• Title/Summary/Keyword: base leakage

Search Result 161, Processing Time 0.032 seconds

A Study of Weldability for Pure Titanium by Nd:YAG Laser(IV) - Lap Welding and Application for Heat Exchanger - (순티타늄판의 Nd:YAG 레이저 용접성에 관한 연구(IV) - 겹치기 용접 및 실물 열교환기로의 적용 -)

  • Kim, Jong-Do;Kwak, Myung-Sub;Lee, Chang-Je;Kil, Byung-Lea
    • Journal of Welding and Joining
    • /
    • v.28 no.1
    • /
    • pp.66-71
    • /
    • 2010
  • With large specific strength and outstanding corrosion resistance and erosion resistance in sea water, titanium and titanium alloy are widely used in heat exchanger production. In particular, pure titanium demonstrates outstanding molding performance and may be considered optimal for production of heat exchanger. Since titanium is very vulnerable to oxidation and embrittlement during welding, processes with less heat input are widely used, and laser welding is widely applied by considering production performance and shield etc in atmosphere. So far, 1st report and 2nd report compared and analyzed embrittlement degrees by bead colors of weldment through oxygen and nitrogen quantitative analysis and hardness measurement, and evaluated welding performance and mechanical properties of butt welding. This study evaluated field applicability of lap welding to heat exchange plate of LPG re-liquefaction device for ships through tensile stress test, hardness test and internal pressure test etc after deducing optimal weding condition and applying to actual heat exchange plate. In bead overlap area, the experiment produced sound welds with no porosity or defect by increasing and decreasing laser power, and tensile-shear test results indicated virtually the same tension and yield strength as base metal. As a result of measuring hardness at lateral cross section and bead overlap zone of actual heat exchanger welds, hardness difference within 20Hv was produced at base metal, HAZ and weldment, and as a result of pneumatic and hydraulic pressure test, no leakage occurred.

Dynamic response of a base-isolated CRLSS with baffle

  • Cheng, Xuansheng;Liu, Bo;Cao, Liangliang;Yu, Dongpo;Feng, Huan
    • Structural Engineering and Mechanics
    • /
    • v.66 no.3
    • /
    • pp.411-421
    • /
    • 2018
  • Although a rubber isolation cushion can reduce the dynamic response of a structure itself, it has little influence on the height of a sloshing wave and even may induce magnification action. Vertical baffles are set into a base-isolated Concrete Rectangular Liquid Storage Structure (CRLSS), and baffles are opened as holes to increase the energy dissipation of the damping. Problems of liquid nonlinear motion caused by baffles are described using the Navier-Stokes equation, and the space model of CRLSS is established considering the Fluid-Solid Interaction (FSI) based on the Finite Element Method (FEM). The dynamic response of an isolated CRLSS with various baffles under an earthquake is analyzed, and the results are compared. The results show that when the baffle number is certain, the greater the number of holes in baffles, the worse the damping effects; when a single baffle with holes is set in juxtaposition and double baffles with holes are formed, although some of the dynamic response will slightly increase, the wallboard strain and the height of the sloshing wave evidently decrease. A configuration with fewer holes in the baffles and a greater number of baffles is more helpful to prevent the occurrence of two failure modes: wallboard leakage and excessive sloshing height.

Study on the Femtocell Vulnerability Analysis Using Threat Modeling (위협 모델링 기법을 이용한 펨토셀 취약점 분석에 대한 연구)

  • Kim, Jae-ki;Shin, Jeong-Hoon;Kim, Seung-joo
    • KIPS Transactions on Computer and Communication Systems
    • /
    • v.5 no.8
    • /
    • pp.197-210
    • /
    • 2016
  • Lately smartphone uasage is increasing and many Internet of Things (IoT) devices support wireless communications. Accordingly, small base stations which called femtocells are supplied to prevent saturation of existing base stations. However, unlike the original purpose of the femtocell with the advanced hacking technologies, Vulnerability such as gaining the administrator authority was discovered and this can cause serious problems such as the leakage of personal information of femtocell user. Therefore, identify security threats that may occur in the femtocell and it is necessary to ways for systematic vulnerability analysis. In this paper, We analyzed the security threats that can be generated in the femtocell and constructed a checklist for vulnerability analysis using the Threat Modeling method. Then, using the constructed checklist provides a scheme that can improve the safety of the femto cell through the actual analysis and taken the results of the femtocell vulnerabilities analysis.

