• Title/Summary/Keyword: attachment rate

Search Result 270, Processing Time 0.024 seconds

Evaluation of Fluoride Removal Effect with Growth of Attached Microbial Community in Middle and Small Stream (중·소하천에서 부착미생물군집의 성장에 따른 불소 제거 효과 평가)

  • Kim, Tae-Kyung;Ryu, Seo-Young;Park, Yoon-A;Lee, Jong-Jun;Joo, Kwang-Jin;Chang, Kwang-Hyeon;Oh, Jong-Min
    • Journal of Environmental Impact Assessment
    • /
    • v.27 no.6
    • /
    • pp.595-603
    • /
    • 2018
  • This study was conducted to understand the growth of attached microbial community in small and medium streams of Gyeonggi-do and the removal efficiency of fluoride with changes in growth. The sites monitoring were carried out for 12 weeks at the P1 and P2(P1 is the point where the discharge water flows. P2 is the downstream point of about 2 km flow), and investigated the water quality and the biomass analysis of the attached microbial community. The growth of the attached microbial community increased up to the 7th investigation, and it was observed that detachment phenomenon occurred. Influencing factors about growth of the attached microbial community were flow rate, velocity, and organic material(T-N & T-P). Meanwhile, fluoride content of attached microbial community also tended to increase until the 7th investigation, and decrease from the 8th. It is assumed that fluoride content has also be reduced with the detachment phenomenon of the attached microbial community. It is expected that this will contribute to the evaluation and management of the use of attached microbial community as a means of stream management. The application of techniques using the attached microbial community should include basic investigation of factors that may affect the growth of the attached microbial community and replacement of the attachment plate according to the time of removal.

Periodontal pathogens and the association between periodontitis and rheumatoid arthritis in Korean adults

  • Kim, Jin-Hee;Choi, In Ah;Lee, Joo Youn;Kim, Kyoung-Hwa;Kim, Sungtae;Koo, Ki-Tae;Kim, Tae-Il;Seol, Yang-Jo;Ku, Young;Rhyu, In-Chul;Song, Yeong Wook;Lee, Yong-Moo
    • Journal of Periodontal and Implant Science
    • /
    • v.48 no.6
    • /
    • pp.347-359
    • /
    • 2018
  • Purpose: Periodontitis and rheumatoid arthritis (RA) share a similar inflammatory pathogenesis. Porphyromonas gingivalis (Pg) can induce anticyclic-citrullinated peptide autoantibodies (anti-CCP antibodies), a key factor in the development of RA. This study aimed at evaluating the relationships between the 2 diseases and identifying the clinical implications thereof, with a focus on periodontal pathogens in Korean adults. Methods: A total of 260 RA patients and 86 age- and sex-matched control patients without arthritis were enrolled in this prospective cross-sectional study. Periodontal indices and the prevalence and amount of periodontal pathogens were compared between the groups. Correlations between periodontal and RA indices were examined, as were correlations between 9 periodontal pathogens and RA indices. Results: The RA group had significantly higher values than the control group for all investigated periodontal indices (P<0.05) except the number of teeth. The gingival index (GI) was correlated with the disease activity score 28 (DAS28) (r=0.125, P=0.049), RA disease duration (r=0.253, P<0.001), erythrocyte sedimentation rate (ESR) (r=0.162, P=0.010), and anti-CCP antibody titer (r=0.205, P=0.004). Probing pocket depth (PPD) was correlated with ESR (r=0.139, P=0.027) and anti-Pg antibody titer (r=0.203, P=0.001). Bleeding on probing (BOP) was correlated with DAS28 (r=0.137, P=0.030), RA disease duration (r=0.202, P=0.001), ESR (r=0.136, P=0.030), anti-Pg antibody titer (r=0.177, P=0.005), and anti-CCP antibody titer (r=0.188, P=0.007). Clinical attachment level (CAL) and periodontitis severity were correlated with anti-Pg antibody titer (the former r=0.201, P=0.002; the latter r=0.175, P=0.006). The quantity of Pg was positively correlated with the serum anti-Pg antibody titer (r=0.148, P=0.020). Conclusions: The GI, BOP, and PPD showed positive relationships with several RA indices. The anti-Pg antibody titer had positive relationships with PPD, BOP, CAL, and periodontitis severity. Thus, increasing values of periodontal indices could be used as a risk indicator of disease development in RA patients, and an increasing anti-Pg antibody titer could be considered as a warning sign in RA patients suffering with periodontitis.

