• Title/Summary/Keyword: basement length

Search Result 32, Processing Time 0.026 seconds

Subsurface Structure of the Yeongdong Basin by Analyzing Aeromagnetic and Gravity Data

  • Kim, Kyung-Jin;Kwon, Byung-Doo
    • Journal of the Korean earth science society
    • /
    • v.23 no.1
    • /
    • pp.87-96
    • /
    • 2002
  • Aeromagnetic and gravity data were analyzed to delineate the subsurface structure of the Yeongdong basin and its related fault movement in the Okcheon fold belt. The aeromagnetic data of the total intensity (KIGAM, 1983) were reduced to the pole and three dimensional inverse modeling, which considers topography of the survey area in the modeling process, were carried out. The apparent susceptibility map obtained by three dimensional magnetic inversion, as well as the observed aeromagnetic anomaly itself, show clearly the gross structural trend of the Yeongdong basin in the direction on between $N30^{\circ}E$ and $N45^{\circ}E$. Gravity survey was carried out along the profile, of which the length is about 18.2 km across the basin. Maximum relative Bouguer anomaly is about 7 mgals. Both forward and inverse modeling were also carried out for gravity analysis. The magnetic and gravity results show that the Yeongdong basin is developed by the force which had created the NE-SW trending the magnetic anomalies. The susceptibility contrast around Yeongdong fault is apparent, and the southeastern boundary of the basin is clearly defined. The basement depth of the basin appears to be about 1.1 km beneath the sea level, and the width of the basin is estimated to be 7 km based on the simultaneous analysis of gravity and magnetic profiles. There exists an unconformity between the sedimentary rocks and the gneiss at the southeastern boundary, which is the Yeongdong fault, and granodiorite is intruded at the northwestern boundary of the basin. Our results of gravity and magnetic data analysis support that the Yeongdong basin is a pull-apart basin formed by the left-stepping sinistral strike-slip fault, which formed the Okcheon fold belt.

On the Design of Cantilever Type High Speed Towing Carriage with Excellent Acceleration Performance (가속성능이 우수한 외팔보형 고속예인전차의 설계)

  • Kim, Jae Sung;Kim, Hyochul
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.53 no.3
    • /
    • pp.228-236
    • /
    • 2016
  • Extraordinarily the establishment of towing tank has been initiated after the allocation of space at the basement floor of existing building through remodeling procedure. Therefore the asymmetric tank should be unavoidably determined by compromising with the allowable space and existing building structure. Consequently the shape of towing carriage ought to be selected as a cantilever type to match with the given environmental conditions. Finally the major role of the towing tank has been configured on the fundamental research work for the high speed marine vehicles. Due to the limited length of towing tank, it is appeared that the carriage should accelerated with 1.2m/sec2 which is equivalent to twice of the maximum acceleration in ordinary practices on design application of carriage. In such a condition the exerted total power of motor could not be converted to traction force of the carriage without slip for the acceleration. To overcome these difficulties the contact pressure of a horizontal traction wheel to rail has been reinforced by the elastic recovery force of springs on supporting rollers. It is believed that the design experience of the high speed towing carriage under unusual circumferential condition and acceleration barrier could be utilized not only on the design of high speed towing carriage but also on the improvement of existing facilities.

Blasting Standardization works for NATM on the Seoul Subway Construction by Dr, Ginn Huh (서울 지하철공사 발파공법의 표준화)

