• 제목/요약/키워드: baseline wander removal

검색결과 6건 처리시간 0.024초

Fully Analog ECG Baseline Wander Tracking and Removal Circuitry using HPF Based R-peak Detection and Quadratic Interpolation

  • Nazari, Masoud;Rajeoni, Alireza Bagheri;Lee, Kye-Shin
    • Journal of Multimedia Information System
    • /
    • 제7권3호
    • /
    • pp.231-238
    • /
    • 2020
  • This work presents a fully analog baseline wander tracking and removal circuitry using high-pass filter (HPF) based R-peak detection and quadratic interpolation that does not require digital post processing, thus suitable for compact and low power long-term ECG monitoring devices. The proposed method can effectively track and remove baseline wander in ECG waveforms corrupted by various motion artifacts, whereas minimizing the loss of essential features including the QRS-Complex. The key component for tracking the baseline wander is down sampling the moving average of the corrupted ECG waveform followed by quadratic interpolation, where the R-peak samples that distort the baseline tracking are excluded from the moving average by using a HPF based approach. The proposed circuit is designed using CMOS 0.18-㎛ technology (1.8V supply) with power consumption of 19.1 ㎼ and estimated area of 15.5 ㎟ using a 4th order HPF and quadratic interpolation. Results show SNR improvement of 10 dB after removing the baseline wander from the corrupted ECG waveform.

전원잡음과 기저선변동을 고려한 이동형 ECG 센서모듈 및 모니터링 시스템 구현 (Portable ECG Sensor Module and Monitoring System Implementation Considering Reduction of Powerline Noise and Baseline Wander)

  • 오도창;최동혁;이홍우
    • 제어로봇시스템학회논문지
    • /
    • 제12권10호
    • /
    • pp.1022-1028
    • /
    • 2006
  • A portable ECG sensor module and monitoring system which has the powerline noise reduction and the baseline wander removal is proposed. A small-szie ECG sensor H/W module with the 8-bits microprocessor is implemented. The ECG waveform can be inspected anytime with PDA in real time, and transmitted to the PC through wireless LAN. Portable ECG system can offer the environment that give the lasting medical service to the elderly and the long-time hospitalized patients at the wanted place, and the system can be attached to the chair, wheel chair, treadmill, elderly walker and used to monitor the health condition of man

Design of IIR Notch Filter for Removal of Baseline wander and Power Line Interference from ECG Signal

  • Chivapreecha, Sorawat;Dejhan, Kobchai;Yimman, Surapan
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2005년도 ICCAS
    • /
    • pp.848-851
    • /
    • 2005
  • This paper proposes a design of IIR notch filter with modified pole placements. The pole angle is derived from quadratic programming to find the appropriate pole position on the unit circle in z-plane in order to achieve the symmetry of the amplitude response. The simulation results are shown when compared with the conventional design technique. Moreover, it uses the TMS320C31 DSP chip for hardware implementation. Finally, the hardware implementation can be applied to removal of ECG baseline wander and elimination of AC power line interference in ECG signal.

  • PDF

다중레이트 디지털 필터 설계 및 심전도 신호의 기저선 변동 및 전원 잡음 제거 (Baseline Drift Reduction and Suppression of Power Line Noises in ECG Signal by Designing Multirate Digital Filter)

  • 김정환;김현태;박상은;이정환;김경섭
    • 전기학회논문지
    • /
    • 제63권4호
    • /
    • pp.551-558
    • /
    • 2014
  • Baseline drift reduction and removal of power line noises in electrocardiogram are often necessary to avoid the distortions in extracting the fiducial features. With this aim, the multirate digital filtering algorithm is suggested to design and implement Finite Impulse Response or Infinite Impulse Response Filter by changing the sampling rate with omitting or interpolating intermediate ECG data. After the experimental simulations performed, we can conclude the fact that we can suppress the baseline wander and power line disturbances in ECG signal with reducing the computational complexities in which we do not keep the original and high sampling frequency.

