An assessment of code designed, torsionally stiff, asymmetric steel buildings under strong earthquake excitations

  • Kyrkos, M.T.;Anagnostopoulos, S.A.
    • Earthquakes and Structures
    • /
    • v.2 no.2
    • /
    • pp.109-126
    • /
    • 2011
  • The inelastic earthquake response of non-symmetric, braced steel buildings, designed according to the EC3 (steel structures) and EC8 (earthquake resistant design) codes, is investigated using 1, 3 and 5-story models, subjected to a set of 10, two-component, semi-artificial motions, generated to match the design spectrum. It is found that in these buildings, the so-called "flexible" edge frames exhibit higher ductility demands and interstory drifts than the "stiff" edge frames. We note that the same results were reported in an earlier study for reinforced concrete buildings and are the opposite of what was predicted in several other studies based on the over simplified, hence very popular, one-story, shear-beam type models. The substantial differences in such demands between the two sides suggest a need for reassessment of the pertinent code provisions. In a follow up paper, a design modification will be introduced that can lead to a more uniform distribution of ductility demands in the elements of all building edges. This investigation is another step towards more rational design of non-symmetric steel buildings.

Mitigating the effect of urban layout on torsion of buildings caused by infill walls

  • Noorifard, Azadeh;Tabeshpour, Mohammad Reza;Saradj, Fatemeh Mehdizadeh
    • Earthquakes and Structures
    • /
    • v.23 no.2
    • /
    • pp.151-168
    • /
    • 2022
  • Torsion is one of the most important causes of building collapse during earthquakes. Sometimes, despite the symmetric form of the building, infill walls disturb the symmetry of the lateral resisting system. The purpose of this research is to investigate the effect of urban layout on developing torsion caused by infill walls. For this purpose, a typological study was conducted based on the conditions of perimeter walls on 364 buildings and then 9 cases were selected. The dimensions of the selected buildings are constant and the conditions of the perimeter walls including facades with openings and cantilevered facades are variable. The selected buildings with 60 different layouts of infill walls were analyzed and the behavior of each one was evaluated based on the torsional irregularity criteria of seismic codes. The results of the analyses showed that if the perimeter walls of a building are symmetric, asymmetric interior walls will not be important in developing torsion and effective parameters in symmetry of the perimeter infill walls are the number of walls, area of openings, aspect ratio, and construction details. Finally, architectural solutions to mitigate the torsional effects of infill walls were proposed for buildings with solid infill walls on some sides, for buildings where the perimeter walls of one side are on the cantilevered part, and for buildings where the perimeter walls of two adjacent sides are on the cantilevered part. In three-sided buildings, where two adjacent façades are cantilevered, it is often impossible to use the potential of the infill walls.

A Study on The Risk on the Non-payment of Monthly Rent of Seoul Office Market in the Framework of Asymmetric Information (정보비대칭 관점에서 서울 오피스 시장의 월세미납리스크에 관한 연구)

  • Kim, Sung-Nam;Choi, Young-Sang;Koh, Sung-Soo
    • The Journal of the Korea Contents Association
    • /
    • v.15 no.7
    • /
    • pp.531-543
    • /
    • 2015
  • Benjamin, Lusht, and Shilling(1998) suggested that the level of deposit can be used as a tool to resolve the problem of adverse selection by the leaseholder under the circumstance of information asymmetry. In this respect, this research aims to verify how the level of deposit and monthly rent mitigate the problem of information asymmetry existing in the office market in Seoul. So far, the analysis of the office market in Seoul has been difficult due to the fixed rate of deposit and monthly rent. This research attempts to adopt the concept of occupancy cost, a global standard indicator that would replace the default risk of monthly payment for analyzing the market. As a result of a series of empirical analysis, the lessors tend to add about 9 percent of risk premium to the occupancy cost to hedge against the default risk of monthly payment. It allows for estimating at what extent one should reflect the leaseholder's default risk of monthly payment for operating deposit and monthly rent in the office building lease market.

Stress interactions between two asymmetric noncircular tunnels

  • La, You-Sung;Kim, Bumjoo;Jang, Yeon-Soo;Choi, Won-Hyuk
    • Geomechanics and Engineering
    • /
    • v.15 no.3
    • /
    • pp.869-877
    • /
    • 2018
  • The continually growing demand for underground space in dense urban cities is also driving the demand for underground highways. Building the underground highway tunnel, however, can involve complex design and construction considerations, particularly when there exists divergence or convergence in the tunnel. In this study, interaction between two asymmetric noncircular tunnels-that is, a larger main tunnel and a smaller tunnel diverging from the main tunnel, was investigated by examining the distributions of the principal stresses and the strength/stress ratio for varying geometric conditions between the two tunnels depending on diverging conditions using both numerical analysis and scale model test. The results of numerical analysis indicated that for the $0^{\circ}$, $30^{\circ}$, $60^{\circ}$ diverging directions, the major principal stress showed an initial gradual decrease and then a little steeper increase with the increased distance from the left main tunnel, except for $90^{\circ}$ where a continuous drop occurred, whereas the minor principal stress exhibited an opposite trend with the major principal stresses. The strength/stress ratio showed generally a bell-shaped but little skewed to left distribution over the distance increased from the left larger tunnel, similarly to the variation of the minor principal stress. For the inter-tunnel distance less than 0.5D, the lowest strength/stress ratio values were shown to be below 1.0 for all diverging directions ($0^{\circ}$, $30^{\circ}$, $60^{\circ}$ and $90^{\circ}$). The failure patterns observed from the model test were found to be reasonably consistent with the results of numerical analysis.

