• Title/Summary/Keyword: average plane

Search Result 537, Processing Time 0.032 seconds

Estimation of Illuminant Chromaticity by Equivalent Distance Reference Illumination Map and Color Correlation (균등거리 기준 조명 맵과 색 상관성을 이용한 조명 색도 추정)

  • Kim Jeong Yeop
    • KIPS Transactions on Software and Data Engineering
    • /
    • v.12 no.6
    • /
    • pp.267-274
    • /
    • 2023
  • In this paper, a method for estimating the illuminant chromaticity of a scene for an input image is proposed. The illuminant chromaticity is estimated using the illuminant reference region. The conventional method uses a certain number of reference lighting information. By comparing the chromaticity distribution of pixels from the input image with the chromaticity set prepared in advance for the reference illuminant, the reference illuminant with the largest overlapping area is regarded as the scene illuminant for the corresponding input image. In the process of calculating the overlapping area, the weights for each reference light were applied in the form of a Gaussian distribution, but a clear standard for the variance value could not be presented. The proposed method extracts an independent reference chromaticity region from a given reference illuminant, calculates the characteristic values in the r-g chromaticity plane of the RGB color coordinate system for all pixels of the input image, and then calculates the independent chromaticity region and features from the input image. The similarity is evaluated and the illuminant with the highest similarity was estimated as the illuminant chromaticity component of the image. The performance of the proposed method was evaluated using the database image and showed an average of about 60% improvement compared to the conventional basic method and showed an improvement performance of around 53% compared to the conventional Gaussian weight of 0.1.

Development of a polystyrene phantom for quality assurance of a Gamma Knife®

  • Yona Choi;Kook Jin Chun;Jungbae Bahng;Sang Hyoun Choi;Gyu Seok Cho;Tae Hoon Kim;Hye Jeong Yang;Yeong Chan Seo;Hyun-Tai Chung
    • Nuclear Engineering and Technology
    • /
    • v.55 no.8
    • /
    • pp.2935-2940
    • /
    • 2023
  • A polystyrene phantom was developed following the guidance of the International Atomic Energy Association (IAEA) for gamma knife (GK) quality assurance. Its performance was assessed by measuring the absorbed dose rate to water and dose distributions. The phantom was made of polystyrene, which has an electron density (1.0156) similar to that of water. The phantom included one outer phantom and four inner phantoms. Two inner phantoms held PTW T31010 and Exradin A16 ion chambers. One inner phantom held a film in the XY plane of the Leksell coordinate system, and another inner phantom held a film in the YZ or ZX planes. The absorbed dose rate to water and beam profiles of the machine-specific reference (msr) field, namely, the 16 mm collimator field of a GK PerfexionTM or IconTM, were measured at seven GK sites. The measured results were compared to those of an IAEA-recommended solid water (SW) phantom. The radius of the polystyrene phantom was determined to be 7.88 cm by converting the electron density of the plastic, considering a water depth of 8 g/cm2. The absorbed dose rates to water measured in both phantoms differed from the treatment planning program by less than 1.1%. Before msr correction, the PTW T31010 dose rates (PTW Freiberg GmbH, New York, NY, USA) in the polystyrene phantom were 0.70 (0.29)% higher on average than those in the SW phantom. The Exradin A16 (Standard Imaging, Middleton, WI, USA) dose rates were 0.76 (0.32)% higher in the polystyrene phantom. After msr correction factors were applied, there were no statistically significant differences in the A16 dose rates measured in the two phantoms; however, the T31010 dose rates were 0.72 (0.29)% higher in the polystyrene phantom. When the full widths at half maximum and penumbras of the msr field were compared, no significant differences between the two phantoms were observed, except for the penumbra in the Y-axis. However, the difference in the penumbra was smaller than variations among different sites. A polystyrene phantom developed for gamma knife dosimetry showed dosimetric performance comparable to that of a commercial SW phantom. In addition to its cost effectiveness, the polystyrene phantom removes air space around the detector. Additional simulations of the msr correction factors of the polystyrene phantom should be performed.

