• 제목/요약/키워드: background noise

검색결과 965건 처리시간 0.025초

Assessment of the Risks of Occupational Diseases of the Passenger Bus Drivers

  • Golinko, Vasyl;Cheberyachko, Serhiy;Deryugin, Oleg;Tretyak, Olena;Dusmatova, Olga
    • Safety and Health at Work
    • /
    • 제11권4호
    • /
    • pp.543-549
    • /
    • 2020
  • Background: The working conditions of bus drivers are difficult; they lead to occupational diseases and require careful study, particularly in Ukraine. The objective of the article is the description of occupational health risks of passenger bus drivers that lead to deteriorating health. Methods: The risk assessment was performed using a modified Risk Score method, which allowed determining the generalized level of danger to the driver's health. The hygienic hazards level was assessed as based on Stevenson's law, which was generalized later. Results: Based on the modification of the Risk Score method, it was possible to depart from expert assessments method of the risk level and calculate the general indicator based on the degree of dependence of the impact on the human body on its intensity, proposed by V. Minko. This allows objective determining of the impact of hygiene hazards on the health of the driver and to predict the occurrence of occupational diseases associated with the cardiovascular system, musculoskeletal system, and partial or complete disability due to the accumulation of emotional fatigue. The hazard assessment was carried out for three brands of passenger buses common in Ukraine, in which the driver is exposed to the dangers of fever, vibration, noise, harmful impurities in the bus cabin, and emotional load. Conclusion: The health of drivers in the cabins of passenger buses is most affected by hygiene hazards: fever, vibration, and emotional stress. The generalized level of risk is calculated by the modified method of Risk Score is 0.83; -0.99, -0.92 respectively.

Effect of Speech Degradation and Listening Effort in Reverberating and Noisy Environments Given N400 Responses

  • Kyong, Jeong-Sug;Kwak, Chanbeom;Han, Woojae;Suh, Myung-Whan;Kim, Jinsook
    • Journal of Audiology & Otology
    • /
    • 제24권3호
    • /
    • pp.119-126
    • /
    • 2020
  • Background and Objectives: In distracting listening conditions, individuals need to pay extra attention to selectively listen to the target sounds. To investigate the amount of listening effort required in reverberating and noisy backgrounds, a semantic mismatch was examined. Subjects and Methods: Electroencephalography was performed in 18 voluntary healthy participants using a 64-channel system to obtain N400 latencies. They were asked to listen to sounds and see letters in 2 reverberated×2 noisy paradigms (i.e., Q-0 ms, Q-2000 ms, 3 dB-0 ms, and 3 dB-2000 ms). With auditory-visual pairings, the participants were required to answer whether the auditory primes and letter targets did or did not match. Results: Q-0 ms revealed the shortest N400 latency, whereas the latency was significantly increased at 3 dB-2000 ms. Further, Q-2000 ms showed approximately a 47 ms delayed latency compared to 3 dB-0 ms. Interestingly, the presence of reverberation significantly increased N400 latencies. Under the distracting conditions, both noise and reverberation involved stronger frontal activation. Conclusions: The current distracting listening conditions could interrupt the semantic mismatch processing in the brain. The presence of reverberation, specifically a 2000 ms delay, necessitates additional mental effort, as evidenced in the delayed N400 latency and the involvement of the frontal sources in this study.

단일 나노입자의 다중 물리량의 평가를 위한 입자 모션 트랙킹 알고리즘 (Particle-motion-tracking Algorithm for the Evaluation of the Multi-physical Properties of Single Nanoparticles)

