• Title/Summary/Keyword: average concentration

Search Result 4,055, Processing Time 0.032 seconds

Comparative Study of Exposure Assessment of Dust in Building Materials Enterprises Using ART and Monte Carlo

  • Wei Jiang;Zonghao Wu;Mengqi Zhang;Haoguang Zhang
    • Safety and Health at Work
    • /
    • v.15 no.1
    • /
    • pp.33-41
    • /
    • 2024
  • Background: Dust generated during the processing of building materials enterprises can pose a serious health risk. The study aimed to compare and analyze the results of ART and the Monte Carlo model for the dust exposure assessment in building materials enterprises, to derive the application scope of the two models. Methods: First, ART and the Monte Carlo model were used to assess the exposure to dust in each of the 15 building materials enterprises. Then, a comparative analysis of the exposure assessment results was conducted. Finally, the model factors were analyzed using correlation analysis and the scope of application of the models was determined. Results: The results show that ART is mainly influenced by four factors, namely, localized controls, segregation, dispersion, surface contamination, and fugitive emissions, and applies to scenarios where the workplace information of the building materials enterprises is specific and the average dust concentration is greater than or equal to 1.5 mg/m3. The Monte Carlo model is mainly influenced by the dust concentration in the workplace of building materials enterprises and is suitable for scenarios where the dust concentration in the workplace of the building materials enterprises is relatively uniform and the average dust concentration is less than or equal to 6mg/m3. Conclusion: ART is most accurate when workplace information is specific and average dust concentration is > 1.5 mg/m3; whereas, The Monte Carlo model is the best when dust concentration is homogeneous and average dust concentration is < 6 mg/m3.

Measurement Study at Korean, Cheju Island during March-April, 1994: (II) Characteristics of Gaseous Air Pollutants (고산에서의 1994년 3월 - 4월 측정연구: (II) 기체상 대기오염물질의 특성)

  • 김용표;김진영;박세옥;김성주;심상규;문길주;박경윤;허철구
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.12 no.1
    • /
    • pp.91-99
    • /
    • 1996
  • Ozone, sulfur dioxide, and nitrogen oxides were measured at Kosan, Cheju Island, Korea during the period of March 11 .sim. April 19, 1994. During the measurement period, the average SO$_{2}$ and NOx concentrations were about 0.97 ppb and 3.5 ppb, respectively. Average NO concentration was below the detection limit and thus the effect of NO during the period was negligible. The concentrations of SO$_{2}$ and Nox were lower than those at other urban area in Korea but higher than other remote areas in the world. Average $O_{3}$ concentration for the period was about 55 ppb, slightly higher than or comparable to those at remote marine areas in the world. Detailed analyses of trend of gaseous species concentrations show that the effects of local NO emission sources for NOx concentration were significant during the period, while those of local SO$_{2}$ emission sources were not high. Backward trajectory analysis results show that when SO$_{2}$ or $O_{3}$ concentration was higher than the average concentrations, the air parcels were transported from China.

  • PDF

Experimental Study on Two-Phase Flow Parameters of Subcoolet Boiling in Inclined Annulus

  • Lee, Tae-Ho;Kim, Moon-Oh;Park, Goon-Cherl
    • Nuclear Engineering and Technology
    • /
    • v.31 no.1
    • /
    • pp.29-48
    • /
    • 1999
  • Local two-phase flow parameters of subcooled flow boiling in inclined annulus were measured to investigate the effect of inclination on the internal flow structure. Two-conductivity probe technique was applied to measure local gas phasic parameters, including void fraction, vapor bubble frequency, chord length, vapor bubble velocity and interfacial area concentration. Local liquid velocity was measured by Pilot tube. Experiments were conducted for three angles of inclination; 0$^{\circ}$(vertical), 30$^{\circ}$, 60$^{\circ}$. The system pressure was maintained at atmospheric pressure. The range of average void fraction was up to 10% and the average liquid superficial velocities were less than 1.3 m/sec. The results of experiments showed that the distributions of two-phase How parameters were influenced by the angle of channel inclination. Especially, the void fraction and chord length distributions were strongly affected by the increase of inclination angle, and flow pattern transition to slug flow was observed depending on the How conditions. The profiles of vapor velocity, liquid velocity and interfacial area concentration were found to be affected by the non-symmetric bubble size distribution in inclined channel. Using the measured distributions of local phasic parameters, an analysis for predicting average void fraction was performed based on the drift flux model and flowing volumetric concentration. And it was demonstrated that the average void fraction can be more appropriately presented in terms of flowing volumetric concentration.

