• Title/Summary/Keyword: beat noise

Search Result 66, Processing Time 0.02 seconds

ft Study on the Dither Random Noise for Improving the Bias Stability of Ring Laser Gyroscope (링레이저 자이로의 바이어스 안정도 개선을 위한 몸체진동 잡음 연구)

  • Shim, Kyu-Min;Kim, Cheon-Joong
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.12 no.11
    • /
    • pp.1065-1073
    • /
    • 2006
  • In this paper we confirm the relation between the phases and phase errors of the beat signal at the lock-in region of the amplitude modulation type ring laser gyroscope by numerical calculation. Based on this facts, we, numerically, study the envelopes and magnitudes of the dither noise for statistically summing out the beat signal phase error, and we, experimently, confirm these numerical results. As a result, we find that the dither noise requires the increase gradient and the decrease gradient of the dither amplitudes, and those gradients should be combined with white noise. The magnitude of the dither noise which is satisfied with these requirements should be more than 5 percents of the average dither amplitude.

Vibration Diagnosis of High Pressure LNG Pump (고압 LNG 펌프의 진동 진단)

  • Choi, Byeong-Geun;Kim, Hak-Eun;Choi, Chang-Lim;Lee, Jae-Myeong;Bang, Sang-Su
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.05a
    • /
    • pp.776-779
    • /
    • 2005
  • Liquefied Natural Gas takes up six hundredths of the volume of natural gas, which makes storage and transportation much easier. To send out natural gas via a pipeline network across the nation, high pressure LNG pumps supply highly compressed LNG to high-pressure vaporization facilities. The Number of high Pressure LNG pumps determined the send out amount in LNG receiving terminal. So it is main equipment at LNG production process and should be maintained on best conditions. In this paper, to find out the cause of high beat vibration at cryogenic pumps, vibration and motor current analysis have been performed. And high beat vibration of cryogenic pumps could be reduced due to the modification of motor rotor.

  • PDF

Structure Excitation by Using Beating (맥놀이 현상을 이용한 구조물 진동 가진)

  • Choi, Young-Chul;Park, Jin-Ho;Yoon, Doo-Byoung
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.19 no.10
    • /
    • pp.1028-1033
    • /
    • 2009
  • To detect faults and monitor thinning on a pipe, many people use ultra sonic sensors that are operated in high frequency range. Because there are many modes in high frequency range, it is difficult to find faults and monitor pipe thinning on a structure. If we deal with signals in a low frequency range which include only A0 wave and S0 wave, the information of monitoring and diagnosis can be easily obtained. In this paper, the technique for exciting low frequency range using ultra sonic sensors is proposed. The main idea of the proposed method comes from the beat phenomenon. The beat frequency is equal to the absolute value of the difference in frequency of the two waves. If the beat frequency is tuned by two ultra waves, we can excite A0 mode and S0 mode of structures. To verify the proposed method, we have performed a steel plate and pipe experiments. Experimental results show that two ultra sonic sensors can well excite low frequency range.

A Pacemaker AutoSense Algorithm with Dual Thresholds

  • Kim, Jung-Kuk;Huh, Woong
    • Journal of Biomedical Engineering Research
    • /
    • v.23 no.6
    • /
    • pp.477-484
    • /
    • 2002
  • A pacemaker autosense algorithm with dual thresholds. one for noise or tachyarrhythmia detection (noise threshold, NT) and the other for intrinsic beat detection (sensing threshold. ST), was developed to improve the sensing performance in single pass VDD electrograms. unipolar electrograms, or atrial fibrillation detection. When a deflection in an electrogram exceeds the NT (defined as 50% of 57), the autosense algorithm with dual thresholds checks if the deflection also exceeds the ST. If it does, the autosense algorithm calculates the signal to noise ratio (SNR) of the deflection to the highest deflection detected by NT but lower than ST during the last cardiac cycle. If the SNR 2, the autosense algorithm declares an intrinsic beat detection and calculates the next ST based on the three most recent intrinsic peaks. If the SNR $\geq$2, the autosense algorithm checks the number of deflections detected by NT during the last cardiac cycle in order to determine if it is a noise detection or tachyarrhythmia detection. Usually the autosense algorithm tries to set the 57 at 37.5% of the average of the three intrinsic beats, although it changes the percentage according to event classifications. The autosense algorithm was tested through computer simulation of atrial electrograms from 5 patients obtained during EP study, to simulate a worst sensing situation. The result showed that the ST levels for autosense algorithm tracked the electrogram amplitudes properly, providing more noise immunity whenever necessary. Also, the autosense algorithm with dual thresholds achieved sensing performance as good as the conventional fixed sensitivity method that was optimized retrospectively.

Heart beat interval measurement using an IBM PC (IBM PC를 이용한 심장 박동 간격의 측정)

  • 이동하;박경수
    • Journal of the Ergonomics Society of Korea
    • /
    • v.9 no.1
    • /
    • pp.3-14
    • /
    • 1990
  • This article develops a cost-effective and accurate measurement system for heart best intervals. The system is composed of an analog to digital (A/D) converter, an IBM personal computer (an 8088 microprocessor, an 8253-5 timer, an 8259A interrupt controller, and memories) and assembler programs for controlling these hardware components. An exponential smoothing algorithm effectively reduced noise effects from A/D converted electrocardiogram (ECG) signals influenced by 60 Hz alternating current (AC). The system can collect 15000 heart beat intervals with an 1/5400 second unit.

