• Title/Summary/Keyword: attached-type

Search Result 1,072, Processing Time 0.027 seconds

Development of Remote Control and Monitoring System for HID Street-lamp Based on Low Cost Zigbee Communication Network (저 가격형 Zigbee 통신 네트워크 기반 HID 가로등의 원격 제어 및 감시 시스템 개발)

  • Chung, Wan-Sup;Kim, Yang-Bae;Shon, Jin-Geun
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.63 no.2
    • /
    • pp.69-73
    • /
    • 2014
  • In this paper, remote control and surveillance monitoring system of HID street-lamp using low-cost type of Zigbee communication module was developed. A plurality of capacitors with different capacity are attached to magnetic ballast for HID lamps. Changes in the amount of illumination can be adjusted by the changes in capacity so that the electric energy can be reduced. In Zigbee communication module, a ATmega128L microprocessor is used and in main CPU, ARM9 Core is used to construct a low-cost smart system. In surveillance monitoring systems, the system was configured to remote monitoring of presence of error in the lamp abnormalities, the status of leakage current and abnormalities of ballasts and capacitors and the validity of the proposed empirical experiment was confirmed.

A Study on the Variable Speed Control Characteristics of Outside Rotor type Squirrel Cage Induction Motor (외측 회전형 농형 유도전동기의 가변속 운전특성에 관한 연구)

  • 안병원;박영산;노영오;최민선;김성환;김현수
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2001.05a
    • /
    • pp.418-422
    • /
    • 2001
  • This paper presents a developed squired cage induction motor for axial flow fan. The developed squirrel cage induction noter for axial flow fan is exchanged the position, rotor and stater. In this method a fan blade is attached to outside rotor. So we can protect the motor from rain and reduce noise, and there is no need to have bending duct to locate the fan motor. Carried out experimental test with this induction motor, and the results were as follows. Starting torque was 21kgㆍcm@120V, maximum efficiency was 0.84@120V. The characteristics of tests were the same as double squirrel-cage type IM.

  • PDF

Development of precision Moving Mechanism using Ellipsoidal Motion of piezoelectric Bimorph (압전 바이모프의 타원운동을 이용한 정밀 이동기구 개발)

  • 박한길;김준형;김수현;곽윤근
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.20 no.4
    • /
    • pp.151-157
    • /
    • 2003
  • A new type of precision actuator is developed using piezoelectric bimorphs. This type of actuator is applicable for the flat surface or in-pipe system and can make forward and backward motion. Two bimorphs are linked serially and two different phased voltages are applied to each bimorph. Therefore, The end of the bimorph makes ellipsoidal motion. The device moves by the friction force between the rubber attached at the bimorph end and the inner surface of the pipe. As the results, the driving range of the device is about 0~18Hz and the device guarantees very high linearity at low frequency, 0~1 Hz. The maximum velocity of the device is about 6mm/s at 10Hz. The developed mechanism is very simple and use piezoelectric bimorph. So, it is possible to miniaturize and educe the power consumption.

Absolute Strain Measurement Using Fiber Bragg Grating Sensor (광섬유 브래그 격자 센서를 이용한 절대 변형률 측정)

  • ;Lou-shuang
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2002.10a
    • /
    • pp.416-420
    • /
    • 2002
  • This Paper describes a matched-filter type strain sensor system using optical fiber Bragg grating (FBG) sensor. Matched-filter type uses another wavelength-matched FBG filter to track wavelength shift in the FBG sensor. Filter FBG is attached on a fiber stretcher and stretched by PZT actuator. To overcome the nonlinearity and hysteresis of the PZT actuator that degrades system accuracy, a string resonator which can measure an absolute strain is employed. And the effect of vibration modes on string resonator is investigated particularly regarding its sensitivity and stability.

  • PDF

Temperature Characteristics of High Speed Angular Contact Ball Bearing (고속 앵귤러 컨택트 볼 베어링의 온도특성)

  • Hyeon, Jun-Su;Park, Tae-Jo
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.18 no.2
    • /
    • pp.96-101
    • /
    • 2001
  • This paper shows the temperature characteristics of a high speed angular contact ball gearing which is 7004C type with ISO P2 tolerance class. A built-in motor type high speed spindle which adopts an oil-air lubrication system was used to measure the temperature rise up to 60,000rpm. The gearing temperature was measured using thermocouples that were attached to the outside surfaces of the outer rings. The result showed that the continuous test method which was suggested in this paper is more effective than on and off method and the lubrication oil supply rate should be reduced in high speed rolling bearings as long as the seizure does not occur. And the result were confirmed that the bearings packed with ceramic balls are superior to those with steel balls in temperature characteristics.

