• Title/Summary/Keyword: back-analyses

Search Result 390, Processing Time 0.038 seconds

Amino Acid Structure of Dopamine Transporter Responsible for Cocaine Binding (코카인 결합과 관련된 도파민 수송체의 아미노산 구조)

  • 장미윤;전대준;오동렬;이용성;이상훈
    • YAKHAK HOEJI
    • /
    • v.43 no.6
    • /
    • pp.743-750
    • /
    • 1999
  • Human and bovine dopamine transporters (DAT) demonstrate discrete functional differences in the dopamine (DA) transport and cocaine binding. The functional analyses on the chimeras of human and bovine DAT have revealed that the region from the $133^{rd}{\;}to{\;}186^{th}$ residue(encompassing the $3^{rd}$ trans-membrane domain (TM) is responsible for the substrate transport and cocaine binding. The present studies have been done to find out the specific amino acid(s) which is essential for the binding of cocaine to DAT by interchanging the amino acids in that region between human and bovine DAT. When isoleucine, the $152^{nd}$ residue of chimera B3 (bovine DAT sequence) was transformed back to valine, the human DAT residue at the identical position, the cocaine binding was remarkably recovered to 98% of the human DAT values. In addition, the cocaine binding of the human DAT was decreased by 57% by substituting isoleucine for valine at position 152. When isoleucine at position 152 of the chimera B3 was converted to the other amino acids to provide an possible molecular basis for the functional role of the $152^{nd}$ residue, only the conversion to alanine among acids tested significantly the cocaine by 34%, but these effect were not as much as those by the conversion to valine. In conclusion, valine at position 152 is a crucial amino acid for the interaction of cocaine to the DAT.

  • PDF

Model Tests for the Applicability of various Testing Devices for Measuring Degree of Compaction (여러 가지 다짐평가 장비의 적용성에 대한 모형 시험)

  • Back, In-Chul;Yoo, Wan-Kyu;Kim, Byoung-Il;Kim, Ju-Hyong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.8 no.5
    • /
    • pp.1152-1158
    • /
    • 2007
  • Although various fast and simple, testing devices have been developed in many countries such as the U.S, Japan, and European countries, these testing devices are not commonly used in Korea. In this study, compaction fur the field density test was carried out with a hand-guided vibrating roller. The results of the field density test were compared with those of the new testing devices such as the geogauge, soil impact hammer(CASPFOL), light falling weight deflectometer(LFWD), dynamic cone penetration(DCP). Regression analyses were conducted with the data from new testing devices. The analysis results showed that the correlation coefficients were high in the range of $70{\sim}95%$.

  • PDF

Robust Tracking Control Based on Intelligent Sliding-Mode Model-Following Position Controllers for PMSM Servo Drives

  • El-Sousy Fayez F.M.
    • Journal of Power Electronics
    • /
    • v.7 no.2
    • /
    • pp.159-173
    • /
    • 2007
  • In this paper, an intelligent sliding-mode position controller (ISMC) for achieving favorable decoupling control and high precision position tracking performance of permanent-magnet synchronous motor (PMSM) servo drives is proposed. The intelligent position controller consists of a sliding-mode position controller (SMC) in the position feed-back loop in addition to an on-line trained fuzzy-neural-network model-following controller (FNNMFC) in the feedforward loop. The intelligent position controller combines the merits of the SMC with robust characteristics and the FNNMFC with on-line learning ability for periodic command tracking of a PMSM servo drive. The theoretical analyses of the sliding-mode position controller are described with a second order switching surface (PID) which is insensitive to parameter uncertainties and external load disturbances. To realize high dynamic performance in disturbance rejection and tracking characteristics, an on-line trained FNNMFC is proposed. The connective weights and membership functions of the FNNMFC are trained on-line according to the model-following error between the outputs of the reference model and the PMSM servo drive system. The FNNMFC generates an adaptive control signal which is added to the SMC output to attain robust model-following characteristics under different operating conditions regardless of parameter uncertainties and load disturbances. A computer simulation is developed to demonstrate the effectiveness of the proposed intelligent sliding mode position controller. The results confirm that the proposed ISMC grants robust performance and precise response to the reference model regardless of load disturbances and PMSM parameter uncertainties.

