• Title/Summary/Keyword: axial distance

Search Result 315, Processing Time 0.051 seconds

A Study on the axial force in CWR with Turnout according to Distance between Bridge Expansion Joint and Turnout (교량신축과 분기기의 이격거리에 따른 교량상 분기기 축력특성 연구)

  • Choi, Jin-Yu;Lee, Hyun-Jeong;Yang, Shin-Chu;Jeong, Jang-Yong;Yu, Jin-Young
    • Proceedings of the KSR Conference
    • /
    • 2008.11b
    • /
    • pp.1050-1055
    • /
    • 2008
  • The demand on a turnout layed on a bridge is rising owing to the increasing number of stations on the viaduct. And also the demand on a turnout with CWR is rising to upgrade running speed of the passing train. A CWR with turnout is subjected to additional axial force induced by the thermal expansion of bridge as well as lead rail of turnout. The additional axial force is closely related with the distance between bridge expansion joint and turnout when it is located near the movable bearing of bridge, and it is required to keep some distance to prevent excessive axial stress in CWR. But, there is no guideline in specification for the proper distance from E.J. to turnout, and it caused problem in planning turnout or bridge. So, it this study, the parametric study to investigate the effect on axial stress in CWR with turnout according to span length and distance between bridge expansion joint and turnout was performed. From the results of numerical analysis, it was found out that $5{\sim}30m$ distance is required to prevent excessive axial in CWR for span length less 90m.

  • PDF

A Study of the Characteristics on the Vacuum Interrupter with Axial Magnetic Field Type using 3 Dimension Finite Element Analysis (3차원 유한요소해석을 이용한 종자게형 진공 인터럽터의 특성고찰)

  • 하덕용;강형부
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.15 no.5
    • /
    • pp.460-467
    • /
    • 2002
  • This paper deals with the distribution characteristics of the current density and axial magnetic flux density on the vacuum interrupter with axial magnetic field type using 3 dimension finite element analysis. An axial magnetic field parallel to the current flow in the arc column can improve the current breaking capacity of vacuum interrupter by affecting the arc mode. The axial magnetic flux density on the contact electrode surface is analyzed by inputting external current as a function of the transient time for sine half wave. And it also is analyzed within the gap distance of the contact electrode. The peak value of current but is decreased with the descending current on the contact electrode surface and within the gap distance of the contact electrode. The residual magnetic field is generated on the contact electrode surface and within the gap distance in the instant of zero current, which is due to the influence of eddy currents. The phase shift due to eddy currents, defined as time difference between the maximum value of current and axial magnetic field, is about 1ms in the center point of gap distance.

Influence of Blade Row Distance on Performance and Flow Condition of Contra-Rotating Small-Sized Axial Fan

  • Shigemitsu, Toru;Fukutomi, Junichiro;Shimizu, Hiroki
    • International Journal of Fluid Machinery and Systems
    • /
    • v.5 no.4
    • /
    • pp.161-167
    • /
    • 2012
  • Small-sized axial fans are used as air coolers for electric equipment. There is a strong demand for higher power of fans according to the increase of quantity of heat from electric devices. Therefore, higher rotational speed design is conducted, although, it causes the deterioration of the efficiency and the increase of noise. Then, the adoption of contra-rotating rotors for small-sized fans is proposed for the improvement of the performance. In the case of contra-rotating rotors, blade row distance between the front and the rear rotors influences on the performance and the noise. Therefore, it is important to clarify the optimum blade row distance between front and rear rotors. The performance curves of the contra-rotating small-sized axial fan under the condition of different blade row distances are shown and the blade row interaction between the front and the rear rotors are discussed by the numerical results. Furthermore, the optimum blade row distance of the contra-rotating small-sized axial fan is considered.

Analysis of Axial Distance Between Driving and Driven Pulley of a Motorcycle CVT (이륜차 무단변속장치의 구동풀리와 종동풀리의 축간거리 해석)

  • 김규성;권영웅
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.12 no.2
    • /
    • pp.59-64
    • /
    • 2003
  • Continuously Variable Transmission (CVT) consists of a driving pulley and a driven pulley joined by rubber V-belt. Each pulley consists of a fixed flange and a movable flange. The main advantages of the U with V-belt, which has been Popular in Asia, are a simple mechanism less maintenance and low cost. One of the important factors which have an influence on the performance of the CVT is change of axial distance. Base on an experiment the effects of transfer torque and speed ratio of both driving pulley and driven pulley during the alteration of axial distance were studied.

