• 제목/요약/키워드: axial direction

검색결과 899건 처리시간 0.024초

Prevalence and features of distolingual roots in mandibular molars analyzed by cone-beam computed tomography

  • Choi, Mi-Ree;Moon, Young-Mi;Seo, Min-Seock
    • Imaging Science in Dentistry
    • /
    • 제45권4호
    • /
    • pp.221-226
    • /
    • 2015
  • Purpose: This study evaluated the prevalence of distolingual roots in mandibular molars among Koreans, the root canal system associated with distolingual roots, and the concurrent appearance of a distolingual root in the mandibular first molar and a C-shaped canal in the mandibular second molar. Materials and Methods: Cone-beam computed tomographic images of 264 patients were screened and examined. Axial sections of 1056 mandibular molars were evaluated to determine the number of roots. The interorifice distances from the distolingual canal to the distobuccal canal were also estimated. Using an image analysis program, the root canal curvature was calculated. Pearson's chi-square test, the paired t-test, one-way analysis of variance, and post-hoc analysis were performed. Results: Distolingual roots were observed in 26.1% of the subjects. In cases where a distolingual root was observed in the mandibular molar, a significant difference was observed in the root canal curvature between the buccolingual and mesiodistal orientations. The maximum root canal curvature was most commonly observed in the mesiodistal orientation in the coronal portion, but in the apical portion, maximum root canal curvature was most often observed in the buccolingual orientation. Conclusion: The canal curvature of distolingual roots was found to be very complex, with a different direction in each portion. No correlation was found between the presence of a distolingual root in the mandibular first molar and the presence of a C-shaped canal in the mandibular second molar.

치과용 콘빔 CT영상에서 총의치 장착 후 하악과두의 위치변화 (Positional change of the condylar heads after wearing complete denture on dental cone beam CT)

  • 이봉호;김재덕;정재헌
    • Imaging Science in Dentistry
    • /
    • 제38권1호
    • /
    • pp.23-27
    • /
    • 2008
  • Purpose: The aim of this study was to evaluate the change in the position of the mandibular condyle within articular fossa by a CBCT after wearing complete denture (CD). Materials and Methods: CBCT of 34 temporomandibular joints were taken from 9 male and 8 female patients with CB $Mercuray^{TM}$ (Hitachi, Japan) before and after wearing a CD for rehabilitation. Position of mandibular condyle within articular fossa at centric occlusion was evaluated with $Vimplant2.0^{TM}$ (CyberMed, Korea) on the central parasagittal view and curved panoramic coronal view of the condylar head. A statistical evaluation was done with SPSS. Results: The range of anteroposterior positional rate (AP) of condylar head within articular fossa was -16-5 and -10-12 respectively on the right and left sides. Before wearing CD, the AP rate showed discrepancy between right and left sides (p<0.05). After wearing CD, both condyles showed a tendency to decrease in posterior condylar position (right side; p<0.05). The average discrepancy between right and left side in mediolateral positional rate (MD) was 15.5 and 4.5 respectively before and after wearing CD. The improvement was observed in mediolateral relationship of both condylar heads after wearing CD (p< 0.01). Before wearing CD, the average horizontal angle of long axis of condylar head was $79.6{\pm}2.7^{\circ}\;and\;80.1{\pm}5.7^{\circ}$ respectively on the right and left sides. After wearing CD, both condyles were rotated in the same direction in average on axial plane. Conclusion: We observed with CBCT the significant clinical evidence in case of positional change of mandibular condyle after wearing complete denture.

  • PDF

Marginal and internal fit of 3D printed provisional crowns according to build directions

  • Ryu, Ji-Eun;Kim, Yu-Lee;Kong, Hyun-Jun;Chang, Hoon-Sang;Jung, Ji-Hye
    • The Journal of Advanced Prosthodontics
    • /
    • 제12권4호
    • /
    • pp.225-232
    • /
    • 2020
  • PURPOSE. This study aimed to fabricate provisional crowns at varying build directions using the digital light processing (DLP)-based 3D printing and evaluate the marginal and internal fit of the provisional crowns using the silicone replica technique (SRT). MATERIALS AND METHODS. The prepared resin tooth was scanned and a single crown was designed using computer-aided design (CAD) software. Provisional crowns were printed using a DLP-based 3D printer at 6 directions (120°, 135°, 150°, 180°, 210°, 225°) with 10 crowns in each direction. In total, sixty crowns were printed. To measure the marginal and internal fit, a silicone replica was fabricated and the thickness of the silicone impression material was measured using a digital microscope. Sixteen reference points were set and divided into the following 4 groups: marginal gap (MG), cervical gap (CG), axial gap (AG), and occlusal gap (OG). The measurements were statistically analyzed using one-way ANOVA and Dunnett T3. RESULTS. MG, CG, and OG were significantly different by build angle groups (P<.05). The MG and CG were significantly larger in the 120° group than in other groups. OG was the smallest in the 150° and 180° and the largest in the 120° and 135° groups. CONCLUSION. The marginal and internal fit of the 3D-printed provisional crowns can vary depending on the build angle and the best fit was achieved with build angles of 150° and 180°.