MICROLEAKAGE OF COMPOMER IN CLASS II CAVITY (제 2 급 와동에 충전된 Compome의 미세누출에 관한 연구)

  • Im, Jae-Hun;Cho, Yong-Bum
    • Restorative Dentistry and Endodontics
    • /
    • v.24 no.2
    • /
    • pp.346-355
    • /
    • 1999
  • To evaluate the micro leakage of compomer, 4 materials were divided into 4 groups of 15 cavities each.(Group 1: Z-100, Group 2: Dyarct AP, Group 3: Fuji II LC, Group 4: Compoglass) After the class II cavities were prepared using carbide bur No. 553, all specimen were restored by incremental filling technique. In group 3, Z-100 was filled with a base of a light curing glass-ionomer. After 7 days, all specimens were thermocycled between $5^{\circ}C$ and $55^{\circ}C$ for 500 cycles, followed by placement in 50% silver nitrate dye for 2 hours at $37^{\circ}C$. After rinsed in distilled water, these teeth were immersed in photodeveloping solution and exposed to fluorescent light for 6 hours. Teeth were then washed in distilled water to remove the photodeveloping solution, sectioned mesio-distally and evaluated. The results were as follows : 1. In the cervical portion, there was significant difference between Fuji II LC and other groups(Z-100, Dyract AP, Compoglass), Fuji II LC had the least value.(p<0.05) 2. In the cervical portion, there was not significant difference among Dyract AP, Z-100 and Compoglass. 3. In the occlusal portion, there was not significant difference among Dyract AP, Z-100 and Compoglass. From the results above, In enamel, microleakage of compomer such as Dyract AP and Compoglass resemble to that of composite resin. It is thought that it is due to characteristics of composite resin portion of compomer. But in dentin, microleakage of compomer is higher than that of resin modified glass ionomer cement, it is thought that in compomer, acid-base reaction is not developed with dentin.

  • PDF

Early Predictive Values for Severe Rhabdomyolysis in Blunt Trauma

  • Park, Jung Yun;Kim, Myoung Jun;Lee, Jae Gil
    • Journal of Trauma and Injury
    • /
    • v.32 no.1
    • /
    • pp.26-31
    • /
    • 2019
  • Purpose: Rhabdomyolysis (RB) is a syndrome characterized by the decomposition of striated muscles and leakage of their contents into the bloodstream. Acute kidney injury (AKI) is the most significant and serious complication of RB and is a major cause of mortality in patients with RB. Severe RB (creatine kinase [CK] ${\geq}5,000$) has been associated with AKI. However, early prediction is difficult because CK can reach peak levels 1-3 days after the trauma. Hence, the aim of our study was to identify predictors of severe RB using initial patient information and parameters. Methods: We retrospectively analyzed 1,023 blunt trauma patients admitted to a single tertiary hospital between August 2011 and March 2018. Patients with previously diagnosed chronic kidney disease were excluded from the study. RB and severe RB were defined as a CK level ${\geq}1,000U/L$ and ${\geq}5,000U/L$, respectively. The diagnosis of AKI was based on RIFLE criteria. Results: The overall incidence of RB and severe RB was 31.3% (n=320) and 6.2% (n=63), respectively. On multivariable analysis, male sex (odds ratio [OR] 3.78, 95% confidence interval [CI] 1.43 to 10.00), initial base excess (OR 0.85, 95% CI 0.80 to 0.90), initial CK (OR 2.07, 95% CI 1.67 to 2.57), and extremity abbreviated injury scale score (OR 1.78, 95% CI 1.39 to 2.29) were found to predict severe RB. The results of receiver operating characteristic analysis showed that the best cutoff value for the initial serum CK level predictive of severe RB was 1,494 U/L. Conclusions: Male patients with severe extremity injuries, low base excess, and initial CK level >1,500 U/L should receive vigorous fluid resuscitation.

Influences of Cathodic Protection and Coating Properties on the Corrosion Control of Metallic Structure in Extremely Acidic Fluids

  • Chang, H.Y.;Yoo, Y.R.;Jin, T.E.;Kim, Y.S.
    • Corrosion Science and Technology
    • /
    • v.4 no.6
    • /
    • pp.242-249
    • /
    • 2005
  • A lot of parts in FGD (Flue Gas Desulfurization) systems of fossil-fuel power plants show the environments in which are highly changeable and extremely acidic corrosive medium according to time and locations, e.g. in duct works, coolers and re-heaters etc. These conditions are formed when system materials are immersed in fluid that flows on them or when exhausted gas is condensed into thin layered acidic medium to contact materials of the system walls and roofs. These environments make troublesome corrosion and air pollution problems that are occurred from the leakage of the condensed solution. To cathodically protect the metallic structures in extremely acidic fluid, the properties of the protective coatings on the metal surface were very important, and epoxy Novolac coating was applied in this work. On the base of acid immersion tests, hot sulfuric acid decreased the hardness of the coatings and reduced greatly the content of $Na_2O$, $Al_2O_3$, and $SiO_2$ among the main components of the coating. A special kind of CP(Cathodic Protection) system has been developed and tested in a real scale of the FGD facility. Applied coating for this CP system was peeled off and cracked in some parts of the facility. However, the exposed metal surface to extremely acidic fluid by the failure of the coatings was successfully protected by the new CP system.