  • PDF

A Study on the Radon Concentration in the Office (사무실 내 라돈 농도에 관한 연구)

  • Choi, Hyun Woo;Kim, Chi-Nyon;Won, Jong-Uk;Kim, Hong-Kwan;Roh, Jaehoon
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.26 no.3
    • /
    • pp.334-341
    • /
    • 2016
  • Objectives: This study is aimed at examining radon exposure in offices and the factors that can influence the concentrations. Methods: Indoor radon concentrations in a total of 30 places were measured from January 18 to 21, 2016, targeting six buildings in Seoul with different completion years. The measurement was conducted according to the radon measurement guidelines for indoor air suggested by the Ministry of Environment. Results: As a result of comparing each average concentration, underground area concentration was $42.850{\pm}22.501Bq/m^3$, and that of the ground floors was $27.850{\pm}12.232Bq/m^3$, which was lower than the concentration in the underground areas and statistically significant (p=0.045). As a result of comparing the concentration according to whether or not outside air entered, the average concentration for ventilated areas was $24.876{\pm}11.833Bq/m^3$, and the average concentration for enclosed areas was $47.892{\pm}19.375Bq/m^3$. The concentration in ventilated areas was lower at a statistically significant level (p=0.001). Finally, as a result of the multiple regression analysis for evaluating the factors influencing radon concentration, only ventilation was significant (p=0.007). Conclusions: As a result of measuring radon in office buildings, there was no place that exceeding the recommended standard of the US EPA, but the concentration in poorly ventilated areas was measured to be high. An effort to manage radon concentration and reduce it through the improvement of ventilation systems, repeated measurement is necessary in the future.

The Concentration of TSP and Heavy Metals in the Indoor Air of Local PC Rooms (지방 일개도시 PC방에서의 실내공기중 TSP농도와 TSP내 중금속 농도)

  • Cha Hyun Su
    • Journal of Korean Public Health Nursing
    • /
    • v.16 no.1
    • /
    • pp.190-200
    • /
    • 2002
  • This study was carried out to investigate and analyze TSP of the PC rooms. The concentration of the total suspended particulate and heavy metals contained in the total suspended particulate of the 15 PC rooms located in one local city were measured. The statistical correlation coefficients between the total suspended particulate and factors of the indoor condition (number of fan or size of pc room, illumination), between the heavy metals and factors of the indoor condition were studied. The results are as follows: 1. The factors of the indoor condition of the 15 PC rooms are as follows. Average illumination was 24 luxes. Average number of computers installed were 37. Average number of the fans was 7. and the size of investigated PC rooms was $139.94m^2$. 2. The mean age of the subjects was 21.8 years old. they $(51.5\%)$ used the 15 pc rooms for fewer than 2 hours per one day. 3. The mean concentration of total suspended particulate (TSP) is lower in the evening ${139.085\;(2.462)\;{\mu}g/m^3}$ than the night ${166.216(2.609){\mu}g/m^3}$. 4. The mean concentration of total suspended particulate was industrial work area) residential area) commercial area. 5. The distribution of heavy metals were indicated as Zn>Cr>Pb>Cd in the indoor air at PC rooms. and the concentration rate of Zn was the highest among heavy metals. but this increase didn't show any relationship with many factors of indoor condition (number of fan or size of pc room, lighting) 6. The concentration of TSP & heavy metals didn't have any relationship between the factors of indoor environment (number of fans, size of pc room, lighting).

  • PDF

A study of particulate matters in Korea (우리나라 일부지역의 입자상 물질 농도에 대한 연구)

