• Title/Summary/Keyword: beagle

Search Result 427, Processing Time 0.029 seconds

Effect of rhPMP-2 coated implants on alveolar ridge augmentation in dogs (성견에서 골형성단백질이 코팅된 임플란트가 치조골 증대에 미치는 영향)

  • Park, Chan-Kyung;Kim, Jong-Eun;Shin, Ju-Hee;Ryu, Jae-Jun;Huh, Jung-Bo;Shin, Sang-Wan
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.48 no.3
    • /
    • pp.202-208
    • /
    • 2010
  • Purpose: This study was aimed to evaluate the effect of rhPMP-2 coated implants on alveolar ridge augmentation in dogs. Materials and methods: Six Beagle dogs were used in this study. Six 8.0 mm long anodized surface titanium implants were placed 5 mm into the mandibular alveolar ridge following 6 month of healing period after extraction. Each animal received three implants coated with rhBMP-2 and three uncoated control implants using the randomized split-mouth design. Radiographic examinations were undertaken immediately at implant placement (baseline), at weeks 4 and 8 after implant placement. The amount of bone augmentation was evaluated by measuring the distance from the uppermost point of the coverscrew to the marginal bone. Implant Stability Quotient (ISQ) values were measured immediately at implant placement and 8 weeks after implant placement. For the statistical analysis, Man-Whitney ranksum test and Wilcoxon signed rank test of SPSS 12.0 software were used (P=.05). Results: The BMP group exhibited radiographic vertical bone augmentation about $0.6{\pm}0.7$ mm at 8 weeks later while controls showed bone loss about $0.4{\pm}0.6$ mm. There was significant difference among the rhBMP-2 group and controls in bone level change (P<.05). The ISQ values were significantly higher in the BMP-2 group than the control group at 8 weeks later (P<.05), while there was no significant difference at surgery. Conclusion: Within the limitation of this study, the rhBMP-2 coated on anodized implant could stimulate vertical alveolar bone augmentation, which may increase implant stability significantly on completely healed alveolar ridge.

The Effect of N-acetyl cysteine (NAC) loading on the bone formation surrounding sandblasted and large-grit and acid-etched implants in the dog: A pilot study (성견에 식립된 sandblasted and large-grit and acid-etched 임플란트에서 N-acetyl cysteine(NAC)의 탑재가 주위 골형성에 미치는 영향에 대한 선행연구)

  • Seo, Jae-Min;Kim, In-Ju;Bae, Min-Soo;Lee, Jung-Jin;Ahn, Seung-Geun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.58 no.2
    • /
    • pp.77-85
    • /
    • 2020
  • Purpose: The aim of the present study was to investigate the effects of N-acetyl cysteine (NAC) loading on the bone formation surrounding sandblasted, large-grit and acid-etched (SLA) implants. Materials and methods: Implantation of NAC loaded SLA implants (NSI group) and SLA implants (SI group) was performed bilaterally in the mandible of 4 adult beagle dogs (each group, n = 8). The animals were sacrificed after a healing period of 3 and 6 weeks, respectively (n = 2 animal each). Dissected blocks were processed for histomorphometrical analysis. Bone to implant contact percentage (BIC%) and bone volume (BV%) were assessed histomorphometrically. Results: BIC% of NAC loaded SLA implants were about 50% higher than that of SLA implants at 3 weeks of bone healing, but not significantly (51.79 vs 35.43%; P=.185). BV% of NAC loaded SLA implants were significantly higher than that of SLA implants at 3 weeks of bone healing (45.09 vs 37.57 %; P=.044). At 6 weeks of bone healing, BIC% and BV% of two experimental groups were similar (P>.05). Conclusion: Within the limits of the present study, NAC loading have a positive effects on the early bone formation surrounding SLA implants. So, it might be concluded that NAC loading enhance the osseointegration and shorten the healing time after implantation of the SLA implants.