Full-scale tests and finite element analysis of arched corrugated steel roof under static loads

  • Wang, X.P.;Jiang, C.R.;Li, G.Q.;Wang, S.Y.
    • Steel and Composite Structures
    • /
    • v.7 no.4
    • /
    • pp.339-354
    • /
    • 2007
  • Arched Corrugated Steel Roof (ACSR) is a kind of thin-walled steel shell, composing of arched panels with transverse small corrugations. Four full-scale W666 ACSR samples with 18m and 30m span were tested under full and half span static vertical uniform loads. Displacement, bearing capacities and failure modes of the four samples were measured. The web and bottom flange in ACSR with transverse small corrugations are simplified to anisotropic curved plates, and the equivalent tensile modulus, shear modulus and Poisson's ratio of 18m span ACSR were measured. Two 18 m-span W666 ACSR samples were analyzed with the Finite Element Analysis program ABAQUS. Base on the tests, the limit bearing capacity of ACSR is low, and for half span loading, it is 74-75% compared with the full span loading. When the testing load approached to the limit value, the bottom flange at the sample's bulge place locally buckled first, and then the whole arched roof collapsed suddenly. If the vertical loads apply along the full span, the deformation shape is symmetric, but the overall failure mode is asymmetric. For half span vertical loading, the deformation shape and the overall failure mode of the structure are asymmetric. The ACSR displacement under the vertical loads is large and the structural stiffness is low. There is a little difference between the FEM analysis results and testing data, showing the simplify method of small corrugations in ACSR and the building techniques of FEM models are rational and useful.

A Comparative Study on the Architectural Characteristics of Gunjajeong and Gyejeong (군자정(君子亭)과 계정(溪亭)의 건축특성 비교 연구)

  • Jang, Sun-Joo
    • Journal of the Korean housing association
    • /
    • v.25 no.6
    • /
    • pp.57-66
    • /
    • 2014
  • With regard to the pavilion buildings of Imcheonggak Gunjajeong and Donglakdang Gyejeong that are located within residential areas, this study focused on the construction background, the building owner's circumstances and the location environment of these buildings, and attempted to derive the architectural characteristics presented by these two pavilion buildings and, through this, to grasp the architect's intention of plan. The results of this study are as follows. With regard to Gunjajeong, it could be confirmed that, first, it is located in a propitious site and took the composition that follows the family ritual standards for the family rituals of the scholar-gentry class and opens to visitor access, and second, the floor height of the site and interior space was designed so that Munpilbong on the south and the Sarangchae on the west, and the Sadang on the east can be connected visually, and third, the authority and dignity of the head family were built through the symmetric 丁-shaped plane figure, the wide partition module, the form-centered building, and the hierarchical composition of the roof. On the other hand, with regard to Gyejeong, it could be confirmed that, first, it is located along the stream of Jagye valley that has no mountains in the front and in the back and took the composition that put the name symbolizing Taoist thoughts on the surrounding natural environment and was closed to visitor access but opens to nature, and second, with Jagye and Jagye surroundings as the main landscape, it built the concept of intended landscape that symbolizes the Taoist thoughts by giving names not only simply to the visible objects but also to surrounding rocks, and third, the asymmetric ㄱ-shaped plane composed a yard-centered space rather than emphasizing the shape, and connected the part of the plane with Jagye so as to be embodied as a personal inner self-perfecting place that closely communicates only with nature away from the mundane world.

Inelastic Seismic Response of Asymmetric-Plan Self-Centering Energy Dissipative Braced Frames (비정형 셀프센터링 가새골조의 비탄성 지진응답)

  • Kim, Jin-Koo;Christopoulos, C.;Choi, Hyun-Hoon
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.12 no.4
    • /
    • pp.35-44
    • /
    • 2008
  • A self-centering energy-dissipative(SCED) bracing system has recently been developed as a new seismic force resistant bracing system. The advantage of the SCED brace system is that, unlike other comparable advanced bracing systems that dissipate energy such as the buckling restrained brace(BRB) system, it has a self-centering capability that reduces or eliminates residual building deformations after major seismic events. In order to investigate the effects of torsion on the SCED brace and BRB systems, nonlinear time history analyses were used to compare the responses of 3D model structures with three different amounts of frame eccentricity. The results of the analysis showed that the interstory drifts of SCED braced frames are more uniform than those of BRB frames, without regard to irregularity. The residual drift and residual rotation responses tended to decrease as irregularity increased. For medium-rise structures, the drift concentration factors(DCFs) for SCED systems were lower than those for BRB frames. This means that SCED-braced frames deform in a more uniform manner with respect to building height. The effect of the torsional irregularity on the magnitude of the DCFs was small.