Super Multi-View 3-D Display System using Vibrating Scanner Array(ViSA)

  • Jeon, Ho-In;Jung, Nak-Hee;Choi, Jin-San;Kang, Yo-Seek;Choi, Se-Ha;Shin, Sang-Hun;Son, Jung-Yung
    • Journal of the Optical Society of Korea
    • /
    • v.4 no.1
    • /
    • pp.37-42
    • /
    • 2000
  • In this paper, we propose a super multi-view (SMV) 3-D display system using a vibrating scanner array (ViSA). The parallel beam scanning using a vibrating scanner array is performed by moving back and forth an array of curvature-compensated mirrors attached to two vibrating membranes. The parallel laser beam scanner array can replace the polygon mirror scanner which has been used in the SMV 3-D display system based on the focused light array(FLA) concept. The proposed system has great advantages in the sense that it requires neither huge imaging optics normechanical scanning parts. Some mathematical analyses and fundamental limitations of the proposed system are presented. The proposed vibrating scanner array, after some modifications and refinements, will replace polygon mirror-based scanners in the near future.

Metalorganic Chemical Vapor Deposition of $Ga_2O_3$ Thin Films Using Dimethylgallium Isopropoxide and $O_2$

  • U, Jeong-Jun;Park, Yeong-Su;Lee, Hui-Ju;Jeon, Du-Jin;Kim, Geon-Hui;Kim, Yun-Su
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.02a
    • /
    • pp.195-195
    • /
    • 2010
  • $Ga_2O_3$ thin films have been grown on Si(001) substrates by metalorganic chemical vapor deposition (MOCVD) using dimethylgallium isopropoxide ($Me_2GaO^iPr$, DMGIP) with oxygen as the reactant gas. Suitability of the precursor for CVD was confirmed by thermogravimetric analysis (TGA) and vapor pressure measurement. Deposition was carried out in the substrate temperature range $450-650^{\circ}C$. Spectroscopic ellipsometry, X-ray diffraction (XRD), and X-ray photoelectron spectroscopy (XPS) and Rutherford back-scattering spectroscopy (RBS) were used to determine the thickness, crystallinity, and composition and stoichiometry of the films, respectively. From the slope of the Arrhenius plot in the temperature range $500-550^{\circ}C$, the activation energy of deposition was found to be $225.5\;kJ\;mol^{-1}$. As-deposited films were amorphous, but the monoclinic $\beta-Ga_2O_3$ phase was revealed after annealing the films in air at $1050^{\circ}C$. The XPS and RBS analyses indicate that the $Ga_2O_3$ films obtained by using DMGIP were found to be almost stoichiometric.

  • PDF

A Study on the Inner Temperature Behaviors in the Casting Process for the Development of the Automatic Parts (자동차 부품 소재 개발에 따른 캐스팅 과정의 부품 내부온도 거동에 관한 연구)

  • Cha Young-Hoon;Sung Back-Sub;Jang Hoon;Kim Mi-Ai;Kim Jung-Dae;Kim Sun-Jun;Kim Duck-Joong;Lee Youn-Sin
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.10a
    • /
    • pp.279-284
    • /
    • 2005
  • The casting defects that are caused by molten metal were cold shut formation, entrapment of air, gas, and inclusion. But the control of casting defects has been based on the experience of the foundry engineers. In this thesis, the computer simulation analyzed the flow of molten metal. The quantitative analyses which proposed the effective mold design was executed Flow patterns of 0.15-0.16m/s molten metal in 15 mm thin plate casting were investigated in order to optimize die-casting process. As increasing ingate velocity in thin plate casting, cold shot was decreased. The parameters of runner shape that affected on the optimized conditions that was calculated with simple equation were investigated. These die casting process control techniques of automobile valve body mid-plate have achieved good agreement with the experimental data of tensile strength, hardness test, and material structure photographies satisfactory results.

  • PDF

Simulation on Energy Consumption in the Summer Season Operation of primary HVAC system for Multipurpose Building Complex (다목적 복합건물의 하절기 열원기기 운전시 소비전력에 관한 시뮬레이션)

  • Suh, Jae-Kyoung;Choi, Seung-Gil;Kang, Chae-Dong
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.903-908
    • /
    • 2006
  • Building energy simulation has become a useful tool for predicting cooling, heating and air-conditioning loads for facilities. It is important to provide building energy performances feed back to the mechanical and electrical system operator and engineer for energy conservation and maintenance of building. From this research, we set up the typical weather data of location, basic description of building, geometric modelling data and the specification of Installed primary HVAC system for establishing the simulation model about energy consuming that take place in multipurpose building complex. The simulation tool of building energy - EnergyPlus (DOE and BLAST based simulation S/W), it has been used and accomplished calculations and analyses for evaluating the effect of the system types and operating condition of central HVAC plant on the building energy consumption. In this paper, we offer comparison and simultaneous results those involve electricity consumption pattern and amount between actual operation versus EnergyPlus simulation to the object building during summer season.

