• Title/Summary/Keyword: asymmetric building

Search Result 89, Processing Time 0.019 seconds

The effect of mass eccentricity on the torsional response of building structures

  • Georgoussis, George K.;Mamou, Anna
    • Structural Engineering and Mechanics
    • /
    • v.67 no.6
    • /
    • pp.671-682
    • /
    • 2018
  • The effect of earthquake induced torsion, due to mass eccentricities, is investigated with the objective of providing practical design guidelines for minimizing the torsional response of building structures. Current code provisions recommend performing three dimensional static or dynamic analyses, which involve shifting the centers of the floor masses from their nominal positions to what is called an accidental eccentricity. This procedure however may significantly increase the design cost of multistory buildings, due to the numerous possible spatial combinations of mass eccentricities and it is doubtful whether such a cost would be justifiable. This paper addresses this issue on a theoretical basis and investigates the torsional response of asymmetric multistory buildings in relation to their behavior when all floor masses lie on the same vertical line. This approach provides an insight on the overall seismic response of buildings and reveals how the torsional response of a structure is influenced by an arbitrary spatial combination of mass eccentricities. It also provides practical guidelines of how a structural configuration may be designed to sustain minor torsion, which is the main objective of any practicing engineer. A parametric study is presented on 9-story common building types having a mixed-type lateral load resisting system (frames, walls, coupled wall bents) and representative heightwise variations of accidental eccentricities.

Predicting the seismic behavior of torsionally-unbalanced RC building using resistance eccentricity

  • Abegaz, Ruth A.;Kim, In-Ho;Lee, Han Seon
    • Structural Engineering and Mechanics
    • /
    • v.83 no.1
    • /
    • pp.1-17
    • /
    • 2022
  • The static design approach in the current code implies that the inherent torsional moment represents the state of zero inertial torsional moments at the center of mass (CM). However, both experimental and analytical results prove the existence of a large amount of the inertial torsional moment at the CM. Also, the definition of eccentricity by engineers, which is referred to as the resistance eccentricity, is defined as the distance between the center of mass and the center of resistance, which is conceptually different from the static eccentricity in the current codes, defined as the arm length about the center of rotation. The difference in the definitions of eccentricity should be made clear to avoid confusion about the torsion design. This study proposed prediction equations as a function of resistance eccentricity based on a resistance eccentricity model with advantages of (1) the recognition of the existence of torsional moment at the CM, (2) the avoidance of the confusion by using resistance eccentricity instead of the design eccentricity, and (3) a clear relationship of applied inertial forces at the CM and resisting forces. These predictions are compared with the seismic responses obtained from time-history analyses of a five-story building structure under moderate and severe earthquakes. Then, the trend of the resistance eccentricity corresponding to the maximum edge drift is investigated for elastic and inelastic responses. The comparison given in this study shows that these prediction equations can serve as a useful reference for the prediction in both the elastic and the inelastic ranges.

Dispersion Effects of Wave Force on Interlocking Caisson Breakwater with Shear-Key (전단키형 인터로킹 케이슨 방파제의 파력분산효과)

  • Song, Sung Hoon;Park, Min Su;Jeong, Youn Ju;Hwang, Yoon Koog
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.39 no.1
    • /
    • pp.195-201
    • /
    • 2019
  • Long caisson breakwaters can improve the structural safety of a caisson due to the wave dispersion effect which reduces the average wave force acting on one caisson. However, in order to make long caissons, there are many manufacturing and construction limitations. Recently, interlocking caisson systems, which are to form a long caisson by interlocking individual caissons with adjacent caissons, have been much attention. In the present study, a interlocking caisson system with shear-keys was proposed and the wave dispersion effect according to the shear-key was evaluated analytically. As a result, (1) Because of the asymmetric shape of the interlocking caisson, the structure behavior and the wave dispersion effect of one are also asymmetric. (2) The wave dispersion effect is more influenced by the distribution and characteristics of wave acting on each caisson rather than the shape of the shear-key such as shear angle, height, shear length ratio. (3) The interlocking caisson breakwater is almost the same behavior and wave dispersion effect as a fully integrated breakwater.

