
    • 제37권2호
    • /
    • pp.175-191
    • /
    • 2020
  • In this article, for the first time, the seismic behavior of elliptic-braced moment resisting frame (ELBRF) is assessed through a laboratory program and numerical analyses of FEM specifically focused on the development of global- and local-type failure mechanisms. The ELBRF as a new lateral braced system, when installed in the middle bay of the frames in the facade of a building, not only causes no problem to the opening space of the facade, but also improves the structural behavior. Quantitative and qualitative investigations were pursued to find out how elliptic braces would affect the failure mechanism of ELBRF structures exposed to seismic action as a nonlinear process. To this aim, an experimental test of a ½ scale single-story single-bay ELBRF specimen under cyclic quasi-static loading was run and the results were compared with those for X-bracing, knee-bracing, K-bracing, and diamond-bracing systems in a story base model. Nonlinear FEM analyses were carried out to evaluate failure mechanism, yield order of components, distribution of plasticity, degradation of structural nonlinear stiffness, distribution of internal forces, and energy dissipation capacity. The test results indicated that the yield of elliptic braces would delay the failure mode of adjacent elliptic columns and thus, help tolerate a significant nonlinear deformation to the point of ultimate failure. Symmetrical behavior, high energy absorption, appropriate stiffness, and high ductility in comparison with the conventional systems are some of the advantages of the proposed system.

Study of compressive behavior of triple joints using experimental test and numerical simulation

  • Sarfarazi, Vahab;Wang, Xiao;Nesari, Mojtaba;Ghalam, Erfan Zarrin
    • Smart Structures and Systems
    • /
    • 제30권1호
    • /
    • pp.49-62
    • /
    • 2022
  • Experimental and discrete element methods were used to investigate the effects of triple joints lengths and triple joint angle on the failure behavior of rock mass under uniaxial compressive test. Concrete samples with dimension of 20 cm × 20 cm × 5 cm were prepared. Within the specimen, three imbedded joint were provided. The joint lengths were 2 cm, 4cm and 6 cm. In constant joint lengths, the angle between middle joint and other joints were 30°, 60°, 90°, 120° and 150°. Totally 15 different models were tested under compression test. The axial load rate on the model was 0.05 mm/min. Concurrent with experimental tests, the models containing triple joints, length and joint angle are similar to the experiments, were numerical by Particle flow code in two dimensions (PFC2D). Loading rate in numerical modelling was 0.05 mm/min. Tensile strength of material was 1 MPa. The results show that the failure behaviors of rock samples containing triple joints were governed by both of the angle and the length of the triple joints. The uniaxial compressive strengths (UCS) of the specimens were related to the fracture pattern and failure mechanism of the discontinuities. Furthermore, it was shown that the compressive behavior of discontinuities is related to the number of the induced tensile cracks which are increased by decreasing the joint length. Along with the damage failure of the samples, the acoustic emission (AE) activities are excited. There were only a few AE hits in the initial stage of loading, then AE hits rapidly grow before the applied stress reached its peak. In addition, every stress drop was accompanied by a large number of AE hits. Finally, the failure pattern and failure strength are similar in both methods i.e., the experimental testing and the numerical simulation methods.

공정성 조절효과에 따른 서비스 실패 관련 변인들 간의 관계구조분석 - 공정성 조절효과를 중심으로 - (Analysis of the Relational Structure among Service Failure-related Variables after Moderation of Fairness - Focusing on fairness-related -)

