• 제목/요약/키워드: bearing stiffness

검색결과 917건 처리시간 0.024초

고온 초전도체를 사용한 반발식 마그네틱 베어링의 특성에 관한 실험적 연구 (An Experimental Study on the Characteristics of the Repulsive Type Magnetic Bearing System using High Temperature Superconductor)

  • 유재한;임윤철
    • 한국윤활학회:학술대회논문집
    • /
    • 한국윤활학회 1996년도 제24회 추계학술대회
    • /
    • pp.202-206
    • /
    • 1996
  • An experimental study of the characteristics of the repulsiveytype magnetic bearing using high Tc superconductor is presented. In field cooling superconductor has the position-stability due to a flux pinning effect and the strong damping due to hysterisis, while in zero field cooling it has the only strong repulsive force due to Meissner effect. Lift force in superconducting levitation has a hysterisis characteristics, and it is the dissipation of energy, the mechanism of damping. As the relative linear velocity between a magnet and a superconductor increases, the area of the hysterisis loop becomes smaller. It means the decrease of damping. In field cooling, the static stiffness is very nonlinear in smaller than initial gap, but almost linear in larger than initial gap.

  • PDF

Performance of multi-storey structures with high damping rubber bearing base isolation systems

  • Karabork, Turan
    • Structural Engineering and Mechanics
    • /
    • 제39권3호
    • /
    • pp.399-410
    • /
    • 2011
  • Base isolation, having quite simple contents, aims to protect the buildings from earthquake-induced damages by installing structural components having low horizontal stiffness between substructure and superstructure. In this study, an appropriate base isolation system for 2-D reinforced concrete frame is investigated. For different structural heights, the structural systems of 2, 3 and 4 bays are modeled by applying base isolation systems and results are compared with conventional structural systems. 1999 Marmara earthquake data is used for applying the model by time history method in SAP2000 package. Results of various parameters such as base shear force, structure drift ratio, structure period and superstructure acceleration are discussed for all models.

각접촉 볼 베어링의 정위치 예압 변화에 따른 회전체 계 동특성 변화 연구 (A Study on the dynamic characteristics of rotor systems supported by angular contact ball bearings with the axial displacement preload varied)

  • 강중옥;홍성욱
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1997년도 추계학술대회 논문집
    • /
    • pp.389-392
    • /
    • 1997
  • This paper presents the dynamic analysis and experiment for rotor systems supported by angular contact ball bearings subjected to axial displacement preload. A dynamic software, which has been developed by the authors for the analysis of rotor systems supported by angular contact ball bearings, is used to simulate a uniform shaft system supported by two angular contact ball bearings with the axial displacement preload varied. Experiments are also performed to validate the simulation. An experimental system is constructed which consists of a uniform shaft, two bearings and a device for adjusting the axial displacement preload. Through a series of simulation and experiment, the dynamic characteristics of rotor systems with angular contact ball bearings subject to axial displacement preload are investigated.

  • PDF

고속전철 교각의 강성도 산정을 위한 현장실험 (Field Test on Rigidities of Piers in High-speed Railway)

  • 진원종;곽종원;김병석;박성용
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2000년도 가을 학술발표회논문집(I)
    • /
    • pp.745-750
    • /
    • 2000
  • The rigidity of pier is important in the analysis of rail on high speed railway bridges. This study is being performed because of followings. 1) Actual longitudinal stiffness of the structure including substructure should be considered in the calculation of longitudinal stresses in rails. 2) There are many uncertainties in piers and foundations for design. 3) Actual guideline for the design of piers is necessary. 4) Measurement on the rigidity of pier according to the types of pier, foundation and soil-condition is needed. Curve for rigidity will be obtained through this study and applied for actual design as the guideline. Stresses in rails can be estimates accurately. A pair of piers, which consists of pot-bearing for fixed support and pad-bearing for movable support, is loaded by steel frame through steel wire ropes. The responses which are intended to measure in the field test are displacements, forces and tilts on the top of piers.

  • PDF

접촉결합부를 갖는 원통구조물의 열적,동적 특성 연구

  • 김선민;이선규
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1997년도 춘계학술대회 논문집
    • /
    • pp.244-249
    • /
    • 1997
  • Internal and external heat sources will cause to deform to machine elements in the contact joint of structure,which results in the change of contact pressure distribution different from initial assembly. Heat induced variations of contact pressure will change the static and dynamic properties such as contact stiffness,damping as well as contact heat conduction in the structure. In order to design and control the intelligent machine tool operating in variant conditions more sophisticatedly, the good prediction for the changes of prescribed propeties are strongly required especially in the contact elements adjacent to the rotational or linear bearing This paper presents some computational and experimental results in regard to static and dynamic characteristics of the press-fitted bush and shaft assembly which is a model of the bearing innerrace and shaft assembly. In the condition of heat generation on the outer surface of the bush,the effects of changes in the negative clearance and the heat flux on pressure distribution and dynamic properties are investigated. Results of this study show that the edge effect of the bush and the initial clearance have effects on the transient dynamic characteristics significantiy.

