• Title/Summary/Keyword: atomic data

Search Result 1,431, Processing Time 0.026 seconds

Analysis of control rod driving mechanism nozzle rupture with loss of safety injection at the ATLAS experimental facility using MARS-KS and TRACE

  • Hyunjoon Jeong;Taewan Kim
    • Nuclear Engineering and Technology
    • /
    • v.56 no.6
    • /
    • pp.2002-2010
    • /
    • 2024
  • Korea Atomic Energy Research Institute (KAERI) has operated an integral effect test facility, the Advanced Thermal-Hydraulic Test Loop for Accident Simulation (ATLAS), with reference to the APR1400 (Advanced Power Reactor 1400) for tests for transient and design basis accidents simulation. A test for a loss of coolant accident (LOCA) at the top of the reactor pressure vessel (RPV) had been conducted at ATLAS to address the impact of the loss of safety injections (LSI) and to evaluate accident management (AM) actions during the postulated accident. The experimental data has been utilized to validate system analysis codes within a framework of the domestic standard problem program organized by KAERI in collaboration with Korea Institute of Nuclear Safety. In this study, the test has been analyzed by using thermal-hydraulic system analysis codes, MARS-KS 1.5 and TRACE 5.0 Patch 6, and a comparative analysis with experimental and calculation results has been performed. The main objective of this study is the investigation of the thermal-hydraulic phenomena during a small break LOCA at the RPV upper head with the LSI as well as the predictability of the system analysis codes after the AM actions during the test. The results from both codes reveal that overall physical behaviors during the accident are predicted by the codes, appropriately, including the excursion of the peak cladding temperature because of the LSI. It is also confirmed that the core integrity is maintained with the proposed AM action. Considering the break location, a sensitivity analysis for the nodalization of the upper head has been conducted. The sensitivity analysis indicates that the nodalization gave a significant impact on the analysis result. The result emphasizes the importance of the nodalization which should be performed with a consideration of the physical phenomena occurs during the transient.

The Association between Blood Selenium Level and the Gastric Diseases (혈중(血中) 셀레늄 농도(濃度)와 위장질환(胃臟疾患)의 관련성(關聯性))

  • Lee, Jong-Young;Kim, Doo-Hie;Park, Seoung-Kook
    • Journal of Preventive Medicine and Public Health
    • /
    • v.21 no.1 s.23
    • /
    • pp.172-182
    • /
    • 1988
  • To reveal the association between blood selenium level and the gastric diseases, 180 persons received the gastrofiberscopic examination at the outpatients department of the two university hospitals from July to September 1987, after the exclusion of the persons having the esophageal varix, were randomly selected. Their general characteristics such as age, sex and educational level and so on, were inverstigated. Five mi venous blood was collected from each subjects and stored at $0^{\circ}C$ in heparinized vaccum tube. The blood selenium level was measured by the flameless atomic absorption spectrophotometry. In the procedure of data analysis, five subjects having benign tumor and anomaly of the stomach, were also excluded. The mean blood selenium levels of the $155.5{\mu}g/{\ell}$ among gastritis cases, the $154.8{\mu}g/{\ell}$ gastric ulcer and the $133.0{\mu}g/{\ell}$ gastric malignancy were significantly lower(p<0.05) than that of the $173.3{\mu}g/{\ell}$ among normal controls. In men the mean blood selenium levels .among gastritis, gastric ulcer and gastric malignancy cases were significantly lower(p<0.05) than that among normal controls. In females, the mean blood selenium levels among gastritis and gastric maligancy cases were significantly lower(p<0.05) than that among normal controls($169.7{\mu}g/{\ell}$), but that among gastric ulcer cases($177.7{\mu}g/{\ell}$) was not significantly higher. In the logistic analysis, coefficient of the blood selenium level was -0.0436(p<0.05 : odds ratio 0.957) for gastritis, -0.0197(p=0.17 : 0.981) for gastric ulcer, -0.4876(p<0.05 : 0.614) for gastric malignancy and -0.0411(p<0.05 ; 0.960) for gastric diseases including the gastritis, the gastric ulcer and the gastric malignancy. These data support the hypothesis that the gastric diseases are to be associated with the low selenium level but, for the gastric ulcer, the further research is recommended.

