• Title/Summary/Keyword: behavior of chlorine

Search Result 58, Processing Time 0.024 seconds

Preparation and Characterization of ClO2 Self-Releasing Smart Sachet (이산화염소 자체 방출 스마트 샤쉐의 제조 및 특성 연구)

  • Junseok Lee;Hojun Shin;Sadeghi Kambiz;Jongchul Seo
    • KOREAN JOURNAL OF PACKAGING SCIENCE & TECHNOLOGY
    • /
    • v.29 no.1
    • /
    • pp.1-7
    • /
    • 2023
  • Chlorine dioxide (ClO2) is widely used for post-harvest sterilization treatment. However, there are limitations in the retail application of ClO2 due to difficulties in handling, expensive facilities, and safety concerns. Therefore, it is necessary to develop a ClO2 technology that can be easily applied and continuously released for a long period. In this study, a series of ClO2 self-releasing sachets were developed. First, poly(ether-block-amide) (PEBAX) and polyethylene-glycol (PEG) composite films containing different ratios of citric acid (CA) were prepared using the solution casting method. The as-prepared PEBAX/PEG-CA composite films were evaluated using FT-IR, DSC, and TGA to confirm chemical structure and thermal properties. Subsequently, PEBAX/PEG-CA composite films were designed in the form of a sachet and NaClO2 powder was transferred into the sachet to achieve a ClO2 self-releasing system. The ClO2-releasing behavior of the sachet was investigated by measuring the release amount of the gas using UV-vis. The release amount of ClO2 increased with increasing CA contents owing to the existence of higher protons (trigger) in the polymer matrix. Further, ClO2 gas was released for a longer time. Therefore, the as-prepared smart sachet can be tuned according to applications and packaging sizes to serve an optimal sterilization effect.

An Experimental Study on Corrosion Behavior in Steel of Concrete Applied with Arc Metal Spray Method Surface Treatment Technology Using EIS (EIS를 이용한 아크 금속용사 표면처리기법이 적용된 강재의 콘크리트 내 부식 거동에 관한 실험적 연구)

  • Yoon, Chang-Bok;Park, Jang hyun;Lee, Han-Seung
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.24 no.3
    • /
    • pp.87-95
    • /
    • 2020
  • As an experimental study on the corrosion behavior of steel materials to which ATMS method using EIS was applied in concrete, immersion of Ca(OH)2 saturated aqueous solution and NaCl aqueous solution simulating the environment inside concrete The corrosion behavior was tested. The equivalent circuit was derived through the analysis of the Nyquist plot, and the interfacial resistance and the polarization resistance of the Ca(OH)2 aqueous solution were compared, and Al ATMS was the best interfacial resistance and Zn ATMS was the best polarization resistance. After burying ATMS steel material of cement mortar, the initial immersion impedance measurement value was the highest in the Zn ATMS test body in the impedance measurement by the immersion time by immersing it in the NaCl aqueous solution. Al ATMS test piece has the highest impedance and is highly reliable. This is because Al, which has a high ionization tendency, is continuously oxidized in a strong alkaline environment to form a film and protect the steel from permeation of chlorine ions.

Corrosion effects on mechanical behavior of steel fiber reinforced concrete, including fibers from recycled tires

  • Ansari, Mokhtar;Safiey, Amir
    • Computers and Concrete
    • /
    • v.26 no.4
    • /
    • pp.367-375
    • /
    • 2020
  • Today, the use of special technologies in the admixture of concrete has made tremendous progress, but the problem that has always existed in the construction of concrete members is the brittleness and lack of loading bearing after cracking, which leads to reduced strength and energy absorption. One of the best ways to fix this is to reinforce the concrete with steel fibers. Steel fibers also control cracks due to dry shrinkage, reduce structural crack width, and improve impact resistance. In this study, recycled steel fibers from worn tires have been used in the manufacture of concrete samples, the secondary benefits of which are the reduction of environmental pollution. One of the disadvantages of steel fiber reinforced concrete is the corrosion of steel fibers and their deterioration in harsh environments such as coastal areas. Corrosion caused by chlorine ions in metal fibers causes deterioration and early decommissioning of structures in corrosive environments. In this study, the effect of the dosage of steel fibers (dosages of 15, 30, and 45 kg of fibers per cubic meter of concrete) and aspect ratio of fibers (aspect ratio of 25 and 50) on compressive and flexural strength of concrete samples are investigated. In the following, the effect of fiber corrosion on the results of the mechanical properties of concrete samples is examined. The results show that the increase in fiber causes a relative increase in compressive strength, and a significant increase in flexural strength, and corrosion of steel fibers without reducing workability reduces compressive strength and flexural strength by up to 6 to 11%, respectively.

