• Title/Summary/Keyword: average discharge

Search Result 734, Processing Time 0.033 seconds

Features of Nickel Nanoparticles Structure Synthesized by the Spark Discharge Method

  • Rhee, C.K.;Maksimov, A.D.;Beketov, I.V.;Medvedev, A.I.;Murzakaev, A.M.
    • Journal of Powder Materials
    • /
    • v.27 no.6
    • /
    • pp.464-467
    • /
    • 2020
  • Nickel nanopowders are obtained by the spark discharge method, which is based on the evaporation of the electrode surface under the action of the discharge current, followed by vapor condensation and the formation of nanoparticles. Nickel electrodes with a purity of 99.99% are used to synthesize the nickel nanoparticles in the setup. Nitrogen is used as the carrier gas with a purity of 99.998%. XRD, TEM, and EDX analyses of the nanopowders are performed. Moreover, HRTEM images with measured interplanar spacings are obtained. In the nickel nanopowder samples, a phase of approximately 90 wt% with an expanded crystal lattice of 6.5% on average is found. The results indicate an unusual process of nickel nanoparticle formation when the spark discharge method is employed.

Removal Efficiency of Heavy Metals in Acidic Mine Drainage from Microbial Mats (바이오매트 형성에 의한 산성광산배수 내 중금속 유출질량 제거효율)

  • Yu, Hun-Sun;Kwon, Byung-Hyuk;Kim, Park-Sa;So, Yoon-Hwan;Kang, Dong-Hwan
    • Journal of Environmental Science International
    • /
    • v.21 no.6
    • /
    • pp.667-676
    • /
    • 2012
  • This research investigated to reduce mass of heavy metals in AMD(acid mine drainage) by microbial mats formed on the channel bed. As, Cd, Cu, Fe, Mn and Zn components were monitored in water and microbial mats, at three points (AMD1, AMD2 and AMD3), in a total of six times. Average daily discharge mass of heavy metals was highest in July, Fe component contained more than 76% of total discharge mass. Discharge mass of heavy metals of AMD and heavy metal contents in microbial mats decreased with downstream at channel. Heavy metal components that average daily discharge mass is over 0.5 kg were Fe, Cu and Zn, and they were highest in July. Average removal efficiency of heavy metals in AMD was highest about 21% in Fe, this microbial mats were due to form from precipitation of Fe component in AMD by aerobic iron bacteria. Relative content for As component in microbial mats than AMD was over 16 times, this As components were due to absorb at iron oxide and iron hydroxide on the surface of microbial mats.

Seasonal Variation Estimation of Inflow Pollutant Loads of Yeong-il Bay by using Tank Model (Tank모델에 의한 영일만 유입오염부하량의 계절변동 예측)

  • Lee In-Cheol
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.6 no.3
    • /
    • pp.63-71
    • /
    • 2003
  • This study investigated about the seasonal variation of pollutant loads flowing into the Yeong-il bay from constructing Tank model which is the simulation model to evaluate the daily river discharge and pollutant load in the Hyeong-san river watershed. The estimated annual average river discharge of Hyeong-san river flowing into Yeong-il bay is about 878.34×10/sup 6/㎥/year which is about 73% of annual average of total precipitation in Hyeong-san river watershed. The annual average of pollutant load flowing into Yeong-il bay was estimated each 15.11 ton-COD/year, 23.24 ton-SS/year, 10.65 ton-TN/year, and 0.54 ton-Tp/year. For the seasonal variation of pollutant loads, it was tended as increasing of river discharge as increasing of inflow pollutant loads at June and July of summer and October of autumn. The main source of pollutant loads was found to be the Pohang city and Pohang industrial complex which are located near the mouth of Hyeong-san river. Therefore, for effective water quality management of Yeong-il bay, the counterplan to reduce pollutant loads from the main source of pollutant loads is required.

