• Title/Summary/Keyword: attached-type

Search Result 1,068, Processing Time 0.029 seconds

Utilizing vacuum bagging process to enhance bond strength between FRP sheets and concrete

  • Abdelal, Nisrin R.;Irshidat, Mohammad R.
    • Structural Engineering and Mechanics
    • /
    • v.72 no.3
    • /
    • pp.305-312
    • /
    • 2019
  • This paper investigates the effect of utilizing vacuum bagging process to enhance the bond behavior between fiber reinforced polymer (FRP) composites and concrete substrate. Sixty specimens were prepared and tested using double-shear bond test. The effect of various parameters such as vacuum, fiber type, and FRP sheet length and width on the bond strength were investigated. The experimental results revealed that utilizing vacuum leads to improve the bond behavior between FRP composites and concrete. Both the ultimate bond forces and the maximum displacements were enhanced when applying the vacuum which leads to reduction in the amount of FRP materials needed to achieve the required bond strength compared with the un-vacuumed specimens. The efficiency of the enhancement in bond behavior due to vacuum highly depends on the fiber type; using carbon fiber showed higher enhancement in the bond strength compared to the glass fiber when vacuum was applied. On the contrary, specimens with glass fiber showed higher enhancement in the maximum slippage compared to specimens with carbon fibers. Utilizing vacuum does not affect the debonding failure modes but lead to increase in the amount of attached concrete on the surface of the debonded FRP sheet.

Robust Design of Descending Lifeline Using Double Square Linkage Mechanism (이중 4절링크 기구를 이용한 완강기 강건 설계)

  • Park, Jung-Woo;Yun, Seul-Gi;Jung, Geun-Hak;Jung, Min-Hee;Kim, Sang-Hyun
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.20 no.6
    • /
    • pp.108-113
    • /
    • 2021
  • Recently, a new concept of a one-touch descending lifeline has been proposed to address the drawbacks of the conventional descending lifeline, which can be easily installed and quickly evacuated in the case of a fire emergency. All separate parts for escape are initially mounted in a box, and the link-type support is spread out of the window by pushing the handle attached to the box. In this study, the proposed double square linkage mechanism was redesigned, and its safety is verified by determining an appropriate moment of inertia of the link through finite element analysis using Abaqus. The shape and assembling method of the reel and speed controller were also modified such that the safety belt was simultaneously unfolded with link-type support. Finally, the feasibility of the proposed one-touch all-in-one descending lifeline was confirmed through fabrication.

Reliability Evaluation of ER Type Corrosion Sensor for Monitoring Corrosion of Piping System Under Accelerated Corrosion Environment (배관의 부식 상태 진단에 사용되는 ER 부식센서의 가속부식환경에서의 신뢰성 평가)

  • Hwang, Hyun-Kyu;Shin, Dong-Ho;Kim, Heon-Hui;Lee, Jung-Hyung
    • Corrosion Science and Technology
    • /
    • v.20 no.6
    • /
    • pp.403-411
    • /
    • 2021
  • In this study, the reliability of a commercial ER-type corrosion sensor was evaluated under an accelerated corrosion environment to verify its suitability for application in monitoring of ship's seawater piping system. A closed-loop pump piping testbed was designed and constructed to compare the wall thickness reduction of the pipe and the response from the sensor. The sensor was attached inside the pipe near the outlet of the pump that was exposed to a 3.5% NaCl solution with or without copper accelerated acetic acid (CASS). The results demonstrated that the presence of CASS significantly increased the corrosivity of the solution as well as the thickness reduction of the pipe, as expected. On the other hand, the corrosion products formed by the solution with CASS were thicker compared with those without CASS. The sensor response to temperature variation was found to be a clear linear relationship for the solution without CASS but there was a non-linear relationship where CASS was present.