Surface Segregation of Hydroniums and Chlorides in a Thick Ice Film at Higher Temperatures

  • Lee, Du Hyeong;Bang, Jaehyeock;Kang, Heon
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.02a
    • /
    • pp.263-263
    • /
    • 2013
  • This work examines the dynamic properties of ice surfaces in vacuum for the temperature range of 140~180 K, which extends over the onset temperatures for ice sublimation and the phase transition from amorphous to crystallization ice. In particular, the study focuses on the transport processes of excess protons and chloride ions in ice and their segregative behavior to the ice surface. These phenomena were studied by conducting experiments with a relatively thick (~100 BL) ice film constructed with a bottom $H_2O$ layer and an upper $D_2O$ layer, with excess hydronium and chloride ions trapped at the $H_2O$/$D_2O$ interface as they were generated by the ionization of hydrogen chloride. The migration of protons, chloride ions, and water molecules to the ice film surface and their H/D exchange reactions were measured as a function of temperature using the methods of low energy sputtering (LES) and Cs+ reactive ion scattering (RIS). Temperature programmed desorption (TPD) experiments monitored the desorption of water and hydrogen chloride from the surface. Our observations indicated that both hydronium and chloride ions migrated from the interfacial layer to segregate to the surface at high temperature. Hydrogen chloride gas desorbs via recombination reaction of hydronium and chloride ions floating on the surface. Surface segregation of these species is driven by thermodynamic potential gradient present near the ice surface, whereas in the bulk, their transport is facilitated by thermal diffusion process. The finding suggests that chlorine activation reactions of hydrogen chloride for polar stratospheric ice particles occur at the surface of ice within a depth of at most a few molecular layers, rather than in the bulk phase.

  • PDF

Preparation of Disulfonated Poly(arylene ether sulfone) Random Copolymer Thin Film Composite Membranes Using a Benign Solvent (친환경용매 기반의 술폰화 폴리아릴렌 에테르 술폰 랜덤 공중합체 Thin Film Composite 제조)

  • Lee, Chang Hyun;McGrath, James E.;Freeman, Benny
    • Membrane Journal
    • /
    • v.24 no.4
    • /
    • pp.292-300
    • /
    • 2014
  • Chlorine-resistant sulfonated poly(arylene ether sulfone) random copolymer (SPAES)-thin film composite (TFC) membranes for desalination are prepared using monoglyme as a selective solvent, which dissolves SPAES, but should be inert to porous polysulfone layer (e.g., Udel$^{(R)}$). Different from formic acid and diethylene glycol used as other selective solvents, monoglyme is environmentally friendly and has much lower boiling temperature. After a pretreatment of Udel$^{(R)}$ support film in isopropyl alcohol-glycerine mixture to minimize pore penetration leading to fairly reduced water flux, coating of SPAES solution in monoglyme onto the support and stepwise drying processes are conducted for defect-free TFC formation. The transport behavior through SPAES-TFC membranes is observed, correlating with the effects of sulfonation level, protonation, and physical and chemical crosslinking of SPAES selective layers.

