• Title/Summary/Keyword: backward

Search Result 2,439, Processing Time 0.028 seconds

Network Effects and Dynamic Capabilities (네트워크 효과와 동태적 경쟁역량)

  • Lee, Jong-Seok
    • Korean Business Review
    • /
    • v.19 no.2
    • /
    • pp.183-206
    • /
    • 2006
  • Recently, the notion of "increasing returns" has been popular not only in academia but also in industries. This notion has been drawn from prior research on network effects, which showed that the market evolution would lock in to a dominant technology. However, the long history of technological change has rarely shown the possibility of lock-in to an inferior technology. How could the market with network effects make transition between incompatible technologies regimes by escaping the lock-in? This paper analyzes the effectiveness of R&D and technological choice to investigate the sources of the dynamic capabilities in the presence of network effects and uncertain technological progress. Why does the market sometimes work against a radical technology, and why, at other times, does the market operate in favor of it? This study is to address this question by modeling the situation of two competing technologies in the presence of network effects. The numerical analysis indicates that the evolution strategy of compatibility is more likely to increase the chance of firm growth when a majority of customers are not power users or when demand for an old technology has been escalated. But when there are a substantial number of power users or when a new technology emerges before such an escalation of demand, the revolution strategy of compelling performance is more likely to be effective. The result suggests a potential mechanism for overcoming the lock-in problem. When the market exhibits some inertia to an obsolete technology, which is reinforced by the increasing customer value with respect to backward compatibility, the survival of a new technology depends on power users. When many power users are cultivated by firms' technological efforts regarding the new technology, the market is less likely to lock into an obsolete technology. Indeed, in the workstation market, where power users characterize much of the demand, innovators like Sun successfully switched to the RISC architecture.

  • PDF

Anterior Talofibular Ligament and Superior Extensor Ankle Retinaculum Thicknesses: Relationship with Balance

  • Malloy, Brooke;Furrow, David;Cook, Haily;Smoot, Elizabeth;Cash, Lindsey;Aron, Adrian;Jagger, Kristen;Harper, Brent
    • Journal of Korean Foot and Ankle Society
    • /
    • v.23 no.4
    • /
    • pp.173-182
    • /
    • 2019
  • Purpose: This study determined if anterior talofibular ligament (ATFL)/superior extensor ankle retinaculum (SEAR) thicknesses are related to dynamic balance in individuals with chronic ankle instability (CAI). Materials and Methods: The subjects were 14 males and 15 females (age=24.52±3.46 years). Ankle instability was assessed using the Cumberland Ankle Instability Tool (CAIT) with a cut off score of 25 to define two groups. SonoSite MTurbo (Fugifilm Sonosite, Inc.) musculoskeletal ultrasound (MSKUS) unit was used to assess ATFL and SEAR thicknesses. Dynamic balance was measured with the Y Balance Test (YBT) and two NeuroCom balance tests. Results: There were no significant differences in the average ATFL thickness between stable and unstable ankles in those subjects with CAI (0.25±0.03 cm and 0.21±0.05 cm, respectively) or in the SEAR thickness (0.09±0.04 cm and 0.10±0.03 cm, respectively). There were also no significant differences in the right and left ATFL thicknesses (0.23±0.07 cm and 0.21±0.04 cm, respectively) or the SEAR thicknesses (0.09±0.01 cm and 0.09±0.01 cm, respectively) in those without CAI. There were no differences between limbs in composite scores on YBT in those with CAI (p=0.35) and those without CAI (p=0.33). There was a moderate correlation between the left SEAR thickness and the large forward/backward perturbations on the NeuroCom (Natus) motor control test (r=0.51, p=0.006 and r=0.54, p=0.003, respectively). Conclusion: There were no differences in the ATFL/SEAR thicknesses or balance measures between or within the groups, likely because CAI is multi-factorial and related to mechanisms other than tissue changes alone. More sensitive technology and a better definition of the measurement process may provide more definitive results.