Paleostress Inferred from Calcite Twins in the Pungchon Limestone, Joseon Supergroup (조선누층군 풍촌석회암 방해석 쌍정에서 유추된 고응력장)

  • Kang, Seong-Seung;Jang, Bo-An
    • The Journal of Engineering Geology
    • /
    • v.32 no.1
    • /
    • pp.13-26
    • /
    • 2022
  • Calcite twins were analyzed in six oriented samples of the Pungchon limestone, Joseon Supergroup, to reconstruct the paleostress field. The orientations of c-axis of calcite and e twin plane were measured along with the average thickness and numbers of twins, and the widths of calcite grains. Twin strain, mean width, and intensity of twinning, and the relative magnitude and orientations of principal stresses were calculated using Calcite Strain Gauge program. Twin strain, mean width, and intensity of twinning showed ranges of 1.09-15.36%, 0.53-3.72 ㎛ and 21.0-53.1 twim/mm, respectively. Metamorphic temperatures calculated from the twins were 170-200℃, indicating that the twins developed after the Pungchon limestone was uplifted to at least half of the maximum burial depth. Results for five of the samples indicate that the calcite twins formed during two events with principal stress axes of different orientations, while the remaining sample recorded only one event that produced calcite twins. The axis of maximum compressive stress was oriented mainly WNW-ESE to ENE-WSW, and to a lesser degree NW-SE and NE-SW. Comparison of paleostress orientations measured here and in other studies indicates that most twins were produced during the Songrim orogeny. However, the Daebo orogeny and the Bulguksa orogeny also produced calcite twins in the Punchon limestone.

Domain Knowledge Based Approach for Design Optimization of Arch Dams Using Genetic Algorithms

  • Dongsu Kim;Sangik Lee;Jonghyuk Lee;Byung-hun Seo;Yejin Seo;Dongwoo Kim;Yerim Jo;Won Choi
    • International conference on construction engineering and project management
    • /
    • 2024.07a
    • /
    • pp.1321-1321
    • /
    • 2024
  • Concrete arch dams, unlike conventional concrete gravity dams, have thin arch-shaped cross sections and must be designed considering a three-dimensional shape. In particular, double-curvature arch dams, which have arch-shaped vertical and horizontal sections, require careful consideration during design due to their unique shape. Although stress analysis is complex, and various factors need to be considered during the design, these dams offer economic advantages as they require less material. Consequently, numerous double-curvature arch dams have been constructed worldwide, and ongoing research focuses on optimizing their shapes. In this study, an efficient optimization algorithm was developed for the shape optimization of concrete arch dams with double-curvature using genetic algorithms and improved population initializing technique. The developed technique utilized domain knowledge in the field of arch dams to generate an excellent initial population. To assess the relevance of domain knowledge, an investigation was conducted on the accumulated knowledge and empirical formulas from literature. Two pieces of domain knowledge can be gleaned from the iterative structural design experiences associated with arch dams. First, it concerns the thickness of the central cantilever of an arch dam. For minimum tensile stress, it is best to make the thickness as thin as possible at the dam crest and gradually become thicker as it goes down. The second aspect concerns the sliding stability of the arch dam, which depends on the central angle of the horizontal section. This angel is important for stability because the plane arch serves to transfer the hydraulic load from the reservoir to both abutments. Also, preliminary design formulas for arch dams from a manual written by the United States Bureau of Reclamation (USBR) were used. On the other hand, since domain knowledge is based on engineering experiences and data from existing dams, its usability should be verified by comparing it with the results of design optimization performed by classic genetic algorithms. To validate the performance of the optimization algorithm with the improved population initialization technique, a test site with an existing dam was selected, and algorithmic application tests were conducted. Stress analysis is performed for each design iteration, evaluating constraints and calculating fitness as the objective function. The results confirmed that the algorithm developed in this study exhibits superior performance in terms of average fitness and convergence rate compared to classic genetic algorithms.