  • Heo, Jin
    • Journal of the Korean Professional Engineers Association
    • /
    • v.16 no.3
    • /
    • pp.5-23
    • /
    • 1983
  • On the Seoul Metropolitan Subway Construction of No. 3, 4 Line, the total length is 57 Km and it is now undergoing almost 55% progress. The working method is classified into Open Cut of 70% and the rest of 30% tunnelling method in the 48 job site. Above tunnelling method is execute by American Steel Support System and the rest of 10 job site carried out by New Austria Tunnelling Method. This paper describes Blasting Standardizations works on the above Tunnelling ' Open Cut Method under big slogan, first safety, second execution. As a superintendent, I strived standardization of works with Better powder, Better Drills ' Better Pattern. Geological structure of Seoul area is composed by Jurassic Granite and also the above rockgroup are over burden by Alluviums as a Unconformity. First of all, I carried out the standard amount of powder and burden through experimental standard blasting by each powder as following Blasting works in the subway construction is surrounding shop Building, under pass the city river and also under pass highest building basement floor. I made allowable Blasting Vibration Value by West-Germany Vornorm DIN 4150, Teil 3 and should measure each blasting works as fellows all of powder is used basically Low-Gravity and Low Velocity such as Slurry, Ammonium Nitrate ' Finex I, II. for Smooth Blasting Instead of Gelatin Dynamite. Electric Detonation Cap is used basically M/S Delay Cup instead of Electric delay ' Simultaneous cap. I applied following formula V=KW3/4 $D^{-2}$ V=Particle Velocity (Cm/sec) K=Ginh Huh's Value W=Delay Charge (Kg) D=Distance(m) In the Open Cut, within 1m distance from H-pile I made to use the Concrete breaker, as following V=7W/$^{0.5}$V/$^{-1.75}$ On the Concentrate Building area, I advise to use Light class drill ø36m Bit and advance 1.1m per round blasting the three boom jumbo drill over ø45mm used only suburb of city.e Light class drill ø36m Bit and advance 1.1m per round blasting the three boom jumbo drill over ø45mm used only suburb of city.

  • PDF

Material Analysis and Provenance Interpretation for Rock Properties of the Gwangjueupseong (Gwangju Town Wall), Korea (광주읍성 축성암석의 재질분석과 산지해석)

  • Lee, Myeong-Seong;Chun, Yu-Gun;Seo, Jeong-Seog;Lee, Chan-Hee
    • Journal of Conservation Science
    • /
    • v.25 no.1
    • /
    • pp.61-76
    • /
    • 2009
  • Gwangjueupseong (Gwangju Town Wall) has been found in the site of the Asian Culture Complex (former Provincial Government of Jeonnam) by archaeological field survey. The length of the remaining wall is 85.1m, and the Town Wall consists of ten kinds of rock type. The major rock types are dacite (41.1%) and andesite (35.7%). Dacite composes main rock blocks of the wall, and andesite is used to fill the cavity between main rock blocks. These rocks look very similar to basement rocks of the Mudeung Mountain on the basis of occurrence features, magnetic susceptibility, petrological, mineralogical and geochemical properties. Also, quarrying traces were found on the southwestern slope of the mountain along the Jeungsimsa Temple valley. Thus, it is probable that the rock materials of the Gwangju Town Wall were supplied from the Mudeung Mountain and that they were transported along the Gwangju river.

  • PDF

Ultrastructural studies on the surface of Puragonimus westermani metacercaria (폐흡충 피낭유충 표피의 형태학적 관찰)

  • Kim, Gyeong-Min;An, Myeong-Hui;Min, Deuk-Yeong
    • Parasites, Hosts and Diseases
    • /
    • v.25 no.2
    • /
    • pp.129-140
    • /
    • 1987
  • The present study was undertaken to demonstrate the surface structure of Paragonimus westermani metacercaria in Korea with special reference to the distribution of sensory papillae. Metacercariae were isolated from crayfish, one of the second intermediate tost of P. westermani in Bogil island, Chollanam-do (Province), Korea, where has been known as an endemic area of human paragonimiasis. Isolated metacercariae were encysted and examined with light. scanning and transmission electron microscopes for morphological features. On the surface of iBetacercariae, three types of sensory FaFillae were identified. Large domed papillae ($3~5{\mu\textrm{m}}$), which were covered with wrinkled plasma n!embrane of the worm, were distributed on the oral and ventral suckers only. On the oral sucker, these large domed papillae were 12~13 in number. On the other hand large domed papillae on the ventral sucker were constantly 6 in number and hexagonal in distribution. Small domed papillae ($2~3{\mu\textrm{m}}$), of which surface was more smooth than those of large ones, were distributed symmetrically on the ventral (30~32 pairs) and dorsal surfaces (40~42 Pairs). Ciliated Papillae ($0.8~1.5{\mu\textrm{m}}$) were observed about 5~6 in number around the oral sucker and 3~5 pairs each on the ventral and dorsal surface of the body. Single Fcinted spines covered the entire surface of the body except around the excretory pore. Spines on the anterior fart of the body were 0.9~2.0${\mu\textrm{m}}$ in length and $45~55/100{\mu\textrm{m}}$2 in number, and were gradually reduced in length ($0.4~1.4{\mu\textrm{m}}$) and in nuns.her ($12~27/100{\mu\textrm{m}}$2) toward the posterior part. The body wall of p. westermoni metacercariae was consisted with anucleated syncytium layer, fibrous interstitial layer and musclar layer. In the anucleated syncytium, biconcave ($0.15~0.55{\mu\textrm{m}}$) and spherical ($0.08~0.16{\mu\textrm{m}}$) secretory granules, which were transferred from epidermal cells via protoplasmic tubules, mitochondria and rihoEorses, T-ere observed. Spines originated around the basement membrane protruded externally. Epidermal cells were consisted with a nucleus and a cytoplasm, and connected to syncytium with protoplasmic tubules. In the cytoplasm many secretory granules, mitochondria, Golgi complex, endoplasmic reticula, ribosomes and lipid droplets were observed.

