• 제목/요약/키워드: axial behavior

검색결과 1,555건 처리시간 0.027초

Experimental and numerical studies on mechanical behavior of buried pipelines crossing faults

  • Zhang, Dan F.;Bie, Xue M.;Zeng, Xi;Lei, Zhen;Du, Guo F.
    • Structural Engineering and Mechanics
    • /
    • 제75권1호
    • /
    • pp.71-86
    • /
    • 2020
  • This paper presents a study on the mechanical behavior of buried pipelines crossing faults using experimental and numerical methods. A self-made soil-box was used to simulate normal fault, strike-slip fault and oblique slip fault. The effects of some important parameters, including the displacement and type of fault, the buried depth and the diameter of pipe, on the deformation modes and axial strain distribution of the buried pipelines crossing faults was studied in the experiment. Furthermore, a finite element analysis (FEA) model of spring boundary was developed to investigate the performance of the buried pipelines crossing faults, and FEA results were compared with experimental results. It is found that the axial strain distribution of those buried pipelines crossing the normal fault and the oblique fault is asymmetrical along the fault plane and that of buried pipelines crossing the strike-slip fault is approximately symmetrical. Additionally, the axial peak strain appears near both sides of the fault and increases with increasing fault displacement. Moreover, the axial strain of the pipeline decreases with decreasing buried depth or increasing ratios of pipe diameter to pipe wall thickness. Compared with the normal fault and the strike-slip fault, the oblique fault is the most harmful to pipelines. Based on the accuracy of the model, the regression equations of the axial distance from the peak axial strain position of the pipeline to the fault under the effects of buried depth, pipe diameter, wall thickness and fault displacement were given.

120층 규모 초고층 건물에 대한 횡력저항시스템 적용에 따른 장기거동 분석 (Analysis on Long Term Behavior in 120-Story High-Rise Buildings according to Lateral-Load-Resisting Systems)

  • 김경찬;김재요
    • 한국전산구조공학회논문집
    • /
    • 제35권2호
    • /
    • pp.119-129
    • /
    • 2022
  • 초고층 건물에서 수평변위 제어와 수직부재에서 발생하는 부등축소에 대한 검토가 필수적이다. 이러한 부등축소는 비구조요소의 사용성과 구조요소의 안전성에 대해 문제를 야기할 수 있다. 따라서 이 연구에서는 120층 규모의 철근콘크리트 주거용 초고층 건물에 대해 시공단계해석을 수행하여 각 수직부재의 부등축소량을 비교하고 콘크리트의 장기거동의 영향을 분석하였다. 이를 위해 영향요인에 따라 축소량을 탄성축소량, 크리프축소량, 건조수축축소량으로 구분하여 검토하였으며 최대 절대축소량에 대한 지배적 요인을 분석하였다. 또한, 입주완료 후 30년에서 발생한 부등축소량에 대해 사용성 검토를 진행하였으며, 구조요소에 대해 설계단계와 시공단계의 부재력을 비교하여 분석하였다.

3차원 구성관계를 고려한 FRP-구속 콘크리트의 압축거동 예측모델 (Prediction of Compressive Behavior of FRP-Confined Concrete Based on the Three-Dimensional Constitutive Laws)

  • 조창근;권민호
    • 콘크리트학회논문집
    • /
    • 제16권4호
    • /
    • pp.501-509
    • /
    • 2004
  • 제안된 모델은 FRP 구속 콘크리트에 대한 압축거동 예측을 위한 것이다. FRP로 구속된 콘크리트의 모델링을 위하여, 3축 응력상태의 콘크리트 아탄성 구성관계를 제시하였다. FRP 구속에 따른 콘크리트 강도 증진은 3축 응력공간의 파괴기준에 따라 결정되며, 이에 대응하는 최대 압축변형률은 본 연구에서 제안된 변형률 증진계수로부터 결정된다. 따라서, 기존의 모델들이 하중단계에 관계없이 구속조건이 초기부터 파괴까지 일정하게 고려되는 반면에, 제안된 모델은 FRP로 구속된 콘크리트의 구속현상을 하중단계에 의존적인 비선형 관계로 제시하였다. FRP 층은 2차원의 적층된 복합재료의 해석에 기초하여 모델링되었다. 개발된 해석모델은 증분법에 의한 압축거동실험에 대한 해석을 수행할 수 있도록 하였다. FRP로 구속된 콘크리트 실린더의 대한 여러 연구자들의 실험 결과와 본 예측모델을 비교한 결과, 제안된 모델은 축방향 변형 뿐만 아니라 횡방향 변형을 포함하여 FRP 층으로 인한 콘크리트의 구속효과의 증진에 관한 거동 특성들을 잘 예측해 주었다.