A Study on Comparison of Strength Parameters of Hydrostatic Pressure-Dependent Yield Criteria (정수압에 의존하는 항복기준의 강도정수 비교연구)

  • Lee, Seung-Hyun;Han, Jin-Tae
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.7
    • /
    • pp.529-535
    • /
    • 2016
  • In this theoretical study, the strength parameters of the Drucker-Prager yield criterion and Mohr-Coulomb yield criterion were set to equal values, in order to analyze the correlation among the parameters. The Drucker-Prager strength parameters ${\alpha}$ and k were represented by the Mohr-Coulomb strength parameters c and ${\phi}$. Specifically it can be seen that k is function of c, ${\phi}$ and ${\alpha}$ is function of ${\phi}$ alone. Drucker-Prager strength parameter ${\alpha}$ increases as the internal friction angle of soil increases. ${\alpha}_{av}$ which is the average of ${\alpha}_c$ and ${\alpha}_i$ was proportional to internal friction angle in which ${\alpha}_c$ and ${\alpha}_i$ are ${\alpha}$ values corresponding to the circles of the Drucker-Prager yield cirteria circumscribes and inscribes the Mohr-Coulomb yield criterion respectively. The values of the ${\alpha}_{av}$ was 0.07 and 0.29 which correspond to the internal friction angle of $10^{\circ}$ and $45^{\circ}$ respectively. In addition, value of ${\alpha}_c/{\alpha}_i$ was proportional to internal friction angle of soil and the values of ${\alpha}_c/{\alpha}_i$ 1.12 and 1.62 which corresponds to internal friction angle of $10^{\circ}$ and $45^{\circ}$ respectively.The influence of the Mohr-Coulomb strength parameters on the Drucker-Prager strength parameter k was investigated and it was found that k was mainly influenced by the cohesion of the soil, except in the case of the minimum assumed value of c of 10kPa. The deviator stresses, $S_{c0}$ and $S_{t0}$, which correspond to the cases of the Mohr-Coulomb yield criterion under uniaxial compression and uniaxial tension, respectively, and $S_{0(ave)}$, which is the average value of $S_{c0}$ and $S_{t0}$, decrease as the internal friction angle increases. Furthermore, the hexagon, which represents the Mohr-Coulomb yield locus, becomes more irregular, and the deviations of $S_{c0}$ and $S_{t0}$ from $S_{0(ave)}$ also increase, as the internal friction angle increases.

Development of the Multi-Parametric Mapping Software Based on Functional Maps to Determine the Clinical Target Volumes (임상표적체적 결정을 위한 기능 영상 기반 생물학적 인자 맵핑 소프트웨어 개발)

  • Park, Ji-Yeon;Jung, Won-Gyun;Lee, Jeong-Woo;Lee, Kyoung-Nam;Ahn, Kook-Jin;Hong, Se-Mie;Juh, Ra-Hyeong;Choe, Bo-Young;Suh, Tae-Suk
    • Progress in Medical Physics
    • /
    • v.21 no.2
    • /
    • pp.153-164
    • /
    • 2010
  • To determine the clinical target volumes considering vascularity and cellularity of tumors, the software was developed for mapping of the analyzed biological clinical target volumes on anatomical images using regional cerebral blood volume (rCBV) maps and apparent diffusion coefficient (ADC) maps. The program provides the functions for integrated registrations using mutual information, affine transform and non-rigid registration. The registration accuracy is evaluated by the calculation of the overlapped ratio of segmented bone regions and average distance difference of contours between reference and registered images. The performance of the developed software was tested using multimodal images of a patient who has the residual tumor of high grade gliomas. Registration accuracy of about 74% and average 2.3 mm distance difference were calculated by the evaluation method of bone segmentation and contour extraction. The registration accuracy can be improved as higher as 4% by the manual adjustment functions. Advanced MR images are analyzed using color maps for rCBV maps and quantitative calculation based on region of interest (ROI) for ADC maps. Then, multi-parameters on the same voxels are plotted on plane and constitute the multi-functional parametric maps of which x and y axis representing rCBV and ADC values. According to the distributions of functional parameters, tumor regions showing the higher vascularity and cellularity are categorized according to the criteria corresponding malignant gliomas. Determined volumes reflecting pathological and physiological characteristics of tumors are marked on anatomical images. By applying the multi-functional images, errors arising from using one type of image would be reduced and local regions representing higher probability as tumor cells would be determined for radiation treatment plan. Biological tumor characteristics can be expressed using image registration and multi-functional parametric maps in the developed software. The software can be considered to delineate clinical target volumes using advanced MR images with anatomical images.

