• 제목/요약/키워드: automatic gamma control system

검색결과 13건 처리시간 0.023초

DSP를 이용한 모바일 TFT-LCD의 자동 감마 최적화 시스템 개발 (Development of Automatic Gamma Optimization System for Mobile TFT-LCD)

  • 조내수;류지열;박철우;권우현
    • 제어로봇시스템학회논문지
    • /
    • 제15권3호
    • /
    • pp.323-329
    • /
    • 2009
  • This paper presents an automatic LCD gamma control system using gamma curve optimization. It controls automatically gamma adjustment registers in mobile LCD driver IC to reduce gamma correction error and adjusting time. The proposed gamma system contains Module-Under-Test (MUT, LCD module), PC installed with program, multimedia display tester for measuring luminance, and control board for interface between PC and LCD module. Proposed algorithm and program are applicable for most of the LCD modules. It is realized to calibrate gamma values of 1.8, 2.0, 2.2 and 3.0. The control board is designed with DSP and FPGA, and it supports various interfaces such as RGB and CPU. Developed automatic gamma control system showed significantly reduced gamma adjusting time of 240 sec. and much less average gamma error of 11% than 42h and 27% with conventional manual method. We believe that the proposed system is very useful to provide high-quality LCD and to improve production process.

모바일 TFT-LCD를 위한 새로운 화질 최적화 시스템 (A New Image Quality Optimization System for Mobile TFT-LCD)

  • 류지열;노석호
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2008년도 춘계종합학술대회 A
    • /
    • pp.734-737
    • /
    • 2008
  • 본 논문은 새로운 형태의 TFT-LCD 자동 화질 최적화 시스템을 제안한다. 또한 참조 감마 곡선과의 6-점 프로그램 정합 기술을 이용한 새로운 알고리즘 및 자동 전압 설정 알고리즘을 제안한다. 이러한 시스템은 평균 감마 오차, 감마 조정 시간 및 플리커 등을 줄이기 위해 모바일 LCD 구동 IC 내의 감마 조정 레지스터들과 전압 설정 레지스터들을 자동적으로 제어한다. 개발된 알고리즘과 프로그램은 범용 LCD 모듈에 적용 가능하다. 제안된 최적 화질 향상 시스템은 측정 대상이 되는 모듈 (MUT, LCD 모듈), 제어 프로그램, 휘도 측정용 멀티미디어 디스플레이 측정기 및 인터페이스용 제어 보드로 구성되어 있다. 제어 보드는 DSP와 FPGA로 구성되어 있고, RGB 및 CPU와 같은 다양한 인터페이스들을 지원한다. 개발된 자동 화질 최적화시스템은 기존의 시스템에 비해 현저히 짧은 감마 조정시간, 적은 플리커 및 적은 평균 감마 오차를 보였다. 본 논문에서 제안하는 시스템은 최적 감마 곡선 및 자동 전압 설정을 이용하기 때문에 개발 공정 시간을 단축시키고, 고화질의 TFT-LCD를 제공하는데 아주 유용하다.

  • PDF

모바일 LCD 응용을 위한 자동 감마 제어 시스템 개발 (Development of Automatic Gamma Control System for mobile LCD Applications)

  • 류지열;노석호
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2007년도 추계종합학술대회
    • /
    • pp.754-757
    • /
    • 2007
  • 본 논문은 감마 곡선 최적화를 이용한 자동 LCD 감마 제어 시스템을 제안한다. 이러한 시스템은 평균 감마 요차와 감마 조정 시간을 줄이기 위해 모바일 LCD 구동 IC 내의 감마 조정 레지스터들을 자동적으로 제어한다. 제안된 감마 시스템은 측정 대상이 되는 모률 (MUT, LCD 모듈), 프로그램화된 개인용 컴퓨터, 휘도 측정용 멀티미디어 디스플레이 측정기 및 퍼스널 컴퓨터와 LCD 모듈간의 인터페이스용 제어 보드로 구성되어 있다. 창조 감마 곡선과의 6-점 프로그램 정합 기술을 이용하여 새로이 개발된 알고리즘을 제안한다. 개발된 알고리즘과 프로그램은 범용 LCD 모듈에 적용가능하다.

