• Title/Summary/Keyword: balance measurement system

Search Result 180, Processing Time 0.034 seconds

An Experimental Study for Construction of Aerodynamic Database of the Commercial Propeller (상용 프로펠러 공력 데이터베이스 구축을 위한 실험적 연구)

  • Shim, HoJoon;Kim, Geon-Hong;Cheon, HyeJin
    • Journal of Aerospace System Engineering
    • /
    • v.15 no.5
    • /
    • pp.60-71
    • /
    • 2021
  • Propeller performance measurement system for commercial propeller was designed and applied to the wind tunnel test for 3 commercial propeller models with diameters of 30 inch. The thrust and torque of the propeller was directly measured by using 6-components balance installed on the rotating axis. The measurement system was validated by using wind tunnel balance calibration equipment. Propeller test stand including measurement and rotating system was validated by using QTP propeller. In the hovering condition, we compared the performance test results and the specifications of the commercial propeller provided by the manufacturer and confirmed that there are differences in the thrust and the torque. We measured the propeller performance with various wind speeds, propeller models and angles of attack and was summarized by thrust coefficients. We confirmed that the trend of the thrust coefficients was different in the low angle of attack and high angle of attack. An aerodynamics database that can be used for future aerodynamic design of an unmanned aerial vehicle was secured.

Effects of Virtual Reality-Based Exercise on Balance, Gait, and Falls Efficacy in Patients with Parkinson's Disease: A pilot study (가상현실 기반 운동이 파킨슨병 환자의 균형, 보행 및 낙상효능감에 미치는 영향: 예비연구)

  • Kim, Yonggyun;Kang, Soonhee
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.4 no.2
    • /
    • pp.1-11
    • /
    • 2016
  • Purpose : The purpose of this study was to identify whether virtual reality-based exercise could improve on balance, gait and fall efficacy in patients with Parkinson's disease. Methods : Ten patients with Parkinson's disease were randomly divided into either an experimental or control group. The experimental subjects performed vertual reality-based exercise, whereas the control subjects performed conventional physical therapy for 4 weeks. The balance, gait and fall efficacy of all subjects were assessed by using the Measurement Training and Documentation (MTD) balance system, force platform system, Korean version of Berg Balance scale (K-BBS), 6 Minute Walk Test (6MWT), and Korean version of Fall efficacy scale (K-FES) at pre training and post training. Wilcoxon signed rank test was used to analyze change before and after intervention in intra-group. Mann Whitney U test was used to analyze changes of all variables in inter-groups. Results : Subjects in the experimental group showed significant improvements in difference of weight distribution, K-BBS scores, antero-posterior and medio-lateral sway length, ground reaction force (GRF), 6MWT, and step length following training. The changes of difference of weight distribution, K-BBS scores, AP Sway Length, GRF, 6MWT, step length and K-FES scores in the experimental group were significantly more than them of the control group. Conclusion : The result of this study suggest that virtual reality-based exercise training is an intervention to improve on balance, gait, and falls efficacy in patients with Parkinson's disease.

Effects of a Newly Designed Pelvic Belt Orthosis on Functional Mobility of Adults with Post-Stroke Hemiparesis

  • Cho, Byeong-Mo;Zarayeneh, Neda;Suh, Sang C.
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.8 no.4
    • /
    • pp.125-131
    • /
    • 2020
  • Purpose : Lower extremity orthoses have been used as conservative methods to recover gait of the stroke patients. The purpose of this study is to examine how newly designed pelvic belt orthosis can improve gait ability and dynamic balance of adults with Hemiparesis after stroke. Methods : 22 patients who had hemiparesis after stroke participated in this study. Two groups were randomly created by assigning 10 subjects to the experimental group and the rest of the 12 subjects to the control group. The control group was treated by conventional physical therapy and occupational therapy. Identical therapy protocols were used to treat the experimental group who were assigned to wear the pelvic belt orthosis during post measurement. This study has a group of independent variables including group, gender, age, height, MAS, lesion side, cause and a group of dependent variables including gait speed, cadence, step length, stride length, and dynamic balance. The GAITRite system was used to measure spatial-temporal gain parameters and the balance system SD to measure dynamic balance. The data was analyzed using R version 3.3.1. Random forest, boosting algorithm, and MANOVA test were conducted to determine the effects of independent variables on dependent variables. Results : This study has a group of independent variables including group, gender, age, height, MAS, lesion side, cause and a group of dependent variables including gait speed, cadence, step length, stride length, and dynamic balance. The independent variable "group" has the most important value, which is approximately 25.42 (%IncMSE) representing a value three times greater than the second important predictor "height." Conclusion : As a result of this research, the hypothesis is validated with conclusion that Pelvic Belt orthosis could be effectively used for improving gait ability and balance of the patients with post-stroke hemiparesis.

