• Title/Summary/Keyword: balanced output

Search Result 199, Processing Time 0.022 seconds

Comprehensive Coordinated Control Strategy of Virtual Synchronous Generators under Unbalanced Power Grid

  • Wang, Shuhuan;Han, Li;Chen, Kai
    • Journal of Power Electronics
    • /
    • v.19 no.6
    • /
    • pp.1554-1565
    • /
    • 2019
  • When grid voltage is unbalanced, the grid-connected output current and power of Virtual Synchronous Generators (VSGs) are distorted and quadratic. In order to improve the power quality of a grid connected to a VSG when the grid voltage is unbalanced, a comprehensive coordinated control strategy is proposed. The strategy uses the positive sequence current reference command obtained by a VSG in the balanced current control mode to establish a unified negative sequence current reference command analytical expression for the three objectives of current balance, active power constant and reactive power constant. In addition, based on the relative value of each target's volatility, a comprehensive wave function expression is established. By deriving the comprehensive wave function, the corresponding negative sequence current reference value is obtained. Therefore, the VSG can achieve the minimum comprehensive fluctuation under the premise that the three targets meet the requirements of grid connection, and the output power quality is improved. The effectiveness of the proposed control strategy is verified by simulation and experimental results.

A Study of the Fluid Balance of the Patients on Soft Diets (유동식을 섭취하는 대상자의 수분 섭취와 배설의 균형 분석)

  • 양영희;최스미;김은경;성일순
    • Journal of Korean Academy of Nursing
    • /
    • v.26 no.3
    • /
    • pp.688-696
    • /
    • 1996
  • The purpose of this study was to investigate the fluid balance of the patients who were either on soft fluid diet or total parenteral nutrition. We studied 19 patients with neurologic disorders and 22 patients with oromaxillary surgery who were admitted to either D university hospital in Choognam or S general hospital in Seoul between May and November 1995. The mean age for the patients who had oromaxillary surgery was 24 years and their average hospital stay was 9 days. The mean age of the patients with neurologic disorders was 54 years and they were bedridden for average of 71 days. For the maxillary bone surgery patients we did not limit the range of their activities in the ward during data collection period. The patients with neurological disorders were bedridden and did not move around the ward. They were all either on soft fluid diet, or total parenteral nutrition. The findings of this study are as follows ; 1) The difference of the triceps skinfold thickness between the baseline and the final measurement was 0.4cm for neurologic patient group and 0.5cm for oromaxillary surgery patient group. The difference was not statistically significant in each group. 2) In the oromaxillary surgery patient group, the daily intake of fluid in the form of pure water, other beverages, fluid diet as well as IV fluid was 4581m1 while urine output was 2979ml. The difference between fluid intake and output was statistically significant, indicating that fluid intake was far more than urine output. In neurologic patient group, the daily intake of fluid including water from fluid diet and IV fluid was 2701m1 whereas urine output was 2253m1 and they were statistically significant. 3) For a more accurate assessment we adjusted the fluid balance based on weight changes during data collection period. In the oromaxillary surgery patient group. the difference between fluid intake and output was 1238m1 after weight changes being adjusted. The difference was statistically significant, suggesting fluid overload in this patient group. In neurologic patient group, the difference between fluid intake and output considering weight changes was 124ml. The difference was not statistically significant, suggesting that the fluid intake and output was well balanced in this patient group.

  • PDF

A Hybrid SVM Classifier for Imbalanced Data Sets (불균형 데이터 집합의 분류를 위한 하이브리드 SVM 모델)