  • PDF

모바일 TFT-LCD 응용을 위한 새로운 형태의 자동화질 최적화 시스템 개발 (Development of a New Automatic Image Quality Optimization System for Mobile TFT-LCD Applications)

  • 류지열;노석호
    • 전자공학회논문지SC
    • /
    • 제47권1호
    • /
    • pp.17-28
    • /
    • 2010
  • 본 논문은 DSP를 이용한 새로운 형태의 TFT-LCD 자동 화질 최적화 시스템을 제안한다. 실제 산업 현장에서 이와 같은 화질 최적화 과정은 시행착오를 반복하는 형식으로 진행되어 많은 시간이 소요되고 있으며 LCD 개발 엔지니어들의 성향 및 숙련도에 따라 조정 결과에도 편차가 큰 문제점이 있다. 이러한 시스템은 평균 감마 오차, 감마 조정 시간 및 플리커 등을 줄이기 위해 모바일 LCD 구동 IC 내의 감마 조정 레지스터들과 전압 설정 레지스터들을 자동적으로 제어한다. 제안된 최적 화질 향상 시스템은 측정 대상이 되는 모듈 (MUT, LCD 모듈), 제어 프로그램, 휘도 측정용 멀티미디어 디스플레이 측정기 및 인터페이스용 제어 보드로 구성되어 있다. 개발된 시스템에는 참조 감마 곡선과의 6-점 프로그램 정합 기술을 이용한 새로운 알고리즘 및 자동 전압 설정 알고리즘이 내장되어 있다. 개발된 알고리즘과 프로그램은 범용 LCD 모듈에 적용가능하다. 또한 1.8, 2.0, 2.2 및 3.0 감마를 조정할 뿐만 아니라 플리커 수준을 자동으로 조절한다. 제어 보드는 DSP와 FPGA로 구성되어 있고, RGB 및 CPU와 같은 다양한 인터페이스들을 지원한다. 개발된 자동 감마 시스템은 기존의 시스템에 비해 현저히 짧은 감마 조정 시간 및 아주 작은 평균 감마 오차를 보였다. 또한 본 논문에서 제안하는 시스템은 최적화된 감마 곡선 설정을 이용한 개발 공정을 향상시키고, 고화질의 LCD를 제공하는데 아주 유용하다.

장비정도관리에 Calibrator[I-125] Set 적용 (The Application of New Calibrator[I-125]Set for Equipment Quality Management)

  • 김지나;안재석;원우재
    • 핵의학기술
    • /
    • 제19권2호
    • /
    • pp.108-111
    • /
    • 2015
  • Purpose Lately, in accordance with the increasing interest about Healthcare accreditation program and International laboratory accreditation scheme, requirements about the instrument quality management are gradually taking shape. In nuclear medicine In vitro laboratory, the most typical instruments are multi detector gamma counter and automatic dispensing system. Each laboratory continue with the quality control adequate for circumstances. The purpose of this study is to application and establish the new Calibrator[I-125]Set which is efficient at standardization of equipment quality management. Materials and Methods Deviation between detectors were measured with 12 solid samples of the Calibrator[I-125]Set. their activities differ from each other by less than 1%. Multi detector gamma counters are GAMMA-10;Shinjin medics. Inc, Goyansi, Korea(Gamma counter A), SR300;Stratec biomedical systems AG, Gewerbestr, Germany(Gamma counter B) and COBRA II; Packard Instrument Co. Inc, Meriden, USA(Gamma counter C). Evaluation of two automatic dispensing system used A, B liquid tracer of the Calibrator[I-125]Set. After dispensing and counting, calculated using the ratio of the measured value and proposed value. We used solution A for 20, 25ul and solution B for 50, 100ul. Method of data analysis and reference range was provided by kit documentation. Furthermore, we could calculate our counter efficiency indirectly. Results The CV(%) of measured values by Gamma counter A, B, C are 0.34, 0.70, 1.30. Calculated value are 1.05314, 2.10419, 4.08485. Provided reference range is less than 3. A dispensing system's calculated values are 0.986, 0.989, 1.023, 1.017 and B are 0.874, 0.725, 1.021, 0.904. Provided reference range is from 0.95 to 1.05. Also, counter's efficiency are 74.18, 72.79, 74.32% at counter A, B, C and efficiency of the one detector counter is 79.26%. Conclusion If using this Calibrator[I-125]Set after verifying whether quality assurance, is applicable to equipment quality management on behalf of the role of gold standard.

