• Title/Summary/Keyword: balance measurement system

Search Result 180, Processing Time 0.023 seconds

A Study on Crosstalk in High Speed Digital Signal Transmission Line (고속 디지털 신호 전송선로에서의 Crosstalk 에 관한 연구)

  • 김세영;장상건;남상식;박항구;신연강
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.31A no.8
    • /
    • pp.16-25
    • /
    • 1994
  • The prediction of crosstalk in one of important problems in estimating the EMC of a system for high speed digital signal transmission. Crosstalk curves are shown in terms of characteristic impedance of lines spacing between lines and rise time of pulse by using general multiple coupled transmission line equation and harmonic-balance method. The coupled symmetrical two-line on dielectric material epoxy-glass FR 4(${\varepsilon}_r$), is fabricated to measure crosstalk occuring at the near end and far end of the passive line. The inter-line is inserted to reduce crosstalk between two microstrip lines. The simulation results and the measurement results are shown and found to be very close.

  • PDF

Miniature planar stack using the flexible Printed Circuit Board as current collectors (연성 기판을 전류 집전체로 사용한 평판형 연료전지 스택)

  • Kim, Sung-Han;Cha, Hye-Yeon;Miesse, Craig M.;Cha, Suk-Won;Jang, Jae-Hyuk
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2008.05a
    • /
    • pp.1-4
    • /
    • 2008
  • Fuel cells have the potential of providing several times higher energy storage densities than those possible using current state-of-the-art lithium-ion batteries, but current energy density of fuel cell system is not better than that of lithium-ion batteries. To achieve the high energy density, volume and weight of fuel cell system need to be reduced by miniaturizing system components such as stack, fuel tank, and balance-of-plant. In this paper, the thin flexible PCB (Printed circuit board) is used as a current collector to reduce the stack volume. Two end plates are made from light weight aluminum alloy plate. The plate surface is wholly oxidized through the anodizing treatment for electrical insulation. The opening rate of cathode plate hole is optimized through unit cell performance measurement of various opening rates. The performances are measured at room temperature and ambient pressure condition without any repulsive air supply. The active area of MEA is 10.08 $cm^2$ and active area per a unit cell is 1.68 $cm^2$. The peak power density is about 210 mW/$cm^2$ and the air-breathing planar stack of 2 Wis achieved as a small volume of 18 cc.

  • PDF

The Effects of Carthami Semen Pharmacopuncture and Bovis Calculus.Fei Ursi Pharmacopuncture on the Heart Rate Variability(HRV) (홍화자약침과 웅담.우황약침이 심박변이도(HRV)에 미치는 영향)

  • Lee, Jin-Bok;Song, Beom-Yong;Yook, Tae-Han
    • Journal of Acupuncture Research
    • /
    • v.27 no.2
    • /
    • pp.11-21
    • /
    • 2010
  • Objectives : We tried to investigate the effects of Carthami Semen(CF) pharmacopuncture and Bovis Calculus Fei Ursi(BU) pharmacopuncture on the heart rate variability(HRV) in adult men. As well as we tried to observe how CF pharmacopuncture and BU pharmacopuncture effect on the balance of the autonomic nervous system. Methods : We investigated on 40 healthy volunteers consisted of 20 subjects in CF pharmacopuncture group and 20 subjects in BU pharmacopuncture group respectively. We ruled out subjects whose vital sign isn't in normal range, yet they had taken a rest. The study established by a randomized, single-blind clinical trial. CF pharmacopuncture and BU pharmacopuncture was applied on each group. We measured HRV 7 times : baseline measurement and every 5 minutes for 30 minutes after injection. The SPSS 15.0 for Windows was used to analyze the data by the paired t-test(in group) and Independent sample t-test(between the groups). Results 1. After injection of CF pharmacopuncture, SDNN, Ln(TP), Ln(VLF) and Ln(LF) increased significantly, and Complexity, pNN50 decreased significantly. 2. After injection of BU pharmacopuncture, RMSSD, SDSD and HRV-index increased significantly. Conclusions : We suggest that CF pharmacopuncture activate sympathetic nervous system and BU pharmacopuncture tend to activate the autonomic nervous system.