Development of Stretch Sensors to Measure Thigh Motor Capacity (허벅지 운동능력 측정을 위한 스트레치 센서 개발)

  • Jang, Jinchul;Park, Jinhee;Kim, Jooyong
    • Journal of Fashion Business
    • /
    • v.25 no.5
    • /
    • pp.99-113
    • /
    • 2021
  • This study aimed to produce sensors for measuring thigh motor skills. A textile stretch sensor was manufactured using a CNT(Carbon Nano Tube) 0.1 wt% water SWCNT(Single-Walled Carbon Nano Tube) solution, and different designs were applied to increase the sensitivity of the sensor, and different GF(Gauge Factor) values were compared using UTM devices. The same design was applied to fabrics and weaves to observe changes in performance according to fibrous tissue, and the suitability of sensors was determined based on tensile strength, elongation, and the elongation recovery rate. Sensitivity was found to vary depending upon the design. Thus the manufactured sensor was attached to a pair of fitness pants as a prototype, divided into lunge position and squat position testing, and the stretch sensor was used to measure thigh movements. It was shown that stretch sensors used to measure thigh motor skills should have light and flexible features and that elongation recovery rates and tensile strength should be considered together. The manufactured stretch sensor may be applicable to various sports fields that use lower limb muscles, wearable healthcare products, and medical products for measuring athletic ability.

Developed a BLDC Motor for Driving a Commercial Vehicle Fan (상용차 팬 구동용 BLDC 모터 개발)

  • Shin, Dong-Hwa;Lee, Byung-Ho
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.25 no.4_2
    • /
    • pp.533-540
    • /
    • 2022
  • This paper is the research result of designing and developing a BLDC motor for driving a condenser fan, which is widely used in air conditioners of commercial vehicles and specially equipped vehicles, and produced with a target value. The design of the motor was carried out in the order of designing the electric and magnetic circuits after determining the motor specifications. The process was repeated with different set values until the designed target condition was satisfied, and the electric and magnetic field distributions were made to be equal by reflecting the characteristics of the material. As a structural feature of the motor, it is a rotating field type composed of multipoles, and has a structure in which a permanent magnet is attached to the surface of the rotor. The manufactured BLDC motor is a 3-phase square wave driving method, with a rated voltage of 24 [V], a rotational speed of 2,500 [rpm], a rated current of 10 [A], and a power consumption of 180 [W]. A microcontroller for driving and controlling the motor was also manufactured.

Stretchable Carbon Nanotube Composite Clays with Electrical Enhancers for Thermoelectric Energy Harvesting E-Skin Patches

  • Tae Uk Nam;Ngoc Thanh Phuong Vo;Jun Su Kim;Min Woo Jeong;Kyu Ho Jung;Alifone Firadaus Nurwicaksono Adi;Jin Young Oh
    • Elastomers and Composites
    • /
    • v.58 no.1
    • /
    • pp.11-16
    • /
    • 2023
  • Electronic skin (e-skin), devices that are mounted on or attached to human skin, have advanced in recent times. Yet, the development of a power supply for e-skin remains a challenge. A stretchable thermoelectric generator is a promising power supply for the e-skin patches. It is a safe and semi-permanent energy harvesting device that uses body heat for generating power. Carbon nanotube (CNT) clays are used in energy-harvesting e-skin patches. In this study, we report improved thermoelectric performance of CNT clays by using chemical doping and physical blending of thermoelectric enhancers. The n-type and p-type thermoelectric enhancers increase electrical conductivity, leading to increased power factors of the thermoelectric CNT clays. The blend of CNT clays and enhancers is intrinsically stretchable up to 50% while maintaining its thermoelectric property.

A Study on Male Panties for Urinary Incontinence (남성 요실금 팬티에 관한 연구)

  • Lee, Jung-Soon
    • Journal of the Korea Fashion and Costume Design Association
    • /
    • v.17 no.1
    • /
    • pp.39-52
    • /
    • 2015
  • This study aims to analyze the characteristics of the male products for urinary incontinence by examining the types and characteristics of those registered in KIPO (Korean Industrial Property Office). Additionally, the types and characteristics, especially for the cloth products and the pads, of male panties for urinary incontinence on the market are analyzed. Men in their 60s with minor symptoms were selected as the subjects to evaluate the wearability. The results are as follows. 11 male products for urinary incontinence, registered in KIPO, are structurally different from those for women by having a separate pocket mainly for absorption. There are one disposable type and 7 cloth types, and the cloth panties can be classified as either united or separable type depending on the detachability of pads from the panties. The types of the panties vary according to the position, shape, and size of the attached pads on normal male panties (boxer, briefs, drawers). The fabrics for the urinary incontinence are usually piled in 3 to 5 layers by having the most absorptive layer on the top, the next with deodorizing characteristics, and the bottom with the waterproof fabric as basics with some additional layers of antibiotic or breathable fabrics. From the wearability test, it has been determined that the panties are not distinguishable in external appearance and the fitness is also not a problem since the size varies as the normal panties. It has been evaluated that the fitness of the panties is an important factor since the pad should be worn in any form; the pad sewed in the middle of the panties was evaluated to be more wearable than having a long pad. In case of separable panties, when the pattern and fabric is similar to the functional panties and the options such as the thickness of the pads or detachability are given to the users, it tends to be more satisfactory.

