• Title/Summary/Keyword: background noise

Search Result 965, Processing Time 0.025 seconds

Inspection of Coin Surface Defects using Multiple Eigen Spaces (다수의 고유 공간을 이용한 주화 표면 품질 진단)

  • Kim, Jae-Min;Ryoo, Ho-Jin
    • The Journal of the Korea Contents Association
    • /
    • v.11 no.3
    • /
    • pp.18-25
    • /
    • 2011
  • In a manufacturing process of metal coins, surface defects of coins are manually detected. This paper describes an new method for detecting surface defects of metal coins on a moving conveyor belt using image processing. This method consists of multiple procedures: segmentation of a coin from the background, alignment of the coin to the model, projection of the aligned coin to the best eigen image space, and detection of defects by comparison of the projection error with an adaptive threshold. In these procedures, the alignement and the projection are newly developed in this paper for the detection of coin surface defects. For alignment, we use the histogram of the segmented coin, which converts two-dimensional image alignment to one-dimensional alignment. The projection reduces the intensity variation of the coin image caused by illumination and coin rotation change. For projection, we build multiple eigen image spaces and choose the best eigen space using estimated coin direction. Since each eigen space consists of a small number of eigen image vectors, we can implement the projection in real- time.

Therapeutic Effects of Extract of Uncariae Ramulis and Testudinis Plastrum on Cochlear Morphologic Change Induced by Salicylate Ototoxicity (귀판 합 조구등 추출액이 살리실산 나트륨으로 유발된 와우의 형태학적 변화에 미치는 영향)

  • Ha Mi-Kyung;Ku Young-Hui;Choi In-Hwa
    • The Journal of Korean Medicine
    • /
    • v.25 no.3
    • /
    • pp.160-168
    • /
    • 2004
  • Background and Objectives: Tinnitus is on the increase due to the increase in the elderly population, industrial pollution and noise pollution. This symptom is especially marked in patients with a hearing problem and the relationship between cause, mechanism and treatment is poorly understood. The characteristics of tinnitus and other hearing problems are well brought out using an animal model with salicylate ototoxicity. Therapeutic effects of Uncariae Ramulis and Testudinis Plastrum were expected in tinnitus and hearing problems; therefore we experimented on an animal model with salicylate ototoxicity. Salicylate is one of the most commonly prescribed drugs, although it has been recognized that salicylate induces hearing loss and tinnitus reversibly. The purpose of this study was to find the therapeutic effects of this by the morphologic study using salicylate ototoxicity. Materials and Methods : Twelve healthy Sprague-Dawley rats were divided into three groups: normal, control and sample. The sample group was treated with the extract of Uncariae Ramulis and Testudinis Plastrum (1cc/100g, once a day for 6 days). Then, to induce the salicylate ototoxicity in the control and sample groups, rats were injected intraperitoneally with sodium salicylate (500mg/kg). We observed the morphologic changes in the cochlea of the rats every 2, 3, 4 and 5 hours after injection. Results : The outer hair cells showed marked changes. Vacuolization formed in the cuticular plate and the endoplasm of the control group. The endoplasm and the cuticular plates of the sample group after 2 hours were similar to the control group, but the cuticular plates of the sample group observed after 3, 4 and 5 hours were not similar. Conclusions : The results suggest that an extract of Uncariae Ramulis and Testudinis Plastrum has therapeutic effects on an animal model with salicylate ototoxicity.

  • PDF

Analysis of Pre and Post-Operative Speech In Combined Operation of Type I Thyroplasty and Arytenoid Adduction for Unilateral Vocal Cord Palsy (편측성대마비에 대한 제 1형 갑상성형술과 피열연골내전술의 동시수술시 술전 및 술후 음성언어분석비교)

  • 최홍식;정유삼;김성국;김영호;김광문
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.9 no.1
    • /
    • pp.66-70
    • /
    • 1998
  • Background and Objectives : The managements of unilateral vocal cord palsy include type Ⅰ thyroplasty and arytenoid adduction. One type operation has been shown no satisfactory effect. We evaluated preoperative and postoperative speech of unilateral vocal cord palsy patients who received combined operation of type Ⅰ thyroplasty and arytenoid adduction to help for the management plan of unilateral vocal cord palsy patients. Materials and Methods : We reviewed the postoperative results and complication of 17 surgically treated patients of unilateral vocal cord palsy at Severance hospital from Nov. 1996 to Dec. 1997 retrospectively. They were received combined operation of type Ⅰ thyroplasty and arytenoid adduction. Their pre and post-operative speech were analyzed with MDVP(Multi-Dimension-Voice analysis Program) of CSL(Computerized Speech Lab). Results : After the operation, MPT(Maximal Phonation Time) was increased and MFR(Mean Flow Rate) was decreased in all patients. NHR(Noise to Harmonic Ratio) and VTI(Voice Turbulence Index) were decreased : liner, RAP(Relative Average Perturbation Quotient), PPQ(Pitch Period Perturbation Quotient), sPPQ(smoothed Pitch Period Perturbation Quotient), vFo(fundamental frequency Variation) were decreased : Shimmer, APQ(Amplitude Perturbation Quotient), sAPQ(Smoothed Amplitude Perturbation Qoutient), vAm(Peak Amplitude Variation) were decreased in all the patients. Conclusions : In unilateral vocal cord pals), combined operation of type Ⅰ thyroplasty and arytenoid adduction could obtain satisfactory postoperative voice. MDVP has many parameters and good method for evaluation of voice surgery.