Design of Ball and Plate Robot controller using Single Camera (단일 Camera를 이용한 Ball and Plate 로봇 제어장치 설계)

  • Park, Yi-Keun;Park, Ju-Youn;Park, Seong-Mo
    • Journal of Korea Multimedia Society
    • /
    • v.16 no.2
    • /
    • pp.213-225
    • /
    • 2013
  • This paper proposes a design method of ball-plate robot controller using single camera and two motors to balance the ball on plate and reduce steady state control error. To design the ball-plate system, it is necessary to observe state of the ball and maintain balance of the plate. The state of the ball is tracked by using the CAMShift algorithm and position error of the ball is compensated by the Kalman filter. Balance of the plate is controlled by driving two motors and we used DC motors which has smaller measurement error. Due to surface condition of the plate or tracking error of ball's position, there are small errors remained. These errors are accumulated and disturb maintaining balance of the ball. To handle the problem, we propose a controller supplemented with an integrator.

Performance Evaluation of Balance Ability Equipment Using VR (VR을 이용한 균형능력 측정장비의 성능평가)

  • Yoon, Sangcheol;An, Howon;Ahn, Taekwon;Choi, Haesung;Lee, Byoungkwon;Seo, Dongkwon;Lee, Kyuhwan;Jung, Sangwoo;Yi, Jaehoon
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.8 no.3
    • /
    • pp.33-41
    • /
    • 2020
  • Purpose : Conventional Balance Measurement can only measure the center of gravity and the shaking movement of the body. As a result, it has the disadvantages of not responding to visual changes and blocking functions of variables. This study was carried out to evaluate the performance of new equipment that measures the balance of the body using changes in body segment and pressure using the acceleration sensor to compensate for the disadvantages of the existing equipment. Methods : To this end, balance ability was measured in 43 healthy male/female adults without orthopedic injuries and nervous system damage in the last 6 months. in a situation where the visual information was restricted by Virtual Reality (VR) gear, all subjects measured and evaluated the balance ability utilizing the new equipment. Balance measurement (Prime Medilab, Korea) and Wii fit (Nintendo, Japan) were used to measure the balance ability of the subjects, and the balance ability test was performed in 4 postures using each device for data acquisition. The test duration for each posture was 30 seconds. For data acquisition, the average value of three experiments measured using each equipment was analyzed, and the statistical test was performed using the independent sample and the corresponding sample t-test, and the significance level was set to α=.05. Results : As a result of measuring the balance ability using individual equipment, blocking visual information using VR gear, the average speed, maximum speed, and moving area of the COP increased equally. It was found that the obtained absolute size of the result in Wii was somewhat larger than that of BM. Conclusion : It is considered that in the future research, it is necessary to measure changes in the body's center of gravity through image analysis, etc., to make clear comparison and evaluation of the usability.

Iron Deficiency Anemia Cases Managed by Yinyang Balance Appliance of FCST, a TMJ Therapy for the Balance of Meridian and Neurological System (FCST의 음양균형장치를 활용한 철결핍성 빈혈의 증례보고)

  • Lee, Sang-Bae;Lee, Young-Jun
    • Journal of TMJ Balancing Medicine
    • /
    • v.3 no.1
    • /
    • pp.23-26
    • /
    • 2013
  • Objectives: Therapeutic effect of Yinyang Balancing Appliance of functional cerebrospinal therapy (FCST) for meridian and neurologic yinyang balance was observed in Iron Deficiency Anemia. Methods: One Iron Deficiency Anemia cases were managed with the Yinyang Balancing Appliance on temporomandibular joint (TMJ), combined with acupuncture. Clinical outcome measurement was based on subjective measures and clinical observations. Results: The patients showed positive changes even after the initial treatment and this effext maintained over the follow-up period. Conclusions: Although it is not clear the effect is a sustaining or temporary in its nature, a positive effect was observed and further clinical and biological research on FCST is expected.

  • PDF

Selection of Fuel/Air feeders in BOP system for a DMFC (직접메탄올 연료전지 BOP 시스템에서 연료/공기 공급 장치의 선정)

  • Kim, Ki-Wong;Kim, Seo-Young;Kang, Byung-Ha
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2008.03b
    • /
    • pp.248-251
    • /
    • 2008
  • The objective of this study is to select fuel/air feeders for reliable operation of BOP(Balance of Plant) system for a DMFC (direct methanol fuel cell). A 42-cell 50W DMFC stack is considered for performance comparison of selected fuel pumps and air blowers. The present stack has two serpentine anode channels with depth of 1.2 mm and rib of 1 mm and one serpentine cathode channel with depth of 1.5 mm and rib of 1 mm. The pressure drop through the stack is estimated in advance by utilizing the pre-existing loss coefficients data for various flow configurations. Then the operating points of feeders are determined at the balance point of the flow impedance curves for the channels in the DMFC stack and the selected pump and blower performance curves. After estimating the operating flow rates in the anode and cathode channels, the flow measurement with the selected feeders is performed for the comparison with the estimated flow rates. The measured results show that the discrepancy between the estimation and the measurement for the cathode is about 26%, about 3% for the anode

