• Title/Summary/Keyword: autostigmatic

Search Result 10, Processing Time 0.031 seconds

Null lens design for testing of elliptical surface (타원면경 측정 Null 렌즈 설계)

  • 김연수
    • Korean Journal of Optics and Photonics
    • /
    • v.11 no.4
    • /
    • pp.246-249
    • /
    • 2000
  • The null lens is designed for testing the elliptical (conic constant>O) mirror which is the third mirror of the off-axis Three Mirror Anastigmat (TMA) designed as a high resolution camera for remote sensing. The mixed type design is proposed as a new design type which has a small annular flat mirror, but has as twice sensitivity as the autostigmatic type design. It is also shown that the null lens of the Mixed type is better than that of the autostigmatic type in terms of the sensitivity of the wavefront distortion which is given as the magnitude of optical path difference with respect to the change of each surface parameters such as the radius of curvature, thickness of lenses and tested mirror.

  • PDF

Evaluation of a Aluminum Hyperbolic Mirror with the Diameter of 300 mm(f/1.98) by Using the Autostigmatic Null Lens System Assembled in a Fixed Tube Mount (경통고정식 자동무수차점 널 렌즈 테스트법을 이용한 직경 300 mm(f/1.98) 알루미늄 쌍곡면 거울의 형상측정)

  • Lee, Young-Hun;Jo, Jae-Heung;Rim, Cheon-Seog;Yang, Sun-Choel;Kim, Geon-Hee;Won, Jong-Ho;Jeong, Youn-Hong
    • Korean Journal of Optics and Photonics
    • /
    • v.17 no.5
    • /
    • pp.412-419
    • /
    • 2006
  • We design and fabricate an autostigmatic null lens system assembled in a fixed tube mount in order to evaluate the shape of an aluminum hyperbolic mirror with the diameter of 300 mm and the f-number of 1.98, which is fabricated by a high precision aspherical DTM (diamond turning machine). Also, we evaluate the degree of shape of the aspherical mirror by this autostigmatic null lens testing method. The autostigmatic null lens system assembling in a fixed tube mount has several advantages of light weight, good mechanical stability, etc. The permissible fabricating limits of null lenses and a mount are determined by considering various tolerances to assure the measurement reliability.

A study for null lens design of autostigmatic type and the limitation of measurement accuracy for ultra precision manufacturing of large aspherical surface (대형 비구면의 초정밀 가공을 위한 자동무수차점 방식의 널 렌즈 설계 및 측정 정밀도의 한계에 관한 연구)

  • Kim, Kil-Seon;Rim, Cheon-Seog
    • Korean Journal of Optics and Photonics
    • /
    • v.16 no.1
    • /
    • pp.71-78
    • /
    • 2005
  • A null lens system of autostigmatic type, consisting of two mirrors, is designed for testing a large aspherical mirror. The system is theoretically analyzed to determine the limitation of measurement accuracy according to the manufacturing and alignment errors. We confirmed that irregularity of the null lens surface is the principal factor among tolerances in limiting measurement accuracy. Consequently, we can predict that measurement accuracy will be from 5λ/100 to 4λ/1000 according to the amount of this irregularity. That is, we can present the limitation of possible measurement accuracy with actual alignment and manufacturing errors.

Design of null lenses for testing of hyperbolic surfaces (쌍곡면 측정 null 렌즈 설계)

  • 김연수;김병윤;이윤우
    • Korean Journal of Optics and Photonics
    • /
    • v.12 no.5
    • /
    • pp.352-355
    • /
    • 2001
  • A null lens is designed for testing the hyperbolic mirror which is the first mirror of the off-axis three mirror anastigmat(TMA) designed as a high resolution camera for remote sensing. To choose a better null lens system for the hyperbolic surface under test, both autostigmatic and mixed type null lenses are designed and analysed for sensitivity with respect to change of each surface parameter such as the radius of curvature and the thickness.

  • PDF

Fabrication Measurement and Evaluation of a Parabolic Mirror with the Diameter of 450 mm(f/2.7) by Autostigmatic Null Lens System (자동무수차점 방식 널 렌즈 광학계를 이용한 직경 450 mm(f/2.7) 포물면경의 제작 및 측정 평가)

  • Lee, Young-Hun;Jo, Jae-Heung;Rim, Cheon-Seog;Lee, Yun-Woo;Yang, Ho-Soon;Lee, Jae-Hyeob;Lee, In-Won
    • Korean Journal of Optics and Photonics
    • /
    • v.17 no.2
    • /
    • pp.165-174
    • /
    • 2006
  • The autotstigmatic null lens system is designed and constructed for the fabrication of a parabolic mirror with the diameter of 450 mm(f/2.7). And the measurement reliability is also analyzed theoretically by means of the tolerancing technique using lens design software(CODE V). From this analysis, we can precisely fabricate a parabolic mirror with the large diameter of 450 mm(f/2.7). Meanwhile, in order to confirm the fabrication results by the autostigmatic method, the mirror surface is tested again by an autocollimating method that uses only a plane mirror without any null lens.

