• 제목/요약/키워드: base isolated building

검색결과 98건 처리시간 0.032초

구조성능 목표를 고려한 면진설계 (Design of Base Isolated Building Considering Performance Based Design)

  • 황기태;이현호
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2004년도 춘계 학술발표회 제16권1호
    • /
    • pp.700-703
    • /
    • 2004
  • The purpose of this study is to present the design methodology of base isolated buildings. To achieve the goal of this study, time-history analysis was performed with seismic performance level and recorded seismic data. From the analysis results of MDOF system, the maximum. displacement and base shear were evaluated as 25 cm and $4\%$ by the input level which is maximum velocity of 50 kine. By introducing hybrid isolation system, seismic energy can be concentrated consequently high seismic capacity of the total building is secured.

  • PDF

Response spectrum analysis considering non-classical damping in the base-isolated benchmark building

  • Chen, Huating;Tan, Ping;Ma, Haitao;Zhou, Fulin
    • Structural Engineering and Mechanics
    • /
    • 제64권4호
    • /
    • pp.473-485
    • /
    • 2017
  • An isolated building, composed of superstructure and isolation system which have very different damping properties, is typically non-classical damping system. This results in inapplicability of traditional response spectrum method for isolated buildings. A multidimensional response spectrum method based on complex mode superposition is herein introduced, which properly takes into account the non-classical damping feature in the structure and a new method is developed to estimate velocity spectra from the commonly used displacement or pseudo-acceleration spectra based on random vibration theory. The error of forced decoupling method, an approximated approach, is discussed in the viewpoint of energy transfer. From the base-isolated benchmark model, as a numerical example, application of the procedure is illustrated companying with comparison study of time-history method, forced decoupling method and the proposed method. The results show that the proposed method is valid, while forced decoupling approach can't reflect the characteristics of isolated buildings and may lead to insecurity of structures.

Bound of aspect ratio of base-isolated buildings considering nonlinear tensile behavior of rubber bearing

  • Hino, J.;Yoshitomi, S.;Tsuji, M.;Takewaki, I.
    • Structural Engineering and Mechanics
    • /
    • 제30권3호
    • /
    • pp.351-368
    • /
    • 2008
  • The purpose of this paper is to propose a simple analysis method of axial deformation of base-isolation rubber bearings in a building subjected to earthquake loading and present its applicability to the analysis of the bound of the aspect ratio of base-isolated buildings. The base shear coefficient is introduced as a key parameter for the bound analysis. The bound of the aspect ratio of base-isolated buildings is analyzed based on the relationship of the following four quantities; (i) ultimate state of the tensile stress of rubber bearings based on a proposed simple recursive analysis for seismic loading, (ii) ultimate state of drift of the base-isolation story for seismic loading, (iii) ultimate state of the axial compressive stress of rubber bearings under dead loads, (iv) prediction of the overturning moment at the base for seismic loading. In particular, a new recursive analysis method of axial deformation of rubber bearings is presented taking into account the nonlinear tensile behavior of rubber bearings and it is shown that the relaxation of the constraint on the ultimate state of the tensile stress of rubber bearings increases the limiting aspect ratio.

Damage identification of isolators in base-isolated torsionally coupled buildings

  • Wang, Jer-Fu;Huang, Ming-Chih;Lin, Chi-Chang;Lin, Tzu-Kang
    • Smart Structures and Systems
    • /
    • 제11권4호
    • /
    • pp.387-410
    • /
    • 2013
  • This paper deals with the damage assessment for isolators of base-isolated building systems considering the torsion-coupling (TC) effect by establishing damage indices. The damage indices can indicate the reduction in lateral stiffness of the isolator story as explicit formulas in terms of modal parameters. In addition, the damage location, expressed in terms of the estimated damage index and eccentricities before and after damage, is also presented. Numerical analysis shows that the proposed algorithms are applicable for general base-isolated multi-story TC buildings. A procedure from the analysis of seismic response to the implementation of damage indices is demonstrated by using a numerical case. A system identification technique is employed to extract modal parameters from seismic responses of a building. Results show that the proposed indices are capable of detecting the occurrence of damage and preliminarily estimating the location of damaged isolator.

Uncertain-parameter sensitivity of earthquake input energy to base-isolated structure

  • Takewaki, Izuru
    • Structural Engineering and Mechanics
    • /
    • 제20권3호
    • /
    • pp.347-362
    • /
    • 2005
  • The input energy to a base-isolated (BI) building during an earthquake is considered and formulated in the frequency domain. The frequency-domain approach for input energy computation has some notable advantages over the conventional time-domain approach. Sensitivities of the input energy to the BI building are derived with respect to uncertain parameters in the base-isolation system. It is demonstrated that the input energy can be of a compact form via the frequency integration of the product between the input component (Fourier amplitude spectrum of acceleration) and the structural model component (so-called energy transfer function). With the help of this compact form, it is shown that the formulation of earthquake input energy in the frequency domain is essential for deriving the sensitivities of the input energy to the BI building with respect to uncertain parameters. The sensitivity expressions provide us with information on the most unfavorable combination of the uncertain parameters which leads to the maximum energy input.

