• Title/Summary/Keyword: baseline length

Search Result 237, Processing Time 0.024 seconds

Recent Vegetation History and Environmental Changes in Wangdeungjae Moor of Mt. Jiri

  • Kim, Jae-Geun;Lee, Yang-Woo
    • The Korean Journal of Ecology
    • /
    • v.28 no.3
    • /
    • pp.121-127
    • /
    • 2005
  • To reveal vegetation history and environmental changes in Mt. Jiri, sediment cores were collected from Wangdeungjae moor of Mt. Jiri. Overall dry matter accumulation rates and sedimentation rates by $^{14}C-dating$ were 0.027 $kg{\cdot}m^{-2}{\cdot}yr^{-1}$ and 0.184 mm/yr since 1250 ($760{\pm}40$ yrs BP, 14 cm in depth). There are three pollen zones; the first zone is below 14 cm depth where Quercus dominated, the second zone is from 14 cm to 6 cm depth where Gramineae increased and Quercus and Salix dominated and the third zone is from 6 cm depth to the top where Pinus and Quercus dominated. Total pollen concentration gradually increased from bottom to the top of sediment core, which implies wet, anaerobic and cool condition during covered period by the core. Calcium and magnesium contents had increased since 14 cm depth, with peaks at 13 and 20 cm depths. This indicates that groundwater had recently become relatively more important than surface water as water source of Wangdeungjae moor Exotic plant or Chenopodiacea pollen was less than 1%. There was little variation in total N and P contents along the length of the core. These results support that Wangdeungjae moor has been little affected by anthropogenic activities. Also, nutrients and heavy metal contents indicate the baseline condition of Wangdeungjae moor.

Analysis of Tidal Effects on Network-based GPS Positioning (조석영향에 의한 망기반 GPS 측위 변화 분석)

  • Yoon, Ha-Su;Hong, Chang-Ki;Kwon, Jay-Hyoun;Choi, Yun-Soo
    • Proceedings of the Korean Society of Surveying, Geodesy, Photogrammetry, and Cartography Conference
    • /
    • 2010.04a
    • /
    • pp.31-34
    • /
    • 2010
  • The rover positioning is performed by estimating the baseline vector components in doubledifference positioning mode. This means that relative displacement due to the tide effects can be neglected when the distance between the reference and rover station is relatively short. However, the tide effects should be carefully modeled and removed as the baseline length gets longer. In this study, the relative displacement over the Korean Peninsula due to tide effects are examined through the numerical analysis. The results show that the tide modeling is required for the precise GPS positioning at cm-level accuracy.

  • PDF

Anomaly Detection Method Using Entropy of Network Traffic Distributions (네트워크 트래픽 분포 엔트로피를 이용한 비정상행위 탐지 방법)

  • Kang Koo-Hong;Oh Jin-Tae;Jang Jong-Soo
    • The KIPS Transactions:PartC
    • /
    • v.13C no.3 s.106
    • /
    • pp.283-294
    • /
    • 2006
  • Hostile network traffic is often different from normal traffic in ways that can be distinguished without knowing the exact nature of the attack. In this paper, we propose a new anomaly detection method using inbound network traffic distributions. For this purpose, we first characterize the traffic of a real campus network by the distributions of IP protocols, packet length, destination IP/port addresses, TTL value, TCP SYN packet, and fragment packet. And then we introduce the concept of entropy to transform the obtained baseline traffic distributions into manageable values. Finally, we can detect the anomalies by the difference of entropies between the current and baseline distributions. In particular, we apply the well-known denial-of-service attacks to a real campus network and show the experimental results.

