• 제목/요약/키워드: axial load effect

검색결과 541건 처리시간 0.023초

적층고무베어링과 납-고무베어링의 내진 성능에 관한 실험적 평가 (Experimental Evaluation of Seismic Performance of Laminated Elastomeric Bearing and Lead-Rubber Bearing)

  • 김대곤;이상훈;김대영;박칠림
    • 한국지진공학회논문집
    • /
    • 제2권4호
    • /
    • pp.53-62
    • /
    • 1998
  • 구조물의 내진 성능 향상을 위해 현재 종종 사용되어지고 있는 기초분리장치인 적층고베어링과 납-고무 베어링의 내진성능을 실험적으로 파악하였다 베어링의 전단 변형률 또는 가해진 수직 하중이 클수록 베어링의 전단 강성은 감소하며 가력 속도에 대한 영향을 무시할 만하다. 베어링은 순수압축력에는 강하며 인장력에는 그 반대이다.

  • PDF

Analysis of concrete-filled steel tubular columns with "T" shaped cross section (CFTTS)

  • Wang, Qin-Ting;Chang, Xu
    • Steel and Composite Structures
    • /
    • 제15권1호
    • /
    • pp.41-55
    • /
    • 2013
  • This paper presents a numerical study of axially loaded concrete-filled steel tubular columns with "T" shaped cross section (CFTTS) based on the ABAQUS standard solver. Two types of columns with "T" shaped cross section, the common concrete-filled steel tubular columns with "T" shaped cross section (CCFTTS) and the double concrete-filled steel tubular columns with "T" shaped cross section (DCFTTS), are discussed. The failure modes, confining effects and load-displacement curves are analyzed. The numerical results indicate that both have the similar failure mode that the steel tubes are only outward buckling on all columns' faces. It is found that DCFTTS columns have higher axial capacities than CCFTTS ones duo to the steel tube of DCFTTS columns can plays more significant confining effect on concrete. A parametric study, including influence of tube thickness, concrete strength and friction coefficient of tube-concrete interface on the axial capacities is also carried out. Simplified formulae were also proposed based on this study.

수치해석을 이용한 SHPB 시험의 마찰영향 분석 (An Investigation into the effect of friction in the split hopkinson pressure bar (SHPB) test by numerical experiments)

  • 차성훈;신명수;신현호;김종봉
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회A
    • /
    • pp.204-209
    • /
    • 2008
  • The interest in the mechanical behavior of materials at high strain rates has increased in recent years, and by now it is well known that mechanical properties can be strongly influenced by the speed of applied load. The split Hopkinson pressure bar (SHPB) has been widely used to determine mechanical properties of materials at high loading rates. However, to ensure test reliability, measurement error source must be accounted for and eliminated. During experiment, the specimens were located between the incident and the transmit bar. The presence of contact frictions between the test bars and specimen may cause errors. In this work, numerical experiments were carried out to investigate the effect of friction on test results. In SHPB test, the measured stress by the transmitted bar is assumed to be flow stress of the test specimen. Through the numerical experiments, however, it is shown that the measured stress by the transmit bar is axial stress components. When, the contact surface is frictionless, the flow stress and the axial stress of the specimen are about the same. When the contact surface is not frictionless, however, the flow stress and the axial stress are not the same anymore. Therefore, the measured stress by the transmitted bar is not flow stress. The effect of friction on the difference between flow stress and axial stress is investigated.

  • PDF

Effect of spiral spacing on axial compressive behavior of square reinforced concrete filled steel tube (RCFST) columns

