• Title/Summary/Keyword: barrier performance

Search Result 816, Processing Time 0.032 seconds

Prediction Model for Saturated Hydraulic Conductivity of Bentonite Buffer Materials for an Engineered-Barrier System in a High-Level Radioactive Waste Repository

  • Gi-Jun Lee;Seok Yoon;Bong-Ju Kim
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.21 no.2
    • /
    • pp.225-234
    • /
    • 2023
  • In the design of HLW repositories, it is important to confirm the performance and safety of buffer materials at high temperatures. Most existing models for predicting hydraulic conductivity of bentonite buffer materials have been derived using the results of tests conducted below 100℃. However, they cannot be applied to temperatures above 100℃. This study suggests a prediction model for the hydraulic conductivity of bentonite buffer materials, valid at temperatures between 100℃ and 125℃, based on different test results and values reported in literature. Among several factors, dry density and temperature were the most relevant to hydraulic conductivity and were used as important independent variables for the prediction model. The effect of temperature, which positively correlates with hydraulic conductivity, was greater than that of dry density, which negatively correlates with hydraulic conductivity. Finally, to enhance the prediction accuracy, a new parameter reflecting the effect of dry density and temperature was proposed and included in the final prediction model. Compared to the existing model, the predicted result of the final suggested model was closer to the measured values.

Study on physical performance of lightweight foam concrete using oyster shells according to unit cement content (굴 패각을 사용한 경량기포 콘크리트의 단위시멘트량에 따른 물리적 성능에 관한 연구)

  • Hong, Snag-hun;Shin, Joung-Hyeon;Shin, Dong-uk;Kim, Bong-Joo;Jung, Ui-In
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2020.06a
    • /
    • pp.102-103
    • /
    • 2020
  • Research for heat insulation of buildings is being carried out, in which a heat exchange barrier is used around the openings and balcony parts as a method for heat exchange blocks. However, the preparation for a fire is inadequate. In order to improve the EPS used as a heat exchange barrier in an attempt to solve this, there is a study on lightweight foamed concrete, but as the amount of EPS used for strengthening fire resistance increases, it becomes lower. There is no strength applied to buildings, and also. There is a limit to the amount of EPS used. In the study, we use oyster shells to secure the EPS replacement rate limit of lightweight Foamed concrete, and try to measure the change of physical properties depending on the unit cement content.

  • PDF

Development of an Integrated Monitoring System for the Low and Intermediate Level Radioactive Waste Near-surface Disposal Facility (방사성폐기물 표층처분시설 통합 모니터링 시스템 개발)

  • Se-Ho Choi;HyunGoo Kang;MiJin Kwon;Jae-Chul Ha
    • Journal of Radiation Industry
    • /
    • v.17 no.4
    • /
    • pp.359-367
    • /
    • 2023
  • In this study, the function and purpose of the disposal cover, which is an engineering barrier installed to isolate the disposal vault of the near-surface disposal facility for radioactive waste from natural/man-made intrusion, and the design details of the demonstration facility for performance verification were described. The Demonstration facility was designed in a partially divided form to secure the efficiency of measurement while being the same as the actual size of the surface disposal facility to be built in the Intermediate & low-level radioactive waste disposal site of the Korea Radioactive Waste Agency (KORAD). The instruments used for measurement consist of a multi-point thermometer, FDR (Frequency Domain Reflectometry) sensor, inclinometer, acoustic sensor, flow meter, and meteorological observer. It is used as input data for the monitoring system. The 3D monitoring system was composed of 5 layers using the e-government standard framework, and was developed based on 4 components: screen, control module, service module, and DBIO(DataBase Input Output) module, and connected them to system operation. The monitoring system can provide real-time information on physical changes in the demonstration facility through the collection, analysis, storage, and visualization processes.