Comparison of relative fitness between zirconia single coping and 3-unit fixed partial dentures (FPDs) manufactured by dental CAD/CAM system (치과 캐드/캠 시스템으로 제작된 지르코니아 single 코핑과 3-unit 구조물의 상대적 적합도 비교)

  • Lee, Wan-Sun;Park, Jong-Kyoung;Kim, Wook-Tae
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.30 no.1
    • /
    • pp.16-22
    • /
    • 2014
  • Purpose: The purpose of this study was to assess the marginal and mesial fitness of zirconia single copings and 3-unit fixed partial dentures (FPDs) manufactured with an identical model. Materials and Methods: An epoxy model in which the maxillary right 2nd premolar is lost and maxillary 1st premolar and 2nd molar are formed as abutments was manufactured and scanned by using a laser scanner. A ten units of zirconia single copings were manufactured for maxillary 1st premolar and 2nd molar, respectively and the same number of 3-unit FPDs were manufactured. For the measurements of fitness, the manufactured silicone replicas were divided into four parts and the fitness were measured by digital microscope at measurement points (P1, P2, P3, P4 and P5) of each plane. The measured gaps were classified into three categories: marginal gap (MG, P1), axial gap (AG, average of P2 and P3), occlusal gap (OG, average of P4 and P5). Results: The ranges of MG, AG and OG for single copings were 18.47 - 40.54 ${\mu}m$, 39.73 - 73.61 ${\mu}m$ and 116.90 - 134.69 ${\mu}m$, respectively. The ranges of MG, AG and OG for 3-unit FPDs were 45.95 - 87.44 ${\mu}m$, 23.78 - 57.00 ${\mu}m$ and 99.89 - 131.06 ${\mu}m$, respectively. Conclusion: The result of the study shows that the MGs for 3-unit FPDs were higher than those of single copings, though they are within the range of clinical acceptance, indicating that the use of more homogeneous zirconia block and modification of sintering processes are needed to ensure the prevention of increase of gap in 3-unit FPDs.

An Experimental Study to Improve Permeability and Cleaning Efficiency of Oil Contaminated Soil by Plasma Blasting (플라즈마 블라스팅을 이용한 유류오염토양의 투수성과 정화효율 개선을 위한 실험적 연구)

  • Jang, Hyun-Shic;Kim, Ki-Joon;Song, Jae-Yong;An, Sang-Gon;Jang, Bo-An
    • The Journal of Engineering Geology
    • /
    • v.30 no.4
    • /
    • pp.557-575
    • /
    • 2020
  • Plasma blasting which is generated by high voltage arc discharge of electricity is applied to soil mass to improve permeability of soil and cleaning efficiency of oil contamination. A new high voltage generator was manufactured and three types of soil including silty sand, silty sand mixed with lime and silty sand mixed with cement were prepared. Small and large soil columns were produced using these types of soil and plasma blasting was performed within soil columns to investigate the variation of soil volume penetrated by fluid and permeability. Soil volume penetrated by fluid increased by 11~71% when plasma blasting was applied in soil. Although plasma blasting with low electricity voltage induced horizontal fracture and fluid penetrated along this weak plane, plasma blasting with high voltage induced spherical penetration of fluid. Plasma blasting increased the permeability of soil. Permeabilty of soils mixed with lime and cement increased by 450~1,052% with plasma blasting. Permeability of soil increased as discharge voltage increased when plasma blasing was applied once. However, several blastings with the same discharge voltage increase or decrease permeability of soil. Oil contaminated soil was prepared by adding diesel into soil artificially and plasma blasting was performed in these oil contaminated soil. Cleaning efficiency increased by average of 393% for soil located nearby the blasting and by average of 239% for soil located far from the blasting. Cleaning efficiency did not show any correlation with discharge voltage. All these results indicated that plasma blasting might be used for in-situ cleaning of oil contaminated soil because plasma blasting increased permeability of soil and cleaning efficiency.