  • PDF

Development Of Manually Controlled Jet Ventilation (Manujet) and It's Clinical Application : A Prospective Study (수동조절형 제트환기장치(Manujet)의 개발 및 임상적용 : 전향적 연구)

  • Kwon, Ki-Nam;Kim, Kyu-Hun;Moon, Il-Ha;Lee, Yu-Jea;Yu, Hye-Jin;Tae, Ki-Yeon;Lee, Seung-Woon
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.22 no.2
    • /
    • pp.133-136
    • /
    • 2011
  • Background and Objectives : Previous jet ventilation is not becoming more common because of high price, making loud noise, and causing a movement of the vocal cords due to the jet stream. So we designed a new type of manually controlled jet ventilation using previous laryngoscope and introduced it's clinical application. Materials and Method : A prospective study involved 20 patients all having undergone surgical intervention under new type of manually controlled jet ventilation from June 2009 to January 2011. The prospective study was to assess the vital sign and operative and postoperative complications. Results : The Manually Controlled Jet Ventilation were performed in 20 patients. 50% of the patients have Post-located laryngeal lesion, 20% with tracheal stenosis, 20% with glottic cancer biopsy and laser cordectomy, 10% with postglottic stenosis. Conclusion : Manually Controlled Jet Ventilation (Manujet) can be used for airway surgery.

  • PDF

Comparative Study on Usefulness of SPAIR and STIR Fast SE T2-weighted 3T Magnetic Resonance Imaging (3T 고속스핀에코 T2강조영상에서 지방소거 반전회복기법의 유용성 연구 - SPAIR와 STIR와의 비교 -)

  • Lee, Hoo-Min;Yoon, Joon;Yeo, Young-Bok
    • Journal of radiological science and technology
    • /
    • v.33 no.1
    • /
    • pp.45-50
    • /
    • 2010
  • In this study, we compared the clinical usefulness of SPAIR (Spectral Adiabatic Inversion Recovery) and STIR (Short TI Inversion Recovery) to evaluate the fat tissues precisely. The images of brain axial (n = 20), lumber spine sagittal (n = 20), hip joint coronal (n = 17) and knee joint (n = 25) were obtained by turbo spin echo T2 weighted method on 3T magnetic resonance image. The signal intensity (SI) values were measured using region of interest in fat, muscle tissue, and background noise. The inhomogeneity values were measured using the standard deviation (SD) value divided by the mean values. SD signifies the amount of error which is similar to the imaging heterogeneity. In brain axial images, the SPAIR showed more superior SI and inhomogeneity results than the STIR. In spine, hip and knee images, STIR showed more excellent SI results, but poor inhomogeneity than the SPAIR.

A Study of Analytical Sensitivity on TDM Test Kit in Clinical Chemistry (약물검사 키트의 분석 민감도에 대한 연구)

  • Chang, Sang Wu;Kim, Nam Yong;Lee, Hee Gyung;Kim, Hyun Jung;Lee, Yun Jung;Jin, Ok Bae;Kim, Mi Gyung
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.36 no.2
    • /
    • pp.127-130
    • /
    • 2004
  • Analytical sensitivity on TDM test is the lowest concentration that can be distinguished from background noise. The aim of study was to evaluate analytical sensitivity that is also referred to as the lower limit of detection(LLD) about difference between zero calibrator and isotonic saline sample. We tested for 10 days with zero calibrators and 0.85% saline samples while running trilevel control samples under control. Raw data divided by two groups calculated mean and standard deviation from two sample populations and analytical sensitivity by ${\bar{X}}+2SD$. In comparison with isotonic saline samples and zero calibrators, there were significant differences in phenytoin, phenobarbital and vancomycin, etc. Especially analytical sensitivity on phenytoin is at the same level as the upper limit of analytical measurement range with $40{\mu}g/mL$. We think the cause of this is matrix interference. In conclusion, we were sure that standard protocol for analytical sensitivity as lower limit of analytical measurement range on TDM test must be measured with zero standard rather than an isotonic saline sample and type 1 reagent DW for reducing matrix effects within interactions between different materials in a mixture.

