• Title/Summary/Keyword: auto-correlation

Search Result 397, Processing Time 0.028 seconds

Effects of Perfusion Defect on the Measurement of Left Ventricular Mass, Ventricular Volume and Post-stress Left Ventricular Ejection Fraction in Gated Myocardial Perfusion SPECT (정량적 게이트 심근관류 스펙트 검사에서 관류결손이 좌심근질량 측정과 부하 후 좌심실 용적 및 구혈률에 미치는 영향)

  • Ahn, Byeong-Cheol;Bae, Sun-Keun;Lee, Sang-Woo;Jeong, Sin-Young;Lee, Jae-Tae;Lee, Kyu-Bo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.36 no.6
    • /
    • pp.381-391
    • /
    • 2002
  • Purpose: The presence of perfusion defect may influence the left ventricular mass (LVM) measurement by quantitative gated myocardial perfusion SPECT (QGS), and ischemic myocardium, usually showing perfusion defect may produce post-stress LV dysfunction. This study was aimed to evaluate the effects of extent and reversibility of perfusion defect on the automatic measurement of LVM by QGS and to investigate the effect of reversibility of perfusion defect on post-stress LV dysfunction. Subjects and Methods: Forty-six patients (male/female=34:12, mean age=64years) with perfusion defect on myocardial perfusion SPECT underwent rest and post-stress QGS. Forty patients (87%) showed reversible defect. End-diastolic volume (EDV), end-systolic volume (ESV), LV ejection fraction (EF), and LV myocardial volume were obtained from QGS by AutoQUANT program, and LVM was calculated by multiplying the LV myocardial volume by the specific gravity of myocardium. Results: LVMs measured at rest and post-stress QGS showed good correlation, and higher correlation was founded in the subjects with fixed perfusion defect and with small defect (smaller than 20%). There were no significant differences in EDVs, ESVs and EFs between obtained by rest and post-stress QGS un patients with fixed myocardial defect. Whereas, EF obtained by post-stress QGS was lower than that by rest QGS in patients with reversible defect and 10 (25%) of them showed decreases in EF more than 5% in post-stress QGS, as compared to that of rest QGS. Excellent correlations of EDVs, ESVs, EFs between rest and post-stress QGS were noted. Patients with fixed defect had higher correlation between EDVs, ESVs, EFs than patients with reversible defect. Conclusion: These results suggest that perfusion defect can affect LVM measurement by QGS and patients with reversible defect shows post-stress LV dysfunction more frequently than patients with fixed perfusion defect.

A Study on Phase-Multiplexed Volume Hologram using Spatial Light Modulator (공간광변조기를 이용한 위상다중화 체적 홀로그램에 관한 연구)

  • Jo, Jong-Dug;Kim, Kyu-Tae
    • 전자공학회논문지 IE
    • /
    • v.44 no.3
    • /
    • pp.23-34
    • /
    • 2007
  • For an effective phase multiplexing in a volume holographic system, four types of phase code, pseudo random code(PSC), Hadamard matrix(HAM), pure random code(PRC), equivalent random code(ERC), used as reference beams are generated. In case of $32{\times}32$ address beam, a phase error with 0%, 5%, 10%, 15%, 20%, and 25% error rate, is purposely added to the real phase values in order to consider the practical SLM's nonlinear characteristics of phase modulation in computer simulation. Crosstalks and SNRs(signal-to-ratio) are comparatively analyzed for these phase codes by the auto-correlation and cross-correlation. PSC has the lowest cross-correlation mean value of 0.067 among four types of phase code, which means the SNR of the pseudo random phase code is higher than other phase codes. Also, the standard deviation of the pseudo random phase code indicating the degree of recalled data degradation is the lowest value of 0.0113. In order to analyze the affect by variation of pixel size, simulation is carried out by same method for the case of $32{\times}32$, $64{\times}64$, $128{\times}128$, $256{\times}256$ address beams.

