• Title/Summary/Keyword: bacterial contamination level

Search Result 90, Processing Time 0.021 seconds

A Study on Hygiene and Safety of Sanitary Wet Towel (물수건의 위생실태 및 안전성 연구)

  • Kim, Young-Sug;Kim, Yang-Hee;Kim, Young-Su;Kim, Dae-Hwan;Ryu, Kyong-Shin;Yoon, Mi-Hye
    • Journal of Food Hygiene and Safety
    • /
    • v.31 no.4
    • /
    • pp.258-263
    • /
    • 2016
  • The risks of sanitary indicative bacteria, heavy metals and chlorinated derivatives in 94 cases of sanitary wet towels used in food services (39 from sanitary wet towel treatment business, 55 from food services) were assessed in the present study. Lead was detected in the range of N.D.~0.41 mg/kg (75 cases were not detected), N.D.~0.25 mg/kg of arsenic (93 cases were not detected), N.D.~0.01 mg/kg of cadmium (7 cases were lower than limit of quantitation; 87 cases were not detected), 0.003 mg/kg ~ 0.09 mg/kg of mercury. And chromium (VI) was not detected from all samples. The level of lead was the highest among the tested heavy metals, and the highest concentration of lead was 0.41 mg/kg. However, it was only 2.1% of legal limit (less than 20 mg/kg). The average moisture content of the samples was 61.9% (50.0% ~ 77.0%) and it showed no relevance to the detection of bacterial counts. Escherichia coli was not detected. Bacterial counts were detected 43 cases and among them, 24 cases were exceeded the legal limit. It was verified that the packaging conditions of sanitary wet towel (whether it is packed by a piece or not and sealed or not) are critical factors to cause the germ contamination and cross contamination in the wet towels. The chlorinated derivatives (chlorites and chlorates) were detected in 17 (19.3%) out of 88 cases. The results would be used as preliminary information to establish the programs of "Safety education for manufacturers and public policy of safety".

Microbial Population, Aflatoxin Contamination and Predominant Aspergillus Species in Korean Stored Rice

  • Oh, Ji-Yeon;Sang, Mee-Kyung;Oh, Jee-Eun;Lee, Ho-Joung;Ryoo, Mun-Il;Kim, Ki-Deok
    • The Plant Pathology Journal
    • /
    • v.26 no.2
    • /
    • pp.121-129
    • /
    • 2010
  • We evaluated microbial populations and aflatoxin production in unhulled and white rice from rice processing complexes of the National Agricultural Cooperative Federation in five regions in Korea and identified three predominant Aspergillus species. Fungal and bacterial populations in rice samples were significantly different between regions in 2007. Aflatoxins were also detected and varied at the levels of 2.45 - 3.43 ng per g unhulled rice grain and 1.29 - 2.09 ng per g white rice grain. Unhulled rice generally detected higher level of aflatoxins than white rice regardless of sampling regions; however, no significant differences were found in Anseong and Cheonan in 2005 and Cheonan and Gimpo in 2007. Aflatoxin production between sampling regions was not different regardless of rice type and sampling year. Although the fungal diversity was highly distinct from region to region, three Aspergillus isolates were predominant in the rice samples; thus, representative isolates AC317, AF57, and AF8 were selected and identified based on their morphological and molecular characteristics. Consequently, isolates AC317, AF57, and AF8 were identified as A. candidus, A. flavus, and A. fumigatus, respectively. These fungi can produce mycotoxins that are harmful for consumers and thus it is important to detect and reduce the population of storage fungi in rice.

The Bacteriological Quality of Seawater in Kamak Bay, Korea (가막만해역 해수의 세균학적 수질 평가)

  • Kwon, Ji Young;Park, Kunbawui;Song, Ki Cheol;Oh, Eun Gyoung;Lee, Hee Jung;Jo, Mi-Ra;Kim, Ji Hoe;Son, Kwang Tae
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.45 no.5
    • /
    • pp.460-464
    • /
    • 2012
  • From 1998 to 2008, the bacteriological quality of seawater in Kamak Bay, Korea, was monitored. The total and fecal coliforms in seawater were monitored as bacterial indicators, and the level of fecal coliform contamination was used to evaluate seawater quality. In the southern shellfish growing area of Kamak Bay, the observed fecal coliform geometric mean (GM) and estimated 90th percentile did not exceed the quality standards for fecal coliforms in seawater in Korea and th USA (GM<14 MPN/100 mL, 90th percentile<43 MPN/100 mL). The GM and estimated 90th percentile of the fecal coliform levels in the adjacent northern area of Kamak Bay were higher than in the southern area. Stations near wastewater discharge sites and urban areas in the north had the lowest quality and did not meet the bacteriological seawater quality criteria. The high fecal coliform levels in the Seonso coastal region near wastewater discharges and northern urban areas declined significantly following dredging and operation of a sewage treatment plant.

