• Title/Summary/Keyword: b 값

Search Result 5,378, Processing Time 0.032 seconds

Magnetic Resonance Imaging uses 3D Printed Material of Headset (Noise Reduction Effect) (자기공명영상 검사 시 3D 프린팅 재료를 이용한 헤드셋 연구 (소음저감 효과))

  • Choi, Woo Jeon;Kim, Dong Hyun
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.3
    • /
    • pp.335-341
    • /
    • 2018
  • With the improvement of medical state, patients' expectations for the most advanced medical equipment are increasing. Particularly, Magnetic Resonance Image (MRI) is used as one of the core image diagnosis methods in all clinical area. However, it has been reported that many of patients who go through the examination suffer from anxiety to the severe noise level during the examination. In this study, both the noise reduction evaluation of headsets with sound-blocking materials added to existing sound-absorbing materials and the existence of sound blocking materials as artifacts on the examination image are tested. An MRI test noise is recorded as a speaker by cross-ordination the sound material (sponge) and the sound material (acrylic plate, copper plate, and 3D copper plate) inside the headset made from 3D pring. A quantitative assessment of headsets showed that the average headset value was 81.8 dB. The average dB value of the most soundproof material combination(Copper, acrylic plate, sponge, sponge) headsets on headsets with added charactering material was measured at 70.4 dB, and MRI showed that the copper was diamagnetic substance and excluded. The second most soundproof headset(Sponge, acrylic plate, 3D copper plate, sponge) was measured at 70.6 dB and MRI showed no artifacts. The same simulation of the material printed with a 3D copper PLA containing approximately 40 % copper powder resulted in no artifacts, therefore, the material output as a 3D printing was better suited for use. For MRI related research, the mutual development of 3D printing is highly anticipated.

High quality volume visualization using B-spline interpolation (B 스플라인 보간을 이용한 고화질 볼륨 가시화)

  • Shin, Yongha;Kye, Heewon
    • Journal of the Korea Computer Graphics Society
    • /
    • v.22 no.3
    • /
    • pp.1-9
    • /
    • 2016
  • Linear interpolation is a basic sampling method for volume visualization. This method generates good images but sometimes it is inferior to our high expectation because it is encouraged to produce high quality images in the medical applications. In this paper, B spline based tri-cubic interpolation is used for the re-sampling step. The conventional B spline is an approximation method which does not cross control points so that we moved the control points and the curve crosses the original control points. In the rendering step, the empty space leaping is applicable to increase rendering speed. We have to calculate the maximum and minimum values for each block to detect empty space. The convex hull property of B spline enables the values of control points to be used as the maximum and minimum values. As a result, tri-cubic interpolated volume rendering is possible in interactive speed.

Comparison of models for sound propagation of low frequency wind turbine noise (풍력발전기의 저주파 소음 전파 모델 비교)

  • SungSoo Jung;Taeho Park;ByungKwon Lee;JinHyeong Kim;TaeMuk Choi
    • The Journal of the Acoustical Society of Korea
    • /
    • v.43 no.2
    • /
    • pp.162-167
    • /
    • 2024
  • Low frequency noise emitted by wind turbines is one of the most noise complaints. In this study, the reliability of the models was examined by comparing the measured sound pressure levels with the predicted levels based on Denish model and commercial programs of the SounPLAN and the ENPro based on ISO 9613. As a result of applying it to representative 3 MW wind turbines, on lnad, the measured and the predicted values differed within a maximum of 5 dB in the frequency range of 12.5 Hz to 80 Hz. It may be due to the change in the acoustic power levels because the wind turbines have been in operation for more than 7 years. However, considering that the Boundary Element Method (BEM) predicted value, which is known to be the most accurate in the low frequency band, the predicted values are well matched within 2.5 dB, the models of this study are expected to be used as deviation within 3 dB.