Direction Finding Method of the Uniform Circular Array Antenna Using the Pattern of Phase Differences (원형배열 안테나의 위상차 패턴을 이용한 방향탐지 기법)

  • Lim, Joong-Soo
    • Journal of the Korea Convergence Society
    • /
    • v.10 no.1
    • /
    • pp.1-6
    • /
    • 2019
  • In this paper, we have studied a direction finding method of the radio signal by comparing the phase difference and its pattern from the uniform circular array antenna. In the phase comparison direction finding, if the length of the antenna baseline is longer than 0.5 wavelength of the incident signal, azimuth ambiguity occurs in which two or more azimuth angles are calculated in the same phase difference. The azimuthal ambiguity is removed by fusing the phase difference of the 5 antennas. The developed ambiguity elimination technology reduces the azimuth error where the antenna baseline is shorter than 1.236 wavelength in the uniform circular array with five antennas. This algorithm is very useful for the design of direction finder of an electronic information system.

Repeated irradiation by light-emitting diodes may impede the spontaneous progression of experimental periodontitis: a preclinical study

  • Hyemee Suh;Jungwon Lee;Sun-Hee Ahn;Woosub Song;Ling Li;Yong-Moo Lee;Yang-Jo Seol;Ki-Tae Koo
    • Journal of Periodontal and Implant Science
    • /
    • v.53 no.2
    • /
    • pp.120-134
    • /
    • 2023
  • Purpose: We investigated whether repeated irradiation with light-emitting diodes (LEDs) at a combination of 470 nm and 525 nm could suppress the progression of experimental periodontitis. Methods: A experimental periodontitis model was established in the second, third, and fourth premolars of the mandible in beagle dogs for 2 months. The spontaneous progression of periodontitis was monitored under the specified treatment regimen for 3 months. During this period, the animals were subjected to treatments of either plaque control only (control) or plaque control with LED application (test) at 2-week intervals. The clinical parameters included the probing pocket depth (PPD), gingival recession (GR), and the clinical attachment level (CAL). Histomorphometric analysis was performed using measurements of the length of the junctional epithelium, connective tissue (CT) zone, and total soft tissue (ST). Results: There were significant differences in PPD between the control and test groups at baseline and 12 weeks. When the change in PPD was stratified based on time intervals, it was shown that greater differences occurred in the test group, with statistical significance for baseline to 12 weeks, 6 to 12 weeks, and baseline to 6 weeks. There was no significant difference in GR between the control and test groups at any time points. Likewise, no statistically significant differences were found in GR at any time intervals. CAL showed a statistically significant difference between the control and test groups at baseline only, although significant differences in CAL were observed between baseline and 12 weeks and between 6 and 12 weeks. The proportion of CT to ST was smaller for both buccal and lingual areas in the control group than in the test group. Conclusions: Repeated LED irradiation with a combination of 470-nm and 525-nm wavelengths may help suppress the progression of periodontal disease.

Force Assessment of Thermoformed and Direct-printed Aligners in a Lingual Bodily Movement of a Central Incisor Over Time: A 14-day In Vitro Study

  • Mary Linda Remley;Gabriel Ferreira Pessoa Carvalho Miranda ;Brent Bankhead;Julie McCray;Ki Beom Kim
    • Journal of Korean Dental Science
    • /
    • v.16 no.1
    • /
    • pp.23-34
    • /
    • 2023
  • Purpose: This study aims to investigate the force delivery profile of thermoformed aligners (TFA) compared with direct-printed aligners (DPA) and to explore the effect of different activation amounts on forces and moments of respective groups. A secondary objective is to observe the amount of stress relaxation that occurs over the 7~14 days when aligners are maintained in a simulated intraoral environment. Materials and Methods: An in vitro setup was created to quantify forces and moments. It consisted of a three dimensional-printed base plate and segmented maxillary teeth, placed in a semi-enclosed chamber to maintain a temperature of 37℃. Ninety clear aligners were divided into nine groups of ten aligners each based on material types (Zendura, ATMOS, TC-85) and activation amounts. Aligners were created with 0.00, 0.25- and 0.50-mm activations for lingual bodily movement of the upper left central incisor and kept on models in the "stressed" position in a 37℃ water bath. Three force components acting on the upper left lateral incisor, upper left central incisor, and upper right central incisor were measured for each time point, beginning from the initial baseline measurement, 8 hours, 16 hours, 24 hours, 2 days, 3 days, 4 days, 5 days, 6 days, 7 days, and lastly, 14 days. Result: TC-85 aligners in every activation group showed less force on teeth than Zendura and ATMOS. Significant force levels from 0.0 mm activation were present and stayed consistent over the course of 14 days. Comparisons made for baseline measurements to 7-days and 14-days showed statistically significant change from the baseline force level. Conclusion: TC-85 aligners demonstrated lower, more consistent forces with fewer side effects. Aligners can generate forces even when no activation is programmed. No major decreases in force levels over time were observed; the intra-oral clinical simulated environment and length of observation time could contribute to this.