A Study on the Effect of the Contact Electrode Slits in the Vacuum Interrupter with Axial Magnetic Field Type (종자계형 진공 인터럽터에서 접점전극 슬릿의 영향에 관한 연구)

  • 하덕용;강형부;최승길;최경호
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.15 no.9
    • /
    • pp.822-829
    • /
    • 2002
  • This paper deals with the distribution characteristics of the current density and axial magnetic flux density for each slits made on the contact electrode in the vacuum interrupter with axial magnetic field type using 3-dimension finite element analysis. It has been known that the presence of an axial magnetic field parallel to the current flow in the arc plasma can increase the high current breaking capacity of vacuum interrupter by carrying out the arc plasma from constricted mode to diffusion mode. The axial magnetic field is created of itself by current flow in the segments of coil electrode behind the contact electrode. The analyzed results show that if the slits are made in the contact electrode, they can increase the current density and axial magnetic flux density in the contact electrode surface and at the gap distance, which is due to decrease the effect of eddy currents flowing in the contact electrode. The phase shift due to eddy currents, defined 3s time difference between the maximum value of current and axial magnetic field, is decreased still more by increasing the number of slits made in the contact electrode at the center point of gap distance. These results demonstrate that 3-dimension finite element analysis has a great deal of merits in the development and evaluation of new electrode at the design of vacuum interrupter.

An Experimental Study on the Characteristics of Twin Spray Ejected from Two Swirl Spray Nozzles (두개의 와류분무 노즐로부터 분사되는 이중분무의 분무특성에 관한 실험적 연구)

  • 김인구;이상룡
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.12 no.2
    • /
    • pp.359-372
    • /
    • 1988
  • Characteristics of twin spray ejected from two swirl spray nozzles were studied experimentally. By using a patternator for measuring volumetric flux of drop flow at various locations inside the spray, variation of the twin spray pattern along the axial direction was studied with changing the injection pressure and the distance between the nozzles. The general findings from the experiments are as follows: (i) as axial distance from the nozzles increases, the spray pattern in x-z plane which contains both nozzles changes significantly. On the other hand the spray pattern in y-z plane which passes the midpoint between two nozzles remains almost unchanged at outer region as axial distance and injection pressure vary; (ii) at the downstream of the twin spray with spray interaction, the maximum volumetric flux in y-z plane (q$_{max}$)$_{y}$, has tendency to become larger than that of x-z plane (q$_{max}$)$_{x}$, due to a characteristic(hollow cone shape) of the constituting swirl sprays, and this trend is pronounced at higher injection pressure since the cross-section of each single spray remains hollow at the longer axial distance from each nozzle with higher injection pressure; (iii) at a certain axial distance from the nozzles, the cross-sectional shape of the boundary of the twin spray tends to be circular similar to that of the single spray with twice the flow-rate, and that distance is not proportional to the distance between two nozzles; (iv) though there are some collisions between droplets from each nozzles of twin spray, in present experimental range, the flow pattern of gas including the entrainment effect plays the key role in spray interaction.n.ion.n.

Waveform characterization and energy dissipation of stress wave in sandstone based on modified SHPB tests

  • Cheng, Yun;Song, Zhanping;Jin, Jiefang;Wang, Tong;Yang, Tengtian
    • Geomechanics and Engineering
    • /
    • v.22 no.2
    • /
    • pp.187-196
    • /
    • 2020
  • The changeable stress environment directly affect the propagation law of a stress wave. Stress wave propagation tests in sandstone with different axial stresses were carried using a modified split Hopkinson Pressure bar (SHPB) assuming the sandstone has a uniform pore distribution. Then the waveform and stress wave energy dissipation were analyzed. The results show that the stress wave exhibits the double peak phenomenon. With increasing axial stress, the intensity difference decreases exponentially and experiences first a dramatic decrease and then gentle development. The demarcation stress is σ/σc=30%, indicating that the closer to the incident end, the faster the intensity difference attenuates. Under the same axial stress, the intensity difference decreases linearly with propagation distance and its attenuation intensity factor displays a quadratic function with axial stress. With increasing propagation distance, the time difference decays linearly and its delay coefficient reflects the damage degree. The stress wave energy attenuates exponentially with propagation distance, and the relations between attenuation rate, attenuation coefficient and axial stress can be represented by the quadratic function.