  • 김성아;유태순
    • 복식
    • /
    • 제64권3호
    • /
    • pp.13-31
    • /
    • 2014
  • This study attempts to analyze relational structures among service failure-related variables after the moderation of fairness in the beauty service industry with the following purposes: First, it aims to review and investigate service failure & service recovery strategies, non-switching intentions after recovery, revisit intention, the intent to provide word-of-mouth recommendations and previous studies on service failure and recovery in the beauty service industry. Second, it targets the analysis of the role of fairness as a variable that moderates relations between service recovery strategies and post-recovery satisfaction in the beauty service industry. For this, the following research method was used: This study has investigated the effect of service failure and its recovery strategies (behavioral recovery strategy, psychological recovery strategy, monetary recovery strategy) on customer satisfaction for beauty service users and used the Structural Equation Model (SEM) to further analyze and verify the effect of the satisfaction on post-satisfaction behavior (non-switching intention, repurchase intention and the intent to provide word-of-mouth recommendations). The SEM was divided into a measurement model and structural model to determine if the model is appropriate and estimate the parameters of the path coefficient. In addition, this study examined to see if fairness (procedural fairness, distributive fairness and interactive fairness) works as a moderating variable while the service recovery efforts affect customer satisfaction. Then, the role of service recovery strategies, targeted to satisfy the customers who were dissatisfied because of service failure, were investigated. In addition, its effect on post-satisfaction behavior was analyzed from the structural aspect, and the moderating role was examined as well. Then, the role of the service recovery strategy, which can be used to satisfy dissatisfied customers, was examined, and the effect of the satisfaction on customer behavior was analyzed from a structural perspective. In addition, the moderating role of fairness was tested. As a result, this study is significant in that it helps service providers formulate service recovery-related strategies.

Flexural performance of composite sandwich wall panels with foamed concrete

  • Lei Li;Wei Huang;Zhengyi Kong;Li Zhang;Youde Wang;Quang-Viet Vu
    • Steel and Composite Structures
    • /
    • 제52권4호
    • /
    • pp.391-403
    • /
    • 2024
  • The flexural behavior of composite sandwich wall panels with different thicknesses, numbers of holes, and hole forms, and arrangement form of longitudinal steel bar (uniform type and concealed-beam type) are investigated. A total of twelve composite sandwich wall panels are prepared, utilizing modified polystyrene particles mixed with foam concrete for the flexural performance test. The failure pattern of the composite sandwich wall panels is influenced by the extruded polystyrene panel (XPS) panel thickness and the reinforcement ratio in combination, resulting in both flexural and shear failure modes. Increasing the XPS panel thickness causes the specimens to transition from flexural failure to shear failure. An increase in the reinforcement ratio leads to the transition from flexural failure to shear failure. The hole form on the XPS panel and the steel bar arrangement form affect the loading behavior of the specimens. Plum-arrangement hole form specimens exhibit lower steel bar strain and deflection compared to linear-arrangement hole form specimens. Additionally, specimens with concealed beam-type steel bar display lower steel bar strain and deflection than uniform-type steel bar specimens. However, the hole form and steel bar arrangement form have a limited impact on the ultimate load. Theoretical formulas for cracking load are provided for both fully composite and non-composite states. When compared to the experimental values, it is observed that the cracking load of the specimens with XPS panels closely matches the calculations for the non-composite state. An accurate prediction model for the ultimate load of fully composite wall panels is developed. These findings offer valuable insights into the behavior of composite sandwich wall panels and provide a basis for predicting their performance under various design factors and conditions.

Riprap으로 보강된 농업용 저수지 제체의 붕괴거동 (Behavior of Failure on Agricultural Reservoirs Embankment by Riprap Reinforcement Method)

  • 이달원;노재진
    • 한국농공학회논문집
    • /
    • 제56권6호
    • /
    • pp.63-73
    • /
    • 2014
  • In this study, the large scale test was performed to investigate the behavior of failure on the embankment and spillway transitional zone by overtopping. The pore water pressure, earth pressure, settlement and failure behaviors according to several reinforcing method were compared and analyzed. The pore water pressure showed a small change in the spillway transition zone and core, indicating that the riprap and geotextile efficiently reinforced the embankment, but non-reinforcement showed a largely change in pore water pressure. The earth pressure by riprap and geotextile at upstream slope and bottom core increased rapidly with the infiltration of the pore water by overtopping. And the earth pressure at crest showed a smally change due to effect of the inclined core. A settlement by riprap showed a small change and the geotextile decreased a rapidly due to failure of crest. The width of failure by riprap at intermediate stage (50 min) showed a largely due to sliding of crest. But, the width and depth of the seepage erosion after the intermediate overtopping period (100 min) were very small due to the effect of riprap than geotextile and non-reinforcement which delayed failure. It has the effect that protect reservoir embankment from erosion in the central part. The pore water pressure at the spillway transition zone due to overtopping increased a rapidly in the case of non-reinforcement, but the reinforced methods by geotextile and riprap showed a smally change. Therefore, the reinforced method by riprap and geotextile was a very effective method to protect permanently and the emergency an embankment due to overtopping, respectively.

