• 제목/요약/키워드: balance of plant

검색결과 432건 처리시간 0.023초

과열기와 과열저감기에 대한 모델링 및 파라미터 추정 (Modeling and Parameter Estimation of Superheater and Desuperheater)

  • 이순영;신휘범
    • 전기학회논문지
    • /
    • 제59권11호
    • /
    • pp.2012-2015
    • /
    • 2010
  • In this paper, the mathematical models of the superheater and the desuperheater are derived based on the fundamental laws of physics, mass and energy balance. The parameters of the models are developed for the 500[MW] thermal power plant using the actual data. The simulated model outputs are well matched with the actual ones. It is expected that the proposed models are useful for the temperature controller design of the thermal power plant.

Effects of Dual Task Training on Balance and Functional Performance in High School Soccer Players with Functional Ankle Instability

  • Kwak, Kwang-Il;Choi, Bum-Jin
    • The Journal of Korean Physical Therapy
    • /
    • 제28권4호
    • /
    • pp.254-258
    • /
    • 2016
  • Purpose: This study was conducted to identify the effects of dual task training on balance and functional performance in high school soccer players with functional ankle instability. Methods: Twenty high school soccer players with functional ankle instability were randomly assigned to a single task training group and a dual task training group. One participant who did not participate regularly in the training was excluded. The single task training group (n=9) received balance training on an unstable surface. The dual task training group (n=10) received balance training on an unstable surface and had to catch thrown balls during the balance training. Both groups were trained for 4 weeks, 3 days a week. The balance and functional performance of both groups was measured before and after training. Balance was measured using an anterior-posterior and medio-lateral balance. Functional performance was measured based on a figure-of-8 hop test, up-down hop test, and a single hop test. All data were analyzed by repeated two-way ANOVA tests. Results: A time by group interaction effect was not observed in the medio-lateral balance test, figure-of-8 hop test, or single hop test (p>0.05). A time by group interaction effect was observed in the anterior-posterior balance and up-down hop test (p<0.05). Conclusion: These results suggest that dual task training improved balance and functional performance better than single task training for some items.

발전소 복수기 배열회수의 지역난방 및 연료라인 예열용 활용타당성 검토 (Feasibility Study on Thermal Power Plant Condenser Heat Recovery for District Heating and Fuel Line Preheating)

  • 정훈;황광원
    • 신재생에너지
    • /
    • 제5권3호
    • /
    • pp.40-48
    • /
    • 2009
  • Recovered heat has been considered as a renewable energy in Europe since 2008 because its great effect on energy saving and carbon decreasing in plant process. Energy saving and decreasing green gas are critical issue today, so various technologies to save energy and decrease carbon dioxide in plant process have been applied to many industrial area. In this paper, the feasibility of condenser heat recovery by heat pump in power plant for district heating and fuel line preheating were reviewed by verifying energy (heat) balance and mass balance of power plant model. Some ways to compose proper system to recover heat of condenser are suggested and their possibilities are also reviewed. Limitations on heat recovery in power plant are also reviewed. The results are verified by calculating input/output energy based on actual performance test data of Taean Thermal Power Plant in Korea. There is noticeable improvement of plant performance in some cases which demand low temperature (<100 C) heat like distrcit heating, fuel line heating, and so forth.

  • PDF

열정산과 적용사례 조사에 의한 제강 전기로용 조연버너 적용 타당성 연구 (Validity Study on Installation of a Combustion Burner for Electric Arc Furnace in Steel Making Plant by the Heat Balance Check and Case Study)

  • 김현진;허진혁;문승재;유호선
    • 플랜트 저널
    • /
    • 제6권1호
    • /
    • pp.71-75
    • /
    • 2010
  • In this study, the validity study has been carried out to apply the combustion burner in an electric arc furnace. The validity of applying the combustion burner has been studied in the aspect of the operation through the calculation of heat balance. The average decrease rate of power on time is 11.2%. When the maintainability is compared to the door lance manipulator type, the multi-functional combustion burner is simple to replace and repair. The location of burner can be adopted according to the drawings which are recommended in this study. As a result, the validity of applying the combustion burner to improve an efficiency of electric arc furnace has been confirmed.

  • PDF

신형경수로(APR1400)의 터빈 싸이클 열성능 분석 (Turbine Cycle Thermal Performance Analysis of Advanced Power Reactor 1400)

  • 정대율;임혁순;정대욱;허균영
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집D
    • /
    • pp.343-347
    • /
    • 2001
  • Advanced Pressurized Reactor 1400(APR-1400), which is a standard evolutionary advanced light water reactor(ALWR), has been developed from 1992 as one of long-term Government Project(G-7). The APR-1400 is designed to operate at the rated output of 4000MWt to produce an electric power output of around 1450MWe. The balance of plant (BOP) for the secondary system consists of main steam, feedwater, condensate, turbine generator and auxiliary system. In this paper, we describe the major design features of secondary component, balance of plant configuration, and then the turbine cycle thermal performance evaluation using PEPSE code.