배플이 장착된 로켓 연소기의 선형 안정성 해석 (Linear Stability Analysis of a Baffled Rocket Combustor)

  • 이수용
    • 한국추진공학회지
    • /
    • 제22권3호
    • /
    • pp.46-52
    • /
    • 2018
  • 액체산소 및 탄화수소를 사용하는 연소기의 고주파 연소불안정을 해석하기 위해 단순모델로서 Crocco의 $n-{\tau}$ 시간지연 연소모델을 적용하고, 음향과 커플된 연소기 내 유동에 대해 선형해석을 수행하였다. 변수분리를 통해 편미분 포텐셜함수 식을 원통좌표계 미분방정식으로 만들고, 연소기의 접선방향 공진모드에 대한 고유 값을 계산하였다. 분사면 및 노즐입구를 경계조건으로 적용하여 미분식의 해를 구했다. 시스템의 안정성 판정을 위해 전달함수를 주파수 해석 하였으며, 관심 영역 주파수인 1T 모드 주변 주파수에서 시스템 게인 및 위상각으로 안정성 여유를 평가하였다. 또한 1T 모드 안정성 향상을 위해 배플 길이 및 형상에 대한 영향을 평가하였다.

The reliability of the nonradiologic measures of thoracic spine rotation in healthy adults

  • Hwang, Donggi;Lee, Ju Hyeong;Moon, Seongyeon;Park, Soon Woo;Woo, Juha;Kim, Cheong
    • Physical Therapy Rehabilitation Science
    • /
    • 제6권2호
    • /
    • pp.65-70
    • /
    • 2017
  • Objective: The purpose of this study was to examine the intertester reliability and validity of four nonradiologic measurements of thoracic spine rotation in healthy adults. Design: Descriptive laboratory study. Methods: This study was conducted on 20 male and 20 female university students aged between 19 and 26. To measure thoracic rotation, a goniometer, a bubble inclinometer, a dual inclinometer, and a smartphone application-clinometer were used. The measurement was performed twice for each device and the same measurement was performed by two examiners. The measurements were performed in the lumbar locked position. The arm in the direction of rotation was taken back and placed onto the back of the lumbar region. With right and left trunk rotation, the head was rotated together but remained in the center line so that the axial rotation was maintained. Both examiners performed the measuring procedures and directly handled the measuring instrument. All measurement results were recorded by the recorder. Results: The range of motion (ROM) of thoracic rotation in lumbar locked position for all four devices was 47 degrees. The intra-rater reliability estimates ranged from 0.738 to 0.906 (p<0.05). The inter-rater reliability estimates ranged from 0.736 to 0.853 (p<0.05). The goniometer, bubble inclinometer, dual inclinometer, and smartphone clinometer showed high validity (p<0.05). This result indicates that all four devices may be used by the same examiner and by other examiners obtaining follow-up measurement. Conclusions: The use of the goniometer, bubble inclinometer, dual inclinometer, and smartphone clinometer for measurements in the lumbar locked posture are reliable and valid nonradiologic measures of thoracic rotational ROM in healthy adults.

화학열펌프에 있어서의 무기수화물계 축열시스템에 관한 연구(I) - 탈수 축열 성능연구 - (A Study on the Heat Storage System for Chemical Heat Pump Using Inorganic Hydrates(I) - Heat Storage Characteristics -)

  • 박영해;김종식
    • 태양에너지
    • /
    • 제15권3호
    • /
    • pp.29-38
    • /
    • 1995
  • 본 연구는 화학열펌프 개발을 목적으로 비교적 고온영역에서 화학축열에 응용 가능 할 것으로 판단되는 무기수화물계 $Ca(OH)_2/CaO$ 가역 반응싸이클을 이용한 수화 탈수반응에 따른 충진층내 열이동에 대하여 실험적 검토를 행하였다. 그 결과 본 실험에서 얻은 열교환특성은 $Ca(OH)_2$ 열분해 탈수반응시 반응기 내의 시료층 상단부가 하단부에 비해 탈수반응이 느리게 진행되었으며 이러한 현상은 탈수반응이 하부에서 상부로 진행됨을 알 수 있었다. 또, 반응기내 반경방향에서의 $Ca(OH)_2$ 열분해 탈수반응에 따른 온도변화는 시료 중심부에서 상 하단부로 나타났으며 이는 열전도도에 의한 온도 강하로 중심부의 축열온도가 높음을 알 수 있었다.