  • 박예은;강지윤;박민수;노효웅;박홍식
    • 센서학회지
    • /
    • 제31권3호
    • /
    • pp.175-179
    • /
    • 2022
  • The physical properties of biomaterials are important for their isolation and separation from body fluids. In particular, the precise evaluation of the multi-physical properties of single biomolecules is essential in that the correlation between physical and biological properties of specific biomolecule. However, the majority of scientific equipment, can only determine specific-physical properties of single nanoparticles, making the evaluation of the multi-physical properties difficult. The improvement of analytical techniques for the evaluation of multi-physical properties is therefore required in various research fields. In this study, we developed a motion-tracking algorithm to evaluate the multi-physical properties of single-nanoparticles by analyzing their behavior. We observed the Brownian motion and electric-field-induced drift of fluorescent nanoparticles injected in a microfluidic chip with two electrodes using confocal microscopy. The proposed algorithm is able to determine the size of the nanoparticles by i) removing the background noise from images, ii) tracking the motion of nanoparticles using the circular-Hough transform, iii) extracting the mean squared displacement (MSD) of the tracked nanoparticles, and iv) applying the MSD to the Stokes-Einstein equation. We compared the evaluated size of the nanoparticles with the size measured by SEM. We also determined the zeta-potential and surface-charge density of the nanoparticles using the extracted electrophoretic velocity and the Helmholtz-Smoluchowski equation. The proposed motion-tracking algorithm could be employed in various fields related to biomaterial analysis, such as exosome analysis.

Trend Analysis by Risk Observation: How the German Statutory Accident Insurance Prepares for the Future in Occupational Safety and Health

  • Angelika Hauke;Eva Flaspoler;Ruth Kluser;Ina Neitzner;Dietmar Reinert
    • Safety and Health at Work
    • /
    • 제13권4호
    • /
    • pp.429-439
    • /
    • 2022
  • Background: The risk observatory (RO) of the German Social Accident Insurance (DGUV) provides strategic support to the German Social Accident Insurance Institutions (GSAII) in proactive prevention. It does so by identifying future challenges and opportunities for occupational safety and health (OSH) resulting from new trends and developments that affect employees as well as children in elementary education, pupils, and students. Methods: The core of the RO is an online survey that relies on a pool of new trends and developments identified via internet and literature research. 865 prevention experts of the GSAII and the DGUV participated in the survey. They rated trends and developments regarding their sector-specific risks and opportunities for OSH in the 5 years to come. Results: Sector-specific and over-all results show that besides well-known OSH risks such as musculoskeletal stress and noise, developments relevant for OSH come to the fore that do not have their origin in work itself, but are strongly influenced by political, social, economic, environmental, or technical developments that accident insurance can only peripherally influence. Shortage of skilled staff was identified as a threat to OSH in almost all sectors. Conclusions: Prevention must find ways to address repercussions of such OSH risks. Cooperation and political awareness are therefore gaining in importance. Also, implementing a prevention culture in society and strengthening individuals' health and safety literacy, e.g., by target-group-specific communication and sensitization, as well as early safety and health education, help to counteract those OSH risks.

Evaluation of Pain Reduction and Clinical Efficacy of Feedback-Controlled Ultrasonic Scaler

  • Min-ju Kim;Hee-jung Lim;Myoung-hee Kim;Young-sun Hwang;Im-hee Jung
    • 치위생과학회지
    • /
    • 제23권2호
    • /
    • pp.176-184
    • /
    • 2023
  • Background: Recently, a piezoelectric ultrasonic scaler based on a feedback control mechanism was introduced for pain relief. This study aimed to investigate the effects of a new ultrasonic scaler in reducing pain and discomfort in adults. Methods: A newly introduced ultrasonic scaler (Master 700®) was used as the test device and a conventional ultrasonic scaler device (PIEZON®) was used as the control device. Forty-one healthy adults visited the dental clinic for dental scaling but did not undergo scaling or periodontal treatment within 6 months. Intraoral examinations were performed before scaling and 3 months later; before scaling, both devices were randomly assigned on the left or right side of each dentition (split-mouth model) and scaling was performed by a registered dental hygienist. The levels of pain and discomfort during scaling were evaluated subjectively and objectively using the visual analog scale (VAS) and physiological monitoring of the heart rate (HR), respectively. Time was measured for each device. Results: All clinical indicators, except bleeding on probing, significantly improved with both devices. The treatment times were 7 minutes, 13 minutes (control) and 6 minutes, 59 minutes (test). VAS scores for pain were 4.89±2.12 (control) and 4.58±2.77 (test) points out of 10; for noise, these were 4.68±2.33 (control) and 4.55±2.55 (test), and for vibration, the values were 4.26±2.0 (control) and 4.18±2.48 (test). HR averages were 72.34±3.39 (control) and 75.97±9.78 (test) beats/min. No statistically significant differences were observed between the devices. Conclusion:The pain, discomfort levels, and scaling time of the new piezoelectric ultrasonic scaler did not differ from those of the conventional device. Further research and development are necessary for more prominent pain-relief effects of scaling devices.