Consumption Patterns and Perception Analyses of Hangwa

  • Kwock, Chang-Geun;Lee, Min-A;Park, So-Hyun
    • Preventive Nutrition and Food Science
    • /
    • v.17 no.1
    • /
    • pp.71-77
    • /
    • 2012
  • Hangwa is a traditional food, corresponding to the current consumption trend, in need of marketing strategies to extend its consumption. Therefore, the purpose of this study was to analyze consumers’ consumption patterns and perception of Hangwa to increase consumption in the market. A questionnaire was sent to 250 consumers by e-mail from Oct 8~23, 2009 and the data from 231 persons were analyzed in this study. Statistical, descriptive, paired samples t-test, and importance-performance analyses were conducted using SPSS WIN 17.0. According to the results, Hangwa was purchased mainly 'for present' (39.8%) and the main reasons for buying it were 'traditional image' (33.3%) and 'taste' (22.5%). When importance and performance of attributes considered in purchasing Hangwa were evaluated, performance was assessed to be lower than importance for all attributes. The attributes in the first quadrant with a high importance and a high performance were ‘a sanitary process’, ‘a rigorous quality mark’ and ‘taste’, which were related with quality of the products. In addition, those with a high importance but a low performance were ‘popularization through advertisement’, ‘promotion through mass media’, ‘conversion of thought on traditional foods’, ‘a reasonable price’ and ‘a wide range of price’. In conclusion, Hangwa manufacturers need to diversify products and extend the expiration date based on technologies to promote its consumption. In terms of price, Hangwa should become more available by lowering the price barrier for consumers who are sensitive to price.

Evaluation of Modified Problem-Based Learning Facilitated by One Instructor (One Instructor에 의해 진행된 Modified Problem-Based Learning 교육기법 평가)

  • Kim, Hyunah
    • Korean Journal of Clinical Pharmacy
    • /
    • v.23 no.3
    • /
    • pp.278-283
    • /
    • 2013
  • Background: Problem-based learning (PBL) has introduced as an important part of pharmacy education in Korea as it is effective method to help students gain and apply knowledge with development of problem-solving, critical-thinking, and decision-making skills. In order to provide the effective PBL, a number of trained facilitators and suitable PBL rooms are required. However, these become a barrier in Korea as most pharmacy schools have one or two faculty members who majored in clinical pharmacy. Objective: This study was performed to implement and evaluate a modified PBL in gastrointestinal (GI) pharmacotherapy class facilitated by one instructor. Methods: A general information of traditional PBL for 6 hours through 3 days is introduced before initiating GI pharmacotherapy class. After 3 hour-GI pharmacotherapy classes for 6 weeks, modified PBL was implemented with one instructor to facilitate PBL for four small groups with 19 pharmacy students simultaneously. Modified PBL was incorporated with weekly mini-case discussion and presentation. Results: Students completed 15-question survey to evaluate modified PBL course, student performance, group performance, and facilitator performance. Eighty-four percent of students answered modified PBL was helpful to understand what they have learned. Mean score in group performance was higher than that of individual performance during modified PBL course. Overall, students reported modified PBL was useful in knowledge building. Conclusion: Modified PBL model without individual group facilitators in one classroom helped students to achieve self-directed, independent learning skills in an interactive and engaging environment.

Evaluation of Breaking Performance of New Contact Material for the Vacuum Interrupter (진공인터럽터용 신규 접점소재에 대한 차단 성능 평가)

  • Cha, Young-Kwang;Lee, Il-Hoi;Ju, Heung-Jin;Shin, Tae-Yong;Park, Kyong-Tae
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.34 no.1
    • /
    • pp.50-55
    • /
    • 2021
  • Copper-chromium alloys have been used as contact materials of vacuum interrupters in circuit breakers, but new materials with highly stable performance are required to break the high voltage and high current barrier due to the recent increase in breaking capacity. In this paper, a new contact material was fabricated from a ternary alloy instead of existing Cu-Cr alloys. Its breaking performance and endurance were verified from a synthetic test and compared with that of various contact materials. The test results verified that the breaking performance of the new contact material was excellent.