  • PDF

전자기 성형에서의 변형률 속도 효과 해석 (Analysis of the Strain Rate Effect in Electro-Magnetic Forming)

  • 곽신웅;신효철;이종수
    • 대한기계학회논문집
    • /
    • 제14권5호
    • /
    • pp.1043-1058
    • /
    • 1990
  • 본 연구에서는 전자기 성형법에 의한 원통형상의 가공재의 자유 확관성형 가 공에 대해서 유한요소해석법을 이용한 변형 및 응력해석을 수행하였다. 탄소성 재료 모형을 확장하여 변형 경화율이 변형률 및 변형률 속도의 지배를 받는 변형률 속도 종 속 탄소성 재료 모형을 도입하였고, 1차 제하 이후까지 포함하여 고속 성형시 변형률 속도 효과에 의해 발생하는 현상들에 대해서 연구하였다.결과의 비교 및 논의를 위 하여, 해석대상과 성형조건, 그리고 가공재에 작용하는 자기압력은 Suzuki의 것과 동 일한 것을 사용하였다.

다짐 화강풍화토의 비등방성 거동특성 (Anisotropic Behavior of Compacted Decomposed Granite Soils)

  • 함태규;효도마사유키;안태봉
    • 한국지반공학회논문집
    • /
    • 제21권7호
    • /
    • pp.5-12
    • /
    • 2005
  • 화강풍화토의 강도와 변형특성을 조사하기 위하여 불포화배수 삼축압축실험을 실시하였다. 본 실험을 위하여 야마구치현의 시모노세키에서 화강풍화토를 구하였으며 주응력방향과 다짐방향을 0,45, 90도의 세가지 방향성을 갖도록 하였다. 등방압축시 발생하는 압축변형률은 다짐각도에 따라 크게 영항을 받는다. 이차압축시의 변형거동에 관한 시간의존성은 다짐각도와 관계가 없다. 다짐각도가 압축강도와 변형에 미치는 영향은 특히 낮은 구속압력시에 크다. 다짐각도가 다르다 하더라도 다일러틴시 비율은 다일러턴시로 인한 강도증가와 상관하여 변화한다. 따라서 다짐풍화토는 초기 비등방성 조직을 갖고 있는 모래와 같이 비등방성 역학적 성질을 갖는다고 할 수 있다.

3차원 수치해석을 이용한 강관합성말뚝의 보강효과 분석 (Analysis of Reinforcement Effect of Steel-Concrete Composite Piles by 3-Dimensional Numerical Analysis)

  • 김성렬;이시훈;정문경;이주형
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2009년도 세계 도시지반공학 심포지엄
    • /
    • pp.404-411
    • /
    • 2009
  • The steel pipe of steel-concrete composite piles increases the pile strength and induces the ductile failure by constraining the deformation of the inner concrete. In this research, the load-movement relations and the reinforcement effect by the outer steel pipe in the steel-concrete composite pile were analyzed by performing three-dimensional numerical analyses, which can simulate the yielding behavior of the pile material and the elasto-plastic behavior of soils. The parameters analyzed in the study include three pile materials of steel, concrete and composite, pile diameter and loading direction. As the results, the axial capacity of the composite pile was 1.9 times larger than that of the steel pipe pile and similar with that of the concrete pile. At the allowable movement criteria, the horizontal capacity of the composite pile was 1.46 times larger than that of the steel pile and 1.25 times larger than that of the concrete pile. In addition, the horizontal movement at the pile head of the composite pile was about 78% of that of the steel pile and about 53% of that of the concrete pile, which showed that the movement reduction effect of the composite pile was significant and enables the economical design of drilled shafts.

  • PDF

A comparison on the heat load of HTS current leads with respect to uniform and non-uniform cross-sectional areas

  • Han, Seunghak;Nam, Seokho;Lee, Jeyull;Song, Seunghyun;Jeon, Haeryong;Baek, Geonwoo;Kang, Hyoungku;Ko, Tae Kuk
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제19권3호
    • /
    • pp.44-48
    • /
    • 2017
  • Current lead is a device that connects the power supply and superconducting magnets. High temperature superconductor (HTS) has lower thermal conductivity and higher current density than normal metal. For these reasons, the heat load can be reduced by replacing the normal metal of the current lead with the HTS. Conventional HTS current lead has same cross-sectional area in the axial direction. However, this is over-designed at the cold-end (4.2 K) in terms of current. The heat load can be reduced by reducing this part because the heat load is proportional to the cross-sectional area. Therefore, in this paper, heat load was calculated from the heat diffusion equation of HTS current leads with uniform and non-uniform cross-sectional areas. The cross-sectional area of the warm-end (65K) is designed considering burnout time when cooling system failure occurs. In cold-end, Joule heat and heat load due to current conduction occurs at the same time, so the cross-sectional area where the sum of the two heat is minimum is obtained. As a result of simulation, current leads for KSTAR TF coils with uniform and non-uniform cross-sectional areas were designed, and it was confirmed that the non-uniform cross-sectional areas could further reduce the heat load.