  • PDF

Experimental Investigation on the Change of Water Discharge Capability of Sluice Caisson for Tidal Power Plant Placed on the Rubble Mound (사석마운드 위에 설치되는 조력발전용 수문 케이슨의 통수성능에 대한 실험적 연구)

  • Lee, Dal-Soo;Oh, Sang-Ho;Lee, Jin-Hak;Park, Woo-Sun;Cho, Hyu-Sang;Eum, Hyun-Min
    • New & Renewable Energy
    • /
    • v.4 no.2
    • /
    • pp.94-104
    • /
    • 2008
  • The change of water discharge capability of sluice caisson for tidal power plant according to installation of the rubble mound was investigated by performing laboratory experiment. The experiment was carried out in an open channel flume with a great care to measure flow rate and water level in the flume accurately. Eight different sluice caisson models were used in the experiment. The water discharge capabilities of seven sluice models decreased with respect to the placement of the rubble mound, while increased for only one sluice model. On average, the values of discharge coefficient decreased by approximately 10% when the sluice models were placed on the rubble mound. It is concluded that the shape of the rubble mound can affect the water discharge capability of the sluice caisson, so that its shape should be significantly considered in the design of the sluice caisson, especially when it is deployed in a site of relatively deeper depth.

  • PDF

Ozone Generation Characteristics in Dielectric Barrier Discharge (유전체 장벽 방전내에서 오존발생 특성)

  • Lee, Hyeong-Ho;Jo, Guk-Hui;Kim, Yeong-Bae;Seo, Gil-Su
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.49 no.12
    • /
    • pp.673-678
    • /
    • 2000
  • The dielectric barrier discharge(DBD) is a common method to create a nonthermal plasma in which electrical energy is used to create electrons with a high average kinetic energy. The unique aspect of dielectric barrier discharges is the large array of short lifetime(10ns) silent discharges created over the surface of the dielectric. A silent discharge is generated when the applied voltage exceeds the breakdown voltage of the carrier gas creating a conduction path between the applied electrode and grounded electrode. As charge accumulates on the dielectric, the electric field is reduced below the breakdown field of the carrier gas and the silent discharge self terminates preventing the DBD cell from producing a thermal arc. In fact, the most significant application of dielectric barrier discharges is to generate ozone for contaminated water treatment. Therefore, experiments were perfomed at 1∼2[bar] pressure using a coaxial geometry single dielectric barrier discharge for ozone concentrations and energy densities. The main result show that the concentration and efficiency of ozone are influenced by gas nature, gas quantity, gas pressure, supplied voltage and frequency.

  • PDF

Effect of Reference Current and Depth of Cut on Electro-Discharge Energy in Electro-Discharge Truing Process for Metal-Bonded Grinding Wheel (금속결합제 연삭숫돌의 방전트루잉에서 기준전류와 절입깊이가 방전에너지에 미치는 영향)

  • Shin, Gun-Hwi;Kwak, Tae-Soo;Jung, Myung-Won;Kwak, Ihn-Sil
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.33 no.6
    • /
    • pp.485-490
    • /
    • 2016
  • This study focused on developing an electro-discharge truing method for the ELID grinding process using a metal-bonded grinding wheel. The truing process in grinding plays important roles in enhancing the quality of the ground surface. In this study, a reference current in the electro-discharge truing process was confirmed to be a viable solution for efficient truing through performance experiments. Current and voltage variation experiments were carried out and the variation output data were collected with a monitoring program to understand the electrodischarge phenomenon that occurs between metal-bonded grinding wheels and copper electrodes. The experimental results showed that as the reference current decreased, the average electro-discharge energy decreased. Therefore, the reference current can be used as an indicator to estimate the size of the gap between the truer and grinding wheel.

Classification Technique of Kaolin Contaminants Degree for Polymer Insulator using Electromagnetic Wave (방사전자파를 이용한 고분자애자의 오손량 분류기법)

  • Park Jae-Jun
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.19 no.2
    • /
    • pp.162-168
    • /
    • 2006
  • Recently, diagnosis techniques have been investigated to detect a Partial Discharge associated with a dielectric material defect in a high voltage electrical apparatus, However, the properties of detection technique of Partial Discharge aren't completely understood because the physical process of Partial Discharge. Therefore, this paper analyzes the process on surface discharge of polymer insulator using wavelet transform. Wavelet transform provides a direct quantitative measure of spectral content in the time~frequency domain. As it is important to develop a non-contact method for detecting the kaolin contamination degree, this research analyzes the electromagnetic waves emitted from Partial Discharge using wavelet transform. This result experimentally shows the process of Partial Discharge as a two-dimensional distribution in the time-frequency domain. Feature extraction parameter namely, maximum and average of wavelet coefficients values, wavelet coefficients value at the point of $95\%$ in a histogram and number of maximum wavelet coefficient have used electromagnetic wave signals as input signals in the preprocessing process of neural networks in order to identify kaolin contamination rates. As result, root sum square error was produced by the test with a learning of neural networks obtained 0.00828.

