• Title/Summary/Keyword: balance measurement system

Search Result 180, Processing Time 0.035 seconds

The Effect of Hallux Valgus Correction Taping on Foot Arch and Static Balance of Young Adult with Hallux Valgus

  • Son, Jun-Seob;Jo, Yeon-Ju;Kim, Suhn-Yeop
    • Journal of Korean Physical Therapy Science
    • /
    • v.24 no.3
    • /
    • pp.18-29
    • /
    • 2017
  • Purpose: The purpose of this study was to identify the effect of hallux valgus (HV) correction taping on the foot arch and balance of young adults with HV of the big toe. Methods: Forty-eight adults volunteered to participate in this study; of them, the 37 feet (11 men, 26 women) with ${\geq}15^{\circ}$ lateral bending of the metatarsophalangeal joint of the big toe, on a goniometer, were selected as the target foot. Non-elastic correction tape was applied to the foot with HV, while the target foot was used to evaluate the changes, before versus after taping, in the lateral bending angle of the big toe, navicular drop level, Clarke angle, and static balance using a Gaitview system. Each measurement was performed three times, and the average of each set was used in the analysis. The patients'general characteristics were compared by using an independent t-test, and the measurement values were analyzed by using a paired t-test. Results: After taping, the lateral bending angle of the toe significantly decreased (p<.05), difference in navicular drop level significantly decreased (p<.05), the Clarke angle significantly increased (p<.05), and static balance significantly improved (p<.05). Conclusion: We showed that HV taping resulted in an immediately improved HV angle, arch, and single-leg standing balance on the foot with HV. However, further studies should investigate the correlation between HV and foot arch.

A Technique for Accurate Measurement of Power System Frequency (전력설비의 정밀주파수진단을 위한 기법)

  • Nam, S.B.;Lee, H.G.
    • Proceedings of the KIEE Conference
    • /
    • 2006.05a
    • /
    • pp.66-70
    • /
    • 2006
  • Frequency is an important operating parameter of a power system. Electric power systems sustain transient frequency swings whenever the balance between generation and load does not no longer hold. To cope with this Constraints, il requires an accurate and high speedy frequency deviation estimation technique and suitable adjustment to obtain the power system energy balance. This paper describes the design, computational aspects and implementation of an iterative technique for measuring power system. The rate change of the phase angle is used for estimation. To confirm the validity of the proposed algorithm, the simulation studies carried out on a typical 154[KV] double T/L system by using EMTP software. Some test results are presented in the paper.

  • PDF

A Technique for Fast and Accurate Measurement of Power System Frequency (전력계통 주파수의 고속.정밀측정을 위한 기법)

  • Nam, S.B.;Lee, H.G.;Ma, S.B.
    • Proceedings of the KIEE Conference
    • /
    • 2004.07e
    • /
    • pp.68-71
    • /
    • 2004
  • Frequency is an important operating parameter of a power system. Electric power systems sustain transient frequency swings whenever the balance between generation and load does not no longer hold. To cope with this Constraints, it requires an accurate and high speedy frequency deviation estimation technique and suitable adjustment to obtain the power system energy balance. This paper describes the design, computational aspects and implementation of an iterative technique for measuring power system. The rate change of the phase angle is used for estimation. To confirm the validity of the proposed algorithm, the simulation studies carried out on a typical 154[KV] double T/L system by using EMTP software. Some test results are presented in the paper.

  • PDF

An Iterative Technique for Fast and Accurate Measurement of Power System Frequency (전력계통 주파수의 고속.정밀측정을 위한 반복기법)

  • Nam, S.B.
    • Proceedings of the KIEE Conference
    • /
    • 2003.07e
    • /
    • pp.92-95
    • /
    • 2003
  • Frequency is an important operating parameter of a power system. Electric power systems sustain transient frequency swings whenever the balance between generation and load does not no longer hold. To cope with this Constraints. it requires an accurate and high speedy frequency deviation estimation technique and suitable adjustment to obtain the power system energy balance. This paper describes the design, computational aspects and implementation of an iterative technique for measuring power system. The rate change of the phase angle is used for estimation. To confirm the validity of the proposed algorithm, the simulation studies carried out on a typical 154[KV] double T/L system by using EMTP software. Some test results are presented in the paper.

