• Title/Summary/Keyword: average discharge

Search Result 734, Processing Time 0.037 seconds

Dependence of needle tip Curvature of the Inception Stress and Propagation of electrical tree (침전극의 곡율반경에 따른 트리개시전계 및 트리진전 특성)

  • 박영국;김완수;이홍규;이용희;임기조
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1999.11a
    • /
    • pp.59-62
    • /
    • 1999
  • Inception and propagation of electrical tree and properties of Partial discharge(PD) pulses accompanying with tree as a function of needle tip radius in low density polyethylene were discussed. To study on these characteristics in different tip radius, we used specimens with needle-plane electrode system made of LDPE, observed inception and propagation of electrical tree by optical microscope with computer and investigated the characteristics of the phase resolved PD pulses accompanying with propagation of electrical tree. The PD quantities detected and analysed were PD magnitude, mean phase angle, average discharge, and the statistical characteristics of the PD pulses. As the tip radius ${\gamma}$ increases, tree inception stress E$\sub$i/ converges to constance value. This result suggests that tree inception stress E$\sub$i/ increases due to stress relaxation when the tip radius is small. Branch-type electrical tree was formed When E$\sub$i/ is 640-750[kV/mm]. bush-type electrical tree when E$\sub$i/ is 370∼400[kV/mm], branch-like electrical tree when E$\sub$i/ is 370-400[kV/mm].

  • PDF

Measurement of the Time Taken for Initial Water Discharge According to the Number of Kinks in the Fire Hose of the Indoor Hydrant System

  • Hong, Suk-Hwan;Kong, Ha-Sung
    • International Journal of Advanced Culture Technology
    • /
    • v.9 no.3
    • /
    • pp.360-366
    • /
    • 2021
  • In this study, we tried to examine how the kinking of the fire hose affects the time taken for initial water discharge by measuring and analyzing the time taken for initial water discharge with different number of kinks at different locations of the hose. The average time taken for initial water discharge was obtained by measuring the time in the unkinked state of the fire hose. Based on this standard, we conducted the experiment by selecting the kinking locations in the hose near the water outlet and nozzle, and setting the number of kinks to 3, 6, 9, and 12. The results of this study are as follows: First, if the fire hose has 5 kinks or more near the nozzle, no water was released. Second, when comparing the case of no kinks and 4 kinks near the nozzle, there was no significant difference in the time taken for initial water discharge. Third, when the fire hose was kinked 10 times near the outlet, the time required for initial water discharge increased by 1.62 seconds on average compared to the case with no kinking, but there was no problem with water discharge. Lastly, regarding the kinking locations of the fire hose, it was found that the greater the number of kinks near the nozzle than near the outlet, the greater the effect on the discharge. As a result, it is concluded that it would be preferable to install non-kinking devices near the nozzle of the fire hose.

A Study on Signal Feature Extraction of Partial Discharge Types Using Discrete Wavelet Transform Technique (이산웨이블렛 변환기법을 이용한 부분방전종류의 신호특징추출에 관한연구)

  • Park, Jae-Jun;Jeon, Byung-Hoon;Kim, Jin-Seong;Jeon, Hyun-Gu;Baek, Kwan-Hyun
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.05c
    • /
    • pp.170-176
    • /
    • 2002
  • In this papers, we proposed the feature extraction method due to partial discharge type of transformers. For wavelet transform, Daubechie's filter is used, we can obtain wavelet coefficients which is used to extract feature of statistical parameters (maximum value, average value, dispersion, skewness, kurtosis) about acoustic emission signal generated from each partial discharge type. The defects which could occur in a transformer were simulated by using needle-plane electrode, IEC electrode and Void electrode. Also, these coefficients are used to identify signal of partial discharge type electrode fault in transformer. As a result, from compare of acoustic emission amplitude and acoustic average value, we are obtained results of IEC electrode> Void electrode> Needle-Plane electrode. otherwise, In case of skewness and kurtosis, we are obtained results of Needle-Plane electrode electrode> Void electrode> IEC electrode.

