• Title/Summary/Keyword: beam model

Search Result 3,455, Processing Time 0.032 seconds

Behavior of strengthened reinforced concrete coupling beams by bolted steel plates, Part 2: Evaluation of theoretical strength

  • Zhu, Y.;Su, R.K.L.
    • Structural Engineering and Mechanics
    • /
    • v.34 no.5
    • /
    • pp.563-580
    • /
    • 2010
  • Composite beams using bolts to attach steel plates to the side faces of existing reinforced concrete (RC) coupling beams can enhance both their strength and deformability. The behavior of those composite beams differs substantially from the behavior of typical composite beams made up of steel beams and concrete slabs. The former are subjected to longitudinal, vertical and rotational slips, while the latter only involve longitudinal slip. In this study, a mixed analysis method was adopted to develop the fundamental equations for accurate prediction of the load-carrying capacity of steel plate strengthened RC coupling beams. Then, a rigid plastic analysis technique was used to cope with the full composite effect of the bolt group connections. Two theoretical models for the determination of the strength of medium-length plate strengthened coupling beams based on mixed analysis and rigid plastic methods are presented. The strength of the strengthened coupling beams is derived. The vertical and longitudinal slips of the steel plates and the shear strength of the anchor-bolt connection group is considered. The theoretical models are validated by the available experimental results presented in a companion paper. The strength of the specimens predicted from the mixed analysis model is found to be in good agreement with that from the experimental results.

Low velocity impact behavior of concrete beam strengthened with CFRP strip

  • Kantar, Erkan;Anil, Ozgur
    • Steel and Composite Structures
    • /
    • v.12 no.3
    • /
    • pp.207-230
    • /
    • 2012
  • Nowadays CFRP (Carbon Fiber Reinforced Polymer) became widely used materials for the strengthening and retrofitting of structures. Many experimental and analytical studies are encountered at literature about strengthening beams by using this kind of materials against static loads and cyclic loads such as earthquake or wind loading for investigating their behavior. But authors did not found any study about strengthening of RC beams by using CFRP against low velocity impact and investigating their behavior. For these reasons an experimental study is conducted on totally ten strengthened RC beams. Impact loading is applied on to specimens by using an impact loading system that is designed by authors. Investigated parameters were concrete compression strength and drop height. Two different sets of specimens with different concrete compression strength tested under the impact loading that are applied by dropping constant weight hammer from five different heights. The acceleration arises from the impact loading is measured against time. The change of velocity, displacement and energy are calculated for all specimens. The failure modes of the specimens with normal and high concrete compression strength are observed under the loading of constant weight impact hammer that are dropped from different heights. Impact behaviors of beams are positively affected from the strengthening with CFRP. Measured accelerations, the number of drops up to failure and dissipated energy are increased. Finite element analysis that are made by using ABAQUS software is used for the simulation of experiments, and model gave compatible results with experiments.

A Study on the Simplified Presumption Method for the Prediction of Cooling and Heating Performance in a Fresh Air Load Reduction System by Using Geothermal Energy (지열을 이용한 외기부하저감시스템의 냉각 및 가열효과 예측을 위한 간이추정법에 관한 연구)

  • Son, Won-Tug;Park, Kyung-Soon
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.22 no.9
    • /
    • pp.628-634
    • /
    • 2010
  • This paper presents a feasibility study of a fresh air load reduction system by using an underground double floor space. The fresh air is introduced into the double slab space and passes through the opening bored into the footing beam. The air is cooled by the heat exchange with the inside surface of the double slab space in summer, and heated in winter. This system not only reduces sensible heat load of the fresh air by heat exchange with earth but also reduces latent heat load of the fresh air by ad/de-sorption of underground double slab concrete. In this paper, we proposed a simplified presumption method for the prediction of cooling and heating performance in the system. In conclusion the proposed method has been verified by comparing with the calculated value of the numerical analysis model by using nonlinear two-dimension hygroscopic question.