Exploring the Feasibility of 16S rRNA Short Amplicon Sequencing-Based Microbiota Analysis for Microbiological Safety Assessment of Raw Oyster

  • Jaeeun Kim;Byoung Sik Kim
    • Journal of Microbiology and Biotechnology
    • /
    • v.33 no.9
    • /
    • pp.1162-1169
    • /
    • 2023
  • 16S rRNA short amplicon sequencing-based microbiota profiling has been thought of and suggested as a feasible method to assess food safety. However, even if a comprehensive microbial information can be obtained by microbiota profiling, it would not be necessarily sufficient for all circumstances. To prove this, the feasibility of the most widely used V3-V4 amplicon sequencing method for food safety assessment was examined here. We designed a pathogen (Vibrio parahaemolyticus) contamination and/or V. parahaemolyticus-specific phage treatment model of raw oysters under improper storage temperature and monitored their microbial structure changes. The samples stored at refrigerator temperature (negative control, NC) and those that were stored at room temperature without any treatment (no treatment, NT) were included as control groups. The profiling results revealed that no statistical difference exists between the NT group and the pathogen spiked- and/or phage treated-groups even when the bacterial composition was compared at the possible lowest-rank taxa, family/genus level. In the beta-diversity analysis, all the samples except the NC group formed one distinct cluster. Notably, the samples with pathogen and/or phage addition did not form each cluster even though the enumerated number of V. parahaemolyticus in those samples were extremely different. These discrepant results indicate that the feasibility of 16S rRNA short amplicon sequencing should not be overgeneralized in microbiological safety assessment of food samples, such as raw oyster.

Clinical Efficacy of Latex Cover for Dental Handpiece (치과 핸드피스용 감염방지구의 임상적 효용성)

  • Lee, Ki-Ho;Paek, Dong-Heon
    • Journal of Oral Medicine and Pain
    • /
    • v.34 no.3
    • /
    • pp.237-245
    • /
    • 2009
  • The purpose of this study was to investigate the clinical efficacy of latex cover developed for dental handpiece on contamination of microorganisms during dental treatment and to determine whether it can be an alternative to conventional sterilization such as autoclaving. E. fecaelis was used as a experimental microorganism instead of oral flora. Experimental bowl with 2 cm of rectangular cavity was fabricated for handpiece operating instead of oral cavity. Latex covers ($Orokeeper^{(R)}$, Orobiotech Co., Korea) and several handpieces were used after sterilization by autoclave. Four experiments were performed to evaluate bacterial contamination related with (1) various parts of dental handpiece, (2) swabbing time with alcohol sponge, (3) postoperative air-water spraying time and (4) consecutive use of latex covers without autoclaving. The results show that face of handpiece uncovered with latex cover was severely contaminated than the covered area and that most bacteria were removed by swabbing face and head area of dental hand-piece and by air-water spraying more than 15 seconds nearly up to the level of sterilization. Conclusively it can be suggested that use of latex cover for handpiece during dental procedure, swabbing with alcohol sponge is air-water spraying for more than 15 seconds after use of dental handpiece should be very useful and practical for prevention of cross infection and should be an alternative method for the sterilization of dental handpiece under some difficult situations not being able to sterilize a handpiece with autoclave.

Microbiological Pollution Investigation of Lowland Spring Water at the Jeju City Waterfront, Jeju Island (제주도 내 제주시 해안가 저지대용천수의 미생물학적 오염도 조사)