  • Qiao, Qiyun;Zhang, Wenwen;Mou, Ben;Cao, Wanlin
    • Steel and Composite Structures
    • /
    • 제31권6호
    • /
    • pp.559-573
    • /
    • 2019
  • Spiral spacing effect on axial compressive behavior of reinforced concrete filled steel tube (RCFST) stub column is experimentally investigated in this paper. A total of twenty specimens including sixteen square RCFST columns and four benchmarked conventional square concrete filled steel tube (CFST) columns are fabricated and tested. Test variables include spiral spacing (spiral ratio) and concrete strength. The failure modes, load versus displacement curves, compressive rigidity, axial compressive strength, and ductility of the specimens are obtained and analyzed. Especially, the effect of spiral spacing on axial compressive strength and ductility is investigated and discussed in detail. Test results show that heavily arranged spirals considerably increase the ultimate compressive strength but lightly arranged spirals have no obvious effect on the ultimate strength. In practical design, the effect of spirals on RCFST column strength should be considered only when spirals are heavily arranged. Spiral spacing has a considerable effect on increasing the post-peak ductility of RCFST columns. Decreasing of the spiral spacing considerably increases the post-peak ductility of the RCFSTs. When the concrete strength increases, ultimate strength increases but the ductility decreases, due to the brittleness of the higher strength concrete. Arranging spirals, even with a rather small amount of spirals, is an economical and easy solution for improving the ductility of RCFST columns with high-strength concrete. Ultimate compressive strengths of the columns are calculated according to the codes EC4 (2004), GB 50936 (2014), AIJ (2008), and ACI 318 (2014). The ultimate strength of RCFST stub columns can be most precisely evaluated using standard GB 50936 (2014) considering the effect of spiral confinement on core concrete.

Effect of flexure-extension coupling on the elastic instability of a composite laminate plate

  • H. Mataich;A. El Amrani;J. El Mekkaoui;B. El Amrani
    • Structural Engineering and Mechanics
    • /
    • 제90권4호
    • /
    • pp.391-401
    • /
    • 2024
  • The present study focuses on the effect of extension-bending coupling on the elastic stability (buckling) of laminated composite plates. These plates will be loaded under uni-axial or bi-axial in-plane mechanical loads, especially in the orthotropic or anti-symmetric cross-angle cases. The main objective is to find a limit where we can approximate the elastic stability behavior of angularly crossed anti-symmetric plates by the simple behavior of specially orthotropic plates. The contribution of my present study is to predict the explicit effect of extension-flexion coupling on the elastic stability of this type of panel. Critically, a parametric study is carried out, involving the search for the critical buckling load as a function of deformation mode, aspect ratio, plate anisotropy ratio and finally the study of the effect of lamination angle and number of layers on the contribution of extension-flexure coupling in terms of plate buckling stability. We use first-order shear deformation theory (FSDT) with a correction factor of 5/6. Simply supported conditions along the four boundaries are adopted where we can develop closed-form analytical solutions obtained by a Navier development.

적설하중이 작용하는 비닐하우스 골조에 대한 강선보강효과 (Effect of Wire Bracing to Snow Load Acting on Vinyl House Frame)

  • 정동조;탱차이
    • 한국농촌건축학회논문집
    • /
    • 제12권3호
    • /
    • pp.27-34
    • /
    • 2010
  • Unbraced vinyl house frame that is economically installed is certainly easy to collapse under the influence of excess snow load. To make it more cheaply in putting up as well as more efficiently in withstanding the applied snow load, it is essential to insert additional bracing into the existing unbraced vinyl house frame. On the other hand, there are varieties of possible bracing shapes that can be formed. However, their efficiencies are different. Therefore, it is important to identify the most effective bracing shape. In this study, 2 different kinds of bracing shapes, horizontal and inclined bracing, are used to additionally install in the ordinary single frames in order to show the effect of the bracing resisting the applied snow load and compare the bending moment, axial force, combined stress and vertical displacement of the vinyl house frame.

Effect of loading rate on mechanical behavior of SRC shearwalls

  • Esaki, Fumiya;Ono, Masayuki
    • Steel and Composite Structures
    • /
    • 제1권2호
    • /
    • pp.201-212
    • /
    • 2001
  • In order to investigate the effect of the loading rate on the mechanical behavior of SRC shearwalls, we conducted the lateral loading tests on the 1/3 scale model shearwalls whose edge columns were reinforced by H-shaped steel. The specimens were subjected to the reversed cyclic lateral load under a variable axial load. The two types of loading rate, 0.01 cm/sec for the static loading and 1 cm/sec for the dynamic loading were adopted. The failure mode in all specimens was the sliding shear of the in-filled wall panel. The edge columns did not fail in shear. The initial lateral stiffness and lateral load carrying capacity of the shearwalls subjected to the dynamic loading were about 10% larger than those subjected to the static loading. The effects of the arrangement of the H-shaped steel on the lateral load carrying capacity and the lateral load-displacement hysteresis response were not significant.

