• Title/Summary/Keyword: background count

Search Result 329, Processing Time 0.037 seconds

Linearity Estimation of PET/CT Scanner in List Mode Acquisition (List Mode에서 PET/CT Scanner의 직선성 평가)

  • Choi, Hyun-Jun;Kim, Byung-Jin;Ito, Mikiko;Lee, Hong-Jae;Kim, Jin-Ui;Kim, Hyun-Joo;Lee, Jae-Sung;Lee, Dong-Soo
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.1
    • /
    • pp.86-90
    • /
    • 2012
  • Purpose: Quantification of myocardial blood flow (MBF) using dynamic PET imaging has the potential to assess coronary artery disease. Rb-82 plays a key role in the clinical assessment of myocardial perfusion using PET. However, MBF could be overestimated due to the underestimation of left ventricular input function in the beginning of the acquisition when the scanner has non-linearity between count rate and activity concentration due to the scanner dead-time. Therefore, in this study, we evaluated the count rate linearity as a function of the activity concentration in PET data acquired in list mode. Materials & methods: A cylindrical phantom (diameter, 12 cm length, 10.5 cm) filled with 296 MBq F-18 solution and 800 mL of water was used to estimate the linearity of the Biograph 40 True Point PET/CT scanner. PET data was acquired with 10 min per frame of 1 bed duration in list mode for different activity concentration levels in 7 half-lives. The images were reconstructed by OSEM and FBP algorithms. Prompt, net true and random counts of PET data according to the activity concentration were measured. Total and background counts were measured by drawing ROI on the phantom images and linearity was measured using background correction. Results: The prompt count rates in list mode were linearly increased proportionally to the activity concentration. At a low activity concentration (<30 kBq/mL), the prompt net true and random count rates were increased with the activity concentration. At a high activity concentration (>30 kBq/mL), the increasing rate of the prompt net true rates was slightly decreased while the increasing rate of random counts was increased. There was no difference in the image intensity linearity between OSEM and FBP algorithms. Conclusion: The Biograph 40 True Point PET/CT scanner showed good linearity of count rate even at a high activity concentration (~370 kBq/mL).The result indicates that the scanner is useful for the quantitative analysis of data in heart dynamic studies using Rb-82, N-13, O-15 and F-18.

  • PDF

Counting Strategies in Radioactivity Measurement for the Monitoring and Screening (방사능 존재확인과 정량분석시 최적화된 측정시간의 결정을 위한 계측전략)

  • Seo, Kyung-Won
    • Journal of Radiation Protection and Research
    • /
    • v.23 no.2
    • /
    • pp.65-74
    • /
    • 1998
  • One of the important things in low level radioactivity measurement is determination of the optimized counting time. Counting strategy has to be established, in order to count the radioactivity of the sample by condition of optimized measurement. There were three kinds of counting strategies in this report ; about fixed time, about fixed count, to compared sample, background, and reference level. The best of them was satisfied rendition to give about condition of instrument and process, as an example, efficiency of detector, counter capacity, maximum and average background count rate of counter, reference level and limit of derision and detection, etc. Therefore, we can decide the optimized counting time in the screening and monitoring. And we can save the time for courting the sample of course the data of count will be counted by optimized accuracy finally, in rountine measurement of radioactivity these strategies will be used available.

  • PDF

Statistical Analysis of Count Rate Data for On-line Seawater Radioactivity Monitoring