  • Kim, Man-Chul;Han, Yong-Jae;Heo, Moon-Soo
    • Journal of Life Science
    • /
    • v.22 no.3
    • /
    • pp.324-331
    • /
    • 2012
  • Bacteriological examination of spring water in Jeju City was conducted. A total of 21 spring water samples were collected from January to April, 2010. During the study period, the range of temperature was 0.6 to $15.4^{\circ}C$, and the results of the analyses showed that hydrogen ion concentrations (pH) for spring water were 0.43 to 7.9. Salinity levels for the samples averaged from 3.0 to 1.64%, and levels of water-dissolved oxygen were 1.85 to 6.06 mg/l. The range of total coliforms in spring water samples at 21 stations located in the designated spring water were <1.8->1,600 MPN/100 ml. Furthermore, the range of geometric means of total coliforms was 9.9-151.6 MPN/100 ml, while the range of fecal coliforms in spring water samples at 21 stations located in the designated spring water area was <1.8->1,600 MPN/100 ml. Finally, the range of geometric mean of fecal coliforms was 3.1-151.6 MPN/100 ml. The level of microbial contamination was examined in 21 samples for indications of bacterial contamination such as heterotrophic bacteria, Escherichia coli O157:H7, Salmonella spp., Vibrio parahaemolyticus, Staphylococcus aureus, and Shigella spp. were frequently detected in the spring water. Salmonella spp., Shigella spp., Vibrio parahaemolyticus, and S. aureus were detected in the range of $0-0.5{\times}10^1$, $0-0.1{\times}10^1$, $0-0.1{\times}10^1$, and $0-0.3{\times}10^1$ CFU/ml, respectively, while E. coli O157:H7 was not detected in the examined spring water samples.

A Study Regarding Measurements of Bacterial Contamination Levels in Radiology Room Equipment (방사선과 촬영실 장비의 세균오염도 측정)

  • Choi, Eun-Jin;Song, Hyeon-Je;Dong, Kyung-Rae;Kim, Chang-Bok;Ryu, Jae-Kwang;Kwak, Jong-Gil
    • Journal of Radiation Industry
    • /
    • v.11 no.1
    • /
    • pp.1-6
    • /
    • 2017
  • Reported some level of bacteria in areas that are well made contact in Radiology imaging room evaluate the importance of cleanliness in the hospital management of equipment to check for the presence of pathogenic bacteria. Gwang-ju and Jeol-la city and medium-sized hospitals in the material with a cotton swab and rub evenly Radiology selection cassette, a handle, Apron of the imaging apparatus having the most contact with patients from July 2016 to August 2016 as a target in place and special studios 6, and saline solution will placed in a test tube containing. The swab sample was diluted 1,000 times, you can see the bacteria and the intestinal bacterial selective medium Trypticase Soy Agar (TSA), Muller-Hinton Agar (MHA), Eosin-Methylene Blue (EMB), ENDO(BD, NJ, USA) then incubated smear to. In the incubator (incubator, SANYO, Japan) was observed after incubation of bacteria and counting the total number of bacteria also Colonies (colony) suspected intestinal bacteria were isolated and cultured on KIA medium (BD, NJ, USA). As a result, it was found that this came Gram positive Coccus A hospital handle the F hospital, from the C Gram positive Coccus cassette and handle the F hospital. The striking yellow coloring Staphylococcus aureus 110 agar (STA 110) in the medium sample, but it is suspected staphylococcal Coccus to the final identification in the laboratory is not a single specimen of the two samples from Gram positive Coccus biochemical identification Identification Kit is an API could not, it was thought to be non-Staphylococcus aureus was cultured on blood agar suggesting that (BAP) blood of dance. Dynamic tests were conducted biochemical API kit of the two samples were identified from Gram positive Coccus bacteria Escherichia coli (E. coli) is F hospital cassette was confirmed Eenterobacter cloaca in A hospital possession. Did not aggregate O-26, O-111, O-157 and the serum test was conducted in the laboratory from the E. coli F cassette hospital.

Seasonal Changes in the Microbial Communities on Lettuce (Lactuca sativa L.) in Chungcheong-do, South Korea

  • Woojung Lee;Min-Hee Kim;Juyeon Park;You Jin Kim;Eiseul Kim;Eun Jeong Heo;Seung Hwan Kim;Gyungcheon Kim;Hakdong Shin;Soon Han Kim;Hae-Yeong Kim
    • Journal of Microbiology and Biotechnology
    • /
    • v.33 no.2
    • /
    • pp.219-227
    • /
    • 2023
  • Lettuce is one of the most consumed vegetables worldwide. However, it has potential risks associated with pathogenic bacterial contamination because it is usually consumed raw. In this study, we investigated the changes in the bacterial community on lettuce (Lactuca sativa L.) in Chungcheong-do, South Korea, and the prevalence of foodborne pathogens on lettuce in different seasons using 16S rRNA gene-based sequencing. Our data revealed that the Shannon diversity index showed the same tendency in term of the number of OTUs, with the index being greatest for summer samples in comparison to other seasons. Moreover, the microbial communities were significantly different between the four seasons. The relative abundance of Actinobacteriota varied according to the season. Family Micrococcaceae was most dominant in all samples except summer, and Rhizobiaceae was predominant in the microbiome of the summer sample. At the genus level, the relative abundance of Bacillus was greatest in spring samples, whereas Pseudomonas was greatest in winter samples. Potential pathogens, such as Staphylococcus and Clostridium, were detected with low relative abundance in all lettuce samples. We also performed metagenome shotgun sequencing analysis on the selected summer and winter samples, which were expected to be contaminated with foodborne pathogens, to support 16S rRNA gene-based sequencing dataset. Moreover, we could detect seasonal biomarkers and microbial association networks of microbiota on lettuce samples. Our results suggest that seasonal characteristics of lettuce microbial communities, which include diverse potential pathogens, can be used as basic data for food safety management to predict and prevent future outbreaks.