  • PDF

PERUPS (PERFORMANCE UPGRADE SYSTEM) FOR ON-LINE PERFORMANCE ANALYSIS OF A NUCLEAR POWER PLANT TURBINE CYCLE

  • KIM SEONGKUN;CHOI KWANGHEE
    • Nuclear Engineering and Technology
    • /
    • 제37권2호
    • /
    • pp.167-176
    • /
    • 2005
  • We developed the PERUPS system to aid the on-line performance analysis for the turbine cycle of the YongGwang 3 and 4 nuclear power plants. Procedure of measurement validation is included in the performance calculation to obtain heat balance. Precision of on-line performance calculation is increased via practical modifications of standard calculation algorithms based on the PTC (Performance Test Code). The proposed system also provides useful Web-based aids for performance analysis, including performance data management, a graphic viewer for heat balance and turbine expansion lines, and synthesized reports of performance.

용융탄산염연료전지 및 주변기기의 동적시뮬레이션 (Dynamic Simulation of Molten Carbonate Fuel Cell and Mechanical Balance of Plant)

  • 성태홍;김경천
    • 대한기계학회논문집B
    • /
    • 제38권2호
    • /
    • pp.121-128
    • /
    • 2014
  • 본 연구의 목적은 용융탄산염연료전지와 같은 고온연료전지에 동반하는 기계적 주변기기의 타당성을 검토할 수 있는 동적 시뮬레이션 모델을 개발하는 것이다. 연료전지를 운송수단과 같은 독립적인 동력기관에서 사용하기 위해서는 동반하는 기계적 주변기기를 최적화 및 소형화할 필요가 있다. 본 연구에서는 유입가스의 조성, 압력, 유량 및 스택의 온도에 따른 용융탄산염연료전지 내부의 화학반응의 동적 모델링을 구현하고 정상상태 시뮬레이션을 수행하여 실험결과와 비교 분석하였다. 또 연료전지의 전류밀도 제어에 따른 on/off 시뮬레이션을 수행하여 동적 시뮬레이션 모델의 타당성을 분석하였다.

Reactivity balance for a soluble boron-free small modular reactor

  • van der Merwe, Lezani;Hah, Chang Joo
    • Nuclear Engineering and Technology
    • /
    • 제50권5호
    • /
    • pp.648-653
    • /
    • 2018
  • Elimination of soluble boron from reactor design eliminates boron-induced reactivity accidents and leads to a more negative moderator temperature coefficient. However, a large negative moderator temperature coefficient can lead to large reactivity feedback that could allow the reactor to return to power when it cools down from hot full power to cold zero power. In soluble boron-free small modular reactor (SMR) design, only control rods are available to control such rapid core transient. The purpose of this study is to investigate whether an SMR would have enough control rod worth to compensate for large reactivity feedback. The investigation begins with classification of reactivity and completes an analysis of the reactivity balance in each reactor state for the SMR model. The control rod worth requirement obtained from the reactivity balance is a minimum control rod worth to maintain the reactor critical during the whole cycle. The minimum available rod worth must be larger than the control rod worth requirement to manipulate the reactor safely in each reactor state. It is found that the SMR does have enough control rod worth available during rapid transient to maintain the SMR at subcritical below k-effectives of 0.99 for both hot zero power and cold zero power.

3MW급 연료전지용 EBOP의 병렬제어 알고리즘 (A parallel control algorithm of 3MW EBOP for Molten Carbonate Fuel Cell(MCFC) power plant)

  • 황태식;김형수;김윤현;김광섭
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2009년도 정기총회 및 추계학술대회 논문집
    • /
    • pp.120-122
    • /
    • 2009
  • 발전용 연료전지 시스템은 수소와 산소를 공급받아 직류전기와 열로 변화시키는 연료전지 스택, 연료전지 스택에 연료와 공기를 공급해주는 MBOP(Mechanical Balance Of Plant), 연료전지의 출력을 계통에 연계시키는 EBOP(Electrical Balance Of Plant)로 구성된다. EBOP 시스템은 병렬 연결된 1.5MW PCU(Power Conversion Unit)로 구성되며, 각 PCU는 750kW 인버터가 병렬로 구성된다. 본 논문에서는 4병렬로 구성된 3MW급 연료전지용 EBOP의 병렬제어 알고리즘을 소개한다. 제안한 병렬제어 알고리즘은 과도응답이 빠르고 순환전류가 없는 제어특성을 가진다. 그리고 시뮬레이션과 실험으로 제안한 알고리즘의 성능을 확인한다.

  • PDF

파라미터 보간법을 이용한 3MW급 MCFC 시스템의 정상 및 비정상 상태 설계 (Steady and Dynamic Modeling of 3MW MCFC System Conceptual Design Using Parameter Interpolation Method)

  • 김민기;조인정;김윤미;강민관;이상훈;김재식
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2010년도 추계학술대회 초록집
    • /
    • pp.87.2-87.2
    • /
    • 2010
  • The steady and dynamic process model for an internal reforming molten carbonate fuel cell power plant is discussed in this paper. The dominant thermal and chemical dynamic processes are modeled for the stack module and balance-of-plant, including cathode gas preparation, heat recovery, heat loss (Each heat loss amount for the stack and MBOP is obtained from real plant data) and fuel processing. Based on dynamic model and control demand, PID controllers are designed in the whole system. By applying these controllers we can obtain temperature balance of stack and control system depending on changing steam to carbon ratio, air feed amount, and transient condition.

  • PDF