Proposal of a Incremental Modal Pushover Analysis (IMPA)

  • Bergami, A.V.;Forte, A.;Lavorato, D.;Nuti, C.
    • Earthquakes and Structures
    • /
    • v.13 no.6
    • /
    • pp.539-549
    • /
    • 2017
  • Existing reinforced concrete frame buildings designed for vertical loads could only suffer severe damage during earthquakes. In recent years, many research activities were undertaken to develop a reliable and practical analysis procedure to identify the safety level of existing structures. The Incremental Dynamic Analysis (IDA) is considered to be one of the most accurate methods to estimate the seismic demand and capacity of structures. However, the executions of many nonlinear response history analyses (NL_RHA) are required to describe the entire range of structural response. The research discussed in this paper deals with the proposal of an efficient Incremental Modal Pushover Analysis (IMPA) to obtain capacity curves by replacing the nonlinear response history analysis of the IDA procedure with Modal Pushover Analysis (MPA). Firstly, In this work, the MPA is examined and extended to three-dimensional asymmetric structures and then it is incorporated into the proposed procedure (IMPA) to estimate the structure's seismic response and capacity for given seismic actions. This new procedure, which accounts for higher mode effects, does not require the execution of complex NL-RHA, but only a series of nonlinear static analysis. Finally, the extended MPA and IMPA were applied to an existing irregular framed building.

Seismic Performance Level Criteria and Evaluation Methods (기존시설물 내진성능평가를 위한 평가항목 분류체계와 평가방법)

  • 김남희
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2000.10a
    • /
    • pp.251-260
    • /
    • 2000
  • Seismic performance evaluation systems require rational classification of structure systems, proper evaluation criteria, and their scoring index for synthesis. Current seismic performance systems need expert judgments based on collection of available data, approximate analysis of important items, and various scoring system. This study presents a three-step seismic performance evaluation system for building structures in Korea. Each evaluation step determines the seismic performance and the method depends on the degree of refinement of analysis. The preliminary step evaluation involves the global attributes of structures such as vertical irregularity, asymmetric plan, redundancy, and age of structures. The second step requires an elastic analysis for estimation of forces acting on critical sections and checks the strength and ductility. The final step requires inelastic capacity of structures. Each stephas own evaluation scheme with proper weighing factor dependent on the importance and consequence. This study applies the fuzzy theory to a scoring method that synthesizes the individual quantity to a representative value.

  • PDF

A Study of Cogging Torque Reduction depending on Notch Position of Single Phase BLDC Motor Stator (단상 BLDC 전동기 고정자 노치 위치에 따른 코깅토크 저감에 관한 연구)

  • Kam, Seung-Han;Jung, Tae-Uk
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.17 no.3
    • /
    • pp.113-121
    • /
    • 2014
  • This paper presents a optimization design of 10[W] single phase BLDC motor applied Notch shape. Cogging Torque causes noise, vibration and torque ripple so notched stator is proposed in this paper. Firstly, a single phase BLDC motor needs applying aymmetric air-gap shape because this type motor cannot help having dead-point which is zero torque position. However, using asymmetric air-gap structure causes cogging torque increase. Therefore, this paper proposes the notch shape structure. Notch shape structure has some advantages; low cost, easy to apply. There are 4 optimal factors selected in optimization process, which are position and size of notches. Through building a prototype, the result of FE analysis and the experimental measurement value are compared each other and then vailidity and utility of simulation will be verified.