  • PDF

Study on Mo(V) Species, Location and Adsorbates Interactions in MoH-SAPO-34 by Employing ESR and Electron Spin-Echo Modulation Spectroscopies (ESR, ESEM을 이용한 이온 교환된 MoH-SAPO-34에 대한 Mo의 화학종, 위치 및 흡착상호작용에 관한 연구)

  • Back, Gern-Ho;Jang, Chang-Ki;Ru, Chang-Kuk;Cho, Young-Hwan;So, Hyun-Soo;Kevan, Larry
    • Journal of the Korean Chemical Society
    • /
    • v.46 no.1
    • /
    • pp.26-36
    • /
    • 2002
  • A solid-state reaction of $MoO_3$ with as-synthesized H-SAPO-34 generated paramagnetic Mo(V) species. The dehydration resulted in weak Mo(V) species, and subsequent activation resulted in the formation of Mo(V) species such as $Mo(V)_{5c}$ and $Mo(V)_{6c}$ that are characterized by ESR. The data of ESR and ESEM show the oxomolybdenum species, to be $(MoO_2)^+$ or $(MoO)^{3+}$. The $(MoO_2)^+$ species seems to be more probable. Since H-SAPO-34 has a low framework negative charge, $(MoO)^{3+}$ with a high positive charge can not be easily stabilized. A solution reaction between the solution of silico-molybdic acid and calcined H-SAPO-34 resulted in only $(MoO_2)^+$ species. A rhombic ESR signal is observed on adsorption of $D_2O$, $CD_3OH$, $CH_3Ch_2OD$ and $ND_3$. The Location and coordination structure of Mo(V) species has been determined by three-pulse electron spin-echo modulation data and their simulations. After the adsorption of methanol, ethylene, ammonia, and water for MoH-SAPO-34, three molecules, one molecule, one and one molecule, respectively, are directly coordinated to $(MoO_2)^+)$.

A Study on the Comparison of HPGe Detector Response Data for Low Energy Photons Using MCNP, EGS, and ITS Codes (MCNP, EGS, ITS코드를 이용한 고순도 게르마늄 검출기의 저에너지 광자에 대한 반응 비교연구)

  • Kim, Soon-Young;Kim, Jong-Kyung;Kim, Jong-Oh;Kim, Bong-Hwan
    • Journal of Radiation Protection and Research
    • /
    • v.21 no.2
    • /
    • pp.125-129
    • /
    • 1996
  • The energy response of HPGe detector for low energy Photons was determined by using three Monte Carlo codes. MCNP4A. EGS4, and CYLTRAN in ITS3. In this study. bare HPGe detector$(100 mm^2{\times}10mm)$ was used and a pencil beam was incident perpendicularly on the center of the detector surface. The photopeak efficiency, $K_{\alpha}$ and $K_{\beta}$ escape fractions were calculated as a function of incident X-ray energies ranging from 12 to 60 keV in 2-keV increments. Since the Compton. elastic. ana penetration fraction were negligible in this energy range. they were ignored in the calculation. Although MCNP. EGS, and CYLTRAN codes calculated slightly different energy response of HPGe detector for low energy Photons, it appears that the three Monte Carlo codes can Predict the low energy Photon scattering Processes accurately. The MCNP results, which are generally known as to be less accurate at low energy ranges than the EGS and ITS results. are comparable to the results of EGS and ITS and are applicable to the calculation of the low energy response data of a detector.

  • PDF

Self-Diagnosis of Damage in Carbon Fiber Reinforced Composites Using Electrical Residual Resistance Measurement (잉여 전기 저항 측정을 이용한 탄소 섬유 강화 복합재의 파손 측정)

  • Kang, Ji-Ho
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.29 no.4
    • /
    • pp.323-330
    • /
    • 2009
  • The objective of this research was to develop a practical integrated approach using extracted features from electrical resistance measurements and coupled electromechanical models of damage, for in-situ damage detection and sensing in carbon fiber reinforced plastic(CFRP) composites. To achieve this objective, we introduced specific known damage (in terms of type, size, and location) into CFRP laminates and established quantitative relationships with the electrical resistance measurements. For processing of numerous measurement data, an autonomous data acquisition system was devised. We also established a specimen preparation procedure and a method for electrode setup. Coupon and panel CFRP laminate specimens with several known damage were tested. Coupon specimens with various sizes of artificial delaminations obtained by inserting Teflon film were manufactured and the resistance was measured. The measurement results showed that increase of delamination size led to increase of resistance implying that it is possible to sense the existence and size of delamination. A quasi-isotropic panel was manufactured and electrical resistance was measured. Then three different sizes of holes were drilled at a chosen location. The panel was prepared using the established procedures with six electrode connections on each side making a total of twenty-four electrodes. Vertical, horizontal, and diagonal pairs of electrodes were chosen and the resistance was measured. The measurement results showed the possibility of the established measurement system for an in-situ damage detection method for CFRP composite structures.