Compressive behavior of built-up open-section columns consisting of four cold-formed steel channels

  • Shaofeng, Nie;Cunqing, Zhao;Zhe, Liu;Yong, Han;Tianhua, Zhou;Hanheng, Wu
    • Steel and Composite Structures
    • /
    • 제45권6호
    • /
    • pp.907-929
    • /
    • 2022
  • Compression experiments were conducted to investigate the compressive behavior of built-up open-section columns consisting of four cold-formed steel channels (BOCCFSs) of different lengths, thicknesses, and cross-section sizes (OB90 and OB140). The load-displacement curves, failure modes, and maximum compression strength values were analyzed in detail. The tests showed that the failure modes of the OB90 specimens transformed from a large deformation concentration induced by local buckling to flexural buckling with the increase in the slenderness ratio. The failure modes of all OB140 specimens were deformation concentration, except for one long specimen, whose failure mode was flexural buckling. When the slenderness ratios of the specimens were less than 55, the failure modes were controlled by local buckling. Finite element models were built using ABAQUS software and validated to further analyze the mechanical behavior of the BOCCFSs. A parametric study was conducted and used to explore a wide design space. The numerical analysis results showed that when the screw spacing was between 150 mm and 450 mm, the difference in the maximum compression strength values of the specimens was less than 4%. The applicability and effectiveness of the design methods in Chinese GB50018-2002 and AISI-S100-2016 for calculating the compression strength values of the BOCCFSs were evaluated. The prediction methods based on the assumptions produced predictions of the strength that were between 33% to 10% conservative as compared to the tests and the finite element analysis.

보강된 복합적층 패널의 좌굴 및 좌굴후 거동의 형상 최적설계에 관한 연구 (A Study on Shape Optimization for Buckling and Postbuckling Behavior of Stiffened Laminated Composite Panels)

  • 이광록;정기현;허성필;양원호;조명래
    • 대한기계학회논문집A
    • /
    • 제25권1호
    • /
    • pp.106-114
    • /
    • 2001
  • In this study, a shape optimization of stiffener was conducted to increase buckling load or failure load in each case with a different design value and a different objective function for stiffened laminated composite panel of I-type under compression loading. Regarding each of buckling load or failure load as objective function, optimum design was carried out. In respect of optimum design, the effects of relative length of web and cab of stiffener on buckling load or failure load of postbuckling were investigated.

FRP 바닥판의 약축방향 파괴모드에 관한 연구 (A Study on the Failure Mode of FRP Bridge Deck in It's Weak Axis)

  • 김병민;황윤국;이영호;강영종;지광습
    • 한국전산구조공학회논문집
    • /
    • 제19권1호
    • /
    • pp.73-83
    • /
    • 2006
  • 본 논문에서는 내구성과 수명을 획기적으로 향상시키기 위해 제3세대 건설재료인 섬유강화 플라스틱(FRP) 소재로 제작된 사각형 중공 교량 바닥판의 파괴모드를 실험과 해석을 통해 분석하였다. 재하시험 결과 바닥판의 강축방향의 거동은 파괴 직전까지도 거의 선형탄성적으로 거동한 반면, 약축방향의 거동은 재하초기부터 작은 하중하에서도 큰 비선형성을 보였다. 이 약축방향 비선형성의 원인은 웨브와 플랜지 연결부의 불완전한 일체거동으로 인한 소성거동 때문인 것으로 판단된다. 웨브와 플랜지의 연결부에 소성힌지를 도입한 간단한 구조모델을 이용하여 이를 확인하였다. 접착부의 박리 파괴 가능성도 검토하였으나 이는 대상 중공바닥판의 약축방향 파괴에 직접적으로 관여하는 것은 아닌 것으로 판단된다 약축방향의 구조거동을 개선시키기 위한 방안으로 내부를 폼으로 충전하는 방법을 제시하였으며 그 가능성을 구조해석을 통해 확인하였다.