탄성 링을 갖는 볼 베어링 지지의 터보 펌프 임계 속도에 관한 연구 (Critical Speeds Evaluation of Turbo Pump Unit with a Elastic-ring Inserted Ball Bearing)

  • 이용복;김창호;곽현덕;하태웅;우유철
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2001년도 춘계학술대회논문집
    • /
    • pp.735-743
    • /
    • 2001
  • This study was performed to evaluate the dynamic behavior of turbo pump unit. The acceptable separate margin of 1st critical speed was obtained by the use of elastic-ring inserted ball bearing, while the poor separate margin of 1$\^$st/ critical speed was appeared in the case without the elastic-ring. In addition, the results show that the stiffness and damping of plain seals gain more separate margin of 2nd critical speed. However the wear or the failure of seals could reduce the 2$\^$nd/ critical speeds near the operating speed.

  • PDF

정밀 제진대 개발 및 동특성에 관한 실험적 연구 (Development of precision vibration isolation table and study of dynamic characteristics with experiment)

  • 김인수;김종연;한문성;김영중
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2001년도 추계학술대회논문집 I
    • /
    • pp.329-334
    • /
    • 2001
  • Recently, the high precision technology can not be developed continuously if we don't have anti vibration technology. Vibration isolation technology using an air spring and laminated robber bearing is widely used because it has excellent vibration isolation characteristics. We developed high precision vibration table with two good element(air spring and LRB) for semiconductor factory. Air Spring is used for isolating the vertical vibration and LRB is used for isolating the horizontal Vibration. As a result, It has D-Class degree in BBR-Criteria. In this paper, we talk about orifice characteristics in the self-damped air spring and design flow of the laminated robber bearing. The orifice characteristics is delicate shade of length and diameter. When we do experimentation to find orifice characteristics, length is fixed and diameter is changed. The orifice diameter is the wider and the air spring stiffness is the softer.

  • PDF

하이드레이트 함유 퇴적물의 역학적 성질 및 지구물리 특성 (Mechanical and Electrical Properties of Hydrate-bearing Sediments)

  • 이주용
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2007년도 추계학술대회 논문집
    • /
    • pp.594-596
    • /
    • 2007
  • Using an oedometer cell instrumented to measure the evolution of electromagnetic properties, small strain stiffness, and temperature, we conducted consolidation tests on four types of sediments. The tested specimens include sediments with different gas hydrate saturation at four stages of loading. The test results show that the electromagnetic and mechanical properties of hydrate-bearing marine sediments are governed by the vertical effective stress, stress history, porosity, hydrate saturation, fabric, ionic concentration of the pore fluid, and temperature. The results also show that permittivity and electrical conductivity data can be combined to estimate hydrate volume fraction in laboratory sediments, methodology that might eventually be extended for estimation of hydrate concentrations in field settings.

  • PDF

모사터빈 시험기 개발 및 기초가진 시험 (A Development of Turbine Simulator and Foundation Excitation Test)

  • 김영철;이안성;김병옥;김영춘;우성현
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2004년도 춘계학술대회논문집
    • /
    • pp.675-680
    • /
    • 2004
  • In this study, a turbine simuiator is designed and manufactured to investigate the transient response of an actual turbine. The rotor mass and bearing stiffness is reduced to 1/140 of its actual turbine. The dynamic characteristics of turbine simulator are similar to those of the actual turbine. The turbine simulator is excited by an electro-magnetic type exciter in the form of half sine wave. Duration time is con☞oiled by Sms, 10ms, and Isms, and maximum acceleration is applied by 3g. Foundation excitation test is performed in stationary condition and rotating condition(6000rpm). The test results can be used to verify the validif of the theoretical afproach for transient analysis of actual turbine.

  • PDF

축정렬 불량시 베어링 특성 변화에 따른 발전소 증기 터빈의 동특성 연구 (Study of Dynamic Characteristics of Angular Misalignment of High-pressure Turbine in 1000MW Nuclear Power Plant)

  • 손석만;이준신;유기완;이선기;김태룡
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2000년도 춘계학술대회논문집
    • /
    • pp.664-669
    • /
    • 2000
  • Angular misalignment is one of the important causes for shaft vibration of turbine-generator in 1000MW nuclear power plant. It may cause the plant unexpected shutdown and subsequent accident. The change of dynamic characteristics in journal bearing and rotor due to angular misalignment in high pressure turbine is analyzed. The stiffness/damping coefficients of journal bearing increase as angular misalignment. Subsequently the natural frequency of HP turbine is changed. It was found that the natural frequency may locate near 2 times operating frequency in case of severe misalignment.

  • PDF