Design and Implementation of Low power ALU based on NCL (Null Convention Logic) (NCL 기반의 저전력 ALU 회로 설계 및 구현)

  • Kim, Kyung Ki
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.18 no.5
    • /
    • pp.59-65
    • /
    • 2013
  • Conventional synchronous design circuits cannot only satisfy the timing requirement of the low voltage digital systems, but also they may generate wrong outputs under the influence of PVT variations and aging effects. Therefore, in this paper, a NCL (Null Convention Logic) design as an asynchronous design method has been proposed, where the NCL method doesn't require any timing analysis, and it has a very simple design methodology. Base on the NCL method, a new low power reliable ALU has been designed and implemented using MagnaChip-SKhynix 0.18um CMOS technology. The experimental results of the proposed NCL ALU have been compared to those of a conventional pipelined ALU in terms of power consumption and speed.

Optimal Inter-Element Spacing of FD-MIMO Planar Array in Urban Macrocell with Elevation Channel Modelling

  • Abubakari, Alidu;Raymond, Sabogu-Sumah;Jo, Han-Shin
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.11 no.10
    • /
    • pp.4759-4780
    • /
    • 2017
  • Full Dimension multiple input multiple output (FD-MIMO) architecture employs a planar array design at the Base Station (BS) to provide high order multi-user MIMO (MU-MIMO) via simultaneous data transmission to large number of users. With FD-MIMO, the BS can also adjust the beam direction in both elevation and azimuth direction to concentrate the energy on the user of interests while minimizing the interference leakage to co-scheduled users in the same cell or users in the neighboring cells. In a typical highly populated macrocell environment, modelling the elevation angular characteristics of three-dimensional (3D) channel is critical to understanding the performance limits of the FD-MIMO system. In this paper, we study the throughput performance of FD-MIMO system with varying elevation angular spread and inter-element spacing using a 3D spatial channel model. Our results show that for a typical urban scenario, horizontal beamforming with correlated antenna spacing achieves optimal performance but by restricting the spread of elevation angles of departure, elevation beamforming achieves high array gain with wide inter-element spacing. We also realize significant gains due to spatial array processing via modelling the elevation domain and varying the inter-element spacing for both the transmitter and receiver.

A Study on Anomaly Signal Detection and Management Model using Big Data (빅데이터를 활용한 이상 징후 탐지 및 관리 모델 연구)

  • Kwon, Young-baek;Kim, In-seok
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.16 no.6
    • /
    • pp.287-294
    • /
    • 2016
  • APT attack aimed at the interruption of information and communication facilities and important information leakage of companies. it performs an attack using zero-day vulnerabilities, social engineering base on collected information, such as IT infra, business environment, information of employee, for a long period of time. Fragmentary response to cyber threats such as malware signature detection methods can not respond to sophisticated cyber-attacks, such as APT attacks. In this paper, we propose a cyber intrusion detection model for countermeasure of APT attack by utilizing heterogeneous system log into big-data. And it also utilizes that merging pattern-based detection methods and abnormality detection method.

Mandibular condyle and infratemporal fossa reconstruction using vascularized costochondral and calvarial bone grafts

  • Jang, Hyo Won;Kim, Nam-Kyoo;Lee, Won-Sang;Kim, Hyung Jun;Cha, In-Ho;Nam, Woong
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.40 no.2
    • /
    • pp.83-86
    • /
    • 2014
  • There are some difficulties in approaching and removing the lesion in infratemporal fossa because of its anatomical location. After wide excision of tumor lesion, it is also difficult for reconstruction of mandibular condyle and cranium base on infratemporal fossa. Besides, there are some possibilities of cerebrospinal fluid leakage, intracranial infection and bone resorption. It is also challenging for functional reconstruction that allows normal mandibular movement, preventing mandibular condyle from invaginating into the skull. In this report, we present 14-month follow-up results of a patient who had undergone posterior segmental mandibulectomy including condyle and infratemporal calvarial bone and mandible reconstruction with free vascularized costochondral rib and calvarial bone graft to restoration of the temporomandibular joint area.