Effectiveness Analysis on the Application of Ultraviolet and Plasma Treatment Devices for Water Sterilization (용수 살균을 위한 자외선과 플라즈마 처리장치 적용에 따른 효과분석)

  • Kim, Young Jae;Park, Jeon Oh;Lee, Haeng Lim
    • Journal of Marine Life Science
    • /
    • v.4 no.2
    • /
    • pp.86-90
    • /
    • 2019
  • This study aimed to compare the disinfection efficiencies of the ultraviolet and plasma systems, the two systems designed and commercialized to disinfect water in aquaculture, by putting each in a 100 ℓ water tank and concentrating 1.0 ℓ of treated water to check the changes in the number of bacteria in the samples. Each system was operated for 6 hours to culture the typical seawater bacteria in the Marine agar, Thiosulfate citrate bile salts sucrose agar and Salmonella Shigella agar media, respectively, to check the number of bacteria in the media, and the changes in the number of Edwardsiella piscicida in the treated water were checked after the artificial inoculation of E. piscicida in the disinfected seawater. As a result, the two disinfection systems showed the almost similar levels of bacterial reduction efficiency between 99.5% and 99.9%. However, the result of this study showed that, with 100 ℓ of water treated for the same length of time using the two systems, the plasma system turned out to disinfect bacteria in a shorter period of time than the UV system. However, as the changes in the number of bacteria were checked for a short length of time (6 hours) in this study, it was judged that, considering the actual aquaculture environment in which the quality of water significantly changes with feed residues, excretions and coastal contamination, etc., and a lot of biofilms and organic matter exist, the plasma system would be more efficient than the UV system as the former is capable of continuously maintaining a certain level of efficiency than the latter that is limited in terms of efficiency depending on the level of turbidity and the existence of organic matter.

Analysis of the Reduction Effect of Combined Treatment with UV-C and Organic Acid to Reduce Aspergillus ochraceus and Rhodotorula mucilaginosa Contamination (Aspergillus ochraceus와 Rhodotorula mucilaginosa 저감을 위한 자외선과 유기산 복합처리 효과 분석)

  • Eun-Seon Lee;Jong-Hui Kim;Bu-Min Kim;Mi-Hwa Oh
    • Journal of Food Hygiene and Safety
    • /
    • v.39 no.1
    • /
    • pp.54-60
    • /
    • 2024
  • This study investigated the effectiveness of using pathogens and aqueous acids to reduce the Aspergillus ochraceus and Rhodotorula mucilaginosa contamination in livestock production environments. For this study, 1 mL of each bacterial suspension (107-108 spores/mL) was inoculated on a knife surface, dried at 37℃, and used under each treatment condition. First, to investigate the effect of organic acids, acetic, lactic, and citric acids were used. Subsequently, to select the appropriate concentration, they were prepared at concentrations of 0.5, 1, 2, 3, 4, and 5%, respectively. Accordingly, to further maximize the effect of organic acid treatment, we combined the treatment with ultraviolet light. The two strains showed a significant difference (P<0.05) compared to the initial strain, with a greater than 90% decrease in the concentrations of all organic acids. Consequently, acetic and lactic acids decreased by approximately 5 and 2 log colony forming unit (CFU)/cm2, respectively, when treated with ultraviolet light (360 mJ/cm2); however, citric acid decreased by less than 1 log CFU/cm2. However, when manufactured with 4% acetic acid, a severe malodor was emitted, making it difficult for workers to use it in a production environment. Accordingly, the optimal treatment conditions for organic acid and ultraviolet light for application were selected as follows: immersion in a 4% lactic acid solution for 1 minute and then, sterilization with ultraviolet light at 360 mJ/cm2. Finally, when a pork meat sample was cut with a knife that was finally washed with lactic acid and treated with ultraviolet light, the low level of inoculum transferred from the cleaned knife to the surface of the sample was not detected. In conclusion, using this established method can prevent cross-contamination of the surface of the meat during processing.