지진시 저층건물 면진구조의 비선형 동적 거동 (Dynamic Stability Analysis of Base-Isolated Low-level Nonlinear Structure Under Earthquake Excitation)

  • 문병영;강경주;강범수;김계수
    • 대한기계학회논문집A
    • /
    • 제25권11호
    • /
    • pp.1743-1750
    • /
    • 2001
  • This paper presents an analysis of nonlinear response of the seismically isolated structure against earthquake excitation to evaluate isolation performances of a rubber bearing. In the analysis of the vibration of building, the building is modeled by lumped mass system where the restoring force is considered as linear, bilinear and trilinear. Fundamental equations of motion are derived for the base isolated structure, and hysteretic and nonlinear-elastic characteristics are considered for a numerical calculation. The excitation levels are magnified fur the recorded strong earthquake motions in order to examine dynamic stability of the structure. Seismic responses (of the building are compared fur the each restoring force type. As a result, it is shown that the effect of the motion by the nonlinear response of the building is comparatively not so large from a seismic design standpoint. The responses of the isolated structures reduce sufficiently and controled the motion of the building well in a practical range. By increasing the acceleration of the earthquake, the yielding of the farce was occurred in the concrete and steel frame, which shows the necessity of the exact nonlinear dynamic analysis.

New approach in design of seismic isolated buildings applying clusters of rubber bearings in isolation systems

  • Melkumyan, Mikayel G.
    • Earthquakes and Structures
    • /
    • 제4권6호
    • /
    • pp.587-606
    • /
    • 2013
  • The given paper presents a new approach in design of seismic isolation systems of base isolated buildings. The idea is to install not one big size rubber bearing under the columns and/or shear walls, or one by one with certain spacing under the load-bearing walls, but to install a group/cluster of small size bearings, in order to increase the overall effectiveness of the isolation system. The advantages of this approach are listed and illustrated by the examples. Also the results of analyses of some buildings where the approach on installation of clusters of rubber bearings was used in their isolation systems are given for two cases: i) when the analyses are carried out based on the provisions of the Armenian Seismic Code, and ii) when the time history analyses are carried out. Obtained results are compared and discussed. Paper also presents, as an example, detailed analysis and design of the 18-story unique building in one of the residential complexes in Yerevan. Earthquake response analyses of this building were carried out in two versions, i.e. when the building is base isolated and when it is fixed base. Several time histories were used in the analyses. Comparison of the obtained results indicates the high effectiveness of the proposed structural concepts of isolation systems and the need for further improvement of the Seismic Code provisions regarding the values of the reduction factors. A separate section in the paper dedicated to the design of high damping laminated rubber-steel bearings and to results of their tests.

스마트 수동 제어 시스템을 이용한 면진 건물의 내진 성능 개선 (Seismic Performance Improvement of Base Isolated Buildings using Smart Passive Control System)

  • 정형조;정찬국;최강민;이인원
    • 한국지진공학회논문집
    • /
    • 제10권6호
    • /
    • pp.37-46
    • /
    • 2006
  • 본 연구에서는 면진 건물의 내진 성능을 개선하기 위하여 최근 개발된 스마트 수동 제어 시스템을 적용하고 이의 효용성을 수치 모의실험을 통해 검증하였다. 스마트 수동 제어 시스템은 효과적인 반능동 제어 장치로 알려진 MR 감쇠기에 전자기 유도부를 도입하여 응답 변화에 따라 MR 감쇠기로 입력되는 전류를 변화시킴으로써 MR 감쇠기의 감쇠 특성을 조절하는 새로운 개념의 스마트 제진 시스템이다. 스마트 수동 제어 시스템에서 전자기 유도부는 영구자석과 솔레노이드 코일로 구성되며, 기존 스마트 제진 시스템의 계측기, 제어기, 외부 전원장치를 한꺼번에 대체할 수 있다. 면진 건물에 대한 스마트 수동 제어 시스템의 내진 성능을 수치적으로 검증하기 위하여 미국토목학회에서 제시한 면진 건물에 대한 벤치마크 제어 문제를 활용하였다. 스마트 수동 제어 시스템의 제진 성능을 MR 감쇠기를 이용한 기존 스마트 제어 시스템의 성능과 비교하였다. 수치 모의실험 결과를 통해 스마트 수동 제어 시스템이 면진 건물의 내진 성능을 개선하는 데 매우 유용함을 확인하였다.

Vibration control of hysteretic base-isolated structures: an LMI approach

  • Pozo, Francesc;Pujol, Gisela;Acho, Leonardo
    • Smart Structures and Systems
    • /
    • 제17권2호
    • /
    • pp.195-208
    • /
    • 2016
  • Seismic isolation systems are essentially designed to preserve structural safety, prevent occupants injury and properties damage. An active saturated LMI-based control design is proposed to attenuate seismic disturbances in base-isolated structures under saturation actuators. Using a mathematical model of an eight-storied building structure, an active control algorithm is designed. Performance evaluation of the controller is carried out in a simplified model version of a benchmark building system, which is recognized as a state-of-the-art model for numerical experiments of structures under seismic perturbations. Experimental results show that the proposed algorithm is robust with respect to model and seismic perturbations. Finally, the performance indices show that the proposed controller behaves satisfactorily and with a reasonable control effort.