• Title/Summary/Keyword: attached-type

Search Result 1,068, Processing Time 0.027 seconds

A Dynamic Rating System for Power Cables (I) - Real Time CTM(Conductor Temperature Monitoring) (전력 케이블 실시간 허용전류산정 시스템에 관한 연구 (I) - 실시간 도체 온도 추정 시스템)

  • 남석현;이수길;홍진영;김정년;정성환
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.52 no.7
    • /
    • pp.414-420
    • /
    • 2003
  • The domestic needs for larger capability of power sources are increasing to cope with the expanding power load which results from the industrial developments & the progressed life style. In summer, the peak load is mainly due to the non-industrial reasons such as air-conditioners and other cooling equipments. To cover the concentrated peak load in stable, the power transmission lines should be more constructed and efficiently operated. The ampacity design of the underground cable system is generally following international standards such as IEC287, IEC60853 and JCS168 which regards the shape of 100% daily full power loads. It is not so efficient to neglect the real shapes of load curves generally below 60~70% of full load. The dynamic (real time) rating system tends to be used with the measured thermal parameters which make it possible to calculate the maximum ampacity within required periods. In this paper, the CTM(Conductor Temperature Monitoring) which is the base of dynamic rating systems for tunnel environment is proposed by a design of lumped thermal network ($\pi$-type thermal model) and distribution temperature sensor attached configuration, including the estimation results of its performances by load cycle test on 345kV single phase XLPE cable.

Novel soft switching FB DC-DC converter for reducing conduction losses (도전손실 저감을 위한 새로운 소프트 스위칭 FB DC-DC 컨버터)

  • Kim, E.S.;Joe, K.Y.;Kye, M.H.;Kim, Y.H.;Yoon, B.D.
    • Proceedings of the KIEE Conference
    • /
    • 1996.07a
    • /
    • pp.388-391
    • /
    • 1996
  • The conventional high frequency phase-shifted full bridge DC-DC converter has a disadavantage that a circulating current flows through transformer and switching devices during the freewheeling interval Due to this circulating current, RMS current stress, conduction losses of transformer and switching devices are increased. To alleviate this problem, this study provides a novel circulating current free type high frequency soft switching phase-shifted full bridge DC-DC converter which applies the energy recovery snubber(ERS) attached at the secondary side of transformer. The ERS adopted in this study is consisted of three fast recovery diode($Ds_1$, $Ds_2$, $Ds_3$), two resonant capacitor($Cs_1$, $Cs_2$) and a small resonant inductor [(Lr) : It can be ignored because the transformer leakage inductance(Ll) is able to use in stead of inserting the resonant inductor(Lr)]

  • PDF

A numerical study on the acoustic characteristics of centrifugal impeller with small added vane (작은 안내 깃이 붙은 원심형 임펠러의 소음 특성에 대한 연구)

  • Jeon, Wan-Ho
    • The KSFM Journal of Fluid Machinery
    • /
    • v.4 no.1 s.10
    • /
    • pp.22-29
    • /
    • 2001
  • Centrifugal fans are widely used in industrial practices but the noise generated by these machines causes one of the most serious problems. In general, the centrifugal fan noise is often dominated by tones at BPF(blade passage frequency) and its higher harmonics. This is a consequence of the strong interaction between the flow discharged from the impeller and the cutoff in the easing. However, only a few researches have been carried out on predicting the noise because of the difficulty in obtaining detailed information about the flow field and casing effects on noise radiation. The objective of this study is to develop a prediction method for the unsteady flow field and the acoustic pressure field of a centrifugal fan, and to calculate the effects of small vanes that are attached in original impeller - Splitter impeller. We assume that the impeller rotates with a constant angular velocity and the flow field around the impeller is incompressible and inviscid. So, a discrete vortex method (DVM) is used to model the centrifugal fan and to calculate the flow field. The force of each element on the blade is calculated by the unsteady Bernoulli equation. Lowson's method is used to predict the acoustic source. The splitter impeller changes the acoustic characteristics as well as performance. Two-splitter type impeller and splitter impeller which splitter locates in jet region are good for acoustic characteristics.

