• 제목/요약/키워드: backwash water

검색결과 67건 처리시간 0.02초

2단 망간모래여과에 의한 고농도 망간 처리 (Removal of High Concentration Manganese in 2-stage Manganese Sand Filtration)

  • 김충환;윤종섭;임재림;김성수
    • 상하수도학회지
    • /
    • 제21권4호
    • /
    • pp.503-508
    • /
    • 2007
  • Small scale D-water treatment plant(WTP) where has slow sand filtration was using raw water containing high concentration of manganese (> 2mg/l). The raw water was pre-chlorinated for oxidation of manganese and resulted in difficulty for filtration. Thus, sometimes manganese concentration and turbidity were over the water quality standard. Two stage rapid manganese sand filtration pilot plant which can treat $200m^3/d$ was operated to solve manganese problem in D-WTP. The removal rate of manganese and turbidity were about 38% and 84%, respectively without pH control of raw water. However, when pH of raw water was controlled to average 7.9 with NaOH solution, the removal rate of manganese and turbidity increased to 95.0% and 95.5%, respectively and the water quality of filtrate satisfied the water quality standard. Manganese content in sand was over 0.3mg/g which is Japan Water Association Guideline. The content in upper filter was 5~10 times more than that of middle and lower during an early operation but the content in middle and lower filter was increased more and more with increase of operation time. This result means that the oxidized manganese was adsorbed well in sand. Rapid manganese sand filter was backwashed periodically. The water quality of backwash wastewater was improved by sedimentation. Thus, turbidity and manganese concentration decreased from 29.4NTU to 3.09NTU and from 1.7mg/L to 0.26mg/L, respectively for one day. In Jar test of backwash wastewater with PAC(Poly-aluminum chloride), optimum dosage was 30mg/L. Because the turbidity of filtrate was high as 0.76NTU for early 5 minute after backwash, filter-to-waste should be used after backwash to prevent poor quality water.

정수처리 응집·한외여과 시스템의 연속운전을 통한 운전조건 결정 및 막오염 특성에 관한 연구 (Determination of operating factor and characteristics of membrane fouling on hybrid coagulation pretreatment-UF system in drinking water treatment)

  • 문성용;윤종섭;김승현
    • 상하수도학회지
    • /
    • 제22권2호
    • /
    • pp.267-274
    • /
    • 2008
  • This study is about efficiency of pretreatment process and operating factor to membrane process at continuous coagulation/ultrafiltration process in water treatment. The capacity of pilot plant was $0.06{\beta}(C)/d$. The raw water used was from Nakdong stream which was characteristized by high organic matter and high turbidity. The result of the test was that coagulation is good process as to high removal rate to organic matter and turbidity but It caused problem to membrane pore blocking. This paper is to determine the membrane fouling potential under different membrane flux, backwash pressure and linear velocity. Backwash pressure and flux is important parameter on operation of membrane system. Those are directly affected on membrane system. When backwash pressure increased from 150 kPa to 200 kPa, the result showed that fouling (pressure increase rate) changed from 3.69 kPa/h to 0.93 kPa/h and the recovery rate changed from 90.7 % to 82.0 %. Linear velocity had slightly effect on fouling. Linear velocity increased from 0.2 m/s to 0.5 m/s, the corresponding pressure rate changed from 0.93 kPa/d to 0.77 kPa/d.

회분식 막여과 시스템에서 약품역세가 여과성능에 미치는 영향 (The Effect of Chemical Backwash on Filtration Performance of Batch Membrane Filtration System)

  • 김관엽;이의종;권진섭;김형수
    • 상하수도학회지
    • /
    • 제23권6호
    • /
    • pp.855-864
    • /
    • 2009
  • The main object of this work was to determine the influence of periodic chemical backwash on filtration resistance in membrane filtration system. In this work Hermia's models were used to investigate the fouling mechanisms involved in the microfiltration of $0.45{\mu}m$ filtered sewage feed. Batch microfiltration experiments were performed at transmembrane pressure 0.4 bar and different feed SCOD concentration (9~67 mgSCOD/L). The results showed that the best fit to experimental data corresponded to the intermediate blocking model followed by the standard and complete blocking model for all the experimental conditions tested. From the simulation results of filtration performance, it was found that in order to maintain sustainable operation of membrane filtration system, irreversible foulant component accumulated continuously on membrane surface and/or pore must be effectively removed. In addition, it was verified that periodic chemical backwash using NaOCl or NaOH effectively improved filtration performance of membrane.