  • PDF

Development of An Onion Peeler (I) - Root cutting equiment - (양파 박피기 개발(I))

  • 민영봉;김성태;정태상;최선웅;김정호
    • Journal of Biosystems Engineering
    • /
    • v.27 no.4
    • /
    • pp.301-310
    • /
    • 2002
  • With a purpose to manufacture an onion peeler, the root cutting equipment of the onion could be attached to a prototype onion peeler was developed. Before the experiment, the distribution of the dimensions of the Korean native onion were measured. And some types of the blades to cut and remove the root of the onion were designed and such characteristics as feasible revolution, conveying speed, and power requirement were investigated. From the result of the test, the selected one among the various cutters was the wing type blade with the round blade to cut out the root and with the vertical blade to cut a circular line. The optimum operating conditions of the wing type blade were revealed the revolution with no load was at 630 rpm, and the conveying speed was 0.08 m/s. Under these conditions, the maximum torque was 5.25 kg·m and the power requirement was 33 W, respectively.

A Tendency of the Lighting System by Ergonomics Planning (Ergonomics Planning에 의한 조명경향 분석)

  • Kim, Hee-Jun;Park, Tong-Wha
    • Proceedings of the KIEE Conference
    • /
    • 1999.07e
    • /
    • pp.2423-2425
    • /
    • 1999
  • During the last years demands for higher visual comfort, flexibility of the lighting system in new type of office structures, especially intelligent building, and compatibility with work at VDU place increased. At the same time better lighting conditions should be realized by energy-effective system leading to less consumption of energy. In the intelligent building need the now type of lighting control system, also it should be included for a human-sensibility. It is shown that when designing lighting for intelligent building, greater importances should be attached to the creation of a well-balanced luminance distribution in the field and research for the people by the Ergonomics Planning.

  • PDF

A Basic Study for the Control Circuit of 2-phase 8-pole HB type Linear Pulse Motor (2상 8극 HB형 리니어펄스모터의 제어회로구성을 위한 기초연구)

  • Kim, Sung-Hun;Kim, Il-Jung;Lee, Eun-Woong
    • Proceedings of the KIEE Conference
    • /
    • 1994.07a
    • /
    • pp.135-137
    • /
    • 1994
  • In this paper, step response, speed, maximum frequency characteristics of 2-phase, 8-pole, HB type, prototype linear pulse motor(LPM) were investigated with the open loop control system(OLCS) being attached to the LPH. In this experiment, both 1-phase and 1-2 phase excitation types were adopted and microcomputer was used in deal with the data. The results point to some directions for the improvement of the open loop control system.

  • PDF

Physicochemical factors affecting the adsorption of E. coli in estuarine sediments (하구퇴적토 환경에서 E.coli의 부착에 영향을 주는 물리화학적 요인)

  • 이건형
    • Korean Journal of Microbiology
    • /
    • v.26 no.3
    • /
    • pp.237-246
    • /
    • 1988
  • The higher bacterial numbers on clay than on sand were caused by different environmental factors. Such factors affecting the adsorption of E. coli ATCC 11775 in the sediment as follows; optimal pH range for the adsorption of E. coli ATCC 11775 was pH 7.5-pH 9.5. E. coli ATCC 11775 were shown maxima in the salinity of 18.$75%_{o}$ on sand type sediment and $12.5%_{o}$ on clay type sediment. Bacteria attached better to clay typed sediment than to sand typed sediment when organic substance was eliminated. Beef extract of 0.5%-1% concentration was found to promote the attachment of E. coli ATCC 11775 effectively. Peptone of 0.5% was enganced the attachment on the clay, and peptone of 1.3%-5%, on the sand. E. coli ATCC 11775 was found to adsorb onto benthonite with the highest efficiency and on celite with the lowest efficiency. Efficiency of adsorption by inorganic ions was shown due to higher values of ion. Adsorption was achieved in the order of $Al^{3+}, Ca^{2+}, Na^{+}$.

  • PDF

Controller Design using PreFilter Type Chaotic Neural Networks Compensator (Prefilter 형태의 카오틱 신경망 속도보상기를 이용한 제어기 설계)

  • Choi, Un-Ha;Kim, Sang-Hee
    • Proceedings of the KIEE Conference
    • /
    • 1998.11b
    • /
    • pp.651-653
    • /
    • 1998
  • This thesis propose the prefilter type control strategies using modified chaotic neural networks #or the trajectory control of robotic manipulator. Since the structure of chaotic neural networks and neurons, chaotic neural networks can show the robust characteristics for controlling highly nonlinear dynamics like robotic manipulators. For its application, the trajectory controller of the three-axis PUMA robot is designed by CNN. The CNN controller acts as the compensator of the PD controller. Simulation results show that learning error decrease drastically via on- line learning and the performance is excellent. The CNN controller have much better controllability and shorter calculation time compared to the RNN controller. Another advantage of the proposed controller could be attached to conventional robot controller without hardware changes.