Optimization of Elastic Modulus and Cure Characteristics of Composition for Die Attach Film (다이접착필름용 조성물의 탄성 계수 및 경화 특성 최적화)

  • Sung, Choonghyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.4
    • /
    • pp.503-509
    • /
    • 2019
  • The demand for smaller, faster, and multi-functional mobile devices in increasing at a rapidly increasing rate. In response to these trends, Stacked Chip Scale Package (SCSP) is used widely in the assembly industry. A film type adhesive called die attach film (DAF) is used widely for bonding chips in SCSP. The DAF requires high flowability at high die attachment temperatures for bonding chips on organic substrates, where the DAF needs to feel the gap depth, or for bonding the same sized dies, where the DAF needs to penetrate bonding wires. In this study, the mixture design of experiment (DOE) was performed for three raw materials to obtain the optimized DAF recipe for low elastic modulus at high temperature. Three components are acrylic polymer (SG-P3) and two solid epoxy resins (YD011 and YDCN500-1P) with different softening points. According to the DOE results, the elastic modulus at high temperature was influenced greatly by SG-P3. The elastic modulus at $100^{\circ}C$ decreased from 1.0 MPa to 0.2 MPa as the amount of SG-P3 was decreased by 20%. In contrast, the elastic modulus at room temperature was dominated by YD011, an epoxy with a higher softening point. The optimized DAF recipe showed approximately 98.4% pickup performance when a UV dicing tape was used. A DAF crack that occurred in curing was effectively suppressed through optimization of the cure accelerator amount and two-step cure schedule. The imizadole type accelerator showed better performance than the amine type accelerator.

Development of Wrist Tunnel Syndrome Prevention Smart Gloves using CNT-based Tensile Fabric Sensor: Focusing on Mouse Use (CNT 기반의 인장 직물 센서를 사용한 손목터널증후군 예방 스마트장갑 개발: 마우스사용을 중심으로)

  • Chun, Se-Hwan;Kim, Sang-Un;Kim, Joo-Yong
    • Science of Emotion and Sensibility
    • /
    • v.24 no.4
    • /
    • pp.117-128
    • /
    • 2021
  • In this work, we study smart gloves that can prevent carpal tunnel syndrome when using a mouse. Because the left and right wrist movements are fine, a tensile fabric sensor with a large gauge factor and low hysteresis was required before the study. A universal testing machine was used to calculate each gauge rate on four different fabrics, and the fabric with the least hysteresis was selected. In addition, three attachment methods were analyzed using Arduino to select a method with a large sensor value change. For prototypes made by attaching to the selected fabric, data patterns were analyzed using Arduino. The first method identifies only one sensor (A sensor), and the second identifies two sensors (A and B sensors). When the wrist is bent to the right, tensile fabric sensors are attached to both the left (A sensor) and right (B sensor) sides of the wrist, the A sensor is strained, increasing the △sensor value, and the B sensor is relaxed, decreasing the △sensor value. However, when the wrist was bent to the left, the pattern was analyzed in the opposite direction. Through this study, we examined smart gloves to prevent carpal tunnel syndrome with an algorithm that turns on the LED when the wrist is bent, and based on the results of this study, we will directly use mice on 10 people to identify problems and solve problems when used.

Flexural Reinforcement of Timber Beams Using Carbon Fiber Plates (탄소섬유판을 사용한 목재 보의 휨보강)

  • Choi, Jin-Chul;Kim, Seung-Hun;Lee, Yong-Taeg
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.26 no.6
    • /
    • pp.238-246
    • /
    • 2022
  • This paper summarizes the development and evaluation of the reinforcement details of CFRP plates to improve the bending performance of wooden beams. In this study, the reinforcing technology using high-strength bolts for the end of beam were developed as reinforcement details for reinforcing wooden beams with CFRP plates by EBM method. In order to evaluate the bending performance, a bending test was conducted for the specimens with details of reinforcement such as the EBM method and the NSM method. From the experimental results, the EBM specimens without end restraints had both the CFRP plate attachment failure and the splitting failure of the wood. In the load-displacement curve, the non-reinforced specimens exhibited linear elastic behavior and then brittle fracture after the maximum load. The maximum load of the specimens reinforced by the EBM method increased by 31.5~63.0% compared to the non-reinforced specimens, and the maximum load according to the end restraints of the high-strength bolts increased by 24.0%. Based on the reinforcement amount of the same CFRP plate, EBM reinforcement was 2.67 times larger in maximum load increase rate than NSM reinforcement.