Association with Combined Occupational Hazards Exposure and Risk of Metabolic Syndrome: A Workers' Health Examination Cohort 2012-2021

  • Dongmug Kang ;Eun-Soo Lee ;Tae-Kyoung Kim;Yoon-Ji Kim ;Seungho Lee ;Woojoo Lee ;Hyunman Sim ;Se-Yeong Kim
    • Safety and Health at Work
    • /
    • 제14권3호
    • /
    • pp.279-286
    • /
    • 2023
  • Background: This study aimed to evaluate the association between exposure to occupational hazards and the metabolic syndrome. A secondary objective was to analyze the additive and multiplicative effects of exposure to risk factors. Methods: This retrospective cohort was based on 31,615 health examinees at the Pusan National University Yangsan Hospital in Republic of Korea from 2012-2021. Demographic and behavior-related risk factors were treated as confounding factors, whereas three physical factors, 19 organic solvents and aerosols, and 13 metals and dust were considered occupational risk factors. Time-dependent Cox regression analysis was used to calculate hazard ratios. Results: The risk of metabolic syndrome was significantly higher in night shift workers (hazard ratio = 1.45: 95% confidence interval = 1.36-1.54) and workers who were exposed to noise (1.15:1.07-1.24). Exposure to some other risk factors was also significantly associated with a higher risk of metabolic syndrome. They were dimethylformamide, acetonitrile, trichloroethylene, xylene, styrene, toluene, dichloromethane, copper, antimony, lead, copper, iron, welding fume, and manganese. Among the 28 significant pairs, 19 exhibited both positive additive and multiplicative effects. Conclusions: Exposure to single or combined occupational risk factors may increase the risk of developing metabolic syndrome. Working conditions should be monitored and improved to reduce exposure to occupational hazards and prevent the development of the metabolic syndrome.

Focal Loss와 앙상블 학습을 이용한 야생조류 소리 분류 기법 (Wild Bird Sound Classification Scheme using Focal Loss and Ensemble Learning)

  • 이재승;유제혁
    • 한국산업정보학회논문지
    • /
    • 제29권2호
    • /
    • pp.15-25
    • /
    • 2024
  • 효과적인 동물 생태계 분석을 위해서는 동물 서식 현황을 자동으로 파악할 수 있는 동물 관제 기술이 중요하다. 특히 울음소리로 종을 판별하는 동물 소리 분류 기술은 영상을 통한 판별이 어려운 환경에서 큰 주목을 받고 있다. 기존 연구들은 단일 딥러닝 모델을 사용하여 동물 소리를 분류하였으나, 야외 환경에서 수집된 동물 소리는 많은 배경 잡음을 포함하여 단일 모델의 판별력을 악화시키며, 종에 따른 데이터 불균형으로 인해 모델의 편향된 학습을 야기한다. 이에, 본 논문에서는 클래스의 데이터 수를 고려하여 페널티를 부여하는 Focal Loss를 사용한 여러 분류 모델의 예측결과를 앙상블을 통해 결합하여 잡음이 많은 동물 소리를 효과적으로 분류할 수 있는 기법을 제안한다. 공개 데이터 셋을 사용한 실험에서, 제안된 기법은 단일 모델의 평균 성능에 비해 Recall 기준으로 최대 22.6%의 성능 개선을 달성하였다.