심전도 기저선 흔들림 잡음 제거를 위한 적응형 필터 설계 (Adaptive Filter Design for Eliminating Baseline Wandering Noise of Electrocardiogram)

  • 최철형;세이푸르;김시경;박인덕;김영필
    • 한국정보기술학회논문지
    • /
    • 제15권12호
    • /
    • pp.157-164
    • /
    • 2017
  • 모바일 심전도(ECG) 신호 측정은 수 mV의 작은 소 신호를 측정하는 기술로서 동적 잡음을 제거하기 위한 많은 연구가 진행 되어 왔다. 특히 심전도 전극 케이블의 흔들림이나 피부의 움직임으로 인하여 유발 되는 등 전위선 잡음의 제거는 심전도 측정을 위한 핵심 연구 내용 중 하나이다. 본 연구에서는 심전도 신호의 등전위선 동적 잡음을 제거하기 위해 정규화 최소 자승법(NLMS)와 지연 최소 자승법(DLMS) 방식을 결합한 적응 필터의 스텝 사이즈를 결정하여 적용하는 기법을 제안 하였다. 제안한 기법은 필터의 초기 스텝 사이즈를 조정하여 기본 노이즈를 차감 한 후, 해당 과정에서 발생할 수 있는 심전도 신호 특성의 왜곡을 줄이는 방법이다. 본 논문에서의 제안한 기법에서, 필터 계수의 값은 필터 순서 사이즈 및 왜곡 최소화 인자에 의해 직접적으로 스케일링 설정 된다. 그리고 제안된 필터는 실시간 필터링에 필수적인 계산의 복잡성을 줄이도록 하여, 연산시간을 줄일 수 있을 것으로 기대되므로 소형 프로세서 및 저전력 소비가 요구되는 모바일 심전도 측정기기에 적합한 장점을 가진다. 또한 종래의 NLMS 적응 필터와 신호대잡음비(SNR)를 비교하여 우수함을 확인하였다.

적응형 필터와 가변 임계값을 적용하여 잡음에 강인한 심전도 R-피크 검출 (Noise-robust electrocardiogram R-peak detection with adaptive filter and variable threshold)

  • 세이푸르;최철형;김시경;박인덕;김영필
    • 한국산학기술학회논문지
    • /
    • 제18권12호
    • /
    • pp.126-134
    • /
    • 2017
  • 심전도(ECG) 신호에서 R-피크를 추출하는 기법에 대하여 많은 연구가 진행 되어 왔으며, 다양한 방법으로 구현되어 왔다. 그러나 이러한 검출 방법 대부분은 실시간 휴대용 심전도 장치에서 구현하기가 복잡하고 어려운 단점이 있다. R-피크 검출을 위해서는 심전도 데이터에 대하여 베이스라인 드리프트 및 상용전원 잡음 제거 등의 적절한 전처리 및 후가공이 필요하며, 특히 적응형 필터를 활용한 기법에서는 적절한 임계값을 선택하는 것이 중요하다. 적응형 필터의 임계값을 추출하는 방식에서는 고정형(Fixed) 및 적응형(adaptive)으로 구분할 수 있다. 고정 임계 값 추출 방식은 고정된 임계값 보다 낮은 값의 입력이 들어오는 경우에 R-피크 값을 감지하지 못하는 경우가 있으며, 적응 임계값 추출 방식은 때때로 잡음에 의한 잘못된 임계값을 도출하여, 다른 파형(P혹은 T파)의 피크를 감지하는 경우도 나타난다. 본 논문에서는 계산상의 복잡성이 적고, 코드 구현이 단순하면서도 잡음에 강인한 R-피크 검출 알고리즘을 제안한다. 제안된 방식은 앞서 설명한 임계값 추출 문제를 해결하기 위해서, 적응형 필터를 사용해, 심전도 신호에서 베이스 라인 드리프트 제거를 하여 적절한 임계값을 계산하도록 한다. 그리고 필터 처리된 심전도 신호의 최소 값과 최대 값을 사용하여 적절한 임계값이 자동으로 추출 되도록 한다. 그런 다음 심전도 신호로부터 R-피크를 검출하기 위해 임계값 아래에서 'neighborhood searching' 기법이 적용된다. 제안된 방법은 R-피크 검출의 정확도를 향상시키고, 계산 량을 줄여 검출 속도가 보다 빨라지도록 하였다. 다음으로 R-피크 값이 검출 되면, R-R interval 등의 값을 이용해 심박 수를 계산할 수 있도록 한다. 실험결과 심박 수 검출 정확도와 감도가 약 100%로 매우 높았음을 확인할 수 있었다.