Surgery versus Nerve Blocks for Lumbar Disc Herniation : Quantitative Analysis of Radiological Factors as a Predictor for Successful Outcomes

  • Kim, Joohyun;Hur, Junseok W.;Lee, Jang-Bo;Park, Jung Yul
    • Journal of Korean Neurosurgical Society
    • /
    • v.59 no.5
    • /
    • pp.478-484
    • /
    • 2016
  • Objective : To assess the clinical and radiological factors as predictors for successful outcomes in lumbar disc herniation (LDH) treatment. Methods : Two groups of patients with single level LDH (L4-5) requiring treatment were retrospectively studied. The surgery group (SG) included 34 patients, and 30 patients who initially refused the surgery were included in the nerve blocks group (NG). A visual analogue scale (VAS) for leg and back pain and motor deficit were initially evaluated before procedures, and repeated at 1, 6, and 12 months. Radiological factors including the disc herniation length, disc herniation area, canal length-occupying ratio, and canal area-occupying ratio were measured and compared. Predicting factors of successful outcomes were determined with multivariate logistic regression analysis after the optimal cut off values were established with a receiver operating characteristic curve. Results : There was no significant demographic difference between two groups. A multivariate logistic regression analysis with radiological and clinical (12 months follow-up) data revealed that the high disc herniation length with cutoff value 6.31 mm [odds ratio (OR) 2.35; confidence interval (CI) 1.21-3.98] was a predictor of successful outcomes of leg pain relief in the SG. The low disc herniation length with cutoff value 6.23 mm (OR 0.05; CI 0.003-0.89) and high baseline VAS leg (OR 12.63; CI 1.64-97.45) were identified as predictors of successful outcomes of leg pain relief in the NG. Conclusion : The patients with the disc herniation length larger than 6.31 mm showed successful outcomes with surgery whereas the patients with the disc herniation length less than 6.23 mm showed successful outcomes with nerve block. These results could be considered as a radiological criteria in choosing optimal treatment options for LDH.

CenterNet Based on Diagonal Half-length and Center Angle Regression for Object Detection

  • Yuantian, Xia;XuPeng Kou;Weie Jia;Shuhan Lu;Longhe Wang;Lin Li
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.17 no.7
    • /
    • pp.1841-1857
    • /
    • 2023
  • CenterNet, a novel object detection algorithm without anchor based on key points, regards the object as a single center point for prediction and directly regresses the object's height and width. However, because the objects have different sizes, directly regressing their height and width will make the model difficult to converge and lose the intrinsic relationship between object's width and height, thereby reducing the stability of the model and the consistency of prediction accuracy. For this problem, we proposed an algorithm based on the regression of the diagonal half-length and the center angle, which significantly compresses the solution space of the regression components and enhances the intrinsic relationship between the decoded components. First, encode the object's width and height into the diagonal half-length and the center angle, where the center angle is the angle between the diagonal and the vertical centreline. Secondly, the predicted diagonal half-length and center angle are decoded into two length components. Finally, the position of the object bounding box can be accurately obtained by combining the corresponding center point coordinates. Experiments show that, when using CenterNet as the improved baseline and resnet50 as the Backbone, the improved model achieved 81.6% and 79.7% mAP on the VOC 2007 and 2012 test sets, respectively. When using Hourglass-104 as the Backbone, the improved model achieved 43.3% mAP on the COCO 2017 test sets. Compared with CenterNet, the improved model has a faster convergence rate and significantly improved the stability and prediction accuracy.