Hallux Valgus and Cartilage Erosion in First Metatarsal Head: Correlation between Intraoperative Cartilage Erosion and Preoperative Parameters (무지외반증 환자에서 제1중족골두의 연골 미란: 수술 중 실측한 연골 미란과 수술 전 측정지표의 연관성)

  • Yune, Young-Phil;Song, Ho-Sup;Nam, Ho-Jin;Lee, Chang-Soo;Lee, Bong-Joo
    • Journal of Korean Foot and Ankle Society
    • /
    • v.15 no.2
    • /
    • pp.68-71
    • /
    • 2011
  • Purpose: To analyze relation between age or parameters measured before operation and cartilage erosion of the first metatarsal head measured during operation. Materials and Methods: The study was targeted at 56 patients and 79 feet, who underwent Scarf osteotomy or Scarf and Akin osteotomy from November 2009 through November 2010, and whose cartilage lesion of the first metatarsal head referred to the cartilage grade III or IV of the International Cartilage Repair Society. The measurement parameters were age, hallux valgus angle, intermetatarsal angle (1~2), tibial sesamoid position, proximal articular set angle and distal articular set angle. The cartilage erosion of the first metatarsal head was measured by one surgeon using cellophane. Occupancy rate and frequent involved sites of the cartilage erosion were recorded using Auto$CAD^{(R)}$ and adobe Illustrator CS4 program. SPSS correlation test and T-test were used for statistical analysis of the parameters and the cartilage erosion. Results: The cartilage erosion was incurred frequently in the sagittal groove and the site where subluxation or dislocation of the tibial sesamoild bone occurred but frequent involved sites had no statistical significance with cartilage erosion. The age showed a statistical significance with the cartilage erosion in the correlation test (p=0.003). Especially, the group of over 51 year old patients was turned out to have association with the cartilage erosion, compared to the group of below 51 (p=0.007). But, hallux valgus angle, intermetatarsal angle (1~2), tibial sesamoid position, proximal articular set angle and distal articular set angle were no statistical significance with the cartilage erosion. Conclusion: We found the more the age of patients increased (especially above 51), the more cartilage erosion increased. And it is thought that we pay attention to reduce tibial sesamoid bone.

Performance Analysis of Complex Phase-code for Phase Multiplexes Holographic Memory System (위상 다중화 홀로그래픽 메모리 시스템을 위한 CPC 위상코드의 성능 분석)

  • 조병철;김정진;김은수
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.28 no.1C
    • /
    • pp.1-8
    • /
    • 2003
  • In this paper, performance of the CPC(complex phase code) which is recently proposed as a practical phase encoding method for phase-code multiplexes holographic memory system is comparatively analyzed with those of the conventional phase codes such as PR(pure random code), RCE(random code with equality), WHM(Walsh Hadamard Matrix). In computer simulation, the size of an address bean is fixed at 32$\times$32 pixels and 0%-25% phase-error ratio in a pixel are intentionally added to the real phase values to consider the nonlinear phase-modulation characteristics of the practical spatial light modulator. From comparative analysis of crosstalks and signal-to-noise ratios for these phase codes by calculating auto-correlation and cross-correlation, it is found that the CPC have the lowest cross-correlation mean value of 0.021, the lowest standard deviation of 0.0113 and the highest signal-to-noise ratio(SNR) of 27.4 among the four types of phase code. In addition, from the calculation of the number of all possible address beams for these four types of phase code as the size of the address beam is fixed to 3232 pixels, the CPC is found to have 6.334$\times$10$^{49}$ address beams, which are relatively higher number than that of the conventional phase codes.

Characteristics and Prediction of Total Ozone and UV-B Irradiance in East Asia Including the Korean Peninsula (한반도를 포함한 동아시아 영역에서 오존전량과 유해자외선의 특성과 예측)