  • Lee, Dong-Myung;Cong, Binh Do;Lee, Jun-Ho;Yeo, In-Young;Kim, Cheol-Su
    • Journal of Radiation Protection and Research
    • /
    • v.44 no.2
    • /
    • pp.64-71
    • /
    • 2019
  • Background: It is very difficult to distinguish between a radioactive contamination source and background radiation from natural radionuclides in the marine environment by means of online monitoring system. The objective of this study was to investigate a statistical process for triggering abnormal level of count rate data measured from our on-line seawater radioactivity monitoring. Materials and Methods: Count rate data sets in time series were collected from 9 monitoring posts. All of the count rate data were measured every 15 minutes from the region of interest (ROI) for $^{137}Cs$ ($E_{\gamma}=661.6keV$) on the gamma-ray energy spectrum. The Shewhart ($3{\sigma}$), CUSUM, and Bayesian S-R control chart methods were evaluated and the comparative analysis of determination methods for count rate data was carried out in terms of the false positive incidence rate. All statistical algorithms were developed using R Programming by the authors. Results and Discussion: The $3{\sigma}$, CUSUM, and S-R analyses resulted in the average false positive incidence rate of $0.164{\pm}0.047%$, $0.064{\pm}0.0367%$, and $0.030{\pm}0.018%$, respectively. The S-R method has a lower value than that of the $3{\sigma}$ and CUSUM method, because the Bayesian S-R method use the information to evaluate a posterior distribution, even though the CUSUM control chart accumulate information from recent data points. As the result of comparison between net count rate and gross count rate measured in time series all the year at a monitoring post using the $3{\sigma}$ control charts, the two methods resulted in the false positive incidence rate of 0.142% and 0.219%, respectively. Conclusion: Bayesian S-R and CUSUM control charts are better suited for on-line seawater radioactivity monitoring with an count rate data in time series than $3{\sigma}$ control chart. However, it requires a continuous increasing trend to differentiate between a false positive and actual radioactive contamination. For the determination of count rate, the net count method is better than the gross count method because of relatively a small variation in the data points.

Systemic White Blood Cell Count as a Biomarker Associated with Severity of Chronic Obstructive Lung Disease

  • Koo, Hyeon-Kyoung;Kang, Hyung Koo;Song, Pamela;Park, Hye Kyeong;Lee, Sung-Soon;Jung, Hoon
    • Tuberculosis and Respiratory Diseases
    • /
    • v.80 no.3
    • /
    • pp.304-310
    • /
    • 2017
  • Background: Chronic obstructive pulmonary disease (COPD), is a chronic inflammatory disorder. We evaluated whether white blood cell (WBC) count, is associated with the severity of COPD, independent of other inflammatory conditions, such as metabolic syndrome. Methods: The WBC counts were compared between 1227 COPD patients and 8679 non-COPD adults older than 40. The relationships between the WBC count, lung function, and symptoms score in COPD patients, were determined, using general linear regression analyses. Results: The WBC count was negatively associated with forced vital capacity (FVC, L), FVC (% predicted), forced expiry volume in one second ($FEV_1$, L), and $FEV_1$ (% predicted) in COPD patients. Additionally, the WBC count was independently associated with the quality of life measure, by EQ5D-index score. However, this relationship between WBC count, and disease severity, was not significant in current smokers, because of the confounding effect of smoking, on the WBC count. Conclusion: The WBC count is associated with current smoking status and COPD severity, and a risk factor for poor lung function, and quality of life, especially in non-currently smoking COPD patients. The WBC count can be used, as an easily measurable COPD biomarker.

Complete Blood Count Reference Intervals and Patterns of Changes Across Pediatric, Adult, and Geriatric Ages in Korea

  • Nah, Eun-Hee;Kim, Suyoung;Cho, Seon;Cho, Han-Ik
    • Annals of Laboratory Medicine
    • /
    • v.38 no.6
    • /
    • pp.503-511
    • /
    • 2018
  • Background: Sampling a healthy reference population to generate reference intervals (RIs) for complete blood count (CBC) parameters is not common for pediatric and geriatric ages. We established age- and sex-specific RIs for CBC parameters across pediatric, adult, and geriatric ages using secondary data, evaluating patterns of changes in CBC parameters. Methods: The reference population comprised 804,623 health examinees (66,611 aged 3-17 years; 564,280 aged 18-59 years; 173,732 aged 60-99 years), and, we excluded 22,766 examinees after outlier testing. The CBC parameters (red blood cell [RBC], white blood cell [WBC], and platelet parameters) from 781,857 examinees were studied. We determined statistically significant partitions of age and sex, and calculated RIs according to the CLSI C28-A3 guidelines. Results: RBC parameters increased with age until adulthood and decreased with age in males, but increased before puberty and then decreased with age in females. WBC and platelet counts were the highest in early childhood and decreased with age. Sex differences in each age group were noted: WBC count was higher in males than in females during adulthood, but platelet count was higher in females than in males from puberty onwards (P <0.001). Neutrophil count was the lowest in early childhood and increased with age. Lymphocyte count decreased with age after peaking in early childhood. Eosinophil count was the highest in childhood and higher in males than in females. Monocyte count was higher in males than in females (P <0.001). Conclusions: We provide comprehensive age- and sex-specific RIs for CBC parameters, which show dynamic changes with both age and sex.