The method of period division and range setting for annual river discharge management (연중 하천유량 관리를 위한 기간 구분 및 관리범위 설정 방안)

  • Park, Tae Sun
    • Journal of Korea Water Resources Association
    • /
    • v.56 no.1
    • /
    • pp.1-9
    • /
    • 2023
  • Until now, the periods of river discharge management throughout a year are divided into flood and non-flood periods, and the ranges of discharges to be managed are broadly defined from drought discharge to flood discharge. In this study, using the long-term daily discharge data from 8 points of four major rivers, we propose a method of dividing the year into several periods with the homogeneous mean and dispersion of discharges. As a result of the study, the period of through a year was different depending on the point, but it could be divided into pre-flood period, flood period, and post-flood period. And the more subdivided the period, the more decreased the ratio of the maximum discharge to the minimum discharge. In addition, in order to ensure that the discharge for a year is more than the drought discharge and less than the flood discharge, to set the range of discharge management per period as the average flow ± standard deviation for each period is proposed.

Investigation of Fiber Distribution in Concrete Batches Discharged from Ready-Mix Truck

  • Sorensen, Christian;Berge, Egil;Nikolaisen, Eirik B.
    • International Journal of Concrete Structures and Materials
    • /
    • v.8 no.4
    • /
    • pp.279-287
    • /
    • 2014
  • This paper presents the findings of an investigation of the fiber content variations in concrete being discharged from a ready-mix truck at the construction site. Concrete samples were extracted from the truck drums at the beginning, middle and end of discharge. Subsequently, fibers in each sample were separated from the concrete, and weighed. Presumably, synthetic macro fibers will float towards the top, i.e. towards the drum opening, of the inclined, revolving truck-drum, while, on the other hand, steel fibers will tend to gravitate towards the lower parts of the mixer drum. Accordingly, the discharge batch, containing synthetic macro fibers, will contain a higher amount of synthetic fibers per unit volume at the start of discharge than the average unit volume fiber content of the mix, and the content will gradually decrease further down the batch. The discharge batch of steel fiber concrete will contain fewer fibers per unit volume at the start of discharge than the average unit volume fiber content of the mix, and the content should gradually increase further down the batch. The correctness of the foregoing is partly confirmed. A certain percentage of the truck loads did not comply with the proposed requirements, mainly steel fiber reinforced batches, indicating the necessity of a code or guideline amendment. A change in the Norwegian shotcrete directive was made in 2011, based upon experimental research work (2010), which, in combination with the subsequent University of Life Sciences report (2012), constitutes the foundation of this article.

A Study on the Discharge Pressure Ripple Characteristics of Variable Displacement Vane Pump (가변용량형 유압 베인펌프의 토출압력맥동 특성 연구)

  • 장주섭;김경훈
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.11 no.3
    • /
    • pp.106-114
    • /
    • 2003
  • The pressure ripple in the delivery port is caused by flow ripple, which is induced by variation of pumping chamber volume. The other reason is the reverse flow from the outlet volume produced by pressure difference between pumping chamber and outlet volume, when the pumping chamber is connected with the outlet volume. In this study, a mathematical model is presented for analyzing discharge pressure ripple, which includes vane detachment, cam ring movement , and fluid inertia effects in V-groove in the side plate. From the analysis and experiment, it was found that V-groove on the side plate, coefficient of spring supporting the cam ring, and average discharge pressure are the main factors of discharge pressure ripple in variable displacement vane pump. The theoretical results, provided in this study, were well agreed with experimental results. The analytical model to estimate the magnitude of pressure ripple in this study is expected to be used f3r the optimal design of the variable displacement vane pump.