Experimental Study on the Period Control of an U-tube Type Anti-Rolling Tank by using a Double Layer Duct (이중덕트를 이용한 U자형 감요수조의 주기조절 실험 연구)

  • Ju, Youngkwang;Kim, Yong Jig;Ha, Youngrok
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.52 no.2
    • /
    • pp.135-142
    • /
    • 2015
  • The Anti-Rolling Tank(ART) has an advantage over the other roll stabilizing devices, when ship is staying and working at one site of sea. An important design point of ART is the tank tuning, that is, matching the tank natural period to the ship's roll natural period. Since the load condition and consequently the roll natural period of ship is to be changed widely, the natural period of ART also has to be changed widely. In case of the existing U-tube type ART with a single layer duct, the tank natural period can be changed in a relatively narrow range. This paper suggests a new U-tube type ART system using a double layer duct to enable wide change of ART natural period. Through the roll experiments performed in regular beam waves for a box-type model ship, it is shown that the double layer duct ART has about two times wider period range and a better reducing effect of roll magnitude than the single layer duct ART.

Interface formation between $MgF_2$ and Si(111) studied by LEED, AES, and TPD

  • Y.S. Chung;J.Y. Maeng;Kim, Sehun
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 1999.07a
    • /
    • pp.183-183
    • /
    • 1999
  • The phases and interface formation of MgF2 on Si(111) were studied by using LEED, AES, and TPD. When thick MgF2 film was deposited on the Si(111) surface at RT뭉 annealed at higher temperatures, a sequence of LEED patterns (no LEED pattern $\longrightarrow$1$\times$1$\longrightarrow$3$\times$1$\longrightarrow$7$\times$7) was observed. On the 1$\times$1 model in which Mg adsorbs on T4 site and F on H3 site could explain the simultaneous desorption of SiF2 and Mg. When thin MgF2 film was deposited, and initial $\alpha$-$\times$1 phase transforms to 3$\times$3 and $\beta$-1$\times$1 by thermal annealing with a slow evaporation of F and diffusion of Mg into the surface. the 3$\times$3 surface changes to ${\gamma}$-1$\times$1 by the selective desorptioon of F under e-beam irradiation and subsesquently to a Mg-induced {{{{ SQRT { 3} }}}} structure by annealing at $600^{\circ}C$.

  • PDF

Progressive Fracture Analysis of Concrete by Boundary Element Method and its Stabilizing Technique (경계요소법에 의한 콘크리트의 파괴진행해석 및 안정화 기법)

  • 송하원;전재홍
    • Magazine of the Korea Concrete Institute
    • /
    • v.8 no.6
    • /
    • pp.205-212
    • /
    • 1996
  • This paper presents progressive fracture analysis of concrete using boundary element method and its stabilizing technique. To determine ultimate strength and to predict nonlinear behavior of concrete during progressive crack growth, the modelling of fracture process zone is done based on Dugdale-Barenblatt model with linear tension-softening curve. We regulate displacement and traction boundary integral equation of solids including crack boundary and analyze progressive fracture of concrete beam and compact tension specimen. Also a numerical technique which considers the growth of stress-free crack of concrete during the analysis and removes snapback of postpeak behavior is proposed.

Behavior of Reinforced Dapped End Beams with T-headed Bar and Steel Fibers (헤디드 바와 강섬유로 보강된 Dapped End Beam의 구조 거동에 관한 실험적 연구)

  • Choi Jin Hyouk;Lee Chang Hoon;Lee Joo Ha;Yoon Young Soo
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2004.11a
    • /
    • pp.49-52
    • /
    • 2004
  • In this studies, Dapped End Beams(DEB) having disturbed regions were designed by using strut tie model, and the main purpose of this paper is that whether T-headed bars and Steel fibers will be present or not. The ability of DEB with T-headed bars have a superior performance rather than others, such as improved ductility, larger energy adsorption and enhanced post-peak load carrying capability. The capacity of DEB with steel fibers also show increase of ductility, shear strength, fatigue strength and crack. Each DEB with both headed bars and steel fibers, headed bars, and steel fibers as a substitute reinforced steel in the disturbed regions and a DEB with only stirrup and tie reinforced steel were comparable. In contrast, the headed bar stirrups, the tie headed bars and the reinforced steel fibers did not lose their anchorage and hence were able to develop strain hardening and also served to delay buckling of the flexural compression steel. Excellent load-deflection predictions were obtained by increasing the tension stiffening effect to account for high load effects.