아치작용을 고려한 PSC보의 복부전단거동 (Shear Behavior of Web Element in PSC Beams Incorporated with Arch Action)

  • 정제평;신근옥;김우
    • 대한토목학회논문집
    • /
    • 제35권1호
    • /
    • pp.85-92
    • /
    • 2015
  • 횡방향 철근이 없는 RC와 PSC 보에서 축방향 인장력은 전단강도를 감소시키고, 축압축력은 전단저항력을 증가시킨다는 것은 잘 알려진 사실이다. 그러나 축력이 전단에 얼마만큼 영향을 미치고, 전단 저항성능에 어떠한 영향을 주는가에 대한 이해가 부족한 현실이다. 횡방향 보강철근이 없는 부재가 큰 압축력과 전단력을 받으면 첫 번째 경사균열이 일어나면서 그대로 취성파괴가 발생하기 때문에 상당히 보수적 관점을 유지하고 있다. 이런 배경에서 ACI의 복부전단강도는 경사균열각 ${\theta}$$45^{\circ}$로 하는 트러스모델을 사용하여 스터럽의 수직력과 축력효과를 반영하고 있다. 본 연구는 파괴역학을 근간으로 한 비선형 유한요소해석 프로그램 ATENA-2D (Cervenka, 2000)를 사용하여 철근콘크리트 보의 축력작용에 따른 검증을 수행한 것이다.

변형률 속도를 고려한 원형 튜브의 동적 좌굴 현상의 상계 해석에 관한 연구 (Upper Bound Analysis of Dynamic Buckling Phenomenon of Circular Tubes Considering Strain Rate Effect)

  • 박충희;고윤기;허훈
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회A
    • /
    • pp.711-716
    • /
    • 2008
  • A circular tube undergoes bucking behavior when it is subjected to axial loading. An upper bound analysis can be an attractive approach to predict the buckling load and energy absorption efficiently. The upper bound analysis obtains the load or energy absorption by means of assumption of the kinematically admissible velocity fields. In order to obtain an accurate solution, kinematically admissible velocity fields should be defined by considering many factors such as geometrical parameters, dynamic effect, etc. In this study, experiments and finite element analyses are carried out for circular tubes with various dimensions and loading conditions. As a result, the kinematically admissible velocity field is newly proposed in order to consider various dimensions and the strain rate effect of material. The upper bound analysis with the suggested velocity field accurately estimates the mean load and energy absorption obtained from results of experiment and finite element analysis.

  • PDF

강사장교 거더와 주탑에 하중저항계수설계법의 보-기둥 상관식을 사용한 내하율 산정식 적용 (Application of Proposed Rating Equations using LRFD Beam-Column Interaction Equations for Girders and Towers in Steel Cable-Stayed Bridges)

  • 최동호;유훈;이범수;조선규
    • 한국강구조학회 논문집
    • /
    • 제19권1호
    • /
    • pp.1-13
    • /
    • 2007
  • 강사장교의 거더와 주탑은 축력과 모멘트를 동시에 받는 보-기둥 부재이기 때문에 단일 힘을 고려하는 일반도로교의 내하율 산정식은 강사장교의 거더와 주탑에 적용할 수 없다. 현재, 사장교의 거더와 주탑에 적용 가능한 이론적인 내하율 산정방법은 아직 정립되지 않았다. 본 논문에서는 축력과 모멘트를 동시에 받는 부재의 상관공식을 적용하여 강사장교 거더와 주탑의 내하율을 산정하기 위한 식을 제안하였다. 영향선해석을 수행하여 각 부재에 압축력 최대, 정 및 부모멘트 최대의 경우에 활하중 재하 형태를 결정하였고 각 부재의 내하율 산정절차를 정리하였다. 제안된 내하율 산정방법의 타당성을 검증하기 위하여 실교량 모델인 돌산대교에 대한 적용예를 제시하였다. 일반도로교의 내하율 산정식은 돌산대교 거더와 주탑의 내하율을 과대평가 하였으며, 제안된 내하율 산정식은 축력과 모멘트를 동시에 지지하는 사장교 거더와 주탑의 거동을 적절히 반영하였다.