  • PDF

Working Conditions, Job Satisfaction and Organizational Commitment of Physical Therapists (물리치료사의 근무실태와 직무만족 및 직장애착)

  • Ahn Soyoun;Kim Won-Joong;Huh Young-Bae
    • The Journal of Korean Physical Therapy
    • /
    • v.14 no.4
    • /
    • pp.308-322
    • /
    • 2002
  • The main objective of this paper is to examine the working conditions of physical therapists and to investigate the level of job satisfaction and organizational commitment under different working conditions. A survey was conducted through structured questionnaire for the physical therapists working in Busan area, and data from 175 therapists were utilized in the final analysis. Survey items included general characteristics of the therapists(sex, age, education, marital status, religion, income, career years, etc.), their working conditions(kinds of organizations they work in, location of PT room, weekly working hours, average number of patients, number of co-workers, equipments/facilities, etc.), and organizational effectiveness measured in terms of job satisfaction and organizational commitment. Major results are as follows: 1) As for the general characteristics of the surveyed physical therapists, male(51.4$\%$) slightly exceeded female(48.6$\%$) and majority(more than 90$\%$) was 20-39 in age. Also, there were more single(57.7$\%$) than married(42.3$\%$), and 54.9$\%$ of the respondents had religion while 45.1$\%$ did not. In terms of the ranks in their organizations, only a few of them(6.9$\%$) were managers, and monthly salary mostly ranged from $\₩$1,000,000 to $\₩$2,500,000. More than half of them worked in various kinds of hospitals, with the remaining in health centers or social welfare institutions. 2) In regard to the working conditions of the respondents, 19.4$\%$ of PT rooms were located in basement areas while the remaining 80.6$\%$ in first to third floors. 34.3$\%$ of them treated 15 patients or less per day, whereas 25.1$\%$ treated 31 patients or more. Also, 52$\%$ recorded physical therapy charts periodically. As for the equipments and facilities, 25.1$\%$ felt 'sufficient' and 40$\%$'insufficient.' 3) The respondents provided various kinds of suggestions for the improvement of their working conditions, where the most important were 'salary raise' and 'reduction of working hours.' In addition, their requests to the PT Association included 'permission of opening of independent practice,' 'permission of legal specialty,' and 'vitalization of the Association.' 4) The comparative analysis of job satisfaction and organizational commitment among different characteristics of the respondents revealed that there was no significant difference between male and female, but in terms of age, the group of 40 or older was highest in both aspects. Besides, therapists who had 15 or more years of hospital career reported higher job satisfaction and organizational commitment than the others. It was also found that the level of organizational commitment increased as the rank of the respondents got higher. There were no significant differences in terms of marital status and religion. 5) Comparison with regard to working conditions showed that therapists employed in university hospitals, health centers and social welfare institutions felt higher job satisfaction and organizational commitment than those in community hospitals and clinics. Also, respondents who worked in basement areas had significantly lower job satisfaction than otherwise. The length of weekly working hours did not really affect the level of job satisfaction, but it was important to maintain 'regular working hours' for the hospitals to improve the employees' organizational commitment. As for the number of patients per day, 'medium level' (21-25 patients) had highest scores in both aspects. And, finally, sufficiency of equipments and facilities was found to be important for the improvement of organizational commitment.

