• 제목/요약/키워드: averaged method

검색결과 1,129건 처리시간 0.027초

신경회로망 기법을 사용한 액체금속원자로 봉다발의 형상최적화 (Shape Optimization of LMR Fuel Assembly Using Radial Basis Neural Network Technique)

  • 라자 와심;김광용
    • 대한기계학회논문집B
    • /
    • 제31권8호
    • /
    • pp.663-671
    • /
    • 2007
  • In this work, shape optimization of a wire-wrapped fuel assembly in a liquid metal reactor has been carried out by combining a three-dimensional Reynolds-averaged Navier-Stokes analysis with the radial basis neural network method, a well known surrogate modeling technique for optimization. Sequential Quadratic Programming is used to search the optimal point from the constructed surrogate. Two geometric design variables are selected for the optimization and design space is sampled using Latin Hypercube Sampling. The optimization problem has been defined as a maximization of the objective function, which is as a linear combination of heat transfer and friction loss related terms with a weighing factor. The objective function value is more sensitive to the ratio of the wire spacer diameter to the fuel rod diameter than to the ratio of the wire wrap pitch to the fuel rod diameter. The optimal values of the design variables are obtained by varying the weighting factor.

다익송풍기 내부 3차원 정상유동의 수치해석 (Analysis of the three-dimensional Steady Flow through A Multi-blade Centrifugal Fan)

  • 서성진;첸시;김광용;강신형
    • 한국유체기계학회 논문집
    • /
    • 제3권1호
    • /
    • pp.19-27
    • /
    • 2000
  • A numerical study is presented for analysis of three-dimensional incompressible turbulent flows in a multi-blade centrifugal fan. Reynolds-averaged Navier-Stokes equations with a standard $k-{\espilon}$ turbulence model are discretized with finite volume approximations. The computational area is divided into three blocks; inlet core, impeller and scroll parts, which are linked by a multi-block method. The flow inside of the fan is regarded as steady flow, and the mathematical models for the impeller forces were established from a cascade theory and measured data. Empirical coefficients are obtained comparing between computational and experimental results for the case without scroll, and are employed to simulate the flow through the impeller with scroll. In comparisons with experimental data, the validity of the mathematical models for the impeller forces was examined. The characteristics of the flow in the scroll were also discussed.

  • PDF

원심다익송풍기 유동의 삼차원 Navier-Stakes 해석 (Three-Dimensional Navier-Stokes Analysis of the Flow through A Multiblade Centrifugal Fan)

  • 서성진;첸시;김광용;강신형
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 1998년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.42-48
    • /
    • 1998
  • Numerical study is presented for the analysis of three-dimensional incompressible turbulent flows in multiblade centrifugal fan. Reynolds-averaged Navier-Stokes equations with standard k - $\epsilon$ turbulence model are transformed to non-orthogonal curvilinear coordinates, and are discretized with finite volume approximations. Linear Upwind Differencing Scheme(LUDS) is used to approximate the convection terms in the governing equations. SIMPLEC algorithm is used as a velocity-pressure correction procedure. The computational area is divided into three blocks; core, impeller and scroll, which are linked by multi-block method. The flow inside of the fan is regarded as steady flow, and mathematical formula established from the cascade theory and empirical coefficient are employed to simulate tile flow through the impeller. From comparisons between the computational results and the experimental data, the validity of the mathematical formula for the blade forces was examined and good results were obtained qualitatively. Hence, we can get the flow characteristics of multi-blade centrifugal fan and it will be a corner stone of the development of the multiblade centrifugal fan.