오디오 정보를 이용한 골프 동영상 자동 색인 알고리즘 (Automatic Indexing Algorithm of Golf Video Using Audio Information)

  • 김형국
    • 한국음향학회지
    • /
    • 제28권5호
    • /
    • pp.441-446
    • /
    • 2009
  • 본 논문에서는 오디오 정보 분석을 이용하여 골프 통영상을 자동 색인하는 알고리즘을 제안한다. 제안하는 알고리즘에서는 입력되는 골프 동영상을 비디오 신호와 오디오 신호로 분리한 후에, 연속적인 오디오 스트림을 Adaboost Cascade 분류방식을 통하여 스튜디오 환경에서의 아나운서의 음성구간, 선수이름이 TV 화면에 소개 될 때 수반되는 음악구간, 선수들의 플레이에 따라 반응하는 관중들의 박수 및 환호성 소리구간, 필드에서의 레포터의 음성구간, 바다나 바람 등의 필드환경 잡음 사운드구간 등의 5가지 구간으로 분류한다. 그리고 드라이브 샷, 아이런 샷과 퍼팅 샷 시에 발생하는 스윙 사운드는 onset 검출과 변조스펙트럼 검증 방법을 통해 검출되며, 관객의 박수 소리 구간과 결합하여 액션 및 하이라이트를 효율적으로 색인할 수 있게 한다. 제안된 알고리즘은 오디오 신호의 간단한 연산을 통해 의미를 지니고 있는 기본구조들을 검출하기 때문에 골프 동영상에서 사용자가 원하는 부분을 빠르게 브라우징하는 임베이디드 시스템에 적용가능하다.

PET/CT 검사에서 영상의 질을 유지하기 위한 적정한 $^{18}F$-FDG 투여량의 평가 (Evaluation of Reasonable $^{18}F$-FDG Injected Dose for Maintaining the Image Quality in 3D WB PET/CT)

  • 문아름;이혁;곽인석;최성욱;석재동
    • 핵의학기술
    • /
    • 제15권2호
    • /
    • pp.36-40
    • /
    • 2011
  • PET/CT 검사에서 환자에게 주입되는 $^{18}F$-FDG 투여량은 장비업체에서 제시하는 권고치와 각 병원에서 적용하는 기준치가 서로 다르다. 기준치의 차이로 인한 부적절한 $^{18}F$-FDG 투여량은 환자의 피폭선량을 증가시키고 영상의 질을 감소시킬 수 있다. 본 실험에서는 PET/CT 검사에서 영상의 질을 유지하면서 환자의 피폭선량을 감소시킬 수 있는 적정한 $^{18}F$-FDG 투여량에 대한 평가를 하고자 한다. 모형 실험은 NEMA NU2-1994를 이용하여 열소와 배후 방사능비를 4:1로 유지한 상태에서 열소의 방사능 농도를 1, 3, 5, 7, 9 MBq/kg으로 증가시키며 $^{18}F$-FDG를 주입하였다. CT를 이용한 투과촬영 후 2분 30초/bed의 방출영상을 3차원 (3D) 모드로 획득하였다. 열소와 배후방사능 부위에 각각 관심영역을 설정하고 최대 표준섭취계수(Standard Uptake Value maximum, $SUV_{max}$)를 얻은 후 해당 위치에서의 신호대 잡음비(Signal to Noise Ratio, SNR)를 비교 분석하였다. 임상실험은 2009년 11월부터 2010년 8월까지 내원한 환자를 대상으로 PET/CT 검사를 시행한 환자영상에서 간병변이 없는 97명의 환자를 선별하여 간(liver)과 대퇴부(thigh) 영역에 관심영역을 설정하고 $SUV_{max}$를 측정하여 투여량에 따른 영상의 차이를 비교 분석하였다. 모형 실험에서 단위 질량 당 주입된 방사능 농도는 1, 3, 5, 7, 9 MBq/kg으로 $SUV_{max}$는 23.1, 24.1, 24.3, 22.8, 23.6, SNR은 0.48, 0.54, 0.56, 0.55, 0.55로 나타났다. 5 MBq/kg 이하의 방사능 농도에서는 투여량의 증가에 따라 $SUV_{max}$와 SNR이 증가하지만 7 MBq/kg 이상에서는 감소하였다. 임상 실험의 경우는 단위 질량 당 주입된 방사능 농도가 4.72, 5.34, 6.16, 7.41, 8.68 MBq/kg으로 증가할수록 $SUV_{max}$는 2.68, 2.67, 2.26, 1.88, 1.95, SNR이 0.52, 0.53, 0.46, 0.46, 0.44로 5 MBq/kg의 투여량을 초과할 경우 모형 실험에서와 같은 감소양상을 보였다. 환자의 체중을 고려한 $^{18}F$-FDG 투여량의 증가는 일정 범위 내에서 영상의 질을 향상시키지만 그 범위를 초과할 경우 우발동시계수 및 산란계수의 증가로 인하여 오히려 영상의 질이 저하된다. 실험 결과로부터 3D PET/CT 검사 시 단위질량 당 주입된 방사능 농도 5 MBq/kg이 최적의 주입선량이라는 것을 알 수 있다.

