• Title/Summary/Keyword: beat frequency

Search Result 171, Processing Time 0.028 seconds

Analysis of Musical Characteristic Which is Liked by Variable Age Group (다양한 연령층이 좋아하는 음악특성 분석)

  • Yoon, Sang-Hoon;Kyon, Doo-Heon;Bae, Myong-Jin
    • Proceedings of the IEEK Conference
    • /
    • 2008.06a
    • /
    • pp.989-990
    • /
    • 2008
  • Most of all popular music is made by genre and specification of music according to age group. Generally Young people of $10{\sim}20$ ages like dance and techno, But old people over 40 age like trot. In this paper, we analyzed characteristic of music which people preferred by an age group. Without relevance with age, we could confirm the factor of music which popular in all age group by analyzing. The common factor of music all of age group liked are slow word, fast beat, repeated and simple melody, and characteristic of frequency in affluent middle tone.

  • PDF

Real Time W-band FMCW Distance Measuring Devices Using TMS320C6701 DSP (TMS320C6701 DSP를 이용한 실시간 W-대역 FMCW 거리측정장치)

  • Lee, Chang-Won
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.9 no.1 s.24
    • /
    • pp.109-116
    • /
    • 2006
  • This paper presents a real time distance measuring device using a W-band linear frequency modulated continuous wave(FMCW) radar and TMS320C6701 digital signal processor(DSP). We used FFT operation for measuring distance with the beat signals and the results of FFT could be converted to distance with ease. We presented how to implement a real time miniaturized hardware system including network protocols using a single DSP core. Also how to control the modulation signal of FMCW system to compensate the VCO nonlinearity using the Time Gating control of DSP is presented. We have shown that the proposed system has good performances for measuring distance in real time via outdoor environment experiments.

광섬유 레이저 센서

  • 김향균
    • Korean Journal of Optics and Photonics
    • /
    • v.4 no.4
    • /
    • pp.480-486
    • /
    • 1993
  • We propose and demanstrate a fiber laser as a sensor, whose output is the frequency of beat signals between eigenpolarization modes of the fiber laser. For the measurement of lateral stress, proportional constant of 4.8 kHz/gram is obtained with a good linearity. For the measurements of temperature and longitudinal strain applied to the polarization maintaining fiber laser, proportional constants of 30 kHz/$^{\circ}C$ -cm, and 43 kHz/${\mu}m$, respectively, are obtained.

  • PDF

FMCW RADAR SIGNAL PROCESS USING REAL FFT (Real FFT를 이용한 FMCW 레이더 신호처리)

  • Kim, Min-Joon;Cheon, I-Hwan;Kim, Ju-Hyun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.11 no.12
    • /
    • pp.2227-2232
    • /
    • 2007
  • In this paper, it is presented a Real FFT for the FMCW radar distance measurement with high resolution. The high distance resolution needs the measurement of the accurate beat frequency. To improve the distance resolution, zoom fft, decimation, digital low pass filter and zero padding method are used. The simulation results using the Matlab show ${\pm}5mm$ of distance resolution and the measuring range is up to 35meter.

Music Genre Classification Based on Timbral Texture and Rhythmic Content Features

  • Baniya, Babu Kaji;Ghimire, Deepak;Lee, Joonwhon
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2013.05a
    • /
    • pp.204-207
    • /
    • 2013
  • Music genre classification is an essential component for music information retrieval system. There are two important components to be considered for better genre classification, which are audio feature extraction and classifier. This paper incorporates two different kinds of features for genre classification, timbral texture and rhythmic content features. Timbral texture contains several spectral and Mel-frequency Cepstral Coefficient (MFCC) features. Before choosing a timbral feature we explore which feature contributes less significant role on genre discrimination. This facilitates the reduction of feature dimension. For the timbral features up to the 4-th order central moments and the covariance components of mutual features are considered to improve the overall classification result. For the rhythmic content the features extracted from beat histogram are selected. In the paper Extreme Learning Machine (ELM) with bagging is used as classifier for classifying the genres. Based on the proposed feature sets and classifier, experiment is performed with well-known datasets: GTZAN databases with ten different music genres, respectively. The proposed method acquires the better classification accuracy than the existing approaches.