Study on Wearable Health Care Devices Function Using Quantified Self - Focusing on Cardio-cerebrovascular Disease - (수치화 된 자아를 활용한 헬스케어 웨어러블 디바이스 기능 분석 - 심뇌혈관 질환 중심으로 -)

  • Lee, Ye Rim;Jung, Jung Ho
    • Design Convergence Study
    • /
    • v.16 no.5
    • /
    • pp.1-20
    • /
    • 2017
  • Cardio-cerebrovascular disease is one of the chronic diseases that often attack people in Korea, and in fact, it ranks second in terms of death rate. This disease can be prevented by improving lifestyle, usual health care is important. But, in Korea most of the prevention or management programs adopt passive methods like using guide books or giving lectures, so it is not very effective in preventing the disease. Presently, the smart health care market is being developed in Korea and overseas. As an example, quantified self is being spread through wearable devices which are intended to measure each individual's health conditions and quantify body data into numbers for bettering habits. Accordingly, this author will explore and discuss wearable health care devices so as to prevent and manage cardio-cerebrovascular disease in a more active way. First, this study has classified wearable health care devices presently commercialized or related with cardio-cerebrovascular disease into wrist, clothes, or attaching types by the way of their attachment and analyzed them. After that, summing that up, this author performed cross-tabulations with other ways of preventing cardio-cerebrovascular disease. This will contribute to improving one's health care behavior about disease more actively and also work as an active interdisciplinary mechanism in research dealing with how to prevent disease afterwards.

Evaluation of Attenuation Rate Error on Skin Dosimeter using Monte Carlo Simulation in Photon and Electron Beam Therapy (광자선 및 전자선 치료에서 피부선량계의 측정과 시뮬레이션을 이용한 감약률 오차 평가)

  • Han, Moo-Jae;Yang, Seung-Woo;Heo, Seung-Uk;Bae, Sang-Il;Moon, Young-Min;Park, Sung-Kwang;Kim, Jin-Young
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.6
    • /
    • pp.841-848
    • /
    • 2020
  • In the field of radiation therapy using photon beams and electron beams, since each patient has a different sensitivity to radiation, skin side effects may occur even at the same dose. Therefore, if there is a risk of excessive dose to the skin, a dosimeter is attached to verify whether the correct dose is being investigated. However, since the skin dosimeter checks the attachment site visually by measuring a point dose, it is difficult to confirm an accurate dose distribution. As a result, the measurement and simulation errors of the material HgI2 in the 6 MV photon beam were 3.73% and 5.24%, respectively, at the minimum thickness of 25 ㎛, and the material PbI2 was 4.73% and 5.65%, respectively. On the other hand, as a result of the 6 MeV electron beam, the measurement and simulation errors of the material HgI2 were 1.35% and 1.12%, respectively, at a minimum thickness of 25 ㎛, and the material PbI2 showed relatively low attenuation error, 1.67% and 1.20%, respectively. Therefore, it was evaluated that the thickness of the photon beam within 25 ㎛ and the electron beam within 100 ㎛ is suitable to have a reduction rate error within 5%. This study presents a new research direction for a flexible dosimeter attached to the human body that is required in clinical practice and the construction conditions of a future skin dosimeter.

Nitrification at Low Concentration of NH4+-N by using Attached Growth in Zeolite Media (제올라이트 여재의 부착성장을 이용한 저농도 NH4+-N의 생물학적 질산화 처리)

  • Kim, Jin-Su;Kang, Min-Koo;Yang, Chang-Hwan;Lee, Sang-Ill
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.39 no.10
    • /
    • pp.561-567
    • /
    • 2017
  • This study focused on estimating the low concentration of $NH_4{^+}-N$ removal by using simultaneous reaction of the adsorption and microbial nitrification with microbe-attached zeolite media. To evaluate the adsorption effect of the zeolite media, the expanded polypropylene (EPP) media which are not able to adsorb $NH_4{^+}-N$ were used as a control media in order to compare the adsorption ability. Each media was used to experiment after aerated 8 hr for attachment of the microbes. The batch experiment shows that nitrification occurred in zeolite media better than EPP media because nitrifiers could consume the relatively enough amount of $NH_4{^+}-N$ adsorbed onto the zeolite media. Compared to the reactor with EPP media, nitrification occurred only in the reactor with zeolite media under continuous operation at the empty bed contact time (EBCT) of 25 min and 3 mg/L of $NH_4{^+}-N$ concentration. As the EBCT of the reactor with zeolite media increased from 10 to 60 min, the nitrification efficiencies increased too. $NH_4{^+}-N$ removal efficiency showed up more than 90% at EBCT 60 min. And the difference in concentration of the total nitrogen between the influent and the effluent was 0.25 mg/L at EBCT 10 min, 0.78 mg/L at EBCT 25 min, 0.59 mg/L at EBCT 40 min and 0.37 mg/L at EBCT 60 min, respectively. This difference was due to between adsorption rate and nitrification rate of $NH_4{^+}-N$, and it was considered that $NH_4{^+}-N$ was adsorbed on the zeolite media by the gap of the concentration.