Coordinated Control Strategy for Power Systems with Wind Farms Integration Based on Phase-plane Trajectory

  • Zeng, Yuan;Yang, Yang;Qin, Chao;Chang, Jiangtao;Zhang, Jian;Tu, Jingzhe
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.1
    • /
    • pp.20-29
    • /
    • 2018
  • The dynamic characteristics of power systems become more and more complex because of the integration of large-scale wind power, which needs appropriate control strategy to guarantee stable operation. With wide area measurement system(WAMS) creating conditions for realizing realt-ime transient stability analysis, a new coordinated control strategy for power system transient stability control based on phase-plane trajectory was proposed. When the outputs of the wind farms change, the proposed control method is capable of selecting optimal generators to balance the deviation of wind power and prevent transient instability. With small disturbance on the base operating point, the coordinated sensitivity of each synchronous generator is obtained. Then the priority matrix can be formed by sorting the coordinated sensitivity in ascending order. Based on the real-time output change of wind farm, coordinated generators can be selected to accomplish the coordinated control with wind farms. The results in New England 10-genrator 39-bus system validate the effectiveness and superiority of the proposed coordinated control strategy.

Correction of Measured Traffic Volume on Expressways Using Optimization Model (최적화 모형을 이용한 고속도로 측정교통량 보정)

  • Kim, Dong ho;Park, Dong joo;Kim, Do gyeong;Shin, Seung jin
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.17 no.4
    • /
    • pp.41-53
    • /
    • 2018
  • This study developed the optimization method to correct the measured traffic volume of the expressway that minimizes the measurement error and satisfies the traffic balancing with TCS. For this purpose, the model constructed in this study was compared and verified with the true traffic volume. Verification result of the model, it was found that the measurement error is reduced when the measured traffic volume is corrected for the traffic volume balance. As a result of applying it to 40 links of the Kyoungbu expressway, the measured traffic volume was corrected by -8.1%~9.6% and the measurement error was decreased as much as the corrected traffic volume. This research is meaningful in improving the accuracy of the measured traffic volume of the expressway, while the scale and role of the expressway are increasing.

A NEW METHOD - REAL TIME MEASUREMENT OF THE INITIAL DYNAMIC VOLUMETRIC SHRINKAGE OF COMPOSITE RESINS DURING POLYMERIZATION (복합레진의 초기 동적 체적 중합수축의 실시간 측정 -새로운 측정장치의 개발에 대한 소고-)

  • 이인복
    • Restorative Dentistry and Endodontics
    • /
    • v.26 no.2
    • /
    • pp.134-140
    • /
    • 2001
  • The polymerization shrinkage of composite resins is an important drawback although the composites have many advantages-more esthetic and conservative than metallic restoratives etc. The purposes of this research were to develop a new measurement method and to manufacture an instrument that can measure the initial dynamic volumetric shrinkage of composite resins during polymerization. The instrument was basically an electromagnetic balance that constructed with a force transducer using position sensitive photo detector(PSPD) and a negative feedback servo amplifier of proportional-derivative(PD) controller. The volumetric change of composites during polymerization was detected continuously as buoyancy change in distilled water by means of Archimedes's principle. It was converted to continuous electrical voltage signal in real time. The signal was properly conditioned and filtered and then it was stored in computer by a data acquisition(DAQ) board. By using this electronic instrument. the dynamic patterns of the polymerization shrinkage of eight commercial(Z-100, DenFil, AeliteFil, Z-250, P-60, SureFil, Synergy compact, and Tetric ceram) composite resins were measured and compared. The results were as follows. 1. From this project of developing instrument, the ability has been achieved that can acquire and process data of electrical signal transformed from various physical phenomenon by using temperature, displacement. photo. and force transducer. As a consequence, the instrumentation and measurement system used to analyze the physical characteristics of various dental materials in dental research field can be designed, manufactured and implemented in lab. 2. This instrument has some advantages. It was insensible to temperature change and could measure true dynamic volumetric shrinkage in real time without complicated process. It showed accuracy and high precision results with small standard deviation. 3. The polymerization shrinkage of composites was significantly different between brands and ranged from 2.47% to 3.89%, The order of polymerization shrinkage was as follows, in order of increasing shrinkage, SureFil, P60, Z250, Z100, Synergy compact. DenFil, Tetric ceram, and AeliteFil. 4. The polymerization shrinkage rate per unit time, dVol%/dt, showed that the instrument can provide an indirect research method for polymerization reaction kinetics.