Numerical Simulation of Rainfall Infiltration Into Disposal Cover of Performance Test Facility

  • Mijin Kwon;Seho Choi;Chunhyung Cho
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.22 no.2
    • /
    • pp.185-199
    • /
    • 2024
  • Disposal cover as an engineered barrier of a near-surface disposal facility for low and very low-level radioactive waste is composed of a multi-layer to isolate radioactive waste from environmental influences for the long term. To acquire a realistic forecast for the post-closure period of the disposal facility, it is essential to carry out long-term experimental research in a similar condition to the actual disposal environment. Hence, a performance test facility of the disposal cover was constructed in Gyeongju low and intermediate level radioactive waste disposal center in 2022. The constructed performance test facility has differences from the material properties presented in the design. These differences are factors that affect the prevent rainfall infiltration, which is one of the important roles of the disposal cover. Therefore, in this study, a numerical simulation of rainfall infiltration into the performance test facility was performed for the designed case and the actual constructed case. To simulate the behavior of water infiltration, the FEFLOW software based on the finite element method is used. Through the analysis of numerical simulation results, it is confirmed that the hydraulic conductivity of the material constituting the multi-layer of the disposal cover greatly influences the amount of water infiltration.

An overall wind shielding program for enhancing driving stability (강풍시 도로의 주행안정성을 확보하기 위한 종합적인 방풍대책)

  • Kwon, Soon Duck;Jeong, Un Yong
    • Journal of Korean Society of Steel Construction
    • /
    • v.17 no.3 s.76
    • /
    • pp.263-270
    • /
    • 2005
  • This paper presents a program for protecting vehicles against side winds on highways. The present study consists of three processes. The first one involves giving a guideline for evaluating driving safety in high winds. The second one involves making a guideline for determining the necessity of wind protection system for a certain road area. A reasonable procedure is suggested based on the probability model of wind data on weather stations and the correction of local topographical conditions. The third one involves design of wind barriers. Both CFD analyses and wind tunnel tests were performed to find the proper type of wind barrier considering vehicle controllability, structural safety, economical efficiency as well as driver's visibility. Performance of the designed wind fences was verified from field tests. The performance of the four different types of wind barrier installed at the elevated bridge were tested and some of the results were provided.

Crashworthiness Evaluation of Bridge Barriers Built with Hot-dip Zinc-aluminium-magnesium Alloy-coated Steel (고내식성 용융합금도금강판 적용 교량난간의 충돌성능 평가)

  • Noh, Myung-Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.3
    • /
    • pp.171-176
    • /
    • 2016
  • This paper proposes road safety facilities applying Hot-dip zinc-aluminum-magnesium alloy-coated steel sheets and coils to reduce the loss of function caused by the corrosion of steel in the service state. Vehicle crash simulations and full-scale crash tests were carried out to provide reliable information on evaluating the crash performance with the products of road safety facilities built with hot-dip zinc-aluminum-magnesium alloy-coated steel. From the results of the simulations and full-scale crash tests, the impact behaviors evaluated by the three-dimensional crash simulations considering the strain-rate dependency in a constitutive model were similar to those obtained from the full-scale crash test results. The full-scale crash test results met the crashworthiness evaluation criteria; hence, the proposed bridge barrier in this paper is ready for field applications.

The Effect of Case Management for Clients with Hypertension.DM Registered in Customized Home Visiting Health Care Services (일 지역 맞춤형 방문건강관리사업의 고혈압.당뇨병 사례관리 효과분석)

  • Park, Jeong-Sook;Oh, Yun-Jung
    • Journal of Korean Public Health Nursing
    • /
    • v.24 no.1
    • /
    • pp.135-150
    • /
    • 2010
  • Purpose: To analyze the effects of customized home visiting health services on the health and health behaviors of clients with hypertension (n=107) and diabetes mellitus (DM: n=67). Methods: A one group pre and post-test research design was used. The subjects were registered in a customized 8-week, interventional, home visiting health services available in Daegu. Data was collected from November 17, 2008 to January 23, 2009. Analyses involved descriptive statistics, $x^2$ test and paired t-test. Result: Hypertension control rate was improved 25.2% and DM control rate was improved 3.0%. There were significantly beneficial hypertension-related differences in BP, health belief, health knowledge and health behaviors including performance of 10 min of moderate exercise, diet, BP monitoring and medication. Significantly beneficial DM-related changes included glucose, health belief, health knowledge and health behaviors including performance of 10 min of moderate exercise and glucose monitoring. But there were no significant hypertension-related differences in health belief (barrier) and health behavior including drinking and exercise length/frequency. Also, no significant DM-related differences were evident in health belief (barrier) and health behaviors including drinking, smoking, exercise length/frequency, diet and medication. Conclusion: Customized home visiting health service can provide effective, but not complete. Whether these benefits are maintained in the longer term is unknown.