• Title/Summary/Keyword: average plane

Search Result 537, Processing Time 0.032 seconds

Effect of a Finite Substrate on the Radiation Characteristics of a Linear Phased Array Antenna Positioned along the E-plane (유한한 기판 크기가 E-평면으로 배열된 선형 위상 배열 안테나의 방사 특성에 미치는 영향)

  • Kim, Tae-Young;Kim, Gun-Su;Yoon, Young-Min;Kim, Boo-Gyoun
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.48 no.5
    • /
    • pp.46-53
    • /
    • 2011
  • The effect of a finite substrate on the radiation characteristics of a linear 7-element array antenna positioned along the E-plane is investigated. Active reflection coefficients and average active element patterns are simulated for various substrate sizes. The E-plane radiation pattern of a fully excited array for various scan angles is correlated with the active reflection coefficient and average acitive element pattern. The effect of E-plane substrate size on the radiation characteristics of a linear array along the E-plane is larger than that of H-plane substarte size.

A STUDY ON THE OCCLUSAL PLANE INCLINATION IN LATERAL CEPHALOGRAPH (교합평면 경사도에 관한 두부방사선학적 연구)

  • Lee, Sung-Youn;Chang, Young-Il
    • The korean journal of orthodontics
    • /
    • v.21 no.2 s.34
    • /
    • pp.367-397
    • /
    • 1991
  • This study was aimed to investigate the occlusal plane inclination in relation to the skeletal and dental assessment measurements in order to provide a reference in orthodontic treatment planning as the occlusal plane should be reconstructed orthodontically or gnathologically. The sample consisted of 73 normal occlusions and 113 malocclusions of adults. The computerized statistical analysis of 38 occlusal plane's and 29 skeletal and dental measurements were carried out with SPSS. The conclusions were as follows; 1 In normal occlusion, COP-NaPog was average $83.63^{\circ}$ (2.44) and occlusal plane inclination had a strong negative correlation with SNB and FH-NaPog. 2. In normal occlusion, ArANS plane was nearly parallel to the occlusal plane. 3. In malocclusion, the larger the mandibular plane angle and the shorter the ramus height was, the more downward the occlusal plane had a tendency to tip anteriorly. 4. Occlusal plane was more horizontal in deep bite group, while it was steeper in openbite group. 5. The curve of Spee was severe in deep bite group but in openbite group mandibular occlusal plane showed average reverse curvature, where it was found that the configuration of the occlusal plane contributed to the excess or deficiency of anterior overbite.

  • PDF

Fluid Force Suppression of a Square Prism near Plane Wall (벽면근처에 놓인 정방형주의 유체력 제어)

  • Kim, K.S.;Ro, Ki-Deok;Kang, M.H.;Byun, Y.S.
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2006.06a
    • /
    • pp.61-62
    • /
    • 2006
  • The suppression of fluid force acting on a square prism near plane wall was studied by attaching fences on the comers of the prism. The height of the fence was 10% of the square width and the range of Reynolds number considered was $Re=2.0{\times}10^4$. The experimental parameters were the attaching position and numbers of fences, the space ratios $G/B(G/B=0.1{\sim}1.2)$ between prism and plane wall. The average drag coefficients were increased and the average hit coefficients were decreased and increased with the space ratios foulard plane wall. The drag of the prism was reduced average 7.6% with the space ratios by attaching the normal fence at the rear and upper comer and the horizontal normal fence at the rear and lower corner on the prism.

  • PDF

Drag Reduction by Fence of a Square Prism near Plane Wall (벽면근처에 놓인 정방형주의 펜스에 의한 항력저감)

  • Ro, Ki-Deok;Kim, Kwang-Seok
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.2567-2572
    • /
    • 2007
  • The suppression of fluid force acting on a square prism near plane wall was studied by attaching fences on the corners of the prism. The height of the fence was 10% of the square width and the range of Reynolds number considered was Re=$2.0{\times}10^4$. The experimental parameters were the attaching position and numbers of fences, the space ratios G/B(G/B=0.1${\sim}$1.2) between prism and plane wall. The average drag coefficients were increased and the average lift coefficients were decreased and increased with the space ratios toward plane wall. The drag of the prism was reduced average 7.6% with the space ratios by attaching the normal fence at the rear and upper corner and the horizontal normal fence at the rear and lower corner on the prism. In this case, the separated flow at the front and upper corner was reattached on the upper side of the prism and the vortex streets between the prism and plane wall were appeared more slowly than that of prism without fences.