  • PDF

Nonlinear Vibration of Running Viscoelastic Belts (구동 점탄성 벨트의 비선형진동)

  • 우영주;최연선
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.13 no.11
    • /
    • pp.845-851
    • /
    • 2003
  • The nonlinear vibration of moving viscoelastic belts excited by the eccentricity of pulleys is investigated through experimental and analytical methods. Laboratory measurements demonstrate the nonlinearities in the responses of the belt particularly in the resonance region and with the variation of tension, The measurements of the belt motion are made using noncontact laser sensors. Jump and hysteresis phenomenon are observed experimentally and were studied with a model. which considers the nonlinear relation of belt stretch. An ordinary differential equation is derived as a working form of the belt equation of motion, Numerical results show good agreements with the experimental observations, which demonstrates the nonlinearity of viscoelastic moving belts.

Development of a High-Resolution Electrocardiography for the Detection of Late Potentials (Late Potential의 검출을 위한 고해상도 심전계의 개발)

  • 우응제;박승훈
    • Journal of Biomedical Engineering Research
    • /
    • v.17 no.4
    • /
    • pp.449-458
    • /
    • 1996
  • Most of the conventional electrocardiowaphs foil to detect signals other than P-QRS-T due to the limited SNR and bandwidth. High-resolution electrocardiography(HRECG) provides better SNR and wider bandwidth for the detection of micro-potentials with higher frequency components such as vontricular late potentials(LP). We have developed a HRECG using uncorrected XYZ lead for the detection of LPs. The overall gain of the amplifier is 4000 and the bandwidth is 0.5-300Hz without using 60Hz notch filter. Three 16-bit A/D converters sample X, Y, and Z signals simultaneously with a sampling frequency of 2000Hz. Sampled data are transmitted to a PC via a DMA-controlled, optically-coupled serial communication channel. In order to further reduce the noise, we implemented a signal averaging algorithm that averaged many instances of aligned beats. The beat alignment was carried out through the use of a template matching technique that finds a location maximizing cross-correlation with a given beat tem- plate. Beat alignment error was reduced to $\pm$0.25ms. FIR high-pass filter with cut-off frequency of 40Hz was applied to remove the low frequency components of the averaged X, Y, and Z signals. QRS onset and end point were determined from the vector magnitude of the sigrlaIL and some parameters needed to detect the existence of LP were estimated. The entire system was designed for the easy application of the future research topics including the optimal lead system, filter design, new parameter extraction, etc. In the developed HRECG, without signal averaging, the noise level was less than 5$\mu$V$_rms RTI$. With signal averaging of at least 100 beats, the noise level was reduced to 0.5$\mu$V$_rms RTI$, which is low enough to detect LPs. The developed HRECG will provide a new advanced functionality to interpretive ECG analyzers.

  • PDF

A study on the dither random noise to minimize the output error of ring laser gyroscope (링레이저 자이로의 출력오차 최소화를 위한 불규칙 몸체진동잡음 연구)

  • 심규민;손승현
    • Korean Journal of Optics and Photonics
    • /
    • v.14 no.6
    • /
    • pp.649-656
    • /
    • 2003
  • In this paper we confirm the relation between the phase and phase error of the beat signal at the lock-in region of the dither type ring laser gyroscope by numerical calculation. We also study the requirement of the dither noise of an amplitude modulation type for statistical zero averaging of the beat signal phase error, without accumulation. As a result, we find that the dither noise requires the increase and decrease gradients of the dither amplitude, and those gradients should be combined with similar white noise. The slope of the gradient and maximum/minimum amplitude must be changed randomly. We confirm the error accumulation characteristic related to the dither noise by comparison of the two outputs during temperature change, by operating the two kinds dither noise, one is satisfied with the requirement and the other is not.

The Detection of PVC based Rhythm Analysis and Beat Matching (리듬분석과 비트매칭을 통한 조기심실수축(PVC) 검출)

  • Jeon, Hong-Kyu;Cho, Ik-Sung;Kwon, Hyeog-Soong
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.13 no.11
    • /
    • pp.2391-2398
    • /
    • 2009
  • Premature ventricular contractions are the most common of all arrhythmias and may cause more serious situation in some patients. Therefore, the detection of this arrhythmia becomes crucial in the early diagnosis and prevention of possible life threatening cardiac diseases. Most of the algorithms detecting PVC reported in literature is not always feasible due to the presence of noise and P wave making the detection difficult, and the process being time consuming and ineffective for real time analysis. To solve this problem, a new approach for the detection of PVC is presented based rhythm analysis and beat matching in this paper. For this purpose, the ECG signals are first processed by the usual preprocessing method and R wave was detected. The algorithm that decides beat type using the rhythm analysis of RR interval and beat matching of QRS width is developed. The performance of R wave and PVC detection is evaluated by using MIT-BIH arrhythmia database. The achieved scores indicate sensitivity of 99.74%, positive predictivity of 99.81% and sensitivity of 93.91%, positive predictivity of 96.48% accuracy respectively for R wave and PVC detection.