• Title/Summary/Keyword: auto-stereoscopic 3D display

Search Result 22, Processing Time 0.047 seconds

Characterization of auto-stereoscopic and polarization based 3D displays: a common approach

  • Leroux, Thierry;Boher, Pierre;Collomb-Patton, Veronique;Bignon, Thibault
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2009.10a
    • /
    • pp.975-978
    • /
    • 2009
  • Even if auto-stereoscopic and polarization based 3D displays are not working with the same principles, their common aim is to provide two different images in the eyes of the observer. In this paper we show that Fourier optics instrument for viewing angle measurements can be applied to both types of displays. Luminance measurements are made at different locations and what will be seen by an observer in front of the display is predicted. Precise 3D characteristics can be derived and direct comparison becomes possible.

  • PDF

Auto-stereoscopic 60 view 3D using slanted Lenticular lens array

  • Im, Hee-Jin;Lee, Byung-Joo;Hong, Hyung-Ki;Shin, Hyun-Ho
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2007.08b
    • /
    • pp.1500-1503
    • /
    • 2007
  • Auto-stereoscopic 3D of 60-view number is made using slanted lenticular lens array and LCD of 15.1 inch diagonal size and 3200 by 2400 pixel numbers. Due to its large view number, smooth motion parallax is observed and the visual fatigue is reduced.

  • PDF

Development of 3D Display System for Video-guide Operation

  • Honda, Toshio;Suzuki, Kou;Kuboshima, Yasuhito;Shiina, Tatsuo
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2007.08b
    • /
    • pp.1799-1802
    • /
    • 2007
  • In the constructed auto-stereoscopic display system for one observer. 1.stereoscopic images displayed on a special LCD are made on a large concave mirror. 2.The view-zone limiting aperture is set between the projection lens and the concave mirror. 3.The real image of the aperture is made at the observer's eye position by the concave mirror. 4.The observer's eye-position tracking of the view-zone is realized. 5.At same time, stereoscopic image changes automatically according to the eye position of the observer.

  • PDF

3D Display in Mobile Applications

  • Nam, Hui;Kim, Beom-Shik;Park, Chan-Young;Gu, Ja-Seng;Chung, Ho-Kyoon
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2006.08a
    • /
    • pp.1561-1564
    • /
    • 2006
  • SDI has been developing mobile 3D display for years. For mobile applications, we adapted parallax barrier method. We have developed auto stereoscopic swing 3D display in which people can 3D image in both portrait and landscape mode. Furthermore to increase 3D resolution, we have developed a high resolution 3D display using time division multiplexing parallax barrier method

  • PDF

Auto-Stereoscopic 60 View 3D using Slanted Lenticular Lens Arrays

  • Im, Hee-Jin;Lee, Byung-Joo;Hong, Hyung-Ki;Shin, Hyun-Ho
    • Journal of Information Display
    • /
    • v.8 no.4
    • /
    • pp.23-26
    • /
    • 2007
  • A natural 3D image is considered by many people to be next-step in evolution of displays. This paper introduces autostereoscopic 3D of 60-view number, which is made using slanted lenticular lens array and LCD of 15.1 inch diagonal size and 3200 by 2400 pixel numbers and presents the results of our prototype. Due to its large view number, smooth motion parallax is observed and the visual fatigue is reduced.

Universal Stereoscopic Display Using 64 LCD's

  • Takaki, Yasuhiro
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2002.08a
    • /
    • pp.289-292
    • /
    • 2002
  • A new technique to construct an auto-stereoscopic display that offers massive horizontal parallax images is proposed Multiple telecetnric imaging systems are arranged in a modified 2D array. The horizontal parallax images displayed by LCD panels are imaged to be superimposed on a 3D screen. All parallax images are displayed in the different horizontal directions because all imaging systems have different horizontal positions. The difference of the vertical display directions due to the imaging system's vertical positions is canceled by a vertical diffuser placed at the 3D screen. Observers can percept 3D images with the binocular disparity, the vergence, and the smooth motion parallax. In addition, the accommodation function may also work because a number of parallax images are displayed with a very small angle interval in the horizontal direction. A prototype 3D display including 64 color LCD panels was constructed.