Noninvasive markers for esophageal varices in children with cirrhosis

  • Rahmani, Parisa;Farahmand, Fatemeh;Heidari, Ghobad;Sayarifard, Azadeh
    • Clinical and Experimental Pediatrics
    • /
    • v.64 no.1
    • /
    • pp.31-36
    • /
    • 2021
  • Background: The diagnosis of esophageal varices (EV) is based on the findings of esophagogastroduodenoscopy (EGD), biopsy, and serum markers. Thus, noninvasive cost-effective tests through which high-risk EV children can be diagnosed are needed. Purpose: This cross-sectional study aimed to identify the noninvasive markers for EV in children with liver cirrhosis. Methods: A total of 98 children with liver cirrhosis were evaluated in this study. The spleen size, platelet count, serum albumin, liver function test results, and risk scores were evaluated prior to endoscopy. The endoscopic investigations aimed to identify the presence of EV and red signs, and determine varices sizes. Results: Endoscopy revealed varices in 43 subjects (43.9%). The spleen size, platelet count, international normalized ratio, aspartate aminotransferase to platelet ratio index (APRI), platelet count to spleen size ratio, and risk score differed significantly between patients with and without EV on univariate analysis; however, the logistic regression analysis showed no differences, indicating that none of these parameters were independently associated with the presence of EV. Conclusion: Platelet count, risk score, platelet count to spleen size, and APRI can be useful tools for the identification of high-risk patients with EV and might reduce the need for invasive methods like EGD.

ON THE BACKGROUND-SUBTRACTED INTENSITY (백그라운드 제거후 신호의 세기에 대하여)

  • Seon, Kwang-Il
    • Publications of The Korean Astronomical Society
    • /
    • v.20 no.1 s.24
    • /
    • pp.109-116
    • /
    • 2005
  • When we measure a source signal in the presence of a background rate that has been independently measured, the usual approach is to obtain an estimate of the background rate by observing an empty part of the sky, and an estimate of the source signal plus background rate by observing the region where a source signal is expected. The source signal rate is then estimated by subtracting the background rate from the source signal plus background rate. However, when the rates or their observation times are small, this procedure can lead to negative estimates of the source signal rate, even when it should produce a positive value. By applying the Bayesian approach, we solve the problem and prove that the most probable value of source signal rate is zero when the observed total count is smaller than the expected background counts. It is also shown that the results from the conventional method is consistent with the most probable value obtained from the Bayesian approach when the source signal is large or the observation time is long enough.

In Situ Gamma-ray Spectrometry Using an LaBr3(Ce) Scintillation Detector

  • Ji, Young-Yong;Lim, Taehyung;Lee, Wanno
    • Journal of Radiation Protection and Research
    • /
    • v.43 no.3
    • /
    • pp.85-96
    • /
    • 2018
  • Background: A variety of inorganic scintillators have been developed and improved for use in radiation detection and measurement, and in situ gamma-ray spectrometry in the environment remains an important area in nuclear safety. In order to verify the feasibility of promising scintillators in an actual environment, a performance test is necessary to identify gamma-ray peaks and calculate the radioactivity from their net count rates in peaks. Materials and Methods: Among commercially available scintillators, $LaBr_3(Ce)$ scintillators have so far shown the highest energy resolution when detecting and identifying gamma-rays. However, the intrinsic background of this scintillator type affects efficient application to the environment with a relatively low count rate. An algorithm to subtract the intrinsic background was consequently developed, and the in situ calibration factor at 1 m above ground level was calculated from Monte Carlo simulation in order to determine the radioactivity from the measured net count rate. Results and Discussion: The radioactivity of six natural radionuclides in the environment was evaluated from in situ gamma-ray spectrometry using an $LaBr_3(Ce)$ detector. The results were then compared with those of a portable high purity Ge (HPGe) detector with in situ object counting system (ISOCS) software at the same sites. In addition, the radioactive cesium in the ground of Jeju Island, South Korea, was determined with the same assumption of the source distribution between measurements using two detectors. Conclusion: Good agreement between both detectors was achieved in the in situ gamma-ray spectrometry of natural as well as artificial radionuclides in the ground. This means that an $LaBr_3(Ce)$ detector can produce reliable and stable results of radioactivity in the ground from the measured energy spectrum of incident gamma-rays at 1 m above the ground.