Genotyping and Clinical study of Mycoplasma pneumoniae During 1996-1997 in Korea (1996년과 1997년 소아에서 유행한 Mycoplasma pneumoniae의 Genotype에 따른 임상적 연구)

  • Lim, Hong Hee;Ahn, Byung Moon;Kim, Eun Ryoung;Choi, Sug Ho;Moon, Young Ho;Kim, Il Soo
    • Pediatric Infection and Vaccine
    • /
    • v.5 no.1
    • /
    • pp.79-87
    • /
    • 1998
  • Purpose : The P1 protein of Mycoplasma pneumoniae mediates the attachment of the pathogen to its host cell and elicits a strong humoral immune response during infection with this organism. Mycoplasma pneumoniae strains can be classified into two groups(I and II) by PCR method of P1 cytadhesin gene. In this study, we evaluated the prevalence, epidemiological and clinical characteristics of each group. Methods : From 155 patients with Mycoplasma pneumoniae, who admitted to the Department of Pediatrics, Sung-Ae and Kwangmyung Sung-Ae Hospital between November 1996 and October 1997, we collected their throat swabs or nasopharyngeal aspirates for DNA extraction and serum for indirect hemagglutination test of Mycoplasma pneumoniae. The group specific PCR amplification were performed using specific oligonucleotide primers designed for P1 gene genotyping. Results : Group I(137 patients, 88.4%) occurred frequently than group II(18 patients, 11.6%). In both group, the most prevalent season was winter in 1996(Nov. to Dec.) and fall in 1997(Aug. to Oct.) The prevalent age was four to six years old. The number of male was more than female in both group; Group 1(1.2:1), Goup 2(1.6:1). No significant relationship were found between two groups in duration of fever and hospital days(P>0.05). The rate of high antibody titers(>1:5120) was lower in group I(6/137, 4.4%) than group II(2/18, 11.1%). Conclusion : Group I was much more prevalent than group II during 1996~1997 in Korea. There was no difference between two groups in epidemiological and clinical parameters except the rate of high antibody titers. Further follow-up survey will be needed for the epidemiologic and clinical studies of Mycoplasma pneumoniae in Korea.

  • PDF

Performance Characteristics of Agitated Bed Manure Composting and Ammonia Removal from Composting Using Sawdust Biofiltration System (교반식 축분 퇴비화 및 톱밥 탈취처리 시스템의 퇴비화 암모니아 제거 성능)

  • Hong, J.H.;Park, K.J.
    • Journal of Animal Environmental Science
    • /
    • v.13 no.1
    • /
    • pp.13-20
    • /
    • 2007
  • Sawdust biofiltration is an emerging bio-technology for control of ammonia emissions including compost odors from composting of biological wastes. Although sawdust is widely used as a medium for bulking agent in composting system and for microbial attachment in biofiltration systems, the performance of agitated bed composting and sawdust biofiltration are not well established. A pilot-scale composting of hog manure amended with sawdust and sawdust biofiltration systems for practical operation were investigated using aerated and agitated rectangular reactor with compost turner and sawdust biofilter operated under controlled conditions, each with a working capacity of approximately $40m^3\;and\;4.5m^3$ respectively. These were used to investigate the effect of compost temperature, seed germination rate and the C/N ratio of the compost on ammonia emissions, compost maturity and sawdust biofiltration performance. Temperature profiles showed that the material in three runs had been reached to temperature of 55 to $65^{\circ}C$ and above. The ammonia concentration in the exhaust gas of the sawdust biofilter media was below the maximum average value as 45 ppm. Seed germination rate levels of final compost was maintained from 70 to 93% and EC values of the finished compost varied between 2.8 and 4.8 ds/m, providing adequate conditions for plant growth.

  • PDF