  • PDF

Visual Comfort Enhancement of Auto-stereoscopic 3D Display using the Characteristic of Disparity Distribution (시차 분포 특성을 이용한 오토스테레오스코픽 3차원 디스플레이 시청 피로도 개선 방법)

  • Kim, Donghyun;Sohn, Kwanghoon
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.53 no.3
    • /
    • pp.107-113
    • /
    • 2016
  • Visual discomfort is a common problem in three-dimensional videos. Among the methods to overcome visual discomfort presented in current research, disparity adjustment methods provide little guidance in determining the condition for disparity control. We propose a diaprity adjustment based on the characteristics of disparity distribution on visual comfort, where the visual comfort level is used as the adjustment paramter, in parallax barrier type auto-stereoscopic 3D display. In this paper, we use the horizontal image shift method for disparity adjustment to enhance visual comfort. The speeded-up robust feature is used to estimate the disparity distribution of 3D sequences, and the required amount for disparity control is chosen based on the pre-defined characteristics of disparity distribution on visual comfort. To evaluate the performance of the proposed method, we used a 3D equipment. Subjective tests were conducted at the fixed optimal viewing distance. The results show that comfortable videos were generated based on the proposed disparity adjustment method.

View Point Tracking for Parallax Barrier Display Using a Low Cost 3D Imager

  • Wi, Sung-Min;Kim, Dong-Wook
    • Journal of the Korea Computer Industry Society
    • /
    • v.9 no.3
    • /
    • pp.105-114
    • /
    • 2008
  • We present an eye tracking system using a low cost 3D CMOS imager for 3D displays that ensures a correct auto stereoscopic view of position- dependent stereoscopic 3D images. The tracker is capable of segmenting the foreground objects (viewer) from background objects using their relative distance from the camera. The tracker is a novel 3D CMOS Image Sensor based on Time of Flight (TOF) principle using innovating photon gating techniques. The basic feature incorporates real time depth imaging by capturing the shape of a light-pulse front as it is reflected from a three dimensional object. The basic architecture and main building blocks of a real time depth CMOS pixel are described. For this application, we use a stereoscopic type of display using parallax barrier elements that is described as well.

  • PDF

Integral Imaging Pickup Method of Bio-Medical Data using GPU and Octree (GPU와 옥트리를 이용한 바이오 메디컬 데이터의 집적 영상 픽업 기법)

  • Jang, Young-Hee;Park, Chan;Jung, Ji-Sung;Park, Jae-Hyeung;Kim, Nam;Ha, Jung-Sung;Yoo, Kwan-Hee
    • The Journal of the Korea Contents Association
    • /
    • v.10 no.6
    • /
    • pp.1-9
    • /
    • 2010
  • Recently, 3D stereoscopic display such as 3D stereoscopic cinemas and 3D stereoscopic TV is getting a lot of interest. In general, a stereo image can be used in 3D stereoscopic display. In other hands, for 3D auto stereoscopic display, the elemental images should be generated through visualization from every camera in a lens array. Since a lens array consists of several cameras, it takes a lot of time to generate the elemental images with respect to 3D virtual space, specially, if a large bio-medical volume data is in the 3D virtual space, it will take more time. In order to improve the problem, in this paper, we construct an octree for a given bio-medical volume data and then propose a method to generate the elemental images through efficient rendering of the Octree data using GPU. Experimental results show that the proposed method can obtain more improvement comparable than conventional one, but the development of more efficient method is required.

Acceleration Method for Integral Imaging Generation of Volume Data based on CUDA (CUDA를 기반한 볼륨데이터의 집적영상 생성을 위한 고속화 기법)

  • Park, Chan;Jeong, Ji-Seong;Park, Jae-Hyeung;Kwon, Ki-Chul;Kim, Nam;Yoo, Kwan-Hee
    • The Journal of the Korea Contents Association
    • /
    • v.11 no.3
    • /
    • pp.9-17
    • /
    • 2011
  • Recently, with the advent of stereoscopic 3D TV, the activation of 3D stereoscopic content is expected. Research on 3D auto stereoscopic display has been carried out to relieve discomfort of 3D stereoscopic display. In this research, it is necessary to generate the elemental image from a lens array. As the number of lens in a lens array is increased, it takes a lot of time to generate the elemental image, and it will take more time for a large volume data. In order to improve the problem, in this paper, we propose a method to generate the elemental image by using OpenCL based on CUDA. We perform our proposed method on PC environment with one of Tesla C1060, Geforce 9800GT and Quadro FX 3800 graphics cards. Experimental results show that the proposed method can obtain almost 20 times better performance than recent research result[11].