Effects Of Cultured Bone Cell On The Regeneration Of Alveolar Bone (배양골세포 이식이 치조골재생에 미치는 영향)

  • Jeong, Soon-Joon;Herr, Yeek;Park, Joon-Bong;Lee, Man-Sup;Kwon, Young-Hyuk
    • Journal of Periodontal and Implant Science
    • /
    • v.26 no.1
    • /
    • pp.1-26
    • /
    • 1996
  • This study was performed to estimate the effects of cultured bone cell inoculated on porous type hydroxyaptite for the regeneration of the artificial alveolar bone defect. In this experiment 3 beagle dogs were used, and each of them were divided into right and left mandible. Every surgical intervention were performed under the general anesthesia by using with intravenous injection of Pentobarbital sodium(30mg/Kg). To reduce the gingival bleeding during surgery, operative site was injected with Lidocaine hydrochloride(l:80,000 Epinephrine) as local anesthesia. After surgery experimental animal were feeded with soft dietl Mighty dog, Frisies Co., U.S.A.) for 1 weeks to avoid irritaion to soft tissue by food. 2 months before surgery both side of mandibular 1st premolar were extracted and bone chips from mandibular body were obtained from all animals. Bone cells were cultured from bone chips obtained from mandible with Dulbecco's Modified Essential Medium contained with 10% Fetal Bovine Serum under the conventional conditions. Porous type hydroxyapatite were immerse into the high concentrated cell suspension solution, and put 4 hours for attachin the cells on the surface of hydroxyapatite. Graft material were inserted on the artificial bone defect after 3 days of culture. Before insertion of cellinoculated graft material, scanning electronic microscopic observation were performed to confirm the attachment and spreading of cell on the hydroxyapatite surface. 3 artificial bone defects were made with bone trephine drill on the both side of mandible of the experimental animal. First defect was designed without insertion of graft material as negative control, second was filled with porous replamineform hydroxyapatite inoculated with cultured bone marrow cells as expermiental site, and third was filled with graft materials only as positive control. The size of every artificial bone defect was 3mm in diameter and 3mm in depth. After the every surgical intervention of animals, oral hygiene program were performed with 1.0% chlorhexidine digluconate. All of the animals were sacrificed at 2, 4, 6 weeks after surgery. For obtaining histological section, tissus were fixed in 10% Buffered formalin and decalcified with Planko - Rycho Solution for 72hr. Tissue embeding was performed in paraffin and cut parallel to the surface of mandibular body. Section in 8um thickness of tissue was done and stained with Hematoxylin - Eosin. All the specimens were observed under the light microscopy. The following results were obtained : 1. In the case of control site which has no graft material, less inflammatory cell infiltration and rapid new bone forming tendency were revealed compared with experimental groups. But bone surface were observed depression pattern on defect area because of soft tissue invasion into the artificial bone defect during the experimental period. 2. In the porous hydroxyapatite only group, inflammatory cell infiltration was prominet and dense connective tissue were encapsulated around grafted materials. osteoblastic activity in the early stage after surgery was low to compared with grafted with bone cells. 3. In the case of porous hydroxyapatite inoculated with bone cell, less inflammatory cell infiltration and rapid new bone formation activity was revealed than hydroxyapatite only group. Active new bone formation were observed in the early stage of control group. 4. The origin of new bone forming was revealed not from the center of defected area but from the surface of preexisting bony wall on every specimen. 5. In this experiment, osteoclastic cell was not found around grafted materials, and fibrovascular invasion into regions with no noticeable foreign body reaction. Conclusively, the cultured bone cell inoculated onto the porous hydroxyapatite may have an important role of regeneration of artificial bone defects of alveolar bone.

  • PDF

Proteinases and their Inhibitors in Cartilage and Synovial Fluid Acquired from a Canine Osteoarthritic Model (개 퇴행성 관절염 모델을 이용한 연골과 활액 내 단백질 분해 효소와 억제제의 작용 연구)

  • Seo, Jae-Won;Lee, Hae-Beom;Kim, Nam-Soo;Lee, Young-Hoon;Kang, Hyung-Sub;Kim, In-Shik;Park, Sang-Youel
    • Journal of Veterinary Clinics
    • /
    • v.26 no.2
    • /
    • pp.144-149
    • /
    • 2009
  • Chondrocytes and synovial fluid derived markers are used to monitor for osteoarthritis(OA). Specific inhibitors, known as tissue inhibitors of metalloproteinases(TIMP), regulate the proteolytic activity of matrix metalloproteinases(MMP). This study investigated whether MMP and TIMP levels were altered in synovial fluid and cartilage following the experimental induction of OA in canines. Twenty mature beagle dogs underwent a unilateral surgical transection of the cranial cruciate ligament and the medial collateral ligament as well as a medial meniscectomy. Matrix metalloproteinase-2 and MMP-9 levels were assayed using Western blot and TIMP-2 levels were measured with enzyme-linked immunosorbent assays four weeks after OA induction. Increased MMP-2 expression was observed in chondrocytes isolated from cartilage following OA induction, but MMP-9 expression decreased. Matrix metalloproteinase-2 and MMP-9 levels in synovial fluid from the OA induced joint significantly increased compared to those of the sham group. Tissue inhibitors of metalloproteinase-2 concentrations were higher in chondrocytes from the OA cartilage, yet TIMP-2 remained lower in the synovial fluid of OA. This suggests the elevated release of MMP-9 over MMP-2 into the synovial fluid following the cartilage degradation-related death of chondrocytes after OA. Osteoarthritis can be further deteriorated by increased MMP activity in the synovial fluid because TIMP-2 exist low concentration into the extracellular matrix. As a result, MMP activity, particularly MMP-9 activity, can be useful as a biomarker in diagnosing and monitoring the early stages of canine OA.