Building Remote Integrated System Implementation Using Dynamic IP (유동 IP를 이용한 빌딩 원격 통합시스템 구현)

  • Kim, Jin-Sub
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2006.10d
    • /
    • pp.506-511
    • /
    • 2006
  • 빌딩 원격 통합관리는 광역에 걸쳐 분포되어 있는 빌딩의 자동화 시스템의 통합을 의미하며, 이를 통해 작업의 일관성을 유지하며 생산성을 향상시키고 각각의 설비에 대한 정보를 일원화할 수 있다. 빌딩 자동화 시스템의 통합을 위해서 프로토콜 개방이 중요하지만, 국내의 자동화 시스템 제작업체에서는 프로토콜 개방을 하지 않고 있다. 또한 통신 프로토콜이 분석되었다고 하더라도 연결 가능한 Device에 따라 수집할 수 있는 데이터의 종류에는 한계가 있을 수 있다. 본 논문에서는 빌딩 원격 통합관리를 구현할 수 있는 유동 IP를 이용한 빌딩 원격 통합관리 시스템의 구축 방안을 제시하고, 관리비를 줄일 수 있는 통합 운영 방법과 기업용 전용회선대비 유동 IP를 이용한 ADSL(Asymmetric Digital Subscriber Line)의 통신비를 평가하였다.

  • PDF

Inelastic response of code-designed eccentric structures subject to bi-directional loading

  • Chandler, A.M.;Correnza, J.C.;Hutchinson, G.L.
    • Structural Engineering and Mechanics
    • /
    • v.5 no.1
    • /
    • pp.51-58
    • /
    • 1997
  • The influence of bi-directional earthquake-induced loading on eccentric (plan-asymmetric) building systems has been investigated. In the first part of the study, comparisons have been made with equivalent results from uni-directional studies. The results are important in developing analytical models appropriate to the formulation of design recommendations. It is concluded that for valid comparisons, both perpendicular horizontal earthquake components must be considered when using models with transversely-orientated elements. In the second part of the study, an assessment has been made of a simplified, unidirectional (lateral) design approach. For stiffness-eccentric systems, the latter approach gives accurate and reasonably conservative estimates of the critical flexible-edge deformation, but may under estimate the stiff-edge element ductility demand by a factor of two in the short-period range.

Preliminary Structural Design of Wall-Frame Systems for Optimum Torsional Response

  • Georgoussis, George K.
    • International Journal of Concrete Structures and Materials
    • /
    • v.11 no.1
    • /
    • pp.45-58
    • /
    • 2017
  • Recent investigations have pointed out that current code provisions specifying that the stiffness of reinforced concrete elements is strength independent, and therefore can be estimated prior to any strength assignment, is incorrect. A strength allocation strategy, suitable for preliminary structural design of medium height wall-frame dual systems, is presented for allocating strength in such buildings and estimating the dependable rigidities. The design process may be implemented by either the approximate continuous approach or the stiffness matrix method. It is based on the concept of the inelastic equivalent single-degree-of-freedom system which, the last few years, has been used to implement the performance based seismic design. The aforesaid strategy may also be used to determine structural configurations of minimum rotation distortion. It is shown that when the location of the modal centre of rigidity, as described in author's recent papers, is within a close distance from the mass axis the torsional response is mitigated. The methodology is illustrated in ten story building configurations, whose torsional response is examined under the ground motion of Kobe 1995, component KJM000.

Optimal input cross-power spectra in shake table testing of asymmetric structures

  • Ammanagi, S.;Manohar, C.S.
    • Earthquakes and Structures
    • /
    • v.9 no.5
    • /
    • pp.1115-1132
    • /
    • 2015
  • The study considers earthquake shake table testing of bending-torsion coupled structures under multi-component stationary random earthquake excitations. An experimental procedure to arrive at the optimal excitation cross-power spectral density (psd) functions which maximize/minimize the steady state variance of a chosen response variable is proposed. These optimal functions are shown to be derivable in terms of a set of system frequency response functions which could be measured experimentally without necessitating an idealized mathematical model to be postulated for the structure under study. The relationship between these optimized cross-psd functions to the most favourable/least favourable angle of incidence of seismic waves on the structure is noted. The optimal functions are also shown to be system dependent, mathematically the sharpest, and correspond to neither fully correlated motions nor independent motions. The proposed experimental procedure is demonstrated through shake table studies on two laboratory scale building frame models.