  • Moon, Yun-Seob;Seok, Min-Woo;Kim, Yoo-Keun
    • Journal of Environmental Science International
    • /
    • v.15 no.8
    • /
    • pp.701-718
    • /
    • 2006
  • The average ratio of the daily UV-B to total solar (75) irradiance at Busan (35.23$^{\circ}$N, 129.07$^{\circ}$E) in Korea is found as 0.11%. There is also a high exponential relationship between hourly UV-B and total solar irradiance: UV-B=exp (a$\times$(75-b))(R$^2$=0.93). The daily variation of total ozone is compared with the UV-B irradiance at Pohang (36.03$^{\circ}$N, 129.40$^{\circ}$E) in Korea using the Total Ozone Mapping Spectrometer (TOMS) data during the period of May to July in 2005. The total ozone (TO) has been maintained to a decreasing trend since 1979, which leading to a negative correlation with the ground-level UV-B irradiance doting the given period of cloudless day: UV-B=239.23-0.056 TO (R$^2$=0.52). The statistical predictions of daily total ozone are analyzed by using the data of the Brewer spectrophotometer and TOMS in East Asia including the Korean peninsula. The long-term monthly averages of total ozone using the multiplicative seasonal AutoRegressive Integrated Moving Average (ARIMA) model are used to predict the hourly mean UV-B irradiance by interpolating the daily mean total ozone far the predicting period. We also can predict the next day's total ozone by using regression models based on the present day's total ozone by TOMS and the next day's predicted maximum air temperature by the Meteorological Mesoscale Model 5 (MM5). These predicted and observed total ozone amounts are used to input data of the parameterization model (PM) of hourly UV-B irradiance. The PM of UV-B irradiance is based on the main parameters such as cloudiness, solar zenith angle, total ozone, opacity of aerosols, altitude, and surface albedo. The input data for the model requires daily total ozone, hourly amount and type of cloud, visibility and air pressure. To simplify cloud effects in the model, the constant cloud transmittance are used. For example, the correlation coefficient of the PM using these cloud transmissivities is shown high in more than 0.91 for cloudy days in Busan, and the relative mean bias error (RMBE) and the relative root mean square error (RRMSE) are less than 21% and 27%, respectively. In this study, the daily variations of calculated and predicted UV-B irradiance are presented in high correlation coefficients of more than 0.86 at each monitoring site of the Korean peninsula as well as East Asia. The RMBE is within 10% of the mean measured hourly irradiance, and the RRMSE is within 15% for hourly irradiance, respectively. Although errors are present in cloud amounts and total ozone, the results are still acceptable.

Analysis of Refractive Errors of the before and after Cataract Surgery by Auto-refractor (안굴절계를 이용한 백내장 수술전후의 굴절이상 분석)

  • Oh, Hyun-Jin;Jung, Mi-A
    • Journal of Convergence Society for SMB
    • /
    • v.6 no.3
    • /
    • pp.65-69
    • /
    • 2016
  • We investigated refractive errors and corneal power with 3 factors such as M, $J_0$, and $J_{45}$ as power vector to find out the changes of refractive errors of the before and after cataract surgery in 119 adults aged 45~85 years with cataract. After the surgery, the 3 factors were changed as $-0.29{\pm}2.38D$ to $-0.18{\pm}0.69D$ in spherical equivalent power which is the M factor, $-0.34{\pm}0.68D$ to $-0.05{\pm}0.42D$ in the $J_0$ factor, and $0.11{\pm}0.45$ to $0.02{\pm}0.17$ in the $J_{45}$ factor. Before and after the surgery, corneal mean refractive power, $J_0$, and $J_{45}$ were changed from $44.11{\pm}1.61D$ to $44.20{\pm}1.58D$, $0.01{\pm}0.50D$ to $0.08{\pm}0.49D$, and $0.02{\pm}0.29$ to $0.08{\pm}0.49$, respectively. The results showed that $J_0$ was the highest relativeness in correlation of the pre- and post-surgery for refractive errors, mean corneal power was the highest correlation for corneal power factor, and corneal power factor was the higher correlation much more than refractive error factor.

A Comparative Analysis of Patient Visibility, Spatial Configuration and Nurse Walking Distance in Korean Intensive Care Units(ICUs) - Focused on single corridor, Pod and Composite type units

  • Ullah, Ubaid;Park, Jae Seung
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.22 no.4
    • /
    • pp.37-45
    • /
    • 2016
  • Purpose: The purpose of this paper is to analyze a sample of single corridor, pod type and composite type of ICUs in terms of patient visibility, spatial configurations and nurse walking distance focused on Korean cases. Methods: The measures of static visibility were used to quantify the patient visibility (upper third part of the patient bed) from the nurse station. The measure of space programme and area distribution (patient zone percentage, staff zone percentage, circulation zone percentage, corridor length per bed, distance from nurse station (NS) to patient bed and departmental gross square meter (DGSM) per patient bed) were calculated by using AutoCAD and MS Excel programs. In the second step of analysis the values of space distribution were compared among the three type of ICUs as well as the nurse walking distance, DGSM per bed and gross factor. in the third step of analysis regression analysis was conducted for the possible correlation between visibility and space programme and area distribution factors as well as nurse walking distance factors. Results: (1) It was found that on average composite type unit offer highest value of patient visibility followed by pod type, while single corridor type unit offers the minimum value of patient visibility among the three plan typologies. (2) Average patient visibility and DGSM per bed shows a strong positive correlation ($r^2=0.75$) and p=0.026. (3) Average patient visibility and average distance from NS has a strong negative correlation ($r^2=0.78$), and P=0.02. (4) On average composite type unit offer the minimum walking distance from NS (7.22 meter) followed by pod type unit (8.35 meter) and single corridor (9.76 meter). (5) Maximum distance from NS was noted in single corridor (18.19 meter) followed by pod type unit (15.14 meter) and Composite type unit (11.1 meter). Implications: This study may contribute to the visibility analysis of existing and future ICU design in Korea to achieve maximum patient visibility and reduced nurse walking distance.