Elastoplastic FEM analysis of earthquake response for the field-bolt joints of a tower-crane mast

  • Ushio, Yoshitaka;Saruwatari, Tomoharu;Nagano, Yasuyuki
    • Advances in Computational Design
    • /
    • 제4권1호
    • /
    • pp.53-72
    • /
    • 2019
  • Safety measures for tower cranes are extremely important among the seismic countermeasures at high-rise building construction sites. In particular, the collapse of a tower crane from a high position is a very serious catastrophe. An example of such an accident due to an earthquake is the case of the Taipei 101 Building (the author was the project director), which occurred on March 31, 2002. Failure of the bolted joints of the tower-crane mast was the direct cause of the collapse. Therefore, it is necessary to design for this eventuality and to take the necessary measures on construction sites. This can only be done by understanding the precise dynamic behavior of mast joints during an earthquake. Consequently, we created a new hybrid-element model (using beam, shell, and solid elements) that not only expressed the detailed behavior of the site joints of a tower-crane mast during an earthquake but also suppressed any increase in the total calculation time and revealed its behavior through computer simulations. Using the proposed structural model and simulation method, effective information for designing safe joints during earthquakes can be provided by considering workability (control of the bolt pretension axial force and other factors) and less construction cost. Notably, this analysis showed that the joint behavior of the initial pretension axial force of a bolt is considerably reduced after the axial force of the bolt exceeds the yield strength. A maximum decrease of 50% in the initial pretension axial force under the El Centro N-S Wave ($v_{max}=100cm/s$) was observed. Furthermore, this method can be applied to analyze the seismic responses of general temporary structures in construction sites.

보수.보강된 RC 구조물의 경계면 파괴를 고려한 수치해석 기법 개발 (Development of Numerical Tool considering Interfacial Fracture Behavior in Repaired RC Structure)

  • 임윤묵;김문겸;신승교;고태호
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2000년도 봄 학술발표회 논문집
    • /
    • pp.553-558
    • /
    • 2000
  • In this study, a numerical simulation that can effectively predict the interfacial fracture behavior in repaired structures is developed using the axial deformation link elements. In repaired structures, concrete and interface are considered as quais-brittle materials, and steel plate as a repair material and reinforcement are modeled as elasto-plastic materials. The behavior of repaired reinforced concrete structures under flexural loading conditions is numerically simulated, and compaired with experimental results. The strengthening effect according to the length and thickness of the repair material is studied and rip-off, debonding and rupture failure mechanism of interface between substrate and repair materials are detected. It is shown that the interface properties affect on the mechanical behavior of repaired structures. Therefore, the developed numerical method using axial deformation link elements can be used for determining the strengthening effects and failure mechanism of repaired structures.

  • PDF

Static behavior of nonlocal Euler-Bernoulli beam model embedded in an elastic medium using mixed finite element formulation

  • Nguyen, Tuan Ngoc;Kim, Nam-Il;Lee, Jaehong
    • Structural Engineering and Mechanics
    • /
    • 제63권2호
    • /
    • pp.137-146
    • /
    • 2017
  • The size-dependent behavior of single walled carbon nanotubes (SWCNT) embedded in the elastic medium and subjected to the initial axial force is investigated using the mixed finite element method. The SWCNT is assumed to be Euler-Bernoulli beam incorporating nonlocal theory developed by Eringen. The mixed finite element model shows its great advantage of dealing with nonlocal behavior of SWCNT subjected to a concentrated load owing to the existence of two coefficients ${\alpha}_1$ and ${\alpha}_2$. This is the first numerical approach to deal with a puzzling fact of nonlocal theory with concentrated load. Numerical examples are performed to show the accuracy and efficiency of the present method. In addition, parametric study is carefully carried out to point out the influences of nonlocal effect, the elastic medium, and the initial axial force on the behavior of the carbon nanotubes.