A Study on the Development of Level Sensor using Frequency Modulated Continuous Wave (주파수 변조 연속파를 이용한 레벨 측정 시스템 개발에 관한 연구)

  • Park, Dong-Kook;Han, Tae-Kyoung;Park, In-Yong;Yoon, Chun-Su
    • Journal of Navigation and Port Research
    • /
    • v.28 no.6
    • /
    • pp.497-501
    • /
    • 2004
  • In this paper, it is presented a level sensor for measuring a level of the contents of cargo tank using frequency modulated continuous wave(FMCW). The frequency range is 10∼11 GHz, the radar cross section(RCS) of test target is $0.8\textrm{m}^2$ of metal plate. The experiment is performed in laboratory and open ground, the sweep time of the signal is 100 ms, the pyramidal horn antenna of about 22 dBi gain is used, and input power of antenna is about 8 dBm The beat frequency according to the target moving to 40 m is measured. There is a good agreement between measured and calculated results. But the resolution of the FMCW radar is measured about 10 cm due to nonlinear of voltage controlled oscillator(VCO).

Analysis of the Relation of the Positive Inotropic Action of Several Cardiotonics and Aconiti Tuber Butanol Fraction to the Frequency of Contraction of Heart Muscle (수축빈도에 따른 수종 강심약물 및 부자 부타놀 분획의 강심효과의 분석)

  • Lim, J.K.;Kim, M.S.;Shin, S.G.;Park, C.W.
    • The Korean Journal of Pharmacology
    • /
    • v.13 no.2
    • /
    • pp.1-9
    • /
    • 1977
  • The effects of extracellular calcium concentrations and several concentration of Aconiti tuber butanol fraction, norepinephrine, ouabain on the force of isometric contraction of isolated atrial preparations obtained from rabbits were determined at $11{\sim}14$ different frequencies of contraction. Qualitatively similar results were obtained in all preparations. In most preparations, rested-state contraction was induced at the range of $120{\sim}400$ seconds stimulation interval. Over the range of intervals from 120 to 10 seconds negative inotropic effect of activation (NIEA) was predominant, so the steady-state contractile force progressively declined. At the intervals of 3 seconds, changes in the cumulated negative and positive isotropic effect of activation (PIEA) practically cancelled each other under steady-state conditions. At the interval from 3 seconds to 0.25 seconds, the additional cumulation of PIEA was greater than that of the NIEA. When the intervals between contractions were shorter than 0.25 seconds, the cumulation of the NIEA was again predominant. The positive inotropic effect of cardiac glycoside resulted at least in large part from increase in the rested-state contraction. No significant effect on the PIEA was found. The decay of the NIEA was apparently greatly accelerated in the presence of high concentration of ouabain, but this may also be a reflection of their action on the state determining the strength of the rested-state contraction. In the case of extracellular calcium concentration increment, the similar results with the ouabain treatment were obtained. Norepinephrine produced more powerful inotropic effect at shorter stimulation interval than long. The rested-state contraction and the decay of the NIEA were not significantly altered in the presence of norepinephrine, but cumulated PIEA and the amount of PIEA produced by each contraction were significantly increased. Aconiti tuber butanol fraction showed similar results with that of norepinephrine. The increment of contractile force at various contraction frequency were dose-responsive in the presence of Aconiti tuber butanol fraction. It is suggested that the positive inotropic effect of Aconiti tuber butanol fraction at various contraction frequency may be due to increase of the cumulation of PIEA and the amount of PIEA produced by each beat.

  • PDF

A Computational Model of Cytosolic and Mitochondrial [$Ca^{2+}$] in Paced Rat Ventricular Myocytes

  • Youm, Jae-Boum;Choi, Seong-Woo;Jang, Chang-Han;Kim, Hyoung-Kyu;Leem, Chae-Hun;Kim, Na-Ri;Han, Jin
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.15 no.4
    • /
    • pp.217-239
    • /
    • 2011
  • We carried out a series of experiment demonstrating the role of mitochondria in the cytosolic and mitochondrial $Ca^{2+}$ transients and compared the results with those from computer simulation. In rat ventricular myocytes, increasing the rate of stimulation (1~3 Hz) made both the diastolic and systolic [$Ca^{2+}]$ bigger in mitochondria as well as in cytosol. As L-type $Ca^{2+}$ channel has key influence on the amplitude of $Ca^{2+}$ -induced $Ca^{2+}$ release, the relation between stimulus frequency and the amplitude of $Ca^{2+}$ transients was examined under the low density (1/10 of control) of L-type $Ca^{2+}$ channel in model simulation, where the relation was reversed. In experiment, block of $Ca^{2+}$ uniporter on mitochondrial inner membrane significantly reduced the amplitude of mitochondrial $Ca^{2+}$ transients, while it failed to affect the cytosolic $Ca^{2+}$ transients. In computer simulation, the amplitude of cytosolic $Ca^{2+}$ transients was not affected by removal of $Ca^{2+}$ uniporter. The application of carbonyl cyanide 4-(trifluoromethoxy) phenylhydrazone (FCCP) known as a protonophore on mitochondrial membrane to rat ventricular myocytes gradually increased the diastolic [$Ca^{2+}$] in cytosol and eventually abolished the $Ca^{2+}$ transients, which was similarly reproduced in computer simulation. The model study suggests that the relative contribution of L-type $Ca^{2+}$ channel to total transsarcolemmal $Ca^{2+}$ flux could determine whether the cytosolic $Ca^{2+}$ transients become bigger or smaller with higher stimulus frequency. The present study also suggests that cytosolic $Ca^{2+}$ affects mitochondrial $Ca^{2+}$ in a beat-to-beat manner, however, removal of $Ca^{2+}$ influx mechanism into mitochondria does not affect the amplitude of cytosolic $Ca^{2+}$ transients.