A Study for the Optimum pH of Hydrogen Production in Anaerobic Batch Reactor (혐기성 회분반응기에서 수소생산 시 최적 pH 산정에 관한 연구)

  • Jun, Yoon-Sun;Park, Jong-Il;Yu, Seung-Ho;Lee, Tae-Jin
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.29 no.1
    • /
    • pp.54-61
    • /
    • 2007
  • The influences of pH were investigated for anaerobic hydrogen gas production under the constant pH condition ranged from pH 3 to 10. Carbon dioxide and hydrogen gas were main components of the gas but methane was not detected in the produced gas when sucrose was added in enrichment medium. When the modified Gompartz equation was applied for the statistical analysis of experimental data, a hydrogen production potential and maximum gas production rate at pH 5 were 1,182 mL and 112.46 mL/g dry wt biomass/hr. The hydrogen conversion ratio was 22.56%. The butyrate/acetate ratios at pH 5 and pH 6 are 1.63 and 0.38. Higher butyrate/acetate ratio produced more hydrogen gas generation. The Haldane equation model was used to find the optimum pH and fitted well with the experimental data$(r^2=0.98)$. The optimum pH and specific hydrogen production were 5.5 and 119.61 mL/g VSS/h.

Study on Characteristics of Dose Distribution in Tissue of High Energy Electron Beam for Radiation Therapy (방사선 치료용 고에너지 전자선의 조직 내 선량분포 특성에 관한 연구)

  • Na, Soo-Kyung
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.14 no.1
    • /
    • pp.175-186
    • /
    • 2002
  • The purpose of this study is directly measure and evaluate about absorbed dose change according to nominal energy and electron cone or medical accelerator on isodose curve, percentage depth dose, contaminated X-ray, inhomogeneous tissue, oblique surface and irradiation on intracavitary that electron beam with high energy distributed in tissue, and it settled standard data of hish energy electron beam treatment, and offer to exactly data for new dote distribution modeling study based on experimental resuls and theory. Electron beam with hish energy of $6{\sim}20$ MeV is used that generated from medical linear accelerator (Clinac 2100C/D, Varian) for the experiment, andwater phantom and Farmer chamber md Markus chamber und for absorbe d dose measurement of electron beam, and standard absorbed dose is calculated by standard measurements of International Atomic Energy Agency(IAEA) TRS 277. Dose analyzer (700i dose distribution analyzer, Wellhofer), film (X-OmatV, Kodak), external cone, intracavitary cone, cork, animal compact bone and air were used for don distribution measurement. As the results of absorbed dose ratio increased while irradiation field was increased, it appeared maximum at some irradiation field size and decreased though irradiation field size was more increased, and it decreased greatly while energy of electron beam was increased, and scattered dose on wall of electron cone was the cause. In percentage depth dose curve of electron beam, Effective depth dose(R80) for nominal energy of 6, 9, 12, 16 and 20 MeV are 1.85, 2.93, 4.07, 5.37 and 6.53 cm respectively, which seems to be one third of electron beam energy (MeV). Contaminated X-ray was generated from interaction between electron beam with high energy and material, and it was about $0.3{\sim}2.3\%$ of maximum dose and increased with increasing energy. Change of depth dose ratio of electron beam was compared with theory by Monte Carlo simulation, and calculation and measured value by Pencil beam model reciprocally, and percentage depth dose and measured value by Pencil beam were agreed almost, however, there were a little lack on build up area and error increased in pendulum and multi treatment since there was no contaminated X-ray part. Percentage depth dose calculated by Monte Carlo simulation appeared to be less from all part except maximum dose area from the curve. The change of percentage depth dose by inhomogeneous tissue, maximum range after penetration the 1 cm bone was moved 1 cm toward to surface then polystyrene phantom. In case of 1 cm and 2 cm cork, it was moved 0.5 cm and 1 cm toward to depth, respectively. In case of air, practical range was extended toward depth without energy loss. Irradiation on intracavitary is using straight and beveled type cones of 2.5, 3.0, 3.5 $cm{\phi}$, and maximum and effective $80\%$ dose depth increases while electron beam energy and size of electron cone increase. In case of contaminated X-ray, as the energy increase, straight type cones were more highly appeared then beveled type. The output factor of intracavitary small field electron cone was $15{\sim}86\%$ of standard external electron cone($15{\times}15cm^2$) and straight type was slightly higher then beveled type.