Measurement and evaluation of speech privacy in university office rooms (대학 내 사무실의 스피치 프라이버시 측정 및 평가)

  • Lim, Jae-Seop;Choi, Young-Ji
    • The Journal of the Acoustical Society of Korea
    • /
    • v.38 no.4
    • /
    • pp.396-405
    • /
    • 2019
  • The speech privacy of closed office rooms located in a university campus was measured and assessed in terms of SPC (Speech Privacy Class) values. The measurements of two quantities, the LD (Level Difference) between a source and a receiving room, and the background noise level ($L_b$) at the receiving room were carried out in 5 rooms located in 3 different buildings in the university campus. Each of the 5 rooms was adjacent to both offices and corridors through walls. The TL (Transmission Loss) between the source and the receiver room was also measured to compare the difference of two standard methods, ASTM E2836-10 and KS F 2809. The present results show that the speech privacy of the 5 office rooms is not met the requirement for a minimum SPC values of 70. A minimum LD value of 41 dB between the source and the receiver room should be achieved for having a SPC value of 70 when the mean measured value of $L_b$ at the receiving room is 29.2 dB. That is, the TL(avg) value averaged over the octave bands from 160 Hz to 5000 Hz between the source and the receiver room should be or greater than 40 dB. The most important architectural factor influencing the LD value is the presence of openings, such as doors, and windows, on the adjacent walls between the source and receiving room. Therefore, if the opening of the adjacent wall is replaced by an opening with high sound insulation, the appropriate SPC value of the research and office rooms can be achieved.

Color lens CIE L*a*b* coordination transfer by tinted time (착색시간에 따른 칼라렌즈 색좌표 이동)

  • Jeong, Byung-Mann;Park, Kwang-Ho;Kim, Yong-Geun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.8 no.1
    • /
    • pp.53-57
    • /
    • 2003
  • R, G, Y, B color lenses Manufactured increasing tinted time by 5 min term. CIE $L^*a^*b^*$ coordination's analysis used spectrophotometer and CIE $L^*a^*b^*$ color system. CIE $L^*a^*b^*$ coordination transfer form about tinted time being $$b^*(Y-B)={\beta}a^*+{\alpha}$$ change to do linear almost. In red case, move in $G{\rightarrow}R$, $B{\rightarrow}Y$ form tinted time increases, and Parameter ${\alpha}$, ${\beta}$ value got each -3.49 and 0.90. In green case, CIE $L^*a^*b^*$ coordination transfer form is $R{\rightarrow}G$, $B{\rightarrow}Y$ form. Got the pure green color color in 10 min's tinted time. Parameter ${\alpha}$, ${\beta}$ value got each -0.72 and -0.55. Get into pure yellow and blue color case tinted time increases. Parameter ${\alpha}$, ${\beta}$ value are 14.11 and 1.58 in yellow, and Parameter ${\alpha}$, ${\beta}$ value are -11.62 and 1.30 in blue color.

  • PDF

Adaptive Enhancement Algorithm of Perceptual Filter Using Variable Threshold (가변 임계값을 이용한 지각 필터의 적응적인 음질 개선 알고리즘)

  • 차형태
    • The Journal of the Acoustical Society of Korea
    • /
    • v.23 no.6
    • /
    • pp.446-453
    • /
    • 2004
  • In this paper, a new adaptive perceptual filter using variable threshold to enhance audio signals degraded by additively nonstationary noise is proposed. The adaptive perceptual filter updates variable threshold each time according to the power of signal and the effect of noise variation. So the noisy audio signal is enhanced by the method which controls a residual noise effectively. The proposed algorithm uses the perceptual filter which transforms a time domain signal into frequency domain and calculates an intensity energy and an excitation energy in bark domain. In this method. the stage updated the response of filter is decided by threshold. The proposed algorithm using vairable threshold effectively controls a residual noise using the energy difference of audio signals degraded by the additive nonstationary noise. The proposed method is tested with the noisy audio signals degraded by nonstationary noise at various signal -to-noise ratios (SNR). We carry out NMR and MOS test when the input SNR is 15dB. 20dB. 25dB and 30dB. An approximate improvement of 17.4dB. 15.3dB, 12.8dB. 9.8dB in NMR and enhancement of 2.9, 2.5, 2.3, 1.7 in MOS test is achieved with the input signals. respectively.