  • PDF

Evidence of Vertical Mixing Caused by High Frequency Internal Waves along the Eastern Coast of Korea

  • Han, In-Seong;Lee, Ju;Jang, Lee-Hyun;Suh, Young-Sang;Seong, Ki-Tack
    • Fisheries and Aquatic Sciences
    • /
    • v.11 no.1
    • /
    • pp.41-49
    • /
    • 2008
  • Internal waves and internal tides occur frequently along the eastern coast of Korea. During the spring-tide period in April 2003, the East Korean Warm Current (EKWC) flowed near the Korean East Coast Farming Forecast System (KECFFS; a moored oceanographic measurement system), creating a strong thermocline at the intermediate layer. Weakened stratification and well-mixed water appeared frequently around the KECFFS, with duration of approximately 1 day. The results suggest the following scenario. Baroclinic motion related to the internal tide generated high frequency internal waves around the thermocline. The breaking of those waves then created turbulence around the thermocline. After well-mixed water appeared, a current component with perpendicular direction to the EKWC appeared within the inertial period. The change in stratification around the KECFFS locally broke the geostrophic balance as a transient state. This local vertical mixing formed an ageostrophic current within the inertial period.

Implementation of the Posture Stability Monitoring System using Balance Ability Method (균형능력 측정 기법을 이용한 자세안정도 모니터링 시스템 구현)

  • Cha, Sang-Hoon;Choi, Su-Bin;Park, Eun-Ji;Park, Jun-mo;Jeong, Do-Un
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2016.05a
    • /
    • pp.537-538
    • /
    • 2016
  • Recently, modern people a lot of frequency of work and seat life by academic is increased, addictive spine for the wrong attitude and the wrong habits are many pelvic disease occurrence. Therefore, in order to induce continuous correct posture to prevent this, the system that can be induced to determine the posture information based on the seating information is requested. In this paper, when the development and inappropriate attitude of the device that is capable of tracking measurement in order to evaluate the attitude stability is detected, let your users know, to correct their attitude through the real-time monitoring It was implemented of categorize to help application.

  • PDF

Analysis of Meridians Energy change by Cupping Stimulation (부항자극에 대한 체표 경락.경혈의 생체에너지 변화 분석)

  • Kim, Soo-Byeong;Lee, Na-Ra;Kim, Young-Dae;Lim, Jong-Hyeon;Song, Gil-Soo;Jung, Byung-Jo;Lee, Yong-Heum
    • Korean Journal of Acupuncture
    • /
    • v.27 no.4
    • /
    • pp.49-57
    • /
    • 2010
  • Objectives : The aim of this study is evaluation for significance of skin meridian-acupoints energy measurement system, and is verification of principle to measure the bio-ion charge on acupoints. Methods : To check a correlation between the MEP(Meridian Energy Potential) and bio-electric charge condition, ten acupoints(left/right BL meridian : BL13, BL15, BL18, BL20, BL23) were chosen. Based on basic theory concerning the upward trend of the bio-electric charge by cupping therapy, we measured MEP change before and after 600mmHg(80kPa) Negative pressure stimulation using cupping. Results : We could identify the correlation between MEP and the condition of bio-electric charge in acupoints. Also, we checked the balance or imbalance of left/right the MEP and unusual cases. Conclusions : We confirmed significance of proposed principle and meridian energy measurement system.

System Development of a 100 kW Molten Carbonate Fuel Cell III (System Control and Operation Mode) (100 kW급 용융탄산염 연료전지 시스템 개발 III (시스템 제어 및 운전모드))

  • Lim, Hee-Chun;Ahn, Kyo-Sang;Seo, Hai-Kyung;Eom, Yeong-Chang
    • Proceedings of the KIEE Conference
    • /
    • 2003.07b
    • /
    • pp.1350-1352
    • /
    • 2003
  • For developing a 100 kW MCFC power generation system, Several design parameters for a fuel cell stack and system analysis results by Cycle Tempo, a processing computer soft ware, were described. Approximately two substacks with 90 cells are required to generate 100 kW at a current density of $125\;mA/cm^2$ with $6000\;cm^2$ of cells. An overall heat balance was calculated to predict exit temperature. The 100 kW power is expected only under pressurized operation condition at 3 atm. Recycle of cathode gas by more than 50% is recommended to run the stack at $125\;mA/cm^2$ and 3 atm. Manifolds should be designed based on gas flow rates for the suggested operating condition. The fuel cell power generation system was designed conceptually with several choices of utilization of anode exhaust gas. To operate and evaluate the MCFC system, control and measurement system and operation mode are designed before 100 MCFC system construction. In system control schematics, OS, PLC and MMI were consisted and have roles for MCFC system control. For operation of 100 kW MCFC system, NS, PS PR mode were considerated step by step and simulated.

  • PDF