  • PDF

Studies on Voice Changes Associated with Alcohol Intake (음주에 따른 음성 변화에 대한 고찰)

  • Kim, Jung-Hyun;Yoon, Je-Hwan;Cho, Hyung-Ho;Cho, Yeon;Cho, Jae-Sik
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.13 no.1
    • /
    • pp.18-22
    • /
    • 2002
  • Background and Objectives : It has been pointed out that alcohol intake in human beings induces changes in voice register and maximum phonation time. These changes supposedly result from injection of the vibratory vocal folds. The purpose of this study was to clarify the voice changes associated with alcohol intake and the changes of laryngeal mucosa. Materials and Methods : The subjects included 29 volunteers, including 20 men and 9 women ranging in age from 22 to 31 years. Alcohol intake was accomplished by oral administration of 23% soju 1 bottle (255cc). Serum alcohol concentration levels were evaluated hourly for 3 h after ingestion of alcohol. Seven measurements were performed at pre-alcohol intake and post-alcohol intake hourly : fundamental frequency, jitter, shimmer, noise to harmonic ratio as the acoustic analysis, maximal phonation time, mean flow rate, and subglottal pressure as the aerodynamic analysis. The changes of laryngeal mucosa were evaluated by flexible laryngoscope at each measurement. Results : By comparing the acoustic and aerodynamic data and laryngeal mucosa before and after alcohol intake, there were not remarkable changes (p>0.05). Conclusion : The voice and laryngeal mucosa have not remarkably changed according to alcohol concentration in this study. Furthermore studies on the voice change induced by multiple alcohol concentrations are required.

  • PDF

Speech Quality Estimation Algorithm using a Harmonic Modeling of Reverberant Signals (반향 음성 신호의 하모닉 모델링을 이용한 음질 예측 알고리즘)

  • Yang, Jae-Mo;Kang, Hong-Goo
    • Journal of Broadcast Engineering
    • /
    • v.18 no.6
    • /
    • pp.919-926
    • /
    • 2013
  • The acoustic signal from a distance sound source in an enclosed space often produces reverberant sound that varies depending on room impulse response. The estimation of the level of reverberation or the quality of the observed signal is important because it provides valuable information on the condition of system operating environment. It is also useful for designing a dereverberation system. This paper proposes a speech quality estimation method based on the harmonicity of received signal, a unique characteristic of voiced speech. At first, we show that the harmonic signal modeling to a reverberant signal is reasonable. Then, the ratio between the harmonically modeled signal and the estimated non-harmonic signal is used as a measure of standard room acoustical parameter, which is related to speech clarity. Experimental results show that the proposed method successfully estimates speech quality when the reverberation time varies from 0.2s to 1.0s. Finally, we confirm the superiority of the proposed method in both background noise and reverberant environments.

Dynamic Amplification Characteristics of Major Domestic Seismic Observation Sites using Ground Motions from Domestic Macro Earthquakes (국내 중규모지진의 자료를 이용한 주요 관측소 지반의 동적 증폭특성에 관한 연구)

  • Kim, Jun Kyoung
    • The Journal of Engineering Geology
    • /
    • v.22 no.4
    • /
    • pp.399-408
    • /
    • 2012
  • To estimate seismic source and soil-structure interaction more reliably, site amplification characteristics should be considered. Among the various estimation methods, we used Nakamura's method (1989) to estimate site amplification. This method was originally applied to background noise; however, it has recently been successfully applied to S-wave and Coda-wave energy, and is applied to S-waves in the present study. We used more than 180 observed ground motions from 23 macro-earthquakes and then analyzed site amplification characteristics at eight seismic stations. Each station showed characteristics of site amplification properties in the low-, high- and resonance-frequency ranges. Comparison of the present results with those of other studies provide successful information regarding the dynamic amplification of domestic site characteristics and site classification.

Feasibility of Galaxy Smartphone Recording as Portable Recorder for Acoustic Analysis of Voice (음향분석에 사용할 녹음장비로 갤럭시 스마트폰 녹음기능의 유용성)

  • Yun, Mae-Hwa;Lee, Jae-Hyuk;Lee, Sang-Hyuk;Jin, Sung-Min
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.26 no.2
    • /
    • pp.104-111
    • /
    • 2015
  • Background and Objectives : Acoustic analysis of voice could be influenced so much by the quality of voice files which were recorded by recording device. In clinical practice, voice files that were recorded by analysis program directly or portable digital recording device were analyzed mostly. This study examined the feasibility of using Galaxy smartphone recordings for acoustic analysis of voice. Materials and Methods : Acoustic measures were compared between voice signals recorded from 30 normal speakers (15 males and 15 females) through Galaxy smartphone, portable digital recording device and CSL. Fo, jitter, shimmer, NHR (Noise-Harmony ratio) and Formant frequencies were analyzed by MDVP. Results : Fo, Jitter, Shimmer, NHR and formant frequencies from 3 devices were no significantly difference. The intraclass correlation coefficient (ICC) was higher between each of the voice perturbation measures. Conclusion : The findings indicated that Galaxy smartphone recording system was useful device for acoustic analysis of voice. Furthermore, Galaxy smartphone can be applied widely in various way for acoustic analysis of voice.

  • PDF