  • PDF

정적 영상에서 Noise Reduction Software의 이해와 적용 (The Understanding and Application of Noise Reduction Software in Static Images)

  • 이형진;송호준;승종민;최진욱;김진의;김현주
    • 핵의학기술
    • /
    • 제14권1호
    • /
    • pp.54-60
    • /
    • 2010
  • 본원에 도입된 새로운 소프트웨어는 SPECT나 전신 뼈 영상에만 국한되어 사용되어 지고 있지만 보다 효과적으로 다른 검사에 적용하기 위해 팬텀을 통한 실험과 영상의 비교를 통하여 그 유용성을 찾아보고자 하였다. 실험을 위하여 Body IEC phantom과 Jaszczak ECT phantom, Capillary를 이용한 실린더 팬텀을 이용하였고, 영상의 처리 전후의 계수, statistics를 비교해 보고 contrast ratio나 BKG의 변화들을 정량적으로 분석해 보았다. Capillary source를 이용한 FWHM 비교에서는 PIXON의 경우 처리 전후의 영상에서 차이가 거의 없었고, ASTONISH의 경우 처리 후의 영상이 우수해짐을 확인할 수 있었다. 반면 Standard deviation과 그에 따른 Variance는 PIXON은 다소 감소한 반면 ASTONISH는 큰 폭으로 증가함을 보였다. IEC phantom을 이용한 BKG variability 비교에서는 PIXON의 경우 전체적으로 감소한 반면 ASTONISH는 다소 증가하는 경향을 보였고, 각각의 sphere에 대한 contrast ratio도 두 가지 방법 모두 향상됨을 확인하였다. 영상의 스케일 면에서도 PIXON의 경우 처리 후에는 window width가 약 4-5배 증가하였지만 ASTONISH에서는 큰 차이가 없었다. 팬텀 실험 분석 후 ASTONISH는 정량적 분석을 위해 ROI를 그려야 하는 기타 검사와 대조도를 강조하는 검사에 적용 가능성을 보였고, PIXON은 획득계수가 부족하거나 SNR이 낮은 핵의학 검사에 유용하게 사용될 것으로 생각되었다. 영상의 분석 인자로 많이 사용되는 정량적인 수치들은 소프트웨어의 적용 후 대체로 향상되었지만 감마카메라의 차이보다 소프트웨어간의 알고리즘 특성으로 인한 결과영상의 차이가 많아 모든 핵의학 검사의 적용에 있어서 일관성을 유지하기는 어려울 것으로 사료된다. 또한 전신 뼈 영상과 같이 검사시간의 획기적 단축과 같은 수단으로는 우수한 영상의 질을 기대하기 어렵다. 새로운 소프트웨어의 도입 시 병원의 특성에 맞는 protocol과 임상 적용 전에 많은 연구가 필요할 것으로 사료된다.

  • PDF