Respiratory Sinus Arrhythmia: Methods of Measurement and Interpretations of Tonic and Dynamic Vagal Cardiac Drive Index in Psychophysiology of Emotions

  • Estate M.Sokhadze;Lee, Jong-Mi;Park, Mi-Kyung;Sohn, Jin-Hun
    • Proceedings of the Korean Society for Emotion and Sensibility Conference
    • /
    • 2000.11a
    • /
    • pp.81-87
    • /
    • 2000
  • Beat-to-beat changes in heart period (heart period variability, HPV) are mediated by fluctuations in autonomic activity. Spectral analysis is used to quantify such fluctuations in the range of 0.15-0.40 Hz (high frequency, HF), which are influenced primarily by parasympathetic factors. These fluctuations are often referred to as RSA (respiratory sinus arrhythmia), the physiological phenomenon extracted by spectral analysis and other methods including histograms of heart rate ( HR), deviations of HR etc. Respiratory sinus arrhythmia indexing with peak-to-valley method suggested by Grossman et at., (1981) yields a simple range statistic and is quantified on breath-by-breath basis, thus being quite sensitive and less dependent on recording time as compared to spectral analysis. It is strongly recommended to use at least 1 min epoch to asses HF component of HPV and at least 2 min fer low frequency (LF) of HPV and even 5 min far valid clinical assessment. Peak-to-valley statistic is limited to RSA index only, but has its pragmatic advantages. Most important is possibility of its application far relatively small epoch analysis. We used short periods (20,30, 40 sec only) and off-line analysis of RSA using ECG and respiration curve this method of assessment and proved that this method is more practically effective. The RSA index was not so far dependent on respiration pattern differences and reflected actual vagal control of HR and were accompanied by low HR under some high stress conditions and in an aversive affective visual stimulation experiments. Another factor that might modulate cardiac chronotropic response is the interaction of sympathetic and parasympathetic inputs on sino-atrial (SA) node level, because responses to vagal influences are known to be proportional to ongoing sympathetic activity, that is so called accentuated antagonism. Since sympathetic outflow (increment of influences on SA) under negative emotions or stress was high in almost all physiological responses, vagal effects on HR could be therefore potentiated, leading to masking of output cardiac response seen in HPV, In the case of moderate sympathetic activation, on the other hand, autonomic interactions in cardiac control appear to be minimal. Thus RSA index appears to be an effective alternative method to assess and measure spectral HPV.

  • PDF

Applying of SOM for Automatic Recognition of Tension and Relaxation (긴장과 이완상태의 자동인식을 위한 SOM의 적용)

  • Jeong, Chan-Soon;Ham, Jun-Seok;Ko, Il-Ju;Jang, Dae-Sik
    • Journal of the Korea Society of Computer and Information
    • /
    • v.15 no.2
    • /
    • pp.65-74
    • /
    • 2010
  • We propose a system that automatically recognizes the tense or relaxed condition of scrolling-shooting game subject that plays. Existing study compares the changed values of source of stimulation to the player by suggesting the source, and thus involves limitation in automatic classification. This study applies SOM of unsupervised learning for automatic classification and recognition of player's condition change. Application of SOM for automatic recognition of tense and relaxed condition is composed of two steps. First, ECG measurement and analysis, is to extract characteristic vector through HRV analysis by measuring ECG after having the player play the game. Secondly, SOM learning and recognition, is to classify and recognize the tense and relaxed conditions of player through SOM learning of the input vectors of heart beat signals that the characteristic extracted. Experiment results are divided into three groups. The first is HRV frequency change and the second the SOM learning results of heart beat signal. The third is the analysis of match rate to identify SOM learning performance. As a result of matching the LF/HF ratio of HRV frequency analysis to the distance of winner neuron of SOM based on 1.5, a match rate of 72% performance in average was shown.