The Research Trend and Social Perceptions Related with the Tap Water in South Korea (수돗물 이용에 대한 국내 연구동향과 사회적 인식)

  • Kim, Ji Yoon;Do, Yuno;Joo, Gea-Jae;Kim, Eunhee;Park, Eun-Young;Lee, Sang-Hyup;Baek, Myeong Su
    • Korean Journal of Ecology and Environment
    • /
    • v.49 no.3
    • /
    • pp.208-214
    • /
    • 2016
  • We analyzed research trend and public perception related with tap water to identify major factors affecting low consumption of tap water. 805 research articles were collected for text mining analysis and 1,000 on-line questionnaires were surveyed to find social variables influencing tap water intake. Based on the word network analysis, research topics were divided into 4 major categories, 1) drinking water quality, 2) water fluoridation, 3) residual chlorine, and 4) micro-organism management. Compared with these major research topics, scientific studies of drinking behavior, or social perception were rather limited. 22.4% of total respondents used tap water as drinking water source, and only 1% drank tap water without further treatments (i.e. boiling, filtering). Experience of quality control report (B=0.392, p=0.046) and level of policy trust (B=1.002, p<0.0001) were influential factors on tap water drinking behavior. Age (B=0.020, p=0.002) and gender (B= - 1.843, p<0.0001) also showed significant difference. To increase the frequency of drinking the tap water by social members, the more scientific information of tap water quality and the water policy management should be clearly shared with social members.

Effect of Repeated Wet/Dry Cycles of Salt Solution on Flexural Performance of Steel Fiber Reinforced Concrete (반복적 염수침지가 강섬유 혼입 콘크리트의 휨성능에 미치는 영향)

  • Kim, Ji-Hyun;Choi, Yu-Jin;Chung, Chul-Woo
    • Journal of the Korea Institute of Building Construction
    • /
    • v.22 no.6
    • /
    • pp.553-564
    • /
    • 2022
  • Concrete is a representative composite material that shows excellent performance in the construction field. However, it is a brittle and nonhomogeneous material and exhibits weak behavior against bending and tensile forces. To compensate for such weakens, fiber reinforcement has been utilized, and steel fiber has been recognized as one of the best material for such purpose. However, steel fiber can seriously affect the durability of concrete exposed to the marine environment due to the corrosion caused by chlorine ions. This study intended to evaluate the mechanical performance of steel fiber reinforce concrete during and after repeated wet/dry cycles in salt solution. According to the experimental results, there was no reduction in the relative dynamic modulus of concrete during the repeated wet/dry cycles in salt solution for 37 weeks. Flexural strength was not decreased after completion of repeated wet/dry cycles in salt solution. There was no sign of corrosion in steel fibers after visual observation of fractured surface. However, the flexural toughness was decreased, and this is because about half of the concrete specimen showed failure before reaching the maximum displacement of 3 mm. Although repeated wet/dry cycles in salt solution did not cause cracks in concrete through corrosion of steel fibers, specific attention is required because it can reduce flexural toughness of steel fiber reinforced concrete.

Metal Corrosion Mechanism by Sulfate-reducing and Iron-oxidizing Bacteria in Saline System and its Optimal Inactivation (염수계 철산화균 및 황환원균에 의한 금속 부식 및 최적 제어 방안)

  • Sung, Eun-Hae;Han, Ji-Sun;Kim, Chang-Gyun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.30 no.8
    • /
    • pp.798-807
    • /
    • 2008
  • Due to economic impairment derived from metal corrosion of pumping station installed around coastal area, it was needed for related cause-effect to be investigated for understanding practical corrosion behavior and providing proper control. This research was thus carried out to determine whether the microbe can influence on metal corrosion along with its control in the laboratory. For this study, groundwater was sampled from the underground pump station(i.e. I Gas Station) where corrosion was observed. Microbial diversity on the samples were then obtained by 16S rDNA methods. From this, microbial populations showing corrosion behaviors against metals were reported as Leptothrix sp.(Iron oxidizing) and Desulfovibrio sp.(Sulfur reducing) Iron oxidizing bacteria were dominantly participating in the corrosion of iron, while sulfate reducing bacteria were more preferably producing precipitate of iron. In case of galvanized steel and stainless steel, iron oxidizing bacteria not only enhanced the corrosion, but also generated its scale of precipitate. Sulfate reducing bacteria had zinc steel corroded greater extent than that of iron oxidizing bacteria. In the inactivation test, chlorine or UV exposure could efficiently control bacterial growth. However as the inactivation intensity being increased beyond a threshold level, corrosion rate was unlikely escalated due to augmented chemical effect. It is decided that microbial corrosion could be differently taken place depending upon type of microbes or materials, although they were highly correlated. It could be efficiently retarded by given disinfection practices.