Compressive Strength of Unidirectional Glass/Epoxy Specimens Processed by Wet Lay-up at Room Temperature (수작업/상온경화시킨 일방향 Glass/Epoxy 시편의 압축강도)

  • Lee, Jong-Won;Kim, Jin-Won
    • Aerospace Engineering and Technology
    • /
    • v.6 no.1
    • /
    • pp.1-6
    • /
    • 2007
  • The present study provides the compressive design allowable of a unidirectional glass/epoxy composite laminate processed by wet lay-up at room temperature. The compressive strength values measured from 39 specimens have been assumed to follow the two-parameter Weibull distribution. Following the statistical guidelines provided by MIL-HDBK-17F, the B-basis and A-basis values of the aforementioned laminate are found to be 82.6% and 65.9%, of the mean compressive strength, respectively. The B-basis value is then discounted further at 50% for the in-situ application on the main wing spar caps of an experimental canard aircraft.

  • PDF

채널상태정보를 이용한 OFDM-단축블륵터보코드의 성능 분석

  • Kim, Han-Jong
    • Proceedings of the Korean Society Of Semiconductor Equipment Technology
    • /
    • 2007.06a
    • /
    • pp.254-258
    • /
    • 2007
  • 본 논문에서는 OFDM 변조와 단축블록터보코드를 사용하는 시스템에서 단축블록터보코드를 반복 복호하는 과정에서 채널상태정보(Channel State Information : CSI)값을 적용한 방법을 새롭게 제안하였다. 새롭게 제안된 시스템의 경우 1회의 같은 반복 횟수를 가지는 경우에 BER 성능이 신호의 변조방식에 따라 4.5[dB] $\sim$ 10.0[dB] 정도의 뛰어난 전능 향상을 보였다. 또한 CSI값을 적용하고 1회 반복 복호한 시스템이 CSI값을 적용하지 않은 기존의 복호 시스템의 4회 반복 복호한 경우보다도 1[dB] $\sim$ 7.0[dB]의 성능 향상을 보임으로써 반복 복호의 시간을 70[%] 이상 감소시킬 수 있다. 따라서 단축블록터보코드를 반복 복호하는 경우에 CSI값을 적용한 시스템이 뛰어난 성능 향상과 더불어 반복 복호 시간을 줄임을 알 수 있었다.

  • PDF

Effects of $Bi_2$$O_3$ additions on the dielectric and piezoelectric properties in Pb($Zr_{0.54}$, $Ti_{0.46}$)$O_3$ ($Bi_2$$O_3$첨가량이 Pb($Zr_{0.54}$, $Ti_{0.46}$)$O_3$의 유전, 압전특성에 미치는 영향)

  • 배이열;서동수
    • Electrical & Electronic Materials
    • /
    • v.6 no.3
    • /
    • pp.207-213
    • /
    • 1993
  • Pb(Z $r_{0.54}$, $Ti_{0.46}$) $O_{3}$에 B $i_{2}$ $O_{3}$를 0.0wt%까지 첨가하여 미세구조, 유전, 압전, 성질에 미치는 영향을 고찰하였다. B $i_{2}$ $O_{3}$의 고용범위는 약 0.5~0.7wt%정도 이었고 B $i_{2}$ $O_{3}$ 첨가량이 증가함에 따라서 결정립의 크기가 감소하였다. B $i_{2}$ $O_{3}$첨가량이 증가함에 따라 고용한계까지는 $d_{33}$ , tan .delta., .xi.$_{r}$(분극후)값이 증가하였으며 Qm값과 밀도는 감소하였다. $K_{p}$ 값은 B $i^{3+}$ 가 P $b^{2+}$를 치환하므로 형성되는 Pb공공의 형성에 의해 자발분극이 증가됨에 따라 증가하였다.다.

  • PDF

A Study on the Partial Path Loss Model By Using the Free Space and Rata Path Loss Model (자유 공간 모델과 하타 모델을 이용한 구간별 경로 손실 모델 설정에 관한 연구)

  • Park, Kyung-Tae;Cho, Hyung-Rae
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.12 no.3
    • /
    • pp.194-198
    • /
    • 2011
  • In this paper, we obtained the path loss characteristics in the 850 MHz for Russia area by using the free space path loss model and Okumura-Hata path loss model. In order to extract the additional path loss model parameter from the new Russian regional properties, the mean square error technique is used to obtain the correction factor. According to the obtained correction factor, the differences for the free space and Hata path loss model are 17, 6 dB in the 5 ~ 10 Km, 28, 14 dB in the 10 ~ 15 Km, and 35, 18 dB in the 15 ~ 20 Km. By applying the correction factors, the appropriate partial path loss models for the measured Russain area are proposed.