Comparison of Ovariectomy and Ovariohysterectomy in Terms of Postoperative Pain Behavior and Surgical Stress in Dogs (개에서 난소자궁절제술과 난소절제술 후 나타나는 통증 행동과 스트레스 반응의 비교)

  • Lee, Scott-S.;Lee, Seung-Yong;Park, Se-Jin;Kim, Young-Ki;Seok, Seong-Hoon;Hwang, Jae-Min;Lee, Hee-Chun;Yeon, Seong-Chan
    • Journal of Veterinary Clinics
    • /
    • v.30 no.3
    • /
    • pp.166-171
    • /
    • 2013
  • This study was conducted to evaluate the clinical relevance and effectiveness of ovariectomy (OVE) and ovariohysterectomy (OVH) in terms of postoperative pain behavior and surgical stress. Thirteen healthy intact mongrel purpose-bred female dogs were used in this study. OVE was performed in six dogs whereas OVH was performed in seven dogs. Prior to, 1, 2, 4, 6, 12, and 24 h after surgery, pain assessment was performed by using the Short form of Composite Measure Pain Scale (CMPS-SF) and blood analysis for the determination of glucose, creatine kinase (CK), and cortisol were done. Also, surgical time, duration of anesthesia, and incision length were compared between two groups. As a result, OVH group as opposed to OVE group showed significantly longer in surgical time, duration of anesthesia, and incision length. Also, based on the two-way ANOVA test, the CMPS-SF had significant differences (p < 0.05) between two groups, with the OVE dogs having lower values at 1, 2, 4, and 6 h postoperatively. In addition, in terms of CK, the value at 1, 2, 4, 6, and 12 h were significantly (p < 0.05) increased from the baseline value for the OVH group. However, as for CK in OVE group, the values at 4, 6, and 12 h were significantly increased from the baseline value. As for blood glucose, a significant (p < 0.05) increase from the baseline was shown at 1 h postoperatively in OVH group and no significant increase was shown in OVE group. In terms of serum cortisol level, the values at the 1 and 2 h were significantly (p < 0.05) increased from the baseline value for both groups. In conclusion, our study has shown that OVE can be considered as a superior choice in terms of sterilization technique in female dogs, considering shorter incision length, surgical time, duration of anesthesia along with lower pain and surgical stress response than OVH.

Slim Mobile Lens Design Using a Hybrid Refractive/Diffractive Lens (굴절/회절 하이브리드 렌즈 적용 슬림 모바일 렌즈 설계)

  • Park, Yong Chul;Joo, Ji Yong;Lee, Jun Ho
    • Korean Journal of Optics and Photonics
    • /
    • v.31 no.6
    • /
    • pp.281-289
    • /
    • 2020
  • This paper reports a slim mobile lens design using a hybrid refractive/diffractive optical element. Conventionally a wide field of view (FOV) camera-lens design adopts a retrofocus type having a negative (-) lens at the forefront, so that it improves in imaging performance over the wide FOV, but with the sacrifice of longer total track length (TTL). However, we chose a telephoto type as a baseline design layout having a positive (+) lens at the forefront, to achieving slimness, based on the specification analysis of 23 reported optical designs. Following preliminary optimization of a baseline design and aberration analysis based on Zernike-polynomial decomposition, we applied a hybrid refractive/diffractive element to effectively reduce the residual chromatic spherical aberration. The optimized optical design consists of 6 optical elements, including one hybrid element. It results in a very slim telephoto ratio of 1.7, having an f-number of 2.0, FOV of 90°, effective focal length of 2.23 mm, and TTL of 3.7 mm. Compared to a comparable conventional lens design with no hybrid elements, the hybrid design improved the value of the modulation transfer function (MTF) at a spatial frequency of 180 cycles/mm from 63% to 71-73% at zero field (0 F), and about 2-3% at 0.5, 0.7, and 0.9 fields. It was also found that a design with a hybrid lens with only two diffraction zones at the stop achieved the same performance improvement.