A Study on the Three-Dimensional Turbulent Flour Characteristics of a Small-sized Axial Fan at the Maximum Flowrate Region (최대유량역에서 소형 축류 홴의 3차원 난류유동 특성에 관한 연구)

  • Kim, J.K.
    • Journal of Power System Engineering
    • /
    • v.4 no.3
    • /
    • pp.25-33
    • /
    • 2000
  • This study represents three-dimensional turbulent flow characteristics around an axial fan measured at the operating point ${\varphi}=0.32$, which is equivalent to the maximum flowrate region, by using three-dimensional fiber-optic type LDA system. This LDA system is composed of a 5 W Argon-ion laser, two optics in back-scatter mode, three BSA's, a PC, and a three-dimensional automatic traversing system. A kind of paraffin fog is used for laser particles in this study. Mean velocity profiles around an axial fan along the downstream radial distance show that the streamwise and the tangential components exist as a predominant velocity and have the maximum value at the radial distance ratio 0.8, while the radial component has a small scale distribution and its flow direction is inward except a part of blade tip. The turbulent intensity profiles show that the radial component exists the most greatly. And also the turbulent kinetic energy shows about 60% as a maximum value at the radial distance ratio 0.9. Moreover, the Reynolds shear stresses do not exist at upstream flow, but the streamwise and the radial components of them show about 20% as a maximum value at the radial distance ratio 0.9 at downstream flow.

  • PDF

3-D CT EVALUATION OF CONDYLE HEAD POSITION, MANDIBULAR WIDTH, AND MANDIBULAR ANGLE AFTER MANDIBULAR SETBACK SURGERY (3-D CT를 이용한 악교정수술후의 하악 과두 위치와 하악폭경 및 하악각의 평가)

  • Kim, Jae-Won;Lee, Dong-Hyun;Lee, Su-Youn;Kim, Jae-Hyun;Lee, Sang-Han
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.35 no.4
    • /
    • pp.229-239
    • /
    • 2009
  • The purpose of this study is to evaluate the change in condylar position, width, and angle before and after orthognathic surgery using 3-dimensional computed tomograph. Pre and posterative 3-D CT was taken on 38 patients and through axial, frontal, sagittal measurements and by 3-dimensional reconstruction, the changes in condylar postion, mandibular width and angle were analyzed and others such as the difference in gender, operation and fixation method, setback length and in relation with temporomandibular disorders were done together too. The results were as follows: The inward rotation of condyle in axial condylar angle, the forward movement of right condyle in sagittal anterior-posterior distance, the superior movement of both condyles in sagittal superior-inferior distance, the decrease in gonial angle, the increase in mandibular width, the decrease in distance between the axial coronoid process distance and the increase in the frontal intercondylar distance were statistically significant. There were no statistically significant changes in gender difference, however in the difference in operation method, change in the gonial angle was observed and there was more change in bilateral sagittal split osteotomy group compared to two-jaw surgery group. In the difference in fixation method, the decrease in axial coronoid process distance and the change in sagittal anterior-posterior distance were statistically significant. In the difference in setback, the increase in setback didn't relate directly with the increased change in condyle position. In the relation with temporomandibular disorder, changes in left axial condylar angle and axial coronoid process distance were statistically significant. Changes in condylar position could be observed after the orthognathic surgery but it doesn't seem to have much of a clinical importance. The orthognathic surgery is effective in decreasing the mandibular angle, and it is not related with the temporomandibular disorder.

A Study on Steady and Unsteady Behavior of Helium Jet in the Stationary Atmosphere (헬륨 기체분류의 정상적 비정상적 거동에 관한 연구)

  • Kim, B.G.;Suh, Y.K.;Ha, J.Y.;Kwon, S.S.
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.1 no.3
    • /
    • pp.34-45
    • /
    • 1993
  • This study aims to analyze the mixing characteristics of hydrogen considered as a new fuel for internal combustion engines. As the physical property of helium gas is similar to that of hydrogen, helium gas was used in this study. To analyze the steady and unsteady behavior of jet, helium gas was injected into the stationary atmosphere at the normal temperature and pressure. Concentration of helium gas in the center of jet flow is in inverse proportion with axial distance from the nozzle tip. This agrees with the free jet theory of Schlichting. The relative equation for dimensionless concentration to radial/axial distance the axial distance of potential core region, the cone angle a of the jet flow and the relative equation for arriving distance of the front of jet flow to the lapse of time are obtained. But free jet theory of Schlichting in the dimensionless concentration is not in agreement with the present experimental results of the distance of the radial direction. It needs more study. When the arrival frequency of jet flow is used as a parameter, the transition area changing from unsteady flow area into steady flow area becomes gradually wider downstream, but its ratio for the whole unsteady flow area gradually decreases.

  • PDF