  • PDF

Structural Design And Analysis of Haeundae Doosan We've The Zenith (해운대 두산 위브 더 제니스 구조설계)

  • Park, Ki-Hong;Park, Suk-Jin
    • Proceedings of the Korean Institute Of Construction Engineering and Management
    • /
    • 2008.11a
    • /
    • pp.93-98
    • /
    • 2008
  • Haeundae Doosan We've The Zenith project is adjacent to Suyoung-bay, now it is in the process of excavation and foundation work. The main use of the tower is residence which height is 300m and 80 floor, the highest residential reinforced concrete building through the Orient. It is comprised of 3 high- rised buildings and 1 low-rised building, the basement is 230m wide and 200m length sized mass structure. The lateral resistance system is acted effectively against the lateral load and satisfactorily against the wind vibration by the 4 direction extension of the center core wall($700{\sim}800mm$ thickness) and reinforced concrete column set around the slab. Flat-plate slab system(250mm thickness) is adjusted for the slab system and it enables effective work process and shortening the working term by minimizing the ceiling height and not needing to install perimeter beam and drop panel. The strength and serviceability of the structure is able to be monitored and estimated constantly through the health monitoring system during the construction and after the construction.

  • PDF

The Assessment of Management Practices on Foodservice , Clinical Nutrition Service in Hospital Foodservice Operations (병원 급식소의 급식 및 임상영양 서비스 업무 실태 조사)

  • Hong, Wan-Su;Kim, Hye-Jin;Jang, Eun-Jae
    • Journal of the Korean Dietetic Association
    • /
    • v.6 no.2
    • /
    • pp.136-147
    • /
    • 2000
  • The aim of this research was to examine the management practices related to foodservice.clinical nutrition service provided by hospital foodservice operations. A survey of 30 hospital food nutrition service departments was undertaken and detailed information was collected from each, including surveys of 176 dietitians and 30 foodservice managers. Statistical data analysis was completed using the SAS/win 6.11 package for descriptive analysis and t-test. The results of this study can be summarized as follows : Out of 30 hospitals, 73.3%(22) were directly operated and 26.7%(8) were under contract foodservice management. Licensed number of beds were 768.7, with an average length of 11.4 days. The general characteristics of the dietitians were that 49.4% were aged between 25-29, and 60.8% were ordinary dietitians. 76.7% had bachelor's degree, 15.9% with master's degree and 7.4% were college graduates. Most hospital dietitians had internship training and 35.2% took a training course of 6 to 12 months. The average space of kitchen was 452.52 $m^2$, with 133.63$m^2$ for modified diet space and 18.13$m^2$ for nutrition counselling room space. The total number of normal meals was 1,255.47, with 502.93 of modified meals. The average calorie of normal meals was 2,145.04kcal, with 91.9g of protein contained in normal meal. The total food waste was 351.40kg. An average monthly cost for disposing food waste was 745,171.67 won. 83.3% of the kitchens were on the 1st basement and only 66.7%(20) of 30 hospitals had its own nutrition counselling room. 80% used dishwashers and 66.7% had an exclusive elevator for delivering meals. 80.0% of hospitals used centralized delivery service. 90% had established an area for hygiene division, 70% used dry zone within the dishwashers for sterilization, 66.7% provided spoon and chopstick, and 100% used dish cover. As means of food waste treatment, most hospitals(56.7%) used animal feed by contracters, followed by means of collection by contracters(30%) and in-house high speed fermentation machines(13.3%). It was found that only 33.3% hospitals regularly checked temperatures of the meals given to patients. Total productivity index was 3.72(meals/hour) in average, with an average productivity index for normal diet of 5.41. Average productivity index for modified diet was 4.62. Productivity indices for patient meals and clinical nutrition were 5.01(meals/hour) and 1.12(cases/hour) respectively and hospitals under self-operated foodservice management received higher points on clinical nutrition productivity index(P<0.01) than hospitals under contract foodservice management.