  • PDF

Slit Folded Type Microstrip Antenna for Omnidirectional E-plane and H-plane (전방향성 E & H면 슬릿 Folded형 마이크로스트립 패치 안테나)

  • 김종래;우종명;오승엽
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.13 no.9
    • /
    • pp.956-963
    • /
    • 2002
  • A linearly polarized folded type and H-shape slit folded type microstrip patch antenna at GPS(center frequency:1.575 GHz) were designed and fabricated by folding a conventional single $\lambda_{g}/2(\lambda_{g}:wavelength)$ rectangular patch a half along the length direction at the center of patch and inserting ground plane in the middle. As a result, two types of omnidirectional radiation patterns for E-plane (for zx-plane) in the direction of the length of patch and H-plane (for xy-plane) have been acquired. The experimental results show that the average gains of folded type and slit folded type for omnidirectional E-plane and H-plane are -1.5 dBd (-2.4 dBd) and -3.27 dBd(-2.5 dBd). Slit folded type microstrip patch antenna was more miniaturized than folded type microstrip patch antenna by 27.5 %. In case of slit folded type antenna, average gains of omnidirectional radiation pattern for E & H-plane are almost same.

Minimizing the Average Distance of Separated Points on the Plane in the L1-Distance

  • Kim, Jae-Hoon
    • Journal of information and communication convergence engineering
    • /
    • v.10 no.1
    • /
    • pp.1-4
    • /
    • 2012
  • Given separated points divided by a line, called a wall, in a plane, we aim to make a gate in the wall to connect the separated points to each other. In this setting, the problem is to find a location for the gate that minimizes the average distance between the points. The problem is a variant of the well-known facility location problem, which is extensively studied in the fields of operations research, location theory, theoretical computer science, and so on. In this paper, we consider the $L^1$-distance of the points in the plane. The points are projected onto the wall and so the problem is transformed to a proximity problem of points on a line. Then it is shown that the transformed problem is related to the weighted median problem of points on the line. Therefore, we obtain an O(n log n)-time algorithm to solve our problem.

Study about the relationship between the amount of posterior impaction and the change of occlusal plane angle and incisor inclination in Le Fort I osteotomy (Le Fort I 골절단술에서 posterior impaction의 양과 occlusal plane angle, incisor inclination의 변화 관계에 관한 연구)

  • Kim, Bok-Joo;Kim, Min-Gu;Kim, Jung-Han;Kim, Chul-Hoon
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.36 no.5
    • /
    • pp.375-379
    • /
    • 2010
  • Introduction: In the management of dentofacial deformities, variable movement of the maxilla can be made possible by a Le Fort I osteotomy. Posterior impaction of the maxilla necessary for rotation of the maxillomandibular complex enhances the functions and esthetic results. In cases of posterior impaction of the maxilla, an increase in the figure of the occlusal plane angle and incisor inclination can occur. This study reports the relationship between the amount of posterior impaction and the change in the occlusal plane angle and incisor inclination in a Le Fort I osteotomy by preoperative and postoperative lateral cephalograms. Materials and Methods: Twenty patients who had undergone orthognathic surgery in Dong-A University Medical Center participated in this study. Lateral cephalometrics, within 3 weeks prior to surgery and 3 days after surgery, were used for analysis. Pre and postoperative measurements of the occlusal plane angle and incisal inclination based on the Frankfort horizontal (FH) plane were performed. X and Y were defined as the amount of vertical change in the upper incisor tip and the amount of vertical change in the upper first molar mesial cup tip through the operation. The amount of final posterior maxillary impaction was determined by subtracting Y from X, which is the difference in vertical height. According to the amount of posterior maxillary impaction, the change in the occlusal plane angle and incisal inclination was measured. Results: The average posterior maxillary impaction was 2.91 mm and the average change in the occlusal plane angle and incisal inclination was $6.54^{\circ}$after surgery. As a result, each mm of posterior maxillary impaction changed the occlusal plane angle and incisal inclination by $2.25^{\circ}$. Statistically, there was high significance. Two cases were observed: one with the same amount of posterior maxillary impaction performed on both the right and left showing $2.20^{\circ}$, and the other with a different amount of posterior maxillary impaction performed showing $2.35^{\circ}$. In this case, there was no significance difference between the two cases. Conclusion: Each mm of posterior maxillary impaction changes the occlusal plane angle and incisal inclination by an average of $2.25^{\circ}$. In posterior maxillary impaction, there was no significant difference in the amount of change in the occlusal plane angle and incisal inclination regardless of whether there was an equal amount of posterior maxillary impaction on both sides. This study is expected to help in the presurgical orthodontic preparation and presurgical treatment planning.

INDIVIDUALIZED IDEAL OCCLUSAL PLANE FOR ORTHOGNATHIC SURGERY AND ORTHODONTIC TREATMENT (PRELIMINARY STUDY) (악교정수술 및 교정치료를 위한 개별화된 이상적인 교합평면에 관한 연구)

  • Hwang, Yun-Jung;Yang, Sang-Duck;Choi, Jin-Young
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.31 no.2
    • /
    • pp.143-148
    • /
    • 2009
  • Introduction: To correct abnormal occlusal plane by orthognathic surgery, we need to have clear criteria for therapeutic occlusal plane. Authors introduced the concept of individualized ideal occlusal plane(Y-plane), which is determined by the size and form of the mandible, and the ideal incisor tip considering upper and lower lip. Authors studied the following to verify if the actual occlusal plane of the patients with optimal jaw relationship corresponds with the individualized ideal occlusal plane. Patients: We reviewed 44 patients who have normal occlusion visitied in the Dept. of orthodontics, Pundang CHA hospital. Methods: We evaluated if there are agreement between individualized ideal occlusal plane(Y plane) and occlusal plane of actual patients. And we confirmed if tested group has a normal face by measuring FABA, FMA, AB-LOP. Results: There were no significant differences of FABA, FMA, AB-LOP, Mo-Y plane between male and female. FABA, FMA and AB-LOP were included in the normal value. Average distance of Mo-Y plane was $0.75{\pm}0.78mm$. Conclusion: Individualized ideal occlusal plane may be applied to orthognathic surgery.