Radiographic, MRI and Histopathologic Assessment to Standardize Canine Spinal Cord Injury Model (척수손상 모델 견 표준화를 위한 방사선, 자기공명영상 및 조직 병리 평가)

  • Seong, Yun-Sang;Yun, Sung-Ho;Park, Jai-Soon;Kim, Hee-Kyung;Chang, Yong-Min;Ku, Sae-Kwang;Park, Hyun-Jeong;Jang, Kwang-Ho
    • Journal of Veterinary Clinics
    • /
    • v.27 no.5
    • /
    • pp.546-552
    • /
    • 2010
  • Previous studies could not offer available guideline to decide size of balloon and grade of injury before induction of spinal cord injury (SCI) because grade of SCI was assessed after inserting a catheter and each experimental animal were different in body size and weight as well as in species. This study was performed to provide guideline for standardized SCI model. Eight healthy adult beagle dogs that had 8 mm of spinal canal height were assigned to four groups according to the diameter of balloon and compression time: 4 mm/3hrs, 4 mm/6hrs, 4 mm/12hrs and 6 mm/3hrs group. Radiography was performed to standardize between experimental animal and balloon before selecting balloon diameter to induce SCI. Behaviors outcomes, somatosensory evoked potentials (SEPs), magnetic resonance imaging (MRI) and histopathological examination were evaluated. Behaviors outcomes and SEPs were not available to assess grade of SCI and those only indicate SCI. The damaged area was revealed clear hyperintensity on STIR image and T2WI after induction of SCI. The hyperintense area on MRI was cranially and caudally expanded with increasing of the diameter of balloon or the compression time. Well corresponded to expanding of hyperintense area on MRI, the damaged region and the numbers of caspase-3 and PARP immunoreactive cells were increased on histopathological findings. Therefore, these results will be considered fundamental data to induce standardized SCI model in experimental animal that has various weight and size.

The Effect of Doxapram on Cardiopulmonary Function in Dogs under Total Intravenous Anesthesia with Remifentanil and Propofol (개에서 Remifentanil과 Propofol에 의한 완전 정맥 내 마취 시 Doxapram 투여가 심폐기능에 미치는 효과)

  • Yun, Sungho;Kwon, Youngsam
    • Journal of Veterinary Clinics
    • /
    • v.32 no.6
    • /
    • pp.491-498
    • /
    • 2015
  • We investigated the effect of constant rate infusion (CRI) with doxapram on cardiopulmonary function during total intravenous anesthesia (TIVA) with remifentanil and propofol CRI in dogs. Fifteen male Beagle dogs were randomly divided into 3 groups. All groups were premedicated with medetomidine ($20{\mu}g/kg$, IV) and anesthetized by remifentanil/propofol CRI for one and half hour. At the initiating of the anesthesia, different doses of doxapram for each group were administrated as the followings; D1 group - doxapram 0.25 mg/kg bolus followed by doxapram $8.33{\mu}g/kg/min$, D2 group - doxapram 2 mg/kg bolus followed by doxapram $66.66{\mu}g/kg/min$, control group - normal saline. The anesthetic depth for surgery was well maintained in all groups throughout the anesthetic periods. The respiratory rate was significantly higher in D2 group than that of control group (p < 0.05). The values of $PaO_2$ and $SaO_2$ were significantly increased in both D1 and D2 groups compared with control group (p < 0.05). High dose of doxapram (D2 group) significantly decreased the level of $PaCO_2$ compared with control group (p < 0.05). The values of systolic, mean and diastolic arterial pressure were significantly increased in doxapram 2 group (p < 0.05). There were no significant differences in the values of heart rate and pH of arterial blood. Therefore, doxapram CRI may be useful to alleviate the suppression of cardiopulmonary function including hypoxia and hypotension during TIVA with remifentanil and propofol in dogs.