On the Design of Cantilever Type High Speed Towing Carriage with Excellent Acceleration Performance (가속성능이 우수한 외팔보형 고속예인전차의 설계)

  • Kim, Jae Sung;Kim, Hyochul
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.53 no.3
    • /
    • pp.228-236
    • /
    • 2016
  • Extraordinarily the establishment of towing tank has been initiated after the allocation of space at the basement floor of existing building through remodeling procedure. Therefore the asymmetric tank should be unavoidably determined by compromising with the allowable space and existing building structure. Consequently the shape of towing carriage ought to be selected as a cantilever type to match with the given environmental conditions. Finally the major role of the towing tank has been configured on the fundamental research work for the high speed marine vehicles. Due to the limited length of towing tank, it is appeared that the carriage should accelerated with 1.2m/sec2 which is equivalent to twice of the maximum acceleration in ordinary practices on design application of carriage. In such a condition the exerted total power of motor could not be converted to traction force of the carriage without slip for the acceleration. To overcome these difficulties the contact pressure of a horizontal traction wheel to rail has been reinforced by the elastic recovery force of springs on supporting rollers. It is believed that the design experience of the high speed towing carriage under unusual circumferential condition and acceleration barrier could be utilized not only on the design of high speed towing carriage but also on the improvement of existing facilities.

Using an appropriate rotation-based criterion to account for torsional irregularity in reinforced concrete buildings

  • Akshara S P;M Abdul Akbar;T M Madhavan Pillai;Rakesh Pasunuti;Renil Sabhadiya
    • Earthquakes and Structures
    • /
    • v.26 no.5
    • /
    • pp.349-361
    • /
    • 2024
  • Excessive torsional behaviour is one of the major reasons for failure of buildings, as inferred from past earthquakes. Numerous seismic codes across the world specify a displacement-based or drift-based criterion for classifying buildings as torsionally irregular. In recent years, quite a few researchers have pointed out some of the inherent deficiencies associated with the current codal guidelines on torsional irregularity. This short communication paper aims to envisage the need for a revision of the displacement-based guidelines on torsional irregularity, and further highlight the appropriateness of a rotation-based criterion. A set of 6 reinforced concrete building models with asymmetric shear walls are analysed using ETABS v18.0.2, by varying the number of stories from 1 to 9, and the torsional irregularity coefficient of various stories is calculated using the displacement-based formula. Since rotation about the vertical axis is a direct indication of the twist experienced by a building, the calculated torsional irregularity coefficients of all stories are compared with the corresponding floor rotations. The conflicting results obtained for the torsional irregularity coefficients are projected through five categories, namely mismatch with floor rotations, inconsistency in trend, lack of clarity in incorporation of negative values, sensitivity to low values of displacement and error conceived in the mathematical formulation. The findings indicate that the irregularity coefficient does not accurately represent the torsional behaviour of buildings in a realistic sense. The Indian seismic code-based values of 1.2 and 1.4, which are used to characterize buildings as torsionally irregular are observed to be highly sensitive to the numerical values of displacements, rather than the actual degree of rotation. The study thus emphasizes the revision of current guidelines based on a more relevant rotation-based or eccentricity-based approach.

Empirical Equations Predicting Major Parameters for Simulating Cyclic Behavior of Rectangular HSS Braces (장방형 각형강관 가새부재 이력거동 예측을 위한 주요변수의 경험식 제안)

  • Han, Sang Whan;Sung, Min Soo;Mah, Dongjun
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.21 no.3
    • /
    • pp.137-144
    • /
    • 2017
  • The cyclic behavior of braces is complex due to their asymmetric properties in tension and compression. For accurately simulating the cyclic curves of braces, it is important to predict the major parameters such as cyclic brace growth, cyclic buckling load, incidence local buckling and fracture with good precision. For a given brace, the most accurate values of these parameters can be estimated throughout experiments. However, it is almost impossible to conduct experiments whenever an analytical model has to be established for many braces in building structures due to enormous cost and time. For avoid such difficulties, empirical equations for predicting constituent parameters are proposed from regression analyses based on test results of various braces. This study focuses on rectangular hollow structural section(HSS) steel braces, which have been popularly used in construction practice owing to its sectional efficiency.