  • PDF

A 3-D Measuring System of Thermoluminescence Spectra and Thermoluminescence of CaSO4 : Dy, P (열자극발광 스펙트럼의 3차원 측정 장치와 CaSO4 : Dy, P의 열자극발광)

  • Lee, Jung-Il;Moon, Jung-Hak;Kim, Douk-Hoon
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.6 no.2
    • /
    • pp.71-75
    • /
    • 2001
  • In this paper, a three-dimensional measuring system of thermoluminescence(TL) spectra based on temperature, wavelength and luminescence intensity was introduced. The system was composed of a spectrometer, temperature control unit for thermal stimulation, photon detector and personal computer for control the entire system. Temperature control was achieved by using feedback to ensure a linear-rise in the sample temperature. Digital multimeter(KEITHLEY 195A) measures the electromotive force of Copper-Constantan thermocouple and then transmits the data to the computer through GPIB card. The computer converts this signal to temperature using electromotive force-temperature table in program, and then control the power supply through the D/A converter. The spectrometer(SPEX 1681) is controlled by CD-2A, which is controlled by the computer through RS-232 communication port. For measuring the luminescence intensity during the heating run, the electrometer(KEITHLEY 617) measures the anode current of photomultiplier tube(HAMAMATSU R928) and transmits the data to computer through the A/D converter. And, we measured and analyzed thermoluminescence of $CaSO_4$ : Dy, P using the system. The measuring range of thermoluminescence spectra was 300K-575K and 300~800 nm, $CaSO_4$ : Dy. P was fabricated by the Yamashita's method in Korea Atomic Energy Research Institute(KAERI) for radiation dosimeter. Thermoluminesce spectra of the $CaSO_4$ : Dy, P consist of two main peak at temperature of $205^{\circ}C$, wavelength 476 nm and 572 nm and with minor ones at 658 nm and 749 nm.

  • PDF

Phase Analysis of Mechanically Alloyed $\sigma$-VFe Alloy Powders by Neutron and X-ray Diffraction (기계적 합금화한 $\sigma$-VFe합금의 중성자 및 X선 회절에 의한 상분석)

  • Lee, Chung-Hyo;Jo, Jae-Mun;Lee, Sang-Jin;Sim, Hae-Seop;Lee, Chang-Hui
    • Korean Journal of Materials Research
    • /
    • v.11 no.8
    • /
    • pp.661-665
    • /
    • 2001
  • The mechanical alloying (MA) effect in $\sigma$-VFe intermetallic compound was studied by neutron and X-ray diffraction. The structure of MA $\sigma$-VFe powders were characterized by the X- ray diffraction with Cu- $K\alpha$ radiation and neutron diffraction with monochromatic neutrons of $1.835\AA$ using a high resolution powder diffractometer (HRPD). Mechanical alloying of $\sigma$-VFe compound gives rise to a dramatic structural change. After 60 hours of MA, the Fe-Fe distribution of the $\sigma$- phase VFe tetragonal structure with 30 atoms in a unit cell is found to change into that of the $\sigma$-(V,Fe) solid solution with bcc structure, which is a stable phase at elevated temperature above $1200^{\circ}C$. A comparison of X-ray diffraction data for the $\alpha$-phase has been also made with the corresponding neutron diffraction data. The (101) and (111) diffraction peaks of the $\sigma$-phase was clearly observed only in neutron diffraction pattern, which is believed to be a characteristic feature due to the chemical atomic ordering of $\sigma$- VFe phase.

  • PDF

Organ Weights and Splenocytic Apoptosis in γ-irradiated Korean Dark-Striped Field Mice, Apodemus Agrarius Coreae (방사선 조사된 국내 야생 등줄쥐 (Apodemus agrarius coreae) 장기무게 및 비장세포 세포고사)

  • Joo, Hyunjin;Choi, Hoon;Yang, Kwang-hee;Keum, Dong-kwon;Kim, Hee sun
    • Journal of Radiation Protection and Research
    • /
    • v.40 no.3
    • /
    • pp.168-173
    • /
    • 2015
  • The present investigation was planned to estimate potential possibility of striped field mice, Apodemus agrarius coreae (A. a. coreae), as a biological dosimeter in radio-environmental ecology. We bred captured wild A. a. coreae at laboratory and classified taxonomically based on external, cranial and tooth characters. Organ weights and splenocytic apoptosis were observed in order to establish a basic data on radiation biology of A. a. coreae (male, 40 weeks old). The biological effects was observed at 24hrs following irradiation (doses : 0, 0.5, 1, 2 Gy, dose rate : $0.8Gymin^{-1}$, $^{137}Cs$). Only thymus weights was significantly decreased. Splenocytic apoptosis was increased after irradiation. But splenocytic apoptosis was decreased in 0.5 Gy ${\gamma}$-irradiated mice compared to those of 0, 1, 2 Gy (P < 0.05). These data suggested that events in thymus and spleen of Korean dark-striped field mice, A. a. coreae THOMAS, could be a potential radio-biological indicator in human environments.