  • PDF

Work-Family Conflict, Task Interruptions, and Influence at Work Predict Musculoskeletal Pain in Operating Room Nurses

  • Nutzi, Marina;Koch, Patricia;Baur, Heiner;Elfering, Achim
    • Safety and Health at Work
    • /
    • v.6 no.4
    • /
    • pp.329-337
    • /
    • 2015
  • Background: The aim of this study is to examine the prevalence of musculoskeletal complaints in Swiss operating room (OR) nurses, and to investigate how work-family conflict, work interruptions, and influence at work are related to lumbar and cervical back pain. Methods: Participants in this correlational questionnaire study included 116 OR nurses from eight different hospitals in Switzerland. Results: We found that 66% of the OR staff suffered from musculoskeletal problems. The most prevalent musculoskeletal complaints were lumbar (52.7%) and cervical pain (38.4%). Furthermore, 20.5% reported pain in the mid spine region, 20.5% in the knees and legs, and 9.8% in the hands and feet. Multiple linear regression analyses showed that work-family conflict (p < 0.05) and interruptions (p < 0.05) significantly predicted lumbar and cervical pain in OR nurses, while influence at work (p < 0.05) only predicted lumbar pain. Conclusion: These results suggest that reducing the work-family conflict and interruptions at work, as well as offering opportunities to influence one's workplace, help to promote OR nurses' health.

Previous Infection with Plasmodium berghei Confers Resistance to Toxoplasma gondii Infection in Mice

  • Lee, Dong-Hun;Chu, Ki-Back;Kang, Hae-Ji;Lee, Su-Hwa;Quan, Fu-Shi
    • Parasites, Hosts and Diseases
    • /
    • v.57 no.2
    • /
    • pp.93-99
    • /
    • 2019
  • Both Plasmodium spp. and Toxoplasma gondii are important apicomplexan parasites, which infect humans worldwide. Genetic analyses have revealed that 33% of amino acid sequences of inner membrane complex from the malaria parasite Plasmodium berghei is similar to that of Toxoplasma gondii. Inner membrane complex is known to be involved in cell invasion and replication. In this study, we investigated the resistance against T. gondii (ME49) infection induced by previously infected P. berghei (ANKA) in mice. Levels of T. gondii-specific IgG, IgG1, IgG2a, and IgG2b antibody responses, $CD4^+$ and $CD8^+$ T cell populations were found higher in the mice infected with P. berghei (ANKA) and challenged with T. gondii (ME49) compared to that in control mice infected with T. gondii alone (ME49). P. berghei (ANKA) + T. gondii (ME49) group showed significantly reduced the number and size of T. gondii (ME49) cysts in the brains of mice, resulting in lower body weight loss compared to ME49 control group. These results indicate that previous exposure to P. berghei (ANKA) induce resistance to subsequent T. gondii (ME49) infection.

The role of percutaneous neurolysis in lumbar disc herniation: systematic review and meta-analysis

  • Manchikanti, Laxmaiah;Knezevic, Emilija;Knezevic, Nebojsa Nick;Sanapati, Mahendra R.;Kaye, Alan D.;Thota, Srinivasa;Hirsch, Joshua A.
    • The Korean Journal of Pain
    • /
    • v.34 no.3
    • /
    • pp.346-368
    • /
    • 2021
  • Background: Recalcitrant disc herniation may result in chronic lumbar radiculopathy or sciatica. Fluoroscopically directed epidural injections and other conservative modalities may provide inadequate improvement in some patients. In these cases, percutaneous neurolysis with targeted delivery of medications is often the next step in pain management. Methods: An evidence-based system of methodologic assessment, namely, the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) was used. Multiple databases were searched from 1966 to January 2021. Principles of the best evidence synthesis were incorporated into qualitative evidence synthesis. The primary outcome measure was the proportion of patients with significant pain relief and functional improvement (≥ 50%). Duration of relief was categorized as short-term (< 6 months) and long-term (≥ 6 months). Results: This assessment identified one high-quality randomized controlled trial (RCT) and 5 moderate-quality non-randomized studies with an application of percutaneous neurolysis in disc herniation. Overall, the results were positive, with level II evidence. Conclusions: Based on the present systematic review, with one RCT and 5 non-randomized studies, the evidence level is II for percutaneous neurolysis in managing lumbar disc herniation.