Nasal eosinophilia and eosinophil peroxidase in children and adolescents with rhinitis

  • Choi, Yeonu;Jeon, Haeun;Yang, Eun Ae;Yoon, Jong-Seo;Kim, Hyun Hee
    • Clinical and Experimental Pediatrics
    • /
    • v.62 no.9
    • /
    • pp.353-359
    • /
    • 2019
  • Background: Researchers have shown that eosinophil peroxidase (EPO) is a relatively accurate marker of eosinophilia and eosinophil activity. However, its use as a marker of eosinophilic inflammation in nasal secretions is limited because the diagnostic cutoff values of EPO for use as a one-time test for allergic diseases such as allergic rhinitis have not been established. Purpose: To identify the correlation between nasal eosinophil count and EPO in children and adolescents with rhinitis. Methods: We recruited patients <18 years of age with rhinitis for more than 2 weeks or more than 2 episodes a year whose nasal eosinophil and EPO were measured at a single allergy clinic. The eosinophil percentage was calculated by dividing the eosinophil count by the number of total cells under light microscopy at ${\times}1,000$ magnification. EPO and protein were measured from nasal secretions. We retrospectively analyzed the correlation between nasal eosinophils and protein-corrected EPO (EPO/protein) value. Results: Of the 67 patients enrolled, 41 were male (61.2%); the mean age was $8.2{\pm}4.0years$. The median nasal eosinophil count was 1 and percentage was 1%. The median protein-corrected EPO value was $12.5ng/{\mu}g$ (range, $0-31ng/{\mu}g$). There was a statistically significant correlation between eosinophil count and percentage (P<0.001). However, the eosinophil percentage and EPO did not correlate. The eosinophil count and EPO had a statistically significant correlation (P=0.01). The EPO cutoff value examined for nasal eosinophil counts of 2, 5, 10, and 20 was $17.57ng/{\mu}g$ regardless of the reference count. The largest area under the curve value was obtained when the receiver operating characteristic curve was drawn using the eosinophil count of 2. Conclusion: Nasal eosinophil count was significantly associated with protein-corrected EPO.

Face and Hand Tracking using MAWUPC algorithm in Complex background (복잡한 배경에서 MAWUPC 알고리즘을 이용한 얼굴과 손의 추적)

  • Lee, Sang-Hwan;An, Sang-Cheol;Kim, Hyeong-Gon;Kim, Jae-Hui
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.39 no.2
    • /
    • pp.39-49
    • /
    • 2002
  • This paper proposes the MAWUPC (Motion Adaptive Weighted Unmatched Pixel Count) algorithm to track multiple objects of similar color The MAWUPC algorithm has the new method that combines color and motion effectively. We apply the MAWUPC algorithm to face and hand tracking against complex background in an image sequence captured by using single camera. The MAWUPC algorithm is an improvement of previously proposed AWUPC (Adaptive weighted Unmatched Pixel Count) algorithm based on the concept of the Moving Color that combines effectively color and motion information. The proposed algorithm incorporates a color transform for enhancing a specific color, the UPC(Unmatched Pixel Count) operation for detecting motion, and the discrete Kalman filter for reflecting motion. The proposed algorithm has advantages in reducing the bad effect of occlusion among target objects and, at the same time, in rejecting static background objects that have a similar color to tracking objects's color. This paper shows the efficiency of the proposed MAWUPC algorithm by face and hands tracking experiments for several image sequences that have complex backgrounds, face-hand occlusion, and hands crossing.