  • 손부순;공미연;박종안;양원호;김종오
    • Journal of environmental and Sanitary engineering
    • /
    • v.18 no.4
    • /
    • pp.24-35
    • /
    • 2003
  • Recent epidemiologic studies revealed that the concentration of air pollutants and fine particulated matter have some effects on health status and are associated with increased mortality and morbidity. The purpose of this study was to characterize background mass concentration of fine particle (PM2.5) and metallic composition from September 2001 to August 2002 in comparison with a medium city, Asan and metropolitan city, Seoul. Conclusively, proper management for fine particles was required in a medium city, Asan, considering the concentrations of metallic elements in fine particles in Asan were relatively higher than those in Seoul. The results were as followed. 1. Average mass concentrations of fine particles in Asan and Seoul were 37.70(${\pm}18.41{\;}{\mu}g/\textrm{m}^3$) and 5.83(${\pm}38.50$) ${\mu}g/\textrm{m}^3$, respectively. When the weather conditions were classified as normal and yellow-sand, measured average mass concentrations of fine particles in yellow-sand weather condition was significantly higher than those of normal weather condition in both cities (p<0.05). 2. Depending on seasons, measured average mass concentrations of fine particles in Asan and Seoul in spring were 47.76(${\pm}19.07$) ${\mu}g/\textrm{m}^3$m and 61.53 (${\pm}4.37$) ${\mu}g/\textrm{m}^3$, respectively. In summer, the average mass concentrations of fine particles in Asan and Seoul were 29.44(${\pm}9.85$) ${\mu}g/\textrm{m}^3$ and 25.42(${\pm}8.10$) ${\mu}g/\textrm{m}^3$, respectively. Especially, the concentration was the highest in spring and the lowest in summer among four seasons. 3. Average concentrations of manganese(Mn), iron(Fe), chromium(Cr), cadmium(Cd), lead(Pb) and silicon(Si) in fine particles in Asan were significantly higher in Seoul (p<0.05). Average concentration of Si in fine particle in Asan was statistically higher than that of Seoul during yellow -sand condition (p<0.05). 4. Considering the characterization of four seasons, average Pb concentration of fine particle in Asan is significantly higher than that of Seoul in spring(p<0.01). In summer, average Mn and Cr concentrations of fine particle in Asan is higher than those of Seoul (p<0.05). Average Mn, Fe. Cr and Si concentrations in fall (p<0.05), and average Mn, Fe, Cr, Pb, and Si concentrations in winter (p<0.05) in Asan were higher than those of Seoul, respectively. 5. Mass concentrations of each Mn, Fe, Cd and Si in fine particles were significantly correlated with both cities. In normal weather condition, Mn, Cu and Si concentrations are statistically significant in Asan, while Mn, Fe, Cu and Si concentrations are statistically significant in Seoul. Mn, Fe and Si concentrations in both cities were statistically significant during yellow-sand weather.

A Comparison Study of Ensemble Approach Using WRF/CMAQ Model - The High PM10 Episode in Busan (앙상블 방법에 따른 WRF/CMAQ 수치 모의 결과 비교 연구 - 2013년 부산지역 고농도 PM10 사례)

  • Kim, Taehee;Kim, Yoo-Keun;Shon, Zang-Ho;Jeong, Ju-Hee
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.32 no.5
    • /
    • pp.513-525
    • /
    • 2016
  • To propose an effective ensemble methods in predicting $PM_{10}$ concentration, six experiments were designed by different ensemble average methods (e.g., non-weighted, single weighted, and cluster weighted methods). The single weighted method was calculated the weighted value using both multiple regression analysis and singular value decomposition and the cluster weighted method was estimated the weighted value based on temperature, relative humidity, and wind component using multiple regression analysis. The effects of ensemble average methods were significantly better in weighted average than non-weight. The results of ensemble experiments using weighted average methods were distinguished according to methods calculating the weighted value. The single weighted average method using multiple regression analysis showed the highest accuracy for hourly $PM_{10}$ concentration, and the cluster weighted average method based on relative humidity showed the highest accuracy for daily mean $PM_{10}$ concentration. However, the result of ensemble spread analysis showed better reliability in the single weighted average method than the cluster weighted average method based on relative humidity. Thus, the single weighted average method was the most effective method in this study case.

Treatment Characteristics Using Full-Scale SBR System (Full-Scale SBR 공법을 이용한 처리특성)