Third-Party Financing Contracts Between Energy Users and Energy Saving Companies (비대칭정보하에서의 최적계약 도출 -에너지절약시장)

  • Kang, Kwang-Kyu
    • Journal of Environmental Policy
    • /
    • v.8 no.4
    • /
    • pp.75-94
    • /
    • 2009
  • The process of obtaining third-party financing contacts was analyzed via a two-stage game model: a "signaling game" for the first stage,and a "principal-agent model" for the second stage. The two-stage game was solved by a process of backward induction. In the second stage game, the optimal effort level of the energy saving company (ESCO), the optimal compensation scheme of the energy user, and the optimal payoffs for both parties were derived for each subgame. The optimal solutions forthe different subgames were then compared with each other. Our main finding was that if there is some restriction on ESCO's revenue (e.g. a progressive sales tax) that causes ESCO's revenue toincrease at a decreasing rate, then the optimal sharing ratio is uniquely determined at a level of strictly less than one under a linear compensation scheme, i.e. a unique balance exists. Subgames have a unique equilibrium arrived at separately for each situation,. Within this equilibrium, energy users accept energy audit proposals from H-type ESCOs with high levels of technology, but reject proposals from L-type ESCOs with low levels of technology. While L-type ESCOs cannot attain profits in the third-party financing market, H-type ESCOS can pocket the price differential between L-type and H-type audit fees. Accordingly, revenues in an H-type ESCO equilibrium increase not only in line with the technology of the ESCO inquestion, but also faster than in an L-type equilibrium due to more advanced technology. At the same time, energy users receive some positive payoff by allowing ESCOs to perform third-party financing tasks within their existing energy system without incurring any extra costs.

  • PDF

A study on treatment effects of Class III cases by second molar extraction (제 2 대구치 발거에 의한 III급 부정교합자의 치료효과에 관한 연구)

  • Lee, Sung-Hee;Park, Young-Guk;Chung, Kyu-Rhim
    • The korean journal of orthodontics
    • /
    • v.34 no.2 s.103
    • /
    • pp.109-119
    • /
    • 2004
  • This study aimed at investigating the skeletal, dentoalveolar, and soft tissue changes of Class III malocclusion cases treated by second molar extraction. The lateral cephalograms of 15 subjects with moderate Class III malocclusion by average ANB $-1.4^{\circ}\;and\;IMPA\;85^{\circ}$ were traced and the computerized superimposition of average craniofacial change was made. The data was gathered and statistically analyzed. The results were as follows: 1 Lower anterior facial height/anterior facial height increased by 0.6%(P<0.01), mandibular plane increased by $1.5^{\circ}$(P<0.05). 2. There was a slightly downward & backward rotation of the mandible. 3. Lower first molar tipped distally by 4.nm(P<0.001), lower anterior teeth lingually tipped by $3.2^{\circ}$(P<0.05). 4. Retracted lower lip improved facial profile. This study may suggest that second molar extraction could be effective for a moderate Class III malocclusion to make distalization of the lower first molar easier and avoid severe lingual tipping of the lower incisor, if the lower third molar has a normal shape, good direction of eruption and adequate time for lower second molar extraction

Effects of Facemask Therapy for Class III Malocclusions in Patients with Different Vertical Skeletal Patterns (3급 부정교합 환자의 수직적 골격 양상에 따른 facemask 치료 효과 비교)

  • Lee, Eunha;Park, Kitae
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.42 no.2
    • /
    • pp.126-135
    • /
    • 2015
  • The purpose of this study was to evaluate the skeletal and dentoalveolar effects of facemask therapy and to compare the anchorage of a bonded expander in patients with Class III malocclusion and different vertical skeletal patterns. Twenty subjects with Class III malocclusion were included in this study and were treated with a facemask and bonded expander. Based on the FMA, subjects were divided into two groups of 10 patients each: a high vertical group (HV; mean FMA $33.56^{\circ}$) and an average vertical group (AV; mean FMA $24.88^{\circ}$). Lateral cephalograms were taken and evaluated before and after treatment. In both groups, forward movement of the maxilla and backward rotation of the mandible were observed after treatment, with no statistical differences between the groups. Vertical skeletal variables increased in both groups, but the increase of FMA was significantly larger in the HV group than the AV group. Mesial movement of maxillary molars and proclination of maxillary incisors which indicate anchorage loss of bonded expander were observed in both groups, with no significant differences between the groups. In conclusion, facemask therapy resulted in effective maxillary protraction in both HV and AV groups. However, the open bite tendency was increased more in the HV group.