  • PDF

모바일 TFT-LCD 구동 집적회로를 위한 화질 레지스터 최적화시스템 개발 (Development of Image Quality Register Optimization System for Mobile TFT-LCD Driver IC)

  • 류지열;노석호
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2008년도 추계종합학술대회 B
    • /
    • pp.592-595
    • /
    • 2008
  • 본 논문은 모바일 TFT-LCD 구동 집 회로와 임베디드 소프트웨어를 이용한 자동 화질 레지스터 최적화시스템을 제안한다. 이러한 시스템은 LCD모듈의 중요한 화질 평가 요소인 평균 감마 오차, 감마 조정 시간, 플리커 잡음 및 명암비 등을 최적화하기 위해 모바일 LCD구동 집적회로 내의 감마조정 레지스터들과 전압 설정 레지스터 들을 자동적으로 제어한다. 개발된 알고리즘과 임베디드 소프트웨어는 거의 모든 유형의 LCD모듈에 적용 가능하다. 개발된 화질 최적화 시스템은 측정 대상이 되는 모듈 (MUT, LCD 모듈), 제어 프로그램, 휘도 측정용 멀티미디어 디스플레이 측정기 및 인터페이스용 제어 보드로 구성되어 있다. 제어 보드는 DSP와 FPGA로 구성 되 어 있고, RGB 및 CPU 인터페이스를 지원한다.

  • PDF

사례 기반 지능형 수출통제 시스템 : 설계와 평가 (Export Control System based on Case Based Reasoning: Design and Evaluation)

  • 홍원의;김의현;조신희;김산성;이문용;신동훈
    • 지능정보연구
    • /
    • 제20권3호
    • /
    • pp.109-131
    • /
    • 2014
  • 최근 전 세계적인 원전 설비의 수요 증가로 원자력 전략물자 취급의 중요성이 높아지는 가운데, 국외 수출을 위한 원전 관련 물품 및 기술의 신청 또한 급증하는 추세이다. 전략물자 사전판정 업무는 통상 원자력 물자 관리에 해박한 전문가의 경험 및 지식에 근거하여 수행되어 왔지만, 급증하는 수요에 상응하는 전문 인력의 공급이 부족한 실정이다. 이러한 문제를 극복하기 위하여, 본 연구진은 전략물자 수출 통제를 위한 사례 기반 지능형 수출 통제 시스템을 설계 및 개발하였다. 이 시스템은 현장 전문가의 전담 업무이던 신규 사례에 대한 전략물자 사전판정 과정 업무의 주요 맥락을 자동화 하여 전문가 및 관계 기관이 감당해야 할 업무 부담을 줄이며, 빠르고 정확한 판정을 돕는 의사결정 지원 시스템의 역할을 맡는다. 개발된 시스템은 사례 기반 추론 (Case Based Reasoning) 방식에 기반을 두어 설계되었는데, 이는 과거 사례의 특성을 활용하여 신규 사례의 해법을 유추하는 추론 방법이다. 본 연구에서는 자연어로 작성된 전자문서 처리에 널리 사용되는 텍스트 마이닝 분석 기법을 원자력 분야에 특화된 형태로 응용하여 전략물자 수출통제 시스템을 설계하였다. 시스템 설계의 근거로 선행 연구에서 제안된 반자동식 핵심어 추출 방안의 성능을 보다 엄밀히 검증하였고, 추출된 핵심어로 신규 사례와 유사한 과거 사례를 추출하는 알고리즘을 제안하였다. 제안된 방안은 텍스트 마이닝 분야의 TF-IDF 방법 및 코사인 유사도 점수를 활용한 결과(${\alpha}$)와 원자력 분야에서 통용되는 개념적 지식을 계통으로 분류하여 도출한 결과(${\beta}$)를 조합하여 최종 결과 (${\gamma}$) 를 생성하게 된다. 세부 요소 기술의 성능 검증은 임상 데이터를 활용한 실험 및 실무 전문가의 의견수렴을 통해 이루어졌다. 개발된 시스템은 사전판정 전문 인력을 다수 양성하는 데 드는 비용을 절감하는 데 일조할 것이며, 지식서비스 산업의 의미 있는 응용 사례로서 관련 산업의 성장에 기여할 수 있을 것으로 보인다.