  • PDF

The study on the buckling instability of the expansion tube type crash energy absorber by using the FEM (FEM을 이용한 확관형 충돌에너지 흡수부재의 좌굴불안전성에 관한 연구)

  • Choi, Won-Mok;Jung, Hyun-Sung;Kwon, Tae-Su
    • Proceedings of the KSME Conference
    • /
    • 2007.05a
    • /
    • pp.774-779
    • /
    • 2007
  • The crash energy absorbers used in the trains normally are classified into two types. The first is the structure type, which mainly used in not only the primary structure of train but also the crash energy absorbers at the critical accidents. The second is the module type, which just absorbs the crash energy independently and attached onto the structures of the trains. The expansion tube is widely used as the module type of the crash energy absorbers, especially in the trains that have a heavy mass. Since the crash energy is absorbed by means of expanding the tube in the radial direction, the features of the expansion tube have the uniform load during the compression. As the uniform load remains in sudden impact, the expansion tube is effective to decrease acceleration of passengers when the train accident occur. The buckling instability of the expansion tubes is affected by the boundary conditions, thickness and length of tube. In this study, the effects of the length and thickness of the expansion tubes under the arbitrary load on the buckling are studied using the ABAQUS/standard and ABAQUS/explicit, a commercial finite element analysis program, and then presents the guideline to design the expansion tubes. The analysis processes to compute the buckling load consist of the linear buckling analysis and the nonlinear post-buckling analysis. To analysis the nonlinear post-buckling analysis, the geometry imperfections are introduced by applying the linear buckling modes to nonlinear post-buckling analysis.

  • PDF

Development of the Hybrid CFFT Pile (FRP-콘크리트 합성말뚝의 개발)

  • Choi, Jin-Woo;Joo, Hyung-Joong;Nam, Jeong-Hun;Yoon, Soon-Jong
    • Journal of the Korean Society for Advanced Composite Structures
    • /
    • v.1 no.2
    • /
    • pp.20-28
    • /
    • 2010
  • In this paper, new type CFFT (Concrete Filled FRP Tube) was suggested in order to improve the flexural stiffness. Since the existing CFFT was produced by filament winding process, re-bar for concrete may be necessary in order to ensure structural safety under flexure re-bar. In comparison with existing type CFFT, new type CFFT was reinforced by circular shaped pultrusion FRP without re-bar. Filament winding FRP was attached to the outer layer of pultrusion FRP. Structural behavior of new type CFFT filled with concrete (HCFFT) was investigated by the mechanical property test for the component element and the FE analysis. Furthermore, compressive strength of the HCFFT member based on the equation suggested in previous studies.

  • PDF

Adhesive Polyurethane-based Capacitive Electrode for Patch-type Wearable Electrocardiogram Measurement System (패치형 웨어러블 심전도 측정 시스템을 위한 접착성 폴리우레탄 기반의 용량성 전극)

  • Lee, Jeong Su;Lee, Won Kyu;Lim, Yong Gyu;Park, Kwang Suk
    • Journal of Biomedical Engineering Research
    • /
    • v.35 no.6
    • /
    • pp.203-210
    • /
    • 2014
  • Wearable medical device has been a resurgence of interest thanks to the development of technology and propagation of smart phone in recent years. Various types of wearable devices have been introduced and available in market. Capacitive coupled electrode which measures electrocardiogram over cloth is able to be applied wearable device. In previous approaches of capacitive electrode, they need proper pressure for stable contact of the electrode to body surface. However, wearable device that gives pressure on body surface is not suitable for long-term monitoring. In this study, we proposed adhesive polyurethane-based capacitive electrode for patch-type wearable electrocardiogram (ECG) monitoring device. Self-adhesive polyurethane make the electrode and whole system be adhered to the surface of skin without any pressure. The patch-type system is consisted of analog filter, analog-to-digital converter and wireless transmission module and designed to be attached on the body as a patch. To validate the feasibility of the developed system, we measured ECG signal in stable and active state and extracted heart rate. Therefore, we observed skin response after long-term attachment for biocompatibility of the adhesive polyurethane and adhesive strength of it. The result shows the possibility of applying the developed system for ECG monitoring in real-life.