  • PDF

Design for Linearly Polarized Microstrip Antenna using Electromagnetic-Coupled Dipoles (전자기결합 다이폴을 이용한 직선편파 마이크로스트립 안테나의 설계)

  • 민경식;장철순
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.12 no.7
    • /
    • pp.1057-1066
    • /
    • 2001
  • This paper describes a design for linear polarization antenna using the EMCD (electromagnetically coupled dipole). The analysis and the design of model antennas are conducted by FDTD method. Vertical and horizontal linear polarizations are easily obtained by variation of dipole position. In 1-element antenna design, mutual coupling between microstrip feed line and radiator is considered. Design parameters of each 1-element antenna with vertical and horizontal polarization are used for array design. Radiation power and main beam tilting angle can be controlled by the offset and the distance between radiating elements in an array, respectively. 5-element array antennas are fabricated and measured to prove the design validity. The results of FDTD simulation and measurement show the reasonable agreement.

  • PDF

DEVELOPMENT OF TRANSVERSE STRENGTH MONITORING SYSTEM FOR LOADOUT, TOWING AND FLOATOFF OPERATION

  • Yang, Yeong-Tae;Park, Byeong-Nam;Lee, Chun-Bo;Song, Seok-Bu
    • Proceedings of the Korea Committee for Ocean Resources and Engineering Conference
    • /
    • 2002.10a
    • /
    • pp.83-87
    • /
    • 2002
  • 종강도 위주의 일반 상선의 LMC 의 경우는 단지 선박을 l 차원 Beam Model 로 단순화하여 선미로부터 선수까지의 Weight Distribution 과 Buoyancy Distribution 을 계산하여 두 값의 차이를 Shear Force 로 계산하고 Shear Force 적분값을 Bending Moment 로 계산한다. 횡강도가 중요시되는 Barge 선의 경우 Global Transverse Strength 같은 경우에는 위의 식을 적용할 수 있으나 복수의 바지선을 Hinge Type 이 아닌 Fixed Type 으로 고정시켜 사용할 경우 각각의 Connector 에 작용하는 Strength 값이 횡강도의 큰 비중을 차지한다. 일반적인 Load Master Computer 의 경우 이와 같은 계산이 불가능하며 NAPA 와 같은 전용 계산 프로그램의 경우 하나의 Condition 을 계산하는데 소요되는 시간이 많아 실질적인 Monitoring 은 불가능하다. 이에 특수목적의 Load Master Computer(ShipManager-88) 를 제작하게 되었고 이 Program 을 이용하여 Loadout 과 Floatoff 의 Simulation 을 수행하고 Monitoring 하였다. ShipManager-88 은 Barge 선의 종강도 횡강도, Stability, Trim & Draft 등을 계산하며 Sequence 기능으로 실제 LOADOUT 과 FLOATOFF 시의 모의시뮬레이션을 수행해 볼 수 있으며 Online Interlace 제공으로 Tank 에 설치된 센서에서 Level 값을 받아 실시간으로 현재 선박의 상태를 정확하게 계산할 수 있다. 실제 LOADOUT and FLOATOFF 를 수행하면서 Check 한 부분은 종강도, 횡강모 Stability, Deform, Connector Strength, Level 등을 Check 하였고 종방향의 LOADOUT 이 불가능한 Project 를 위해 Transverse LOADOUT 을 이용할 계획이다.

  • PDF

Finite element analysis of reinforced concrete spandrel beams under combined loading

  • Ibraheem, O.F.;Bakar, B.H. Abu;Johari, I.
    • Computers and Concrete
    • /
    • v.13 no.2
    • /
    • pp.291-308
    • /
    • 2014
  • A nonlinear, three-dimensional finite element analysis was conducted on six intermediate L-shaped spandrel beams using the "ANSYS Civil FEM" program. The beams were constructed and tested in the laboratory under eccentric concentrated load at mid-span to obtain a combined loading case: torsion, bending, and shear. The reinforcement case parameters were as follows: without reinforcement, with longitudinal reinforcement only, and reinforced with steel bars and stirrups. All beams were tested under two different combined loading conditions: T/V = 545 mm (high eccentricity) and T/V = 145 mm (low eccentricity). The failure of the plain beams was brittle, and the addition of longitudinal steel bars increased beam strength, particularly under low eccentricity. Transverse reinforcement significantly affected the strength at high eccentricities, that is, at high torque. A program can predict accurately the behavior of these beams under different reinforcement cases, as well as under different ratios of combined loadings. The ANSYS model accurately predicted the loads and deflections for various types of reinforcements in spandrel beams, and captured the critical crack regions of these beams.