  • PDF

벽온도분포가 정현파인 원관에서 왕복유동에 의한 열전달 해석 (Heat Transfer by an Oscillating Flow in a Circular Pipe with Sinusoidal Wall Temperature Distributions)

  • 이대영;박상진;노승탁
    • 대한기계학회논문집
    • /
    • 제17권12호
    • /
    • pp.3208-3216
    • /
    • 1993
  • Heat transfer characteristics of the laminar oscillating flow in a circular pipe have been studied under the condition that the wall temperature of the pipe is distributed sinusoidally with the axial direction. The axial velocity was assumed to be uniform in radial direction and the temperature field was analyzed by means of the perturbation method. The results show that the difference between wall and section-time-averaged fluid temperature increases as the oscillating frequency increases and eventually converges to a constant value which is determined by the ratio of swept distance to the characteristic length of wall temperature distribution. Also it is shown that the dominant variable in the heat transfer process when swept distance ratio is greater than 1 is not thermal Womersley number(F) but thermal Womersley number multiplied by the square root of swept distance ratio. The variation of the time-averaged Nusselt number is obtained as a function of F. The results indicate that Nusselt number is proportional to $F_{\epsilon}^{1/2}$ when both of F and .epsilon. are much greater than 1.

내.외과계 간호사의 통증 관리에 대한 지식 및 태도 (Pain Management Knowledge and Attitude of Internal Medicine and Surgery Stream Nurses)

  • 송승순;박재순
    • 가정∙방문간호학회지
    • /
    • 제17권1호
    • /
    • pp.55-62
    • /
    • 2010
  • Purpose: This study investigated the sought to identify the pain management knowledge and attitude of nurses in internal medicine and surgery stream wards and intensive care units to obtain basic information needed for improved pain control. Method: Data was collected through self-reported questionnaires and analyzed by descriptive statistics, t-test and ANOVA using SPSS Win 12.0. Results: Pain management knowledge score averaged 51.1 out of 100, with significant differences evident depending on age, marital status, educational level, position, total work career, working department and cancer care-giving experience. Pain management attitude score averaged 2.9 out of 4, and significant differences were evident depending on age, marital status, educational level, position, total work career, working department, cancer care-giving experience, education experience and number of patients treated. Conclusion: Further studies are necessary to develop effective nursing knowledge and attitude education programs and evaluation such as discussion by cases, workshops, system of expert help for uncontrollable pain or a multi-disciplinary pain management task force. In addition, patient satisfaction level with pain management should be assessed and the responses reflected practically.

  • PDF

와추적 위상평균 기법을 이용한 원주후류의 PIV측정 (PIV Measurement of Circular Cylinder Wake Using Vortex Tracking Phase-Average Technique)

  • 김경천;윤상열;김상기;부정숙
    • 대한기계학회논문집B
    • /
    • 제25권7호
    • /
    • pp.915-922
    • /
    • 2001
  • A new phase-average technique using instantaneous velocity fields obtained by a PIV method has been developed. The technique tracks vorticity centers and estimates the value of circulation for a chosen domain. The locations of vortex-centers and the magnitudes of circulation are matched together then showing a sine wave feature due to the periodic vortex shedding from the circular cylinder. Ensemble averaged and phase averaged velocity fields are successfully measured for the circular cylinder wake where Reynolds number is 3900 based on free stream velocity and cylinder diameter. The convection velocities of the vortices center and the vortex shedding frequency were measured by a single hot-wire probe.

가스터빈블레이드에서 일렬의 제트에 의한 막냉각특성 연구 (Film Cooling by a Row of Jets in a Gas Turbine Blade)

  • 이용덕;이재헌
    • 대한기계학회논문집
    • /
    • 제18권7호
    • /
    • pp.1851-1865
    • /
    • 1994
  • The objective of the present study is to predict the film cooling effectiveness by a row of holes at various injection ratios and injection angles. Numerical calculations have been performed to investigate the characteristics of flow and temperature distributions in a region near the down-stream of injection hole including the region of adverse pressure gradient. The elliptic turbulent 3-dimensional governing equations with variable thermal properties using the low-Reynolds number k-$\bar{varepsilon}$ model was solved by SIMPLE algorithm. The results showed that the presence of adverse pressure gradient and secondary vortex in the region near the downstream of injection hole induces large temperature gradent. The $45^{\circ}$ injection has higher averaged film cooling effectiveness than $60^{\circ}$ injection. But neverthless the $90^{\circ}$ injection has greater deviation from a flat plate than $45^{\circ}$ and $60^{\circ}$ injection, the $90^{\circ}$ injection has higher averaged film cooling effectiveness than $45^{\circ}$ and $60^{\circ}$ injection in the region near the downstream of injection hole.