  • Choo, Tai-Ho;Lee, Yong-Doo;Cho, Yong-Hyun
    • The Journal of the Korea Contents Association
    • /
    • v.6 no.10
    • /
    • pp.34-40
    • /
    • 2006
  • In this study, the treatment of organic matters and nutrients like Nitrogen and Phosphorus with sequencing batch reactors (SBR) was conducted. The following conclusions can be summarized from the study. The influent BOD concentration was varied 19.6 to 40.0mg/L and the effluent was 3.0 to 14.8mg/L. The variations of BOD removal efficiency during the experimental period was $47.9{\sim}88.4%$ and the average was 80.8%. The average removal efficiency was stabilized with the passage of time. Also the COD concentration was flowed into as $12.2{\sim}32.0mg/L$ and the effluent concentration was varied 3.3 to 18.6 mg/L, and then the average COD removal efficiency was 57.3%(minimun 19.2% and maximum 78.6%). But fortunately, the COD removal efficiency was also stabilized as 70.2% after 79days. In the case of T-N, the influent concentration range was $7.53{\sim}14.99mg/L$ and the effluent concentration was 6.59mg/L(the average removal efficiency was 40.3%) until the first experiment time 79days. But after normalizing the system, it was 4.44mg/L (the average removal efficiency was 56.4%). Also the influent T-P concentration was varied from 0.77 to 1.91mg/L and the effluent concentration was $0.26{\sim}1.53mg/L$. The removal efficiency was varied from 5.3 to 71.7%. considerably, therefore the average removal efficiency was 42.6%. The reason was concluded that the sludge wasn't discharged for increasing MLSS concentration.

  • PDF

Analysis on the Effect of Meteorological Factors related to Difference of Ozone Concentration at the Neighboring Areas in Gijang Busan (인접지역간 오존 농도 차이에 대한 기상요소의 영향분석(부산광역시 기장군을 대상으로))

  • Kim, Min-Kyoung;Lee, Hwa-Woon;Jung, Woo-Sik;Do, Woo-Gon
    • Journal of Environmental Science International
    • /
    • v.21 no.9
    • /
    • pp.1097-1113
    • /
    • 2012
  • Ozone is the secondary photochemical pollutant formed from ozone precursor such as nitrogen dioxide and non-methane volatile organic compounds(VOCs). The ambient concentration of ozone depends on several factors: sunshine intensity, atmospheric convection, the height of the thermal inversion layer, concentrations of nitrogen oxides and VOCs. Busan is located in the southeast coastal area of Korea so the ozone concentration of Busan is mainly affected from the meteorological variables related to the sea such as sea breeze. In this study the ozone concentrations of Busan in 2008~2010 were used to analyse the cause of the regional ozone difference in eastern area of Busan. The average ozone concentration of Youngsuri was highest in Busan however the average ozone concentration of Gijang was equal to the average ozone concentration of Busan in 2008~2010. The two sites are located in eastern area of Busan but the distance of two sites is only 9km. To find the reason for the difference of ozone concentration between Youngsuri and Gijang, the meteorological variables in two sites were analyzed. For the analysis of meteorological variables the atmospheric numerical model WRF(Weather Research and Forecasting) was used at the day of the maximum and minimum difference in the ozone concentration at the two sites. As a result of analysis, when the boundary layer height was lower and the sea breeze was weaker in Youngsuri, the ozone concentration of Youngsuri was high. Furthermore when the sea breeze blew from the south in the eastern area of Busan, the sea breeze at Youngsuri turned into the southeast and the intensity of sea breeze was weaker because of the mountain in the southern region of Youngsuri. In that case, the difference of ozone concentration between Youngsuri and Gijang was considerable.

Environmental Planning Contermeasures Considering Spatial Distribution and Potential Factors of Particulate Matters Concentration (미세먼지 농도의 공간적 현황 및 잠재영향인자를 고려한 환경계획적 대응 방향)

  • Sung, Sun-Yong
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.23 no.1
    • /
    • pp.89-96
    • /
    • 2020
  • Adverse impact of Particulate Matters(PM10, PM2.5; PMs) significantly affects daily lives. Major countermeasures for reducing concentration of PMs were focused on emission source without considering spatial difference of PMs concentration. Thus, this study analyzed spatial·temporal distribution of PMs with observation data as well as potential contributing factors on PMs concentration. The annual average concentration of PMs have been decreased while the particulate matter warnings and alerts were significantly increased in 2018. The average concentration of PMs in spring and winter was higher than the other seasons. Also, the spatial distribution of PMs were also showed seasonality while concentration of PMs were higher in Seoul-metropolitan areas in all seasons. Climate variables, emission source, spatial structure and potential PM sinks were selected major factors which could affects on ambient concentrations of PMs. This paper suggest that countermeasures for mitigating PM concentration should consider characteristics of area. Climatic variables(temperature, pressure, wind speed etc.) affects concentrations of PMs. The effects of spatial structure of cities(terrain, ventilation corridor) and biological sinks(green infrastructure, urban forests) on concentration of PMs should be analyzed in further studies. Also, seasonality of PMs concentration should be considered for establishing effective countermeasures to reduce ambient PMs concentration.