  • PDF

A Technique for Fast Measurement of Power System Frequency (전력계통 주파수의 고속측정을 위한 기법)

  • Nam, S.B.;Kim, Jin-Su;Ma, Seok-Beom
    • Proceedings of the KIEE Conference
    • /
    • 2005.10a
    • /
    • pp.145-149
    • /
    • 2005
  • Frequency is an important operating parameter of a power system. Electric power systems sustain transient frequency swings whenever the balance between generation and load does not no longer hold. To cope with this Constraints, it requires an accurate and high speedy frequency deviation estimation technique and suitable adjustment to obtain the power system energy balance. This paper describes the design, computational aspects and implementation of an iterative technique for measuring power system. The rate change of the phase angle is used for estimation. To confirm the validity of the proposed algorithm, the simulation studies carried out on a typical 154[KV] double T/L system by using EMTP software. Some test results are presented in the paper.

  • PDF

The Effects of Altered Surface conditions on Balance Ability for the Patients with Hemiplegia (치료면의 질이 편마비환자의 균형에 미치는 효과)

  • Jeong, Young-June;Youn, Jung-Ho;Kim, Gyu-Yong
    • Journal of Korean Physical Therapy Science
    • /
    • v.15 no.1
    • /
    • pp.67-74
    • /
    • 2008
  • A decrease in the ability to maintain static and dynamic balance after stroke could be related to the inability to select reliable sensory information in producing relative motor action needed to maintain postural stability. The purpose of this study was to compare the effects of two different types of surface conditions on the balancing ability of subjects with stroke. Eighteen hemiparetic subjects were assigned to an experimental and control group participating in a six-week rehabilitative therapeutic exercise program focusing on balance and mobility. Exercises were performed 3 to 5 times per week in a stable surface condition by the control group, and in an unstable surface condition by the experimental group. Pre- and post test assessments involved the measurement of the static balance and dynamic balance, respectively by 7-item Berg Balance Scale-3P and by Pro-3 Balance System. Results showed that under the unstable surface condition, static balance in the experimental group showed more improvement than that of the control group.(Statistically, not very significant.) All the aspects of dynamic balance and mediolateral sway(balance) improved significantly than those of the control group. However, there were no significant differences between two groups. Overall, it can be concluded that under the unstable surface condition, the rehabilitative therapeutic exercise programs are effective in improving the dynamic balance of stroke subjects. The results suggest that the adaptation of the unstable surface in the rehabilitative therapeutic exercises could be effective for the patients with hemiplegia in balance. Further studies are needed to confirm the effectiveness of the unstable surface on improving balance and postural stability of hemiplegics.

  • PDF

Clinical Application of AR System in Early Rehabilitation Program After Stroke: 2 Case Study

  • An, Chang Man;Kim, Dae Hyun
    • The Journal of Korean Physical Therapy
    • /
    • v.31 no.3
    • /
    • pp.141-146
    • /
    • 2019
  • Purpose: To investigate the effect of an augmented reality (AR) system on muscle strength and function level of the paretic lower limb and the balance ability in the early rehabilitation program of acute stroke patients. Methods: The participants (30 or fewer days after stroke) were randomly assigned to receive intervention with an early rehabilitation program using an AR system (n=1) or an early rehabilitation program consisting of functional electrical stimulation and tilt table use (n=1). Patients in both subjects received interventions 4-5 times a week for 3 weeks. Results: In the paretic limb muscle strength, AR subject was increased from 15 to 39.6 Nm and Control subject was increased from 5 to 30.2 Nm. The paretic limb function of AR subject motor function was increased from 8 to 28 score and Control subject motor function was increased from 6 to 14 score. But sensory function was very little difference between the two subjects (AR subject: from 4 to 10 score, Control subject: from 3 to 10 score). In the balance ability, AR subject had more difference after intervention than control subject (AR subject: 33 score, Control subject: 22 score). Conclusion: The early rehabilitation program using the AR system showed a slightly higher improvement in the motor function of the paretic lower limb and balance ability measurement than the general early rehabilitation program. The AR system, which can provide more active, task-oriented, and motivational environment, may provide a meaningful environment for the initial rehabilitation process after stroke.