  • Lee, Jae Sik;Kwon, Jong Gu
    • Journal of Intelligence and Information Systems
    • /
    • v.19 no.2
    • /
    • pp.125-140
    • /
    • 2013
  • We call a data set in which the number of records belonging to a certain class far outnumbers the number of records belonging to the other class, 'imbalanced data set'. Most of the classification techniques perform poorly on imbalanced data sets. When we evaluate the performance of a certain classification technique, we need to measure not only 'accuracy' but also 'sensitivity' and 'specificity'. In a customer churn prediction problem, 'retention' records account for the majority class, and 'churn' records account for the minority class. Sensitivity measures the proportion of actual retentions which are correctly identified as such. Specificity measures the proportion of churns which are correctly identified as such. The poor performance of the classification techniques on imbalanced data sets is due to the low value of specificity. Many previous researches on imbalanced data sets employed 'oversampling' technique where members of the minority class are sampled more than those of the majority class in order to make a relatively balanced data set. When a classification model is constructed using this oversampled balanced data set, specificity can be improved but sensitivity will be decreased. In this research, we developed a hybrid model of support vector machine (SVM), artificial neural network (ANN) and decision tree, that improves specificity while maintaining sensitivity. We named this hybrid model 'hybrid SVM model.' The process of construction and prediction of our hybrid SVM model is as follows. By oversampling from the original imbalanced data set, a balanced data set is prepared. SVM_I model and ANN_I model are constructed using the imbalanced data set, and SVM_B model is constructed using the balanced data set. SVM_I model is superior in sensitivity and SVM_B model is superior in specificity. For a record on which both SVM_I model and SVM_B model make the same prediction, that prediction becomes the final solution. If they make different prediction, the final solution is determined by the discrimination rules obtained by ANN and decision tree. For a record on which SVM_I model and SVM_B model make different predictions, a decision tree model is constructed using ANN_I output value as input and actual retention or churn as target. We obtained the following two discrimination rules: 'IF ANN_I output value <0.285, THEN Final Solution = Retention' and 'IF ANN_I output value ${\geq}0.285$, THEN Final Solution = Churn.' The threshold 0.285 is the value optimized for the data used in this research. The result we present in this research is the structure or framework of our hybrid SVM model, not a specific threshold value such as 0.285. Therefore, the threshold value in the above discrimination rules can be changed to any value depending on the data. In order to evaluate the performance of our hybrid SVM model, we used the 'churn data set' in UCI Machine Learning Repository, that consists of 85% retention customers and 15% churn customers. Accuracy of the hybrid SVM model is 91.08% that is better than that of SVM_I model or SVM_B model. The points worth noticing here are its sensitivity, 95.02%, and specificity, 69.24%. The sensitivity of SVM_I model is 94.65%, and the specificity of SVM_B model is 67.00%. Therefore the hybrid SVM model developed in this research improves the specificity of SVM_B model while maintaining the sensitivity of SVM_I model.

DC Motor Drive with Circuit Balancing Technique to Reduce Common Mode Conducted Noise

  • Jintanamaneerat, Jintanai;Srisawang, Arnon;Prempraneerach, Yothin
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.1881-1884
    • /
    • 2003
  • In some requirements of dc motor drive circuit applications are high quality output with generation of low internal conducted EMI. However the conventional dc motor drive circuits have been usually using unbalanced circuit which generates the high conducted EMI to the frame ground. This paper presents a balanced dc motor drive circuit which is effective way to reduce the common-mode noise. The circuit balancing is to make the noise pick up or occurring in both conductor lines, signal path and return path is equal in amplitude and opposite phase so that it will cancel out in the frame ground. The common-mode conducted noise reduction of this proposed dc motor drive is confirmed by experimental results.

  • PDF

Experimental Realization of Matrix Converter Based Induction Motor Drive under Various Abnormal Voltage Conditions

  • Kumar, Vinod;Bansal, Ramesh Chand;Joshi, Raghuveer Raj
    • International Journal of Control, Automation, and Systems
    • /
    • v.6 no.5
    • /
    • pp.670-676
    • /
    • 2008
  • While the matrix converter has many advantages that include bi-directional power flow, a size reduction, a long lifetime, and sinusoidal input currents, it is vulnerable to the input voltage disturbances, because it directly exchanges the input voltage to the output voltage. So, in this paper, a critical evaluation of the effect of various abnormal voltage conditions like unbalanced power supply, balanced non-sinusoidal power supply, input voltage sags and short time blackout of power supply on matrix converter fed induction motor drives is presented. The operation under various abnormal conditions has been analyzed. For this, a 230V, 250VA three phase to three phase matrix converter (MC) fed induction motor drive prototype is implemented using DSP based controller and tests have been carried out to evaluate and improve the stability of system under typical abnormal conditions. Digital storage oscilloscope & power quality analyzer are used for experimental observations.