A Study on Feature Extraction of Partial Discharge Type Using Wavelet Transform (웨이블렛변환을 이용한 부분방전 종류의 특징추출에 관한 연구)

  • Park, Jae-Jun
    • The Journal of Information Technology
    • /
    • v.6 no.1
    • /
    • pp.65-70
    • /
    • 2003
  • In this papers, we proposed the new method in order to diagnosis partial discharge type of transformers. For wavelet transform, Daubechie's filter is used,, we can obtain wavelet coefficients which is used to extract featrue of statistical parameters(maximum value, average value, dispersion, skewness, kurtosis) about high frequency current signal per 3-electrode type(needle-plane electrode, IEC electrode and Void electrode). Also, these coefficients are used to identify signal of internal partial discharge in transformer. As a result, from compare of high frequency current signal amplitude and average value, we are obtained results of IEC electrode> Void electrode> Needle-Plane electrode. Otherwise, in case of skewness and kurtosis, we are obtained results of Void electrode> IEC electrode> Needle-Plane electrode. As improved method in order to diagnosis partial discharge type of transformers, we use neural network.

  • PDF

A STUDY ON THE RELATION BETWEEN DELAIRE'S IDEAL OCCLUSAL PLANE AND MASTICATORY MUSCLE ACTIVITY IN KOREAN NORMAL ANGLE CLASS I OCCLUSION INDIVIDUALS (한국성인 정상교합자에서 Delaire의 이상적 교합평면과 저작근 근활성도와의 관계에 대한 연구)

  • Byun, Seong-Kyu;Yi, Choong-Kook
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.26 no.3
    • /
    • pp.229-237
    • /
    • 2000
  • According to the functional matrix theory, Delaire proposes that individual occlusal plane was determined by variable effects of teeth, maxilla, mandible, cranium, cranial base and soft tissue matrix including the orofacial musculature. and that there is the ideal occlusal plane determined by the most proper spatial position of maxilla and mandible, functionally and esthetically. This study was designed to find out the relation between Delaire's ideal occlusal plane and muscle activity of masticatory muscles in individuals who have normal maxillo-mandibular relationships. Lateral cephalometric radiographs were taken and his/her individual occlusal plane and ideal occlusal plane were analyzed with Delaire's architectural and structural craniofacial analytic method. For evaluation of muscle activities of masticatory muscles, electromyography of anterior temporal muscle, superficial masseter muscle, and anterior belly of digastric muscle was recorded in fifty Korean normal Angle class I occlusion individuals. According to the average value of ideal occlusal plane, fifty normal Angle class I occlusion individuals were classified into three groups: Ideal occlusal plane group(I group), hyperrotation group(I+ group) and hyporotation group(I- group). The result of this study was as follows: 1. The results of Delaire's architectural and structural craniofacial analysis of lateral cephalography of the fifty Korean normal Angle class I occlusion individuals are that twelve persons(24%) have consistent or parallel with ideal occlusal plane and the average of angular difference was $1.22^{\circ}{\pm}3.69^{\circ}$. 2. There is no significant difference in muscle activities of masticatory muscles during resting(p<0.05), but significant increases of muscle activity of ipsilateral anterior temporal and masseter muscle, contralateral anterior belly of digastric muscle during unilateral chewing and of anterior temporal and masseter muscle during bilateral clenching(p<0.05). 3. To find out the effect of the angular difference between Delaire's ideal occlusal plane and real occlusal plane to muscle activity, muscle activities of masticatory muscles were compared with three groups in each other; I group, I+ group and I- group. The results were no significant differences during resting, unilateral chewing and bilateral clenching.(p>0.05) 4. Although there is no significant differences of masticatory muscle activities among the three groups, the fact that increasing tendency of masseter muscle activity of ideal occlusal plane group(I+) than those of any other groups(I+ and I-) during bilateral clenching was noted. There is only the implication that occlusal plane makes some effects on masticatory muscle activities, espacially that of masseter muscle during bilateral clenching. In conclusion, the hypothesis that occlusal plane is one of the factors which affect the muscle activities of masticatory muscles and that anyone whose occlusal plane consistent with Delaire's ideal occlusal plane has an extraordinary functional advantage in masticatory muscle function cannot be proven with electromyography methods.

  • PDF