A Study on the Estimation of Stability of Fill Dam by Long-term Electrical Resistivity Monitoring (장주기 전기비저항 모니터링 기법을 이용한 필댐의 안정성 평가)

  • Kim, Gi-Ho;Lim, Heui-Dae;Ahn, Hee-Yoon
    • Journal of the Korean Geotechnical Society
    • /
    • v.29 no.5
    • /
    • pp.53-64
    • /
    • 2013
  • Resistivity monitoring is based on the fact that a change in the porosity leads to the changes in water content and fine particles, which alter the electrical resistivity. At every embankment dam, internal erosion always occurs as time passes. The internal erosion generally develops into piping over a long time by backward erosion and concentrated leak, and finally leads to dam failure. Resistivity is known to be very sensitive to the changes in porosity in embankment dams. Thus resistivity monitoring is a reasonable method to find out the leakage zone. However, resistivity is strongly influenced by seasonal variation of temperature, TDS of reservoir water and water level. In this paper. we first installed electrodes permanently at the center of the crest. The electrical resistivity monitoring data was acquired every 6 hours from Apr. 3, 2011 to July. 31, 2012. To analyze the characteristics of monitoring data, each resistivity data was calculated from up to 2,950 data sets. The result indicated a seasonal resistivity variation due to related temperature. Finally, a quantitative method to estimate porosities of the embankment dam from the resistivity monitoring data was analyzed. The applicability and reliability were verified and the importance of electrical resistivity monitoring for obtaining reliable result was emphasized.

A Study of the Factors Affecting the Backward Transfer of BSA from AOT Reverse Micellar Solutions (AOT 역미셀 용액으로부터 BSA의 역추출에 영향을 미치는 인자들에 관한 연구)

  • 노선균;강춘형
    • KSBB Journal
    • /
    • v.15 no.6
    • /
    • pp.649-657
    • /
    • 2000
  • The factors affecting the back-extraction efficiency of Bovine Serum Albumin (BSA, Mw. 65kDa, pl 4.9) solubilized in an AOT reverse micellar solution, prepared by the injection method, to an excess aqueous phase were investigated. In particular, the effects of pH, the types of salts, alcohols added as cosurfactants, and their concentrations in the aqueous phase were examined. Furthermore, by comparing the CD spectra of the back-extracted BSA and the feed BSA, the structural changes of BSA during the extraction process were determined. The addition of 1:1 salt such as KCl or NaCl to the aqueous phase resulted in almost a 100% extraction to the aqueous phase at a pH higher than its isoelectric point pl. This high efficiency of back-extraction might be due to the change in the interactions between the protein and micellar aggregates driven by the added salt. For 1:2 salts like $CaCl_2$ and $MgCl_2$, BSA was back-extracted with lower than 20% extraction efficiency. Maximum extraction efficiencies were attained at about pH=7 and pH=8 for monovalent and divalent salts, respectively. The addition of alcohols as cosurfactants led to an improvement in monovalent and divalent salts, respectively. From the CD spectra of BSA extracted to the aqueous phase, it was observed that denaturation of BSA was not significant. In certain back-extraction conditions, the extracted BSA showed even higher activity than the feed BSA.

  • PDF

A Study on the Systematic Integration of WASP5 Water Quality Model with a GIS (GIS와 WASP5 수질모델의 유기적 통합에 관한 연구)

  • 최성규;김계현
    • Spatial Information Research
    • /
    • v.9 no.2
    • /
    • pp.291-307
    • /
    • 2001
  • In today's environmental engineering practice, many technologies such as GIS have been adopted to analyze chemical and biological process in water bodies and pollutants movements on the land surface. However, the linkage between spatially represented land surface pollutants and the in-stream processes has been relatively weak. This lack of continuity needs to develop a method in order to link the spatially-based pollutant source characterization with the water quality modeling. The objective of this thesis was to develop a two-way(forward and backward) link between ArcView GIS software and the USEPA water quality model, WASP5. This thesis includes a literature review, the determination of the point source and non-point source loadings from WASP5 modeling, and the linkage of a GIS with WASP5 model. The GIS and model linkage includes pre-processing of the input data within a GIS to provide necessary information for running a model in the forms of external input files. The model results has been post-processed and stored in the GIS database to be reviewed in a user defined form such as a chart, or a table. The interface developed from this study would provide efficient environment to support the easier decision making form water quality management.