Behavior of fibre reinforced cementitious material-filled steel tubular columns

  • Kharoob, O.F.;Taman, M.H.
    • Steel and Composite Structures
    • /
    • 제23권4호
    • /
    • pp.465-472
    • /
    • 2017
  • This paper presents an experimental study, investigating the compressive behavior of glass-fibre reinforced and unreinforced cementitious material-filled square steel tubular (GFCMFST and CMFST) columns. The specimens were manufactured by using high performance cementitious materials without using coarse aggregate. The influence of adding glass-fibres to the mix on the behavior of both axially and eccentrically loaded columns is considered. It was found that adding glass fibre improvesthe confinement behavior, the axial compressive strength, the stiffness and the toughness of both axially and eccentrically loaded columns. The compressive strength of axially loaded columns is compared with strength predictions according to EC4 and the AISC specification. It was found that the design predictions according to EC4 and the AISC codes provide conservative results for CMFST and GFCMFST columns. Alternatively, the axial load-bending moment interaction diagrams specified in theEC4 are conservative for the eccentrically tubular CMFST and GFCMFST tested columns.

전좌굴을 고려한 복합적층원통셸의 거동해석 (Behavior Analysis of Laminated Composite Cylindrical Shells with Prebuckling)

  • 이종선
    • 한국생산제조학회지
    • /
    • 제9권5호
    • /
    • pp.150-156
    • /
    • 2000
  • The objective of this study is to investigate effects of prebuckling on the buckling of laminated composite cylindrical shells. Axial compression and lateral pressure are considered for laminated composite cylindrical shells with the ratios of length to radius. The shell walls are made of a laminate with several symmetric ply orientations. The study was made using finite difference energy method, utilizing the nonlinear bifurcation branch with nonlinear prebuckling displacements. The results are compared to the buckling loads determined when membrane prebuckling displacements are considered. Review the influence of nonlinear prebuckling for the buckling loads, the difference between the actual and classical buckling loads are increased as the increments with the ratios of length to radius, for which is applied the axial compression, but almost same for the lateral pressure.

  • PDF

PVA섬유를 사용한 고인성 시멘트 복합체 기둥의 압축거동 (Axial Behavior of High Performance Fiber Reinforced Cementitious Composite Columns with PVA Fibers)

  • 변장배;전수만;전에스더;김선우;황선경;윤현도;임병훈
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2005년도 추계 학술발표회 제17권2호
    • /
    • pp.29-32
    • /
    • 2005
  • An experimental investigation on the strength and behavior of High Performance Fiber Reinforced Cement Composite(HPFRCC) column with Polyvinyl alcohol(PVA) fibers under axial load have been carried out. The columns were subjected to monotonic axial compression until failure. The variables in this study are the combination ratio of PVA, and the volumetric ratio of transverse reinforcement. Test results showed that the fibers, when used in PVA2.0, could result in superior composite performance compared to their individual fiber reinforced cement composites.

  • PDF

정방향 STRC 기둥의 자기이력현상 거동 (Hysteretic Behavior of Reinforced Concrete Columns Confined By Square Steel Tubes.)

  • 왕소용;장수메이;이한승
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2006년도 춘계학술발표회 논문집(I)
    • /
    • pp.430-433
    • /
    • 2006
  • The reinforced concrete column confined by square steel tubes(RCST) is a reinforced column (RC) confined by thin steel tubes which cover over the full length of the column but terminates 15mm from the column's ends. The steel tube is in uniaxial tension stress state and won't buckle when the column sustains axial load. This will highly increase the bearing capacity and ductility of the columns. The hysteretic behavior of four square RCST columns and one square RC column were experimentally studied under constant axial load and lateral cyclic load. The wide-to-thickness (D/t) ratio of RCST columns employed in this research is 75. The main variables of the experiment were axial load ratio and compressive strength of the concrete. Based on the findings in this research, RCST columns exhibits high lateral strength, ductility, and energy dissipation ability.

  • PDF