  • PDF

Color evolution of HBC 722 in the post-outburst phase

  • Baek, Giseon;Pak, Soojong;Green, Joel D.;Lee, Jeong-Eun;Bae, Kyoung Min;Jeon, Yiseul;Choi, Changsu;Im, Myungshin;Meschiari, Stefano
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.38 no.2
    • /
    • pp.70.2-70.2
    • /
    • 2013
  • We present collections of optical photometry for a pre-main sequence star HBC 722. It showed large amplitude optical outburst (${\Delta}V=4.7$ mag) in 2010 and classified as a FU Orionis type object. We have been observing HBC 722 from 2011 April to 2013 May, using Camera for QUasars in EArly uNiverse (CQUEAN) attached to the 2.1 m Otto Struve telescope at the McDonald Observatory. Time-series monitoring data (minute-scale interval) were obtained in SDSS r, i and z bands to see short-scale behaviors as well as trace the long-term brightness changes after the eruption in 2010. Interestingly, it started to brighten from 2011 early summer and became brighter than the first outburst peak in our 2013 May observation. We expect that the recovering phase would result from re-increase of disk accretion rate, might attribute to distinctive short-scale color features. In this presentation, we report long- and short-timescale optical behaviors of HBC 722 in the post-outburst phase.

  • PDF

Suggestion of the Bicycle Wear Design based on Active Senior Women's Preference (액티브 시니어 여성의 자전거의류 선호에 따른 디자인 제안)

  • Jung, Hee-Kyeong;Lee, Jeong-Ran
    • Fashion & Textile Research Journal
    • /
    • v.17 no.4
    • /
    • pp.604-612
    • /
    • 2015
  • This study investigates preferred bicycle wear designs that can satisfy active senior consumers. A survey was conducted on 50-60's women who periodically rode bicycles. The results indicated a preference for slim designs and red colors. Jacket designs preferences were for a tight fit for size tolerance, stand collar style, and elastic band details for cuff styles. Pants design preferences were for a whole band waist belt type with a tight fit style such as leggings in pants silhouette, zipper details on the side line and ankle length. They also preferred styles with pads attached to underpants in the pad style and the part of the back waist in the pocket position. The survey showed four kinds of jacket design drawings on an ordinal scale rating. Results indicated a preference for set-in variation jackets with the red and gray color combination. Finally, we demonstrated bicycle wear design suggestions. The jacket applied different armhole line colors connected to the sleeve to make the waist slimmer; in addition, stretchable material helped improve armpit part functionality.

Implementation and evaluation of the BCG measurement system for non-constrained health monitoring (무구속 건강모니터링을 위한 심탄도 계측 시스템 구현 및 평가)

  • Noh, Yun-Hong;Jeong, Do-Un
    • Journal of Sensor Science and Technology
    • /
    • v.19 no.1
    • /
    • pp.8-16
    • /
    • 2010
  • This research proposes measuring of BCG(ballistocardiogram) to monitor heart activities in a non-constrained environment, at home or work. Unlike with ECG, measuring BCG does not require the attachment of leads on the subject's body and allows signal measuring in a non-constrained state. It enables effective long-term monitoring of cardiac conditions. In this study a chair type BCG measurement system to continuous monitor the activity of the heart is implemented. The instrument consists of upper petal and ready for press of chair load cell sensor is attached to measure the change of the object's weight. In order to extract the output ballistic signal from the weight and force sensor signals. Beside the signal processing circuit for the digital conversion, the ballistic signal is detected using DAQ equipment. Signal processing algorithm including wavelet transforms for noise cancellation, template matching for normalization and peak detection in BCG is developed. ECG and BCG were concurrently measured to evaluate the performance of the system, and comparing the characteristics of the two signals verified the possibility of the system in non-constrained and nonconscious health monitoring.