  • PDF

Reservoir Sedimentations of the Enclosure of Estuary Barraye in Gumgang Basin (하구언 설치에 따른 하천유사량 변화에 관한 연구)

  • 이중기
    • Water for future
    • /
    • v.9 no.1
    • /
    • pp.86-100
    • /
    • 1976
  • To study influences on the downstream, and the Gunsan harbor by setting up estuary of the Gumgang, available data which were collected from the measuring stations which were established within the river basin of which results attained are as follows: 1. The discharge can be calculated as the relationship between the discharge and precipitation in the basin is $R=4{\times}10^{-4}p^2$ or R=P-600 2. The discharge flow in to small resevoirs in the basin can be estimated as $QR=QS\frac{PR-600}{PS-600}(\frac{AR}{AS})$ 3. This daily average discharge at Kongju is 31% less than the during maximum probable discharge and that in Okcheon is 48% less than the daily maximum probable flood. 4. The maximum probable flood from the small stream in the basin can be estimated by a $Q=82.45A^{0{\cdot}464}$ 5. Sediments can be computed with Qs (suspended load)=1.41 $Q^{1{\cdot}42}$ and Qb (bed load)=165.2 $Q^{0{\cdot}705}$. 6. By setting up the specific estuary the tidal movement will be reduced to 93.6% on the average and the sedimentation is reduced to 96.0%. Upon review of overall analysis, the dead wate level of estuary of Gumgang will completely sedimented in next 30 years, therefore, the dredging work at Gunsan harbor is reduced to 73.6%, it is considered that life length will be extended about 52years taking account the existing condition.

  • PDF

The surface discharge performance of silicone rubber in the Salt fog test (Salt fog 시험에서 silicone rubber에서 발생하는 방전 전류의 특성)

  • 강성화;박영국;이광우;김완수;이용회
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1999.05a
    • /
    • pp.565-569
    • /
    • 1999
  • In these days, the silicone insulators have been increasingly studied and applied for outdoor insulators because it has superior characteristics than porcelain and glass insulators, which have been used for outdoor insulators. First of all, The excellent performance of the silicone rubber in polluted and wet conditions is attributed to the ability of the material to maintain the hydrophobicity of the surface in the presence of severe contamination and wet conditions. This is because of the presence of low molecular weight mobile fluid in the silicone rubber which diffuses to the surface and to above the contamination layer. But, the leakage current and some surface discharge occurs on surface of the composite polymeric insulation materials when the insulator is used for a long time with severe contaminative condition and it can lead the contamination flashover. So the leakage current and the discharge current are important to estimate the condition of the silicone rubber surface. In this paper, the average leakage current, the relation of surface discharge current and phase angle were study to investigate electrical conduction of silicone rubber surface with the salt fog condition.

  • PDF

PD Occurrence Characteristics according to Voltage and Time in Solid Insulator

  • Park, Sung-Hee;Shin, Dal-Woo;Lim, Kee-Joe;Park, Young-Guk;Kang, Sung-Hwa
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • v.3C no.1
    • /
    • pp.10-14
    • /
    • 2003
  • The occurrence of partial discharge (PD) in solid dielectrics is very harmful because it leads to the deterioration of insulation by electrical, chemical, and thermal reactions as a combined action of the discharged ions bombarding the surface and by the action of chemical compounds that are formed by the discharge. Consequently, if any defects are present in the solid insulation system, performance decreases until the system breaks down. Therefore, removing or suppressing the defect is very important. Voids are a typical defect in the solid insulation system and are very harmful because they deteriorate insulation. As a basic step, studying the properties of PD in voids is important because an accurate knowledge of these properties is required to estimate the deterioration of voids. In this paper, the correlation between the size of voids and internal PD is discussed as a function of the time of the applied voltage and its magnitude. Magnitude, repetition rate, average discharge power, and average discharge current of PD in specimens with large voids were found to be larger than the others in this experiment. The smaller specimens had voids when the magnitude and number of PDs were reduced.