  • PDF

Optimal Mechanism Design of In-pipe Cleaning Robot (관로 청소 로봇의 최적 설계)

  • Jung, C.D.;Chung, W.J.;Ahn, J.S.;Shin, G.S.;Kwon, S.J.
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.21 no.1
    • /
    • pp.123-129
    • /
    • 2012
  • Recently, interests on cleaning robots workable in pipes (termed as in-pipe cleaning robot) are increasing because Garbage Automatic Collection Facilities (i.e, GACF) are widely being installed in Seoul metropolitan area of Korea. So far research on in-pipe robot has been focused on inspection rather than cleaning. In GACF, when garbage is moving, the impurities which are stuck to the inner face of the pipe are removed (diameter: 300 mm or 400 mm). Thus, in this paper, by using TRIZ (Inventive Theory of Problem Solving in Russian abbreviation), an in-pipe cleaning robot of GACF with the 6-link sliding mechanism will be proposed, which can be adjusted to fit into the inner face of pipe using pneumatic pressure(not spring). The proposed in-pipe cleaning robot for GACF can have forward/backward movement itself as well as rotation of brush in cleaning. The robot body should have the limited size suitable for the smaller pipe with diameter of 300 mm. In addition, for the pipe with diameter of 400 mm, the links of robot should stretch to fit into the diameter of the pipe by using the sliding mechanism. Based on the conceptual design using TRIZ, we will set up the initial design of the robot in collaboration with a field engineer of Robot Valley, Inc. in Korea. For the optimal design of in-pipe cleaning robot, the maximum impulsive force of collision between the robot and the inner face of pipe is simulated by using RecurDyn(R) when the link of sliding mechanism is stretched to fit into the 400 mm diameter of the pipe. The stresses exerted on the 6 links of sliding mechanism by the maximum impulsive force will be simulated by using ANSYS$^{(R)}$ Workbench based on the Design Of Experiment(in short DOE). Finally the optimal dimensions including thicknesses of 4 links will be decided in order to have the best safety factor as 2 in this paper as well as having the minimum mass of 4 links. It will be verified that the optimal design of 4 links has the best safety factor close to 2 as well as having the minimum mass of 4 links, compared with the initial design performed by the expert of Robot Valley, Inc. In addition, the prototype of in-pipe cleaning robot will be stated with further research.

Characteristic Analysis of Flexibility and Muscle Strength according to Exercise using Lumbar Strengthen Exercise Instrument (요추강화 운동기기의 훈련을 통한 유연성 및 근력 특성 분석)

  • Kang, S.R.;Kim, K.;Jeong, G.Y.;Moon, D.A.;Kwon, T.K.
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.4 no.1
    • /
    • pp.53-61
    • /
    • 2010
  • In this paper, We investigated the characteristic analysis of flexibility and muscle strength for exercise to verify capacity in rehabilitation exercise of lumbar using lumbar strengthen exercise instrument. We have experiment in 20th years man and woman who are 20 subject with no medical history, we divided subjects into control group with no exercise and training group with lumbar strengthen exercise. We used Hi-Spine(Medicalscience.korea) also, provided exercise 40 minute a day, three days a week and progressed total four weeks. Moreover in our experiment, subjects exercised four postural position as lay down, sit, stand and stretch each ten minute. We measured trunk extension backward, trunk flexion forward, evaluation of based physical fitness and lumbar joint torque. The reults have shown that there more improved all for flexibility, based physical fitness and lumbar joint torque in training group than control group. We indicated that by rotating 3-D axis movement flatform of exercise instrument, muscle spindle in subject have been stimulated and these rotation direction and angle caused muscle tonus and contraction that makes muscle, flexibility and based physical fitness improve more. Our study can be used rehabilitation exercise program to aged people and patient with lumbar injury.