A column study of effect of filter media on the performance of sand filter

  • Kim, Tae-hoon;Oh, Heekyong;Eom, Jungyeol;Park, ChulHwi
    • Membrane and Water Treatment
    • /
    • 제11권4호
    • /
    • pp.247-255
    • /
    • 2020
  • Sand filter is a key unit process for particle removal in water purification treatments. Its long-standing use is due to on-site customized retrofit. Proper selection of filter media is one of the retrofit approaches to improve filter performance. This study described a series of controlled laboratory column tests and examined the effects of media property on filtration and backwash. When sand media of 0.51 mm in effective size was replaced by sand of 0.60 mm, the filter run increased up to 5 times in the given bed depth. The change of media property required an increase of backwash rate by 0.05 m/min to satisfy the requirement of bed expansion, more than 20%. When the anthracite was changed with lower effective size and uniformity coefficient, correlation with sand in the filter bed could be satisfied within the permissible error between media and bulk characteristics. Besides, this selection resulted in a well-stratified configuration of media layers after bed expansion. The column study showed that the correlation of property between the dual media had a significant effect on the filter productivity and backwash interval.

전처리 MF의 다양한 역세 공정을 적용한 하수재이용 파일럿 플랜트 연구 (Study of MF membrane as pretreatment option using various backwash process from wastewater reuse pilot plant)

  • 박광덕;박찬수;이창규;김종오;최준석
    • 상하수도학회지
    • /
    • 제30권3호
    • /
    • pp.335-341
    • /
    • 2016
  • Various studies have forwarded an outstanding wastewater effluent treatment systems toward securing sustainable supply of water sources. In this paper, a broad overview of the performance of MF membrane as pretreatment option for wastewater reuse will be presented based on the literature survey and experiments conducted over the wastewater reuse pilot plant. The pilot plant was operated with a continuous data acquisition for about 300days under various chemical enhanced backwash (CEB) system with subsequent treated water quality analysis. Accordingly, assessment of the effluent revealed that the pretreated water is suitable enough to be used as an input for Reverse Osmosis (RO) unit and significant effect of CEB and concentration of NaOCl is also conceived from the analysis. Moreover, it's also observed that the application of various CEB condition over long operational hours induced a constant declination of overall performance of MF membrane.

막여과 정수장 배출수처리시설의 효율적인 운영방안 (Strategy for efficient operation on the backwash waste treatment in membrane filtration water treatment plant)

  • 정원채;유영범;이선주;문용택
    • 상하수도학회지
    • /
    • 제28권4호
    • /
    • pp.479-489
    • /
    • 2014
  • Membrane backwashing waste shows seasonally different characteristics and it has bad settleability differently from general backwashing waste in water treatment plant. When chemicals was injected to membrane backwashing waste, the settleability was better than chemicals was not injected. However, when settled lower sludge was not discharged, flowing sludge continuously was concentrated over a certain surface and floatation penomena occurred according to flowing velocity. When the lower sludge was discharged continuously in the thickener to prevent floatation penomena of turbidity materials, the depth of sludge surface was the least and the settleability increased.

Membrane Filtration Technology for Drinking Water Treatment & Night Soil Treatment

  • Kato, Yasuhiko
    • 한국막학회:학술대회논문집
    • /
    • 한국막학회 1998년도 제6회 하계 Workshop (98 한국막학회, 국립환경연구원 국제 Workshop, 수자원 보전과 막분리 공정)
    • /
    • pp.155-170
    • /
    • 1998
  • 1. The flux for hydrophilic CA membrane is higher than that for hydrophobic PES membrane at any operating conditions. The difference in bpth fluxes becomes greater as the water recovery is lower. 2. Backwash pressure should be more than twice as high as filtration pressure in order to maintain the higher flux. Backwash frequency is independent of the flux when the UF is operated under the same water recovery. 3. The relatively lower crossflow velocity of around 0.1 m/s would be appropriate because of the lower energy consumption per treated water. 4. The membrane fouling occurring at high turbidity and high concentration of organic compounds in raw water can reduce the flux and increase the removal of the organic compounds. 5. It is confirmed by the pilot plant testing that the UF by using the CA membrane module was well applicable to the drinking water treatment.