Numerical Analysis on Heat Transfer Characteristics of a Heat Pipe Type Solar Thermal Receiver According to Internal Geometry Variation (고온 히트파이프식 태양열 흡수기의 내부형상 변화에 따른 열전달 특성의 수치해석)

  • Park, Young-Hark;Boo, Joon-Hong;Kang, Yong-Heack
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2008.05a
    • /
    • pp.165-168
    • /
    • 2008
  • A numerical analysis was conducted to predict the heat transfer characteristics of a solar receiver which is subject to very high heat fluxes and temperatures for solar thermal applications. The concentration ratio of the solar receiver ranges 1000 and the concentrated heat is required to be transported to a certain distance for specific applications. This study deals with a solar receiver according to internal geometry variation incorporating high-temperature heat pipe. The isothermal characteristics in the receiver section is of major concern. The diameter of the solar thermal receiver was 120 mm and the length was 400 mm and the angle of receiver end wall set $90^{\circ},\;60^{\circ},\;45^{\circ},\;30^{\circ}$. And the diameter of the heat pipe was 12.7 mm, 48 axial channels of the same dimensions were attached to the outer wall of the receiver with even spacing in the circumferential direction. The channels are changed to high-temperature sodium heat pipes. Commercial softwares were employed to deal with the radiative heat transfer inside the receiver cavity and the convection heat transfer along the channels. The numerical results are compared and analyzed from the view point of high-temperature solar receiver.

  • PDF

Development of In-Process Polishing Pressure Control System (실시간 폴리싱 압력 제어시스템 개발)

  • 오창진;전문식;김옥현
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.21 no.1
    • /
    • pp.109-115
    • /
    • 2004
  • Polishing process has been applied to get extremely fine surfaces, e.g., mirror surfaces such as optical mirrors, lens, molds and etc. Nowadays not only fine surface quality but also submicron order of dimensional accuracy is required for many applications. To meet the requirements polishing process should be provided with an active control of polishing pressure especially for automation of polishing process. In this paper a study on development of an active polishing pressure control system has been presented. A new type of tool assembly has been developed to facilitate the control. The tool is attached to an axis of a polishing machine with a coil spring and control of the polishing pressure is done by the position control of the axis, which needs no additional actuator. The polishing pressure is successfully measured by the measurement of the spring deformation. Control specifications were quantitatively considered by weighting functions and a controller was designed by using loop-shaping technique based on the no synthesis. Some experiments have been executed on a polishing machine with a PC-NC controller. It is shown that the results were coincident well with the theoretical analyses and satisfied the design specifications.

Thermal Performance Analysis of Glass Evacuated Solar Collector with a Finned Tube (내관에 휜을 부착한 진공관형 집열기의 열성능 해석)

  • Kim, Yong;Seo, Tae-Beom;Kang, Yong-Hyuk
    • Journal of the Korean Solar Energy Society
    • /
    • v.24 no.1
    • /
    • pp.39-45
    • /
    • 2004
  • The thermal performance of glass evacuated tube solar collectors with finned tubes is numerically modelled with code and investigated to see the effect of toe inner tube diameter and incidence angle. The solar collector consists of a two-layered glass tube and an inner tube. Finned tubes are used as the inner tube of the collector in order to improve the performance of the solar collector. Two strip-type fins are attached on the opposite sides of the inner tube surface. The fin is wide enough to be tightly fatted inside the glass tube. The results show that if the incidence angle is small, the effect of the tube diameters is not significant on the thermal performance and the outlet air temperature. If the incidence angle is large, however, the outlet air temperature and the performance increases as the inner tube diameter increases.

Burner combustion characteristics of hybrid type water mixing emulsion fuel (하이브리드형 물혼합 에멀젼 연료의 버너 특성)

  • Kim, Cheol-Jeong;Kim, Dong-Kwon;Park, Kweon-Ha
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.37 no.4
    • /
    • pp.308-315
    • /
    • 2013
  • Water emulsion technology has the problem of unstable combustion due to the rapid separation of water. To solve the problem, a hybrid mixing device was developed. The device attached on the burner was tested. As a result, the fuel consumption reduced to 12% in the similar condition of exhaust emissions and flame temperature, and 45.5%, 98.5% and 97.2% of NOx, CO, and smoke were reduced at the same inlet air and fuel flow rate.