Design and Analysis of a Battery Charge and Discharge Regulator of Communication Satellite (통신위성 배터리 충,방전기 설계 및 해석)

  • Choe,Jae-Dong
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.31 no.7
    • /
    • pp.118-126
    • /
    • 2003
  • In this study, a battery charge and discharge regulator of modular type is designed as paralleled bi-directional converter that is possible to provide the power without failure not only in the steady state but also in the transient period by the step load variation or the unexpected faults among the converter modules. Each converter module is designed to get stability, performance, reliability, and maintainability and the average current mode method used for controller has the advantages such as noise immunity, fast response, and the real average current signal acquisition. The equivalent model and small signal model for the paralleled battery chargerIdischarger are presented, and also the transfer functions are analyzed for the CCM(Continuous Charge Mode), CDM(Continuous Discharge Mode) and DDM(Discontinuous Discharge Mode). The experiments of the paralleled bi-directional converter are carried out in the step load variation, and in faults of one converter module respectively. And the performance of paralleled bi-directional converter is verified via the experimental results.

Water Resources Utilization Pattern of JangSung Reservoir (장성호 수자원 이용 패턴)

  • Yoon, Kwang-Sik;Han, Kuk-Heon;Yoon, Suk-Gun;Jung, Jae-Woon
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 2003.10a
    • /
    • pp.291-294
    • /
    • 2003
  • The Water resources utilization pattern of Jangsung reservoir was studied. The observed precipitation and existing reservoir operation data such as irrigation amount, reservoir storage, river maintenance requirement, flood control discharge were collected for ten years period and analyzed. Major findings of this study are as follows: The observed average, minimum, maximum annual precipitation were 905.1mm, 1,977.3mm, 1,554.3mm during study period, respectively. The average annual irrigation amount was 554.5mm, irrigation amount of drought years of '92 and '94 was 604.6mm, 679.2mm, respectively. However, irrigation amount of extended drought year '95 was 384.9mm. It showed that supplying capacity of Jangsung reservoir was limited when consecutive 2 year drought occurred. The main water resources usage of Jangsung reservoir was irrigation, but flood control discharge exceed irrigation amount exceptionally when high precipitation occurred. The reservoir operation record revealed that discharge for river maintenance was delivered even drought years.

  • PDF

Reliability Evaluation of STD-11 Cutting Surface on the Machined Condition using the Back-Propagation Neural Network (역전파 신경회로망을 이용한 가공조건에 따른 STD-11 절단면의 신뢰성 평가)

  • Kim Sun-Jin;Sung Back-Sub;Cho Gyu-Jae;Kim Ha-Sik;Ban Jae-Sam
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.13 no.5
    • /
    • pp.7-15
    • /
    • 2004
  • The purpose of this study was to present the method to choose the optimum machining condition for the wire EDM. This was completed by examining the ever-changing quality of the material and by improving the function of the wire electric discharge machine. Precision metal mold products and the unmanned wire electric discharge machining system were used and then applied in industrial fields. This experiment uses the wire electric discharge machine with brass wire electrode of 0.25mm. To measure the precision of the machining surface, average values are obtained from 3 samples of measures of center-line average roughness by using a third dimension gauge and a stylus surface roughness gauge.

A Study on Discharge Statistics Quantities for Deterioration Diagnosis of Branch-type Tree (가지형 트리의 열화진단을 위한 방전통계량에 관한 연구)

  • Shin, S.K.;Kim, K.M.;Kim, T.Y.;Lee, D.J.;Park, C.O.;Kim, J.H.
    • Proceedings of the KIEE Conference
    • /
    • 1999.07e
    • /
    • pp.2345-2348
    • /
    • 1999
  • Existing $\psi$-AEA-t (phase-AEA-time) characteristic in polymer materials for power cable is good in general deterioration characteristic according to time variation, but it is difficult to clearly distinguish from deterioration state and diagnosis of deterioration is not enough to some extent. This paper is interpreted AE discharge statistics quantities measuring phase-amplitude variation of acoustic emission characteristic obtained from treeing breakdown experiment. Besides it can know useful discharge statistics quantities (AE average inception phase/amplitude, AE average maximum phase/amplitude) about so many for diagnosis of treeing deterioration.