  • PDF

EXPERIMENTAL STUDY OF PERIPHERAL NERVE REGENERATION BY USING NON-TUBULAR NATURAL CELLULOSE MEMBRANE NERVE CONDUIT (비관형 천연 셀룰로오스막 도관을 이용한 말초신경 재생에 대한 실험적 연구)

  • Kim, Soung-Min;Lee, Jong-Ho;Lee, Suk-Keun
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.32 no.4
    • /
    • pp.295-307
    • /
    • 2006
  • Styela clava, called non-native tunicate or sea squirt, is habitat which include bays and harbors in Korea and several sites in the sea faced world. We fabricate cellulose membrane nerve conduit (CMNC) from this native sea squirt skin, and evaluate the capacity of promoting peripheral nerve regeneration in the rat sciatic nerve defect model. After processing the pure cellulose membrane from the sea squirt skin as we already published before, CMNC was designed as a non-tubular sheet with 14 mm length and 4 mm width. Total eleven male Spraque-Dawley rats (12 weeks, weighing 250 to 300g) were divided into sham group (n=2), silicone tube grafted control group (n=3) and experimental group (n=6). Each CMNC grafted nerve was evaluated after 4, 8 and 12 weeks in the experimental group, and after 12 weeks, sciatic function was evaluated with sciatic function index (SFI) and gait analysis, and histomorphology of nerve conduit and the innervated tissues of sciatic nerve were all examined using image analyzer and electromicroscopic methods in the all groups. The regenerated axon and nerve sheath were found only in the inner surface of the CMNC after 4 weeks and became more thicker after 8 and 12 weeks. In the TEM study, CMNC grafted group showed more abundant organized myelinated nerve fibers with thickened extracellular matrix than silicone conduit grafted group after 12 weeks. The sciatic function index (SFI) and ankle stance angle (ASA) in the functional evaluation were $-47.2{\pm}3.9$, $35.5^{\circ}{\pm}4.9^{\circ}$ in CMNC grafted group (n=2) and $-80.4{\pm}7.4$, $29.2^{\circ}{\pm}5.3^{\circ}$ in silicone conduit grafted group (n=3), respectively. And the myelinated axon was 41.59% in CMNC group and 9.51% in silicone conduit group to the sham group. The development of a bioactive CMNC to replace autogenous nerve grafts offers a potential and available approach to improved peripheral nerve regeneration. As we already published before, small peptide fragment derived from the basement membrane matrix proteins of squirt skin, which is a kind of anchoring protein composed of glycocalyx, induced the effective axonal regeneration with rapid growth of Schwann cells beneath the inner surface of CMNC. So the possibilities of clinical application as a peripheral nerve regeneration will be able to be suggested.

Corrosion of Calcareous Rocks and Ground Subsidence in the Muan Area, Jeonnam, Korea (전남 무안지역에 분포하는 석회질암의 용식작용과 지반침하)

  • Ahn, Kun-Sang
    • The Journal of the Petrological Society of Korea
    • /
    • v.16 no.2 s.48
    • /
    • pp.47-58
    • /
    • 2007
  • This study examines the distribution of basement rocks in Gyochon-ri, Muan-eup, Muan-gun, Jeonnam where ground subsidence occurred in June 2005, and traces corrosion of limestone. Mica schist and rhyolite are distributed in the surface of the study area, but thick limestone layer with large and small caverns are distributed underground. A horizon of limestone with maximum width of 300 m and 4 km of length was found along the detour which is in the north of pound subsidence. Such identification of limestone presence would be very useful to predict potential ground subsidence. Limestone in this area was disturbed by fold and fault due to severe shearing deformation. Small caverns were frequently found in anticline part of folds formed in limestone layer. Schists with different thicknesses were intercalated in the limestone with shearing deformation and consist of sheet silicate minerals (chlorite and mica) and quartz. In sections of weathered specimen, it is shown that biotite of schist part was altered into chlorite and corrosion of calcite around the schist followed. This suggest that ground water permeated between intercalated sheet silicate minerals and corrosion of limestone began. And small caverns were generated where active corrosion occurred. This study suggests that because of many reasons (for instance, reclamation of the Bulmu reservior and excess pumping), cavern water level was lowered and cave sediments were removed, and it caused ground subsidence to occur.