  • PDF

The Effects of Transverse Abdominis Ratio and Balance Ability during Bridge Exercises on Different Support Surface (지지면 변화에 따른 교각운동이 복횡근 두께와 균형능력에 미치는 영향에 관한 연구)

  • Ann, Jun-il;Kim, Yoon-hwan;Park, Jong-hang;Ann, Mi-rae;Jung, Yeon-woo;Kim, Tae-won
    • The Journal of Korean Academy of Orthopedic Manual Physical Therapy
    • /
    • v.23 no.1
    • /
    • pp.23-30
    • /
    • 2017
  • Purpose: The purpose of this study was to investigate the effect of transverse abdominis ratio and balance ability during bridge exercises on different support surface. Methods: The subjects were 20 students at G University. Ultrasound equipment was used to measure the transverse abdominisratio and the computerized balance measurement equipment was used to measure the balance ability before and after bridge exercises on different support surface. Results: Transverse abdominis ratio change between the groups was a significant difference only in the unstable support surface training group (p<.05). Normal standing eye close balance ability change between the groups was significantly different only in the unstable support surface training group (p<.05). The changes in the transverse abdominis ratio after 7 days of exercise and 14 days after exercise were significantly different between the groups (p<.05). Normal standing eye close balance ability showed a significant difference at 7 days after exercise and 14 days after exercise (p<.05). Conclusions: It is more effective to balance ability and ratio of the transverse abdominis when bridge exercises on an unstable support surface than to perform bridge exercises on a stable support surface. Therefore, we propose an effective program for patients with instability of the lumbar in clinical practice. bridge exercises on different support surface.

  • PDF

The Effects of Trunk Stabilization Training Emphasizing Transverse Abdominis Contraction on Static Balance and Game Records for Archers (배가로근 수축을 강조한 체간 안정화 훈련이 양궁선수들의 정적 균형 및 경기기록에 미치는 영향)

  • Lee, So-Young;Seo, Tae-Hwa;Jeong, Yeon-Woo
    • PNF and Movement
    • /
    • v.17 no.2
    • /
    • pp.283-291
    • /
    • 2019
  • Purpose: The purpose of this study was to investigate the effects of trunk stability training on static balance and game records among archers. Methods: The subjects comprised 24 voluntary archers in middle and high school (aged 14-19 years). All the subjects received trunk stability training for an hour per day 3 days a week for 4 weeks. The Tetrax balance system was used to measure the stability index of the subjects' static balance. The subjects' game records were scored using a single FITA round system. All the subjects were measured before the intervention, 2 weeks into the intervention, and 4 weeks after the intervention, with a follow-up measurement 2 weeks later. Results: The results of this study showed that the stability index was significantly different across all the measuring positions after the intervention (p<0.05). Furthermore, the results of the measurements of the standing position with eyes open and closed were significantly different before the intervention compared to 4 weeks after the intervention (p<0.05). The archery position with the head turned to the left and eyes closed was also significantly different pre-intervention compared to 2 weeks after the start of the intervention (p<0.05). Additionally, the archery records were significantly different after the intervention (p<0.05), as well as before the intervention and 4 weeks after the intervention (p<0.05). Conclusion: Trunk stability training can improve static balance in archers. It may also be helpful in improving athletic performance and maintaining the life of the athlete. Accordingly, trunk stability training may prevent and resolve injuries through careful management when playing one-side sports.

Reliability and Concurrent Validity of the Balance Evaluation using Space Balance 3D and Tinetti Mobility Test in Subacute Stroke Patients (아급성 뇌졸중 환자에서 Space Balance 3D와 Tinetti Mobility Test를 이용한 균형 능력 평가의 신뢰도 및 동시타당도 연구)

  • Choi, Ji-Min;Lee, Jong-Hoon;Ha, Hyun-Geun;Kim, Yang-Gu;Kim, Yun-Hee;Bae, Young-Hyeon
    • The Journal of the Korea Contents Association
    • /
    • v.12 no.8
    • /
    • pp.264-273
    • /
    • 2012
  • The purpose of this study was to determine the test-retest reliability and the concurrent validity between tinetti mobility test (TMT), berg balance scale (BBS) and space balance 3D which is one of the computerized measurement and visual feedback balance assessment system in subacute stroke patients. Twenty three ambulatory acute stroke subjects were measured the TMT, BBS and space balance 3D. The test-retest reliability(intra-class correlation coefficient: ICC) indicated that the static and dynamic balance in space balance 3D considered moderate reliability and TMT, BBS were good reliability. In case of concurrent validity, there were moderate validity (p<.01) between static balance test with space balance 3D and each TMT, BBS. But there were only poor validity (p<.05) between center to forward-left, center to backward-left phase in dynamic balance test with space balance 3D and each TMT, BBS. These findings suggest that in subacute stroke patients the test-retest reliability and concurrent validity using the space balance 3D and TMT were valuable in balance test but there was limitation to evaluate dynamic balance test.