  • PDF

UF를 이용한 용존성 유기물질 제거시 운전조건이 파울링에 미치는 영향 (Effect of Operating Conditions on the Fouling of UF Membrane in Treatment of Dissolved Organic Matter)

  • 권은미;유명진
    • 대한환경공학회지
    • /
    • 제22권7호
    • /
    • pp.1183-1191
    • /
    • 2000
  • UF를 이용한 용존성 유기물질 제거시 파울링을 저감할 수 있는 운전인자를 알아보기 위하여 pilot plant 규모의 중공사형 UF막을 다양한 실험조건에서 운전하였다. 연구결과 유입압력이 높으면 막표면에 생성된 케익의 압밀화화 흡착이 증대되어 막간차압의 증가폭과 투과플럭스 감소폭이 커졌다. 역세효과는 역세압을 높여서 유효압을 증가시키거나 역세빈도를 짧게 할수록 좋았다. 유효압이 증가할수록 역세후 막표면의 오염물질이 감소하고 역세빈도가 짧을수록 재순환수의 오염물질농도가 감소하기 때문이다. 파울링과 상관성이 높은 운전인자는 역세압, 유입압력, 회수율, 누적투과플럭스, 투과플럭스였다. 이 중 역세압력이 파울링과 가장 밀접한 관계가 있었고 유입압력이 두 번째로 상관성이 높았다. 이것으로 보아 막표면의 케익층 압밀화와 흡착의 원인이 되는 압력이 파울링과 밀접한 관계가 있는 것으로 생각된다.

  • PDF

역세척 Hydrodynamic Separator Filter를 이용한 미세입자 제거 특성 분석 (Performance Evaluation of Backwash Hydrodynamic Separator Filter for Treatment of Micro Particles)

  • 이준호;방기웅
    • 대한환경공학회지
    • /
    • 제34권10호
    • /
    • pp.694-701
    • /
    • 2012
  • 본 연구는 여재를 장착한 수리동역학적 여과분리장치(HSF)와 태양전지 구동형 수중펌프를 조합한 장치의 여재 역세척 가능성에 대하여 분석하였다. 수중펌프는 12볼트 직류모터로 구동되며 태양전지와 축전지로 가동된다. 수리동력학적 분리장치와 펄라이트 여재를 충진한 카트리지에 역세척용 노즐을 장착하였다. 입자물질들은 인공입자들을 이용하여 강우유출수내 입자농도를 모의 실험하였다. 인공입자들을 물에 분산시켜 강우유출수를 재현하였는데 사용한 입자들은 이온교환수지 입자, 실리카젤 입자, 그리고 상업지역 맨홀퇴적물질 입자 등이다. HSF장치는 아크릴 수지를 이용하였는데 여과조의 직경은 250 mm이고 전체적인 높이는 800 mm로 제작하였다. 유입수 SS 농도와 입경, 다양한 수면적 변화를 변화에 대한 역세척 방법별 SS 처리효율을 산정하였다. 전체적인 수면적부하율 범위는 308~$1,250m^3/m^2/day$이다. 태양전지를 이용한 최소한의 전력으로 구동되는 펌프를 이용하여 역세척을 실시한 결과 2대의 수중 펌프를 가동하여 역세척 시 역세척하지 않은 여재와 비교하여 약 18% 처리효율 증가효과를 나타내었다. 비점오염 처리장치에 소규모 태양전지를 활용하여 여재를 역세척할 경우 처리효율을 향상시킬 수 있을 것으로 판단된다.

응집 및 정밀여과공정의 강화역세정시 NaOCl에 따른 PTFE막 투과능 회복과 막오염층 변화 (Permeability recovery and changes in fouling layer characteristics of PTFE membrane by enhanced backwash cleaning using NaOCl during coagulation and microfiltration)

  • 강선구;박근영;곽동근;김윤중;권지향
    • 상하수도학회지
    • /
    • 제29권2호
    • /
    • pp.233-241
    • /
    • 2015
  • Polytetrafluoroethylene (PTFE) membrane has high resistance to chlorine, which is a great advantages in chemical cleaning to recover water flux during membrane processes in drinking water systems. A humic kaolin water with approximately 4 mg/L of DOC and 10 NTU of turbidity was prepared as a feed water. Coagulation pretreatment with or without settling was applied. The coagulation with settling showed the greatest water production. The reduced flux was effectively recovered by NaOCl cleaning, i.e., 21% recovery by 50 mg/L of NaOCl cleaning and 49% recovery by 500 mg/L NaOCl cleaning. The images of SEM and AFM analyses were corresponded to the water flux variation. However, when the floc was accumulated on the membrane surfaces, the efficiency of NaOCl cleaning was substantially limited. In addition, dynamic contact angle became greater after cleaning, which indicates changes in characteristics of fouling layer such as surface hydrophobicity. Proper cleaning technologies during enhanced backwash using NaOCl would expand application of PTFE membranes in drinking water systems.