In Vivo Preperation of Standard Reference Materials of Lead in Blood (생체내 혈중 납 표준물질의 제조)

  • Chung, Kyou-Chull;Choi, Ho-Chun
    • Journal of Preventive Medicine and Public Health
    • /
    • v.28 no.4 s.51
    • /
    • pp.863-873
    • /
    • 1995
  • This report describes a preperation and characterization of canine blood lead(Pb) standard reference material(SRM). Three adult beagle dogs(A, B, and C)were orally dosed with gelatin capsules containing $Pb(NO_3)_2$, equivalent to $10\sim80mg$ Pb/kg body weight. Blood was drawn 24 hours after the dose from the cephalic vein into lead free 500ml Pyrex beaker in which EDTA.K was contained as an anticoagulant. The amount of lead given to individual dog was varied arbitrarily. Three month later, 3 canine animals were orally dosed with lead secondarily to make mixed SRM(D1) which was mixed different concentrations of lead in bloods with A1, B1, and C1 in vitro. The SRMs for A, B, C, A1, B1, C1, and D1 were distributed 2ml each into more than 300 lead free bottles, and were stored in refregerator at $4^{\circ}C$. The amount of lead in canine whole blood samples were determined using a Varian 30A atomic absorption spectrophotometer(AAS) with a model GTA-96 graphite tube atomizer with D2 background correction and a Hitachi Z-8100 AAS with Zeeman background correction. The sensitivity and detection limits for lead determination of Varian 30A were $0.46{\mu}g/L,\;0.34{\mu}g/L,\;and\;0.56{\mu}g/L,\;0.14{\mu}g/L$ of Hitachi Z-8100, respectively. Day to day variations in determination of blood lead concentration in a certain sample were $31.11{\pm}1.36{\mu}g/100ml$ by Varian 30A, and $33.08{\pm}0.82{\mu}g/100ml$ by Hitachi Z-8100, showing the difference of 3% between the two results. At the blood lead concentrations of $56.31{\pm}1.98{\mu}g/100ml(A),\;40.89{\pm}0.80{\mu}g/100ml(B),\;59.01{\pm}1.38{\mu}g/100ml(C)$, the precisions of replicated measurements by AAS were 3.52%, 1.96%, and 2.34%, respectively. Coefficient variation(CV) of SRMs(A, B, and C) within a standard sample were ranged from 0.92% to 7.50%, and those between 5 standard samples were 1.21%, 2.64%, and 1.11%, respectively, showing inter-vial variation of $1{\mu}g/100ml$. Lead levels in SRMs during one month storage were unchanged. The overall recoveries were $89.6\sim100.4%,\;91.6\sim101.9%,\;90.3\sim100.0%$ for A, B, and C SRMs, means were $56.46{\pm}2.69{\mu}g/100ml,\;39.35{\pm}1.89{\mu}g/100ml,\;57.40{\pm}2.31{\mu}g/100ml$, and measurement ranges were$52.88{\pm}59.26{\mu}g/100ml,\;37.47{\pm}41.68{\mu}g/100ml,\;54.80{\pm}60.69{\mu}g/100ml$, respectively. Those results were laid within confidence limits values. The lead concentrations in the mixed sample(D1) stored over one month period were ranged from $32.76{\mu}g/100ml\;to\;33.54{\mu}g/100ml$, with CV ranging from 1.2% to 2.7%. The results were similiar to each of single samples(A1, B1, and C1) in respect of homogeneity and stability. Results of the mixed blood sample analysed after 1 month storage at $4^{\circ}C$ by four other laboratories(L1, L2, L3, L4) were similar with those of our laboratory($L5;31.18{\pm}0.24{\mu}g/100ml$, acceptable range by $CDC;25.18\sim37.18{\mu}g/100ml$), showing the concentrations of $25.91{\pm}1.19{\mu}g/100ml(L1),\;34.16{\pm}0.22{\mu}g/100ml(L2),\;35.68{\pm}0.85{\mu}g/100ml(L3),\;30.95{\pm}0.46{\mu}g/100ml(L4)$ in a each samples.

  • PDF