A Study for the Limitation of Measurement Accuracy and Reliability of Autostigmatic Null lens System by Adjustment and Fixing Process (조정방식과 경통고정방식에 대한 자동무수차점 널 렌즈 광학계의 측정 정밀도 한계 및 신뢰도)

  • Lee, Young-Hun;Rim, Cheon-Seog
    • Korean Journal of Optics and Photonics
    • /
    • v.16 no.5
    • /
    • pp.440-445
    • /
    • 2005
  • The limitation of measurement accuracy and reliability of autostigmatic null lens system are studied for the cases of using inter-distance of null lenses as the adjustment factor of alignment and fixing the distance by mounting. If we investigate the first case, the wavefront aberration of null lens system is compensated by the adjustment process even though the shape of aspherical surface is not properly fabricated. As the result, it brings about the problem of measurement reliability. However, for the fixing process by mounting null lenses, it doesn't cause the reliability problem because the wavefront aberration of null lens system is not compensated. Further, the fixing process shows nearly same result in measurement accuracy to the adjustment process, that is, $0.0316{\lambda}$ vs. $0.0326{\lambda}$. So, we can conclude the setup for autostigmatic null lens system must be constituted by means of the fixing process. Meanwhile, we introduce and define the alignment aperture on aspheircal mirror, which can be approximated as spherical zone for alignment of null lens system, and besides, we calculate the required fabrication accuracy of the zone for the necessary measurement accuracy.

GMT 부경 테스트 방법에 관한 연구

  • An, Gi-Beom;Kim, Yeong-Su;Park, Gwi-Jong;Cheon, Mu-Yeong;Jang, Jeong-Gyun;Park, Byeong-Gon;Yuk, In-Su;Gyeong, Jae-Man
    • Bulletin of the Korean Space Science Society
    • /
    • 2009.10a
    • /
    • pp.33.1-33.1
    • /
    • 2009
  • GMT(Giant Magellan Telescope)는 그레고리안(Gregorian) 방식 망원경이다. 일반적으로 그레고리안 방식은 포물면인 주경과 타원면인 부경으로 구성되어 있으나, GMT의 주경은 비구면계수가 -0.99829인 타원면이다. 부경은 지름 1.063m 7장의 반사경이 3.2m의 부경을 이루며 곡률반경은 4.2058m, 비구면계수는 -0.71087이다. 주경과 부경은 모두 1장의 중앙 반사경과 6장의 비축 반사경으로 이루어져 있다. 따라서 GMT 광학계에서 대구경 비축 비구면 반사경의 가공 및 테스트는 매우 중요하다. 이 발표에서는 GMT 부경을 테스트하기 위하여, 타원면의 기본적인 광학적 특성을 이용한 테스트 방법과 이 방법의 단점을 보완하기 위해 Reference 반사경을 이용하는 방법, 그리고 Null compensator를 이용한 방법 등을 제시한다. Null compensator를 이용한 방법에는 일반적으로 Autostigmatic 방식과 Autocollimation 방식이 있으며 이 발표에서는 이 두 방식을 상호 비교한 연구 결과에 대하여 논의한다.

  • PDF

Diffraction grating interferometer for null testing of aspheric surface with binary amplitude CGH (이진 컴퓨터 형성 홀로그램을 이용한 비구면 형상 측정용 위상편이 회절격자 간섭계)

  • 황태준;김승우
    • Korean Journal of Optics and Photonics
    • /
    • v.15 no.4
    • /
    • pp.313-320
    • /
    • 2004
  • We present a null testing method fer aspheric surfaces, utilizing a phase-shifting diffraction grating interferometer along with a binary amplitude computer generated hologram (CGH). The binary amplitude CGH is designed to compensate for the wavefront between a point source and the aspheric surface under test. The fringe visibility of the grating interferometer is controlled easily by selecting suitable grating diffraction orders for the measurement and reference wavefronts or by optimizing the groove shape of the grating used. The binary amplitude CGH is designed by numerical analysis of ray tracing and fabricated using e-beam lithography for autostigmatic testing. Experimental results of a large-scale aspheric mirror surface are discussed to verify the measurement performance of the proposed diffraction grating interferometer.