Phase angle control techniques of single-phase AC voltage controller for preheating (예열용 단상교류전압제어기 위상 제어 기법)

  • Hyun, J.S.;Chun, T.W.;Lee, H.H.;Kim, H.G.;Nho, E.C.
    • Proceedings of the KIPE Conference
    • /
    • 2016.07a
    • /
    • pp.393-394
    • /
    • 2016
  • A single-phase ac voltage controller controls the magnitude of ac voltage by regulating the delay angle of the input ac voltage. In this paper, the SCR gate signal generation is digitalized by using AVR, and the delay angle control technique is proposed in order to generate a balanced ac output voltage under unbalanced ac input voltage conditions.

  • PDF

Analytical Study of the Machine Dynamics of the Amplidyne Under the Demagnetization Effect (계산기에 의한 회전형전자증폭기의 동특성 및 감자작용 영향에 관한 해석적 연구)

  • Se Hoon Chang
    • 전기의세계
    • /
    • v.22 no.1
    • /
    • pp.9-19
    • /
    • 1973
  • This paper is for the supplementary studies of the theoretical treaties on the machine dynamics of the amplidyne generator under the influencies of the armature reaction. The author has already shown the time-domain expression of the dynamic relations of the machine with balanced control winding, under this operating condition. In this paper, analytical and experimental studies of a test machine are intended to supplement the theories derived in the previous work, entitled "On the dynamics and the demagnetization effect of the amplidyne generator with auxiliary feedback compensating winding". FACOM 230 digital computer is incorporated for processing of a series of experimental data. The machine dynamics are then numerically analyzed with the aid of the computer. The virtual machine responses to stepwise inputs are compared with the computer output to confirm the influence of the armature reaction effect on to the machine dynamics. dynamics.

  • PDF

A New Scheme for Maintaining Balanced DC Voltages in Static Var Compensator(SVC) (직렬형 멀티레벨 인버터를 사용한 무효전력보상장치의 새로운 직류전압 평형기법)

  • Min, Wan-Ki;Min, Jun-Ki;Choi, Jae-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2003.07e
    • /
    • pp.144-148
    • /
    • 2003
  • This paper examines the application of high voltage static var compensator(SVC) with cascade multilevel inverter which employs H-bridge inverter(HBI). To improve the unbalanced problem of the DC capacitor voltages, the rotated switching scheme of fundamental frequency is newly used. The optimized fundamental switching pattern with low switching frequency is adapted to be suitable for high application. The selective harmonic elimination method(SHEM) allows to keep the total harmonic distortion(THD) low in the output voltage of multilevel inverter. The SVC system is modeled using the d-q transform which calculates the instantaneous reactive power. This model is used to design a controller and analyze the SVC system. Simulated and experimental results are also presented and discussed to validate the proposed schemes.

  • PDF

A Study On the OJT Program deveopment of the tourism educational institution in the University (대학에서 관광교육제도의 OJT 프로그램 개발에 관한 연구)

  • Jin, Yang-Ho
    • Culinary science and hospitality research
    • /
    • v.7 no.1
    • /
    • pp.5-33
    • /
    • 2001
  • At present, the students majoring in tourism approach theoretically and practically target human resource development which is balanced between creativity and specialty. and yet, the initial step of on-the-job training has not been worked and the area of tourism and experience in this field are known as a begining stage. this study is focusing on the on-the job training in the area of tourism major in university. To solve the problems and to get rid of these weakpoint, the cooperative institution controling the tourism educational institution in the University. On top of that, some useful measures should be taken. The improved educational programs, appropriate curriculum, proper supervision for the trainees, correlation with school learningand on-the-job training, and flow of human resources between input levels and output levels. Hereafter finer and better study of this subject will be hopefully continued.

  • PDF