Analysis of the primary and the permanent teeth dimension In korean hemifacial microsomia patients (한국인 반안면 왜소증 환자의 유치와 영구치 크기에 관한 연구)

  • Chang, Young-Il;Yang, Won-Sik;Nahm, Dong-Seok;Kim, Tae-Woo;Baek, Seung-Hak
    • The korean journal of orthodontics
    • /
    • v.30 no.1 s.78
    • /
    • pp.43-52
    • /
    • 2000
  • Hemifacial microsomia ( HFM ) is the second most common craniofacial abnormalies. HFM represnted a spectrum of clinical findings such as hypoplasia of the mandibular ramus and condyle, confinement of maxilla growth, external and/or middle ear defects, involvement of some cranial suture, buccal soft tissue, facial nerve, and muscles in the affected side. HFM often showed progressive facial asymmetry and occlusal plane slanting to the affected side with growth. There were several reports about asymmetry of tooth maturation, hypodontia, delayed eruption, enamel hypoplasia in HFM. Since teeth develope in close association with size and morphology of the maxillary and the mandible, it is highly likely that dental changes will be present in HFM. So the Purpose of this study was to investigate the differences of the primary and the permanent teeth dimensions in the maxillary and the mandibular dentition between the affected and the non-affected side of HFM.. The sample of this study consisted of 34 unilateral HFM Patients (18 males and 16 females, average age : 5 year 11 months old). The authors examined the mesiodistal and the faciolingual dimensions of the primary and the permanent teeth and performed statistical study by using paired t-test. The results were as follows 1. The mesiodistal dimensions of the mandibular second primary molar and the mandibular first permanent molar in the affected side of HFM were significantly smaller than those of non-affected side. But there were no significant differences in the anterior teeth and the mandibular first primary molar. It means that a gradient of severity from anterior teeth to posterior teeth was found in the mandibular dentition. 2. Although there were no significant differences in the faciolingual dimensions of the primary and the permanent teeth in the maxillary and the mandibular dentition between the affected and non-affected side of HFM, there were general trend of compensatory increase in faciolingual dimension of the mandibular primary and the permanent teeth in the affected side Therefore these results showed that HFM might affect on the abnormality of tooth dimension, especially the most posterior teeth, in the affected side of the mandible.

  • PDF

Suppression of misfit dislocations in heavily boron-doped silicon layers for micro-machining (마이크로 머시닝을 위한 고농도로 붕소가 도핑된 실리콘 층의 부정합 전위의 억제)

  • 이호준;김하수;한철희;김충기
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.33A no.2
    • /
    • pp.96-113
    • /
    • 1996
  • It has been found that the misfit dislocations in heavily boron-doped layers originate from wafer edges. Moreover, the propagation of the misfit dislocation into a heavily boron-doped region can be suppressed by placing a surrounding undoped region. Using a surrounding undoped region the disloction-free heavily boron-deoped silicon membranes have been fabricated. The measured surface roughness, fracture strength, and residual tensile stress of the membrane are 20.angs. peak-to-peak, 1.39${\times}$10$^{10}$ and 2.7${\times}$10$^{9}$dyn/cm$^{2}$, while those of the conventional heavily boron-doped silicon membrane with high density of misfit dislocations are 500 peak-to-peak, 8.27${\times}$10$^{9}$ and 9.3${\times}$10$^{8}$dyn/cm$^{2}$ respectively. The differences between these two membranes are due to the misfit dislocations. Young's modulus has been extracted as 1.45${\times}$10$^{12}$dyn/cm$^{2}$ for both membranes. Also, the effective lattice constant of heavily boron-doped silicon, the in-plane lattice constant of the conventional membrane, and the density of misfit dislocation contained in the conventional membrane have been extracted as density of misfit dislocation contained in the conventional membrane have been extracted as density of misfit dislocation contained in the conventional membrane have been extracted as 5.424.angs. 5.426.angs. and 2.3${\times}$10$^{4}$/cm for the average boron concentration of 1.3${\times}$10$^{20}$/cm$^{-23}$ cm$^{3}$/atom. Without any buffer layers, a disloction-free lightly boron-doped epitaxial layer with good crsytalline quality has been directly grown on the dislocation-free heavily boron-doped silicon layer. X-ray diffraction analysis revealed that the epitaxial silicon has good crystallinity, similar to that grown on lightly doped silicon substrate. The leakage current of the n+/p gated diode fabricated in the epitaxial silicon has been measured to be 0.6nA/cm$^{2}$ at the reverse bias of 5V.

  • PDF