Application of DFB Diode Laser Sensor to Reacting Flow (II) - Liquid-Gas 2-Phase Reacting Flow -

  • Park, Gyung-Min;Masashi Katsuki;Kim, Duck-Jool
    • Journal of Mechanical Science and Technology
    • /
    • 제17권1호
    • /
    • pp.139-145
    • /
    • 2003
  • Diode laser sensor is conducted to measure the gas temperature in the liquid-gas 2-phase counter flow flame. C$\_$10/H/ sub 22/ and city gas were used as liquid fuel and gas fuel, respectively. Two vibrational overtones of H$_2$O were selected and measurements were carried out in the spray flame region stabilized the above gaseous premixed flame. The path-averaged temperature measurement using diode laser absorption method succeeded in the liquid fuel combustion environment regardless of droplets of wide range diameter. The path-averaged temperature measured in the post flame of liquid-gas 2-phase counter flow flame showed qualitative reliable results. The successful demonstration of time series temperature measurement in the liquid-gas 2-phase counter flow flame gave us motivation of trying to establish the effective control system in practical combustion system. These results demonstrated the ability of real-time feedback from combustor inside using the non-intrusive measurement as well as the possibility of application to practical combustion system. Failure case due to influence of spray flame was also discussed.

THE EFFICIENCY OF UTILIZATION OF METABOLIZABLE ENERGY OF MILK-REPLACER-FED CALVES AT WEANING PERIOD

  • Sekine, J.;Morita, Z.;Oura, R.;Morooka, T.;Asahida, Y.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제1권4호
    • /
    • pp.185-187
    • /
    • 1988
  • A total of 22 energy balance trials were done for calves fed a liquid milk replacer, calf starter and second cut mixed hay during weaning period. Milk replacer supplied 50% of the total dietary energy, calf starter 42% and hay 8% Live weight of calves averaged 64.6 ($S.D.{\pm}7.8$) kg and daily gain 0.54 (${\pm}0.22$) kg. The metabolizability of gross energy averaged 0.751. A regression was calculated relating energy retention (ER, $kJ/kg^{0.75}$) to the intake of metabolizable energy (IME, $kJ/kg^{0.75}$): $$ER=0.69({\pm}0.09)IME-395,\;r=0.888,\;P<0.01,\;S.E.{\pm}7.1$$. Metabolizable energy for maintenance (MEm) was calculated to be $572kJ/kg^{0.75}$ when ER = 0. The amount of IME over MEm for an individual animal (MEg, $kJ/kg^{0.75}$) was regressed on average daily gain (ADG, kg) by the method of regression through the origin: $$MEg=364({\pm}55)ADG,\;r=0.634,\;P<0.01,\;S.E.{\pm}12$$. The amount of ME required for maintenance and growth was estimated to be $936kJ/kg^{0.75}$.

DIFFUSION PIECEWISE HOMOGENIZATION VIA FLUX DISCONTINUITY RATIOS

  • Sanchez, Richard;Dante, Giorgio;Zmijarevic, Igor
    • Nuclear Engineering and Technology
    • /
    • 제45권6호
    • /
    • pp.707-720
    • /
    • 2013
  • We analyze piecewise homogenization with flux-weighted cross sections and preservation of averaged currents at the boundary of the homogenized domain. Introduction of a set of flux discontinuity ratios (FDR) that preserve reference interface currents leads to preservation of averaged region reaction rates and fluxes. We consider the class of numerical discretizations with one degree of freedom per volume and per surface and prove that when the homogenization and computing meshes are equal there is a unique solution for the FDRs which exactly preserve interface currents. For diffusion submeshing we introduce a Jacobian-Free Newton-Krylov method and for all cases considered obtain an 'exact' numerical solution (eight digits for the interface currents). The homogenization is completed by extending the familiar full assembly homogenization via flux discontinuity factors to the sides of regions laying on the boundary of the piecewise homogenized domain. Finally, for the familiar nodal discretization we numerically find that the FDRs obtained with no submesh (nearly at no cost) can be effectively used for whole-core diffusion calculations with submesh. This is not the case, however, for cell-centered finite differences.