IoT data trust techniques based on auto-encoder through IoT-linked processing (오토인코더 기반의 IoT 연계 처리를 통한 IoT 데이터 신뢰 기법)

  • Yon, Yong-Ho;Jeong, Yoon-Su
    • Journal of Digital Convergence
    • /
    • v.19 no.11
    • /
    • pp.351-357
    • /
    • 2021
  • IoT devices, which are used in various ways in distributed environments, are becoming more important in data transmitted and received from IoT devices as fields of use such as medical, environment, transportation, bio, and public places are diversified. In this paper, as a method to ensure the reliability of IoT data, an autoencoder-based IoT-linked processing technique is proposed to classify and process numerous data by various important attributes. The proposed technique uses correlation indices for each IoT data so that IoT data is grouped and processed by blockchain by characteristics for IoT linkage processing based on autoencoder. The proposed technique expands and operates into a blockchain-based n-layer structure applied to the correlation index to ensure the reliability of IoT data. In addition, the proposed technique can not only select IoT data by applying weights to IoT collection data according to the correlation index of IoT data, but also reduce the cost of verifying the integrity of IoT data in real time. The proposed technique maintains the processing cost of IoT data so that IoT data can be expanded to an n-layer structure.

Emotion Recognition System Using Neural Networks in Textile Images (신경망을 이용한 텍스타일 영상에서의 감성인식 시스템)

  • Kim, Na-Yeon;Shin, Yun-Hee;Kim, Soo-Jeong;Kim, Jee-In;Jeong, Karp-Joo;Koo, Hyun-Jin;Kim, Eun-Yi
    • Journal of KIISE:Software and Applications
    • /
    • v.34 no.9
    • /
    • pp.869-879
    • /
    • 2007
  • This paper proposes a neural network based approach for automatic human emotion recognition in textile images. To investigate the correlation between the emotion and the pattern, the survey is conducted on 20 peoples, which shows that a emotion is deeply affected by a pattern. Accordingly, a neural network based classifier is used for recognizing the pattern included in textiles. In our system, two schemes are used for describing the pattern; raw-pixel data extraction scheme using auto-regressive method (RDES) and wavelet transformed data extraction scheme (WTDES). To assess the validity of the proposed method, it was applied to recognize the human emotions in 100 textiles, and the results shows that using WTDES guarantees better performance than using RDES. The former produced the accuracy of 71%, while the latter produced the accuracy of 90%. Although there are some differences according to the data extraction scheme, the proposed method shows the accuracy of 80% on average. This result confirmed that our system has the potential to be applied for various application such as textile industry and e-business.

Comparison on Accommodative Response Changes in the Normal Group and Convergence Insufficiency (정상군과 폭주부족군에서 조절반응 변화량의 비교)

  • Kwak, Ho-Weon;Lee, Se-Hee;Kwak, Hyung-Bin
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.19 no.1
    • /
    • pp.79-85
    • /
    • 2014
  • Purpose: This study investigated accommodative changes by measuring accommodative response, appearing on the normal and convergence insufficiency Group, by using both eyes open-view auto-refractometer (Nvision-K5001, shin-nippon, Japan). Methods: It carried out objective and subjective refractions, targeting 74 college students (54 males and 20 females) aged between 19 and 29 ($21.59{\pm}2.53$), spherical equivalent OD $-2.28{\pm}2.03$ D, OS $-2.18{\pm}2.01$ D, by measuring accommodative responses at full correction and under correction with plus lens +0.25, +0.50, +0.75 arbitrarily added. Results: In the group of normal and convergence insufficiency, the shorter fixation distances were, the greater accommodative lags showed. The group of convergence insufficiency showed the lesser changes of accommodative response than those of normal. But we found that the convergence insufficiency group had a little larger accommodative amplitude in the total fixation distances. The full correction of convergence insufficiency group and the under correction (+0.50 D) of normal were alike in the accommodative responses. We have also investigated that the correlation between accommodative responses and fixation distances was decreased steeply at the excessive low vision correction. Conclusions: Under correction (+0.50 D) in a near distance is expected to avoid unnecessary accommodative responses, make eyes relaxed and comfortable.