CMOS 이미지 센서를 위한 실시간 전처리 프로세서의 설계 (A Design of the Real-Time Preprocessor for CMOS image sensor)

  • 정윤호;이준환;김재석
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 1999년도 추계종합학술대회 논문집
    • /
    • pp.224-227
    • /
    • 1999
  • This paper presents a design of the real-time preprocessor for CMOS image sensor suitable to the digital camera applications. CMOS image sensor offers some advantages in on-chip integration, system power reduction, and low cost. However, it has a lower-quality image than CCDs. We describe an image enhancement algorithm, which includes color interpolation, color correction, gamma correction, sharpening, and automatic exposure control, to compensate for this disadvantage, and present its efficient hardware architecture to implement on the real-time processor. The presented real-time preprocessor was designed using VHDL, and it contains about 19.2K logic gates. We also implement our system on FPGA chips in order to provide the real-time adjustment and it was successfully tested.

  • PDF

풀칼라 LED 전광판용 고속 데이터처리 제어장치 설계 (Design of high speed data processing controller for the full color LED display board system)

  • 하영재;진병윤;김선형
    • 한국정보통신학회논문지
    • /
    • 제14권2호
    • /
    • pp.462-468
    • /
    • 2010
  • 본 논문에서는 기존의 full color LED 전광판 영상 처리 방식을 개선시킨 획기적인 영상 구동 처리 기술을 제안하였다. 이 기술은 고화질의 대형 TV나 LCD Display에 적용 가능하며 선명한 표출구동의 영상제어를 가능하게 한다. 제안한 구동 제어 방식은 기존의 영상처리 기능을 효율적으로 보강할 수 있다. 자동 또는 수동으로 contrast, bright, tint, color, 감마보정 등의 영상 변화처리 조절이 가능하므로 선명한 화질을 얻을 수 있다. 그리고 경제적인 가격으로 구현이 가능하다.

비파괴검사 분야에서 방사선원의 위치 확인을 위한 산화납 기반 방사선 검출기 설계에 관한 연구 (The Study on Design of lead monoxide based radiation detector for Checking the Position of a Radioactive Source in an NDT)

  • 안기정
    • 한국방사선학회논문지
    • /
    • 제11권4호
    • /
    • pp.183-188
    • /
    • 2017
  • 최근, 감마선 조사기의 자동 원격 조사 제어기가 오동작하여 방사선작업종사자가 방사선 피폭 사고가 지속적으로 보고되고 있다. 이에 NDT 분야에서는 방사선에 대한 잠재적 사고를 미연에 방지하기 위한 방사선원 모니터링 시스템 구축에 많은 시간과 재원을 투자하고 있다. 이에 본 연구에서는 다양한 비파괴검사장비에 범용적으로 적용할 수 있는 방사선원 위치 모니터링 시스템의 개발을 위한 선행연구로써 몬테카를로 시뮬레이션을 통해 산화납 기반 방사선 검출기에 대한 감마선 응답 특성을 모의 추정하였다. 연구 결과, 방사선 검출기의 최적화 두께는 방사선원에서 방사되는 감마선 에너지에 따라 상이하며 에너지가 증가함에 따라 최적화 두께가 점차 증가하는 것으로 나타났다. 결론적으로 PbO 기반 방사선 검출기의 최적화 두께는 Ir-192에 대하여 $200{\mu}m$, Se-75 $150{\mu}m$, Co-60 $300{\mu}m$로 분석되었다. 이러한 연구 결과를 바탕으로 범용적으로 적용하기 위하여 2차 전자 평형을 고려한 PbO 기반 방사선 검출기의 적절한 두께는 $300{\mu}m$로 평가되었다. 이러한 결과는 차후 다양한 NDT 장비에 범용적으로 적용하기 위한 방사선원 위치 모니터링 시스템을 개발 시 방사선 검출기에서 요구되는 적절한 두께를 결정하는데 있어 기초자료로 활용될 수 있을 것으로 사료된다.