Optimizing Study-life Balance within Higher Education: A Comprehensive Literature Review

  • HATCHER, Ryan;HWANG, Yosung
    • The Journal of Economics, Marketing and Management
    • /
    • v.8 no.2
    • /
    • pp.1-12
    • /
    • 2020
  • Purpose: The rise of the phrase Work Life Balance was bought up in 1986 when amid many Americans there was prevalence of detrimental work place practices like neglecting families, leisure activities and friends in order to achieve their study place goals. The significance of work-life balance has been gaining ground in recent years to grasp a wider range of groups, including students. Searching and finding a balance can be complex and challenging for many individuals and students. Research design, data and methodology: Through this paper we will explore how students balance the competing demands of work, study, and social activities. Several factors have increased imbalances within Educational organizations, and technology specifically has been influential. However, technology also provides a novel solution to this organizational performance management issue. A Study-Life Optimization model (SLO) is suggested, which incorporates information systems, analytics, and decision support into a Smart Service System. A general framework for this model, detailing data collection, measurement, and ethical issues is explained briefly. Results: Outcomes include improved WLB, greater perceived quality of life, and increased Educational organizational performance. Conclusions: This paper contributes to the relevant literature as it pays attention to the various students' of varying lifestyles school-work-personal lives. Findings of this study will provide a meaningful of the Work/school-life balance issues faced by students. The research could be helpful to the various stakeholders of a University, the curriculum designers, program coordinators etc.

Development and Evaluation of Body Surface Electric Energy Measurement System for Oriental Medical Diagnosis (한의 진단을 위한 체표에너지 측정 시스템의 개발 및 평가)

  • Kim, Soo-Byung;Kwon, Sun-Min;Kang, Hee-Jung;Yim, Yun-Kyoung;Lee, Yong-Heum
    • Korean Journal of Acupuncture
    • /
    • v.26 no.1
    • /
    • pp.51-60
    • /
    • 2009
  • Objectives : It is considered not easy to diagnose the condition of acupoints or meridians. Oriental Medical instruments have rarely complied with Oriental Medical diagnostic/therapeutic theories. The aim of this study was to develop a system which measures meridian electric potential(MEP) in proportion to bio-electric charge for the purpose of Oriental Medical diagnosis. Method : To evaluate a meridian energy measurement system(MEMS), we carried out a performance test. For significance test, we conducted a clinical trial which measured the MEP of ST36(Chok-samni) on Stomach Meridian(ST). Results & Conclusions : We could evaluate the balance or the imbalance of the MEPs on the left/right ST36. Also, through the comparison of MEPs before and after meals, we could identify the correlation between the MEP and the condition of internal organs. Namely, MEP reflects the condition of acupoints/meridians and internal organs, therefore, we propose this new method for measuring and analyzing the condition of meridians and acupoints for Oriental Medical diagnosis.

  • PDF

Mass Standards Calibration through Internet (인터넷을 이용한 표준분동 교정 활용)

  • 이우갑;정진완;김광표
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.06a
    • /
    • pp.1109-1112
    • /
    • 2003
  • Information technology has enabled mass standards calibration to be performed through internet. For this, an automatic weight handler was manufactured. During the operation the images of weight operation and the system are provided via the measurement system and a web server. The measurement system consists of a balance, a weight handler, instruments for environment measurement and a PC. The weight handler automatically loads and unloads weights on and from the weighing pan. The weight handler allows 6 series weights to be operated for weight calibration of 100-50-20-20-10-10 gram series weight. This capability could be used for "remote training" for series weight calibration.

  • PDF