• Title/Summary/Keyword: assessment of safety

Search Result 5,533, Processing Time 0.039 seconds

Seismic Fragility Analysis based on Material Uncertainties of I-Shape Curved Steel Girder Bridge under Gyeongju Earthquake (강재 재료 불확실성을 고려한 I형 곡선 거더 교량의 경주 지진 기반 지진 취약도 분석)

  • Jeon, Juntai;Ju, Bu-Seog;Son, Ho-Young
    • Journal of the Society of Disaster Information
    • /
    • v.17 no.4
    • /
    • pp.747-754
    • /
    • 2021
  • Purpose: Seismic safety evaluation of a curved bridge must be performed since the curved bridges exhibit the complex behavior rather than the straight bridges, due to geometrical characteristics. In order to conduct the probabilistic seismic assessment of the curved bridge, Seismic fragility evaluation was performed using the uncertainty of the steel material properties of a curved bridge girde, in this study. Method: The finite element (FE) model using ABAQUS platform of the curved bridge girder was constructed, and the statistical parameters of steel materials presented in previous studies were used. 100 steel material models were sampled using the Latin Hypercube Sampling method. As an input ground motion in this study, seismic fragility evaluation was performed by the normalized scale of the Gyeongju earthquake to 0.2g, 0.5g, 0.8g, 1.2g, and 1.5g. Result: As a result of the seismic fragility evaluation of the curved girder, it was found that there was no failure up to 0.03g corresponding to the limit state of allowable stress design, but the failure was started from 0.11g associated with using limit state design. Conclusion: In this study, seismic fragility evaluation was performed considering steel materials uncertainties. Further it must be considered the seismic fragility of the curved bridge using both the uncertainties of input motions and material properties.

A Review of the Stroke Stage and Outcome Measures in Stroke Motor Sequelae Clinical Studies in Korea (뇌졸중으로 인한 운동 관련 후유증의 한의 치료 연구에서 뇌졸중 시기 및 평가 척도에 대한 국내 문헌 고찰)

  • Lee, Ji-eun;Chun, Se-eun;Jeon, Min-gyeol;Shin, Yong-jeen;Leem, Jung-tae;Shin, Sun-ho
    • The Journal of Internal Korean Medicine
    • /
    • v.43 no.4
    • /
    • pp.656-679
    • /
    • 2022
  • Objectives: The aims of this study were to evaluate the fidelity of stroke stage reporting, the timeliness of the outcome measures, and the use of the core outcome set. Methods: We searched the literature using 6 domestic databases. We selected studies that used Korean medicine interventions and targeted stroke patients with motor sequelae. We examined whether the included studies reported the stroke stage and whether they used the outcome measures in the appropriate period based on the recommendations of the "Stroke Evidence Database to Guide Effectiveness". We also confirmed the use of the essential assessment tools suggested by the core outcome set. Results: Overall, 77 studies were finally selected, with 16 (21%), 55 (71%), and 6 (8%) published on the acute, subacute, and chronic phases, respectively. Only 11 of the studies directly mentioned the stroke stage. The most commonly used assessments were the National Institutes of Health Stroke Scale, Modified Barthel Index, and Manual Muscle Testing. Only 5 studies failed to apply the stage-related outcome measures at the recommended period. The outcome variables used inadequately were the National Institutes of Health Stroke Scale, Functional Ambulation Categories, 36-Item Short Form Health Survey, and Mini-Mental State Examination. Among the core outcome set items, some studies used liver and renal function tests, but no herbal medicine safety reporting was conducted. Conclusions: In future studies, we propose to ensure accurate reporting of the stroke stage with reliable outcome measures to deliver better clinical and research outcomes. Furthermore, in future clinical studies on stroke, a standard protocol that reflects the core outcome set should be developed.

A Study for Comparison of Consequence Analysis for Buried Pipeline Considering the Depth Factor (깊이 인자를 고려한 매설배관의 사고피해영향 비교 분석에 관한 연구)

  • Han, Seung-Hoon;Seol, Ji-Woo;Yoo, Byong-Tae;Tae, Chan-Ho;Ko, Jae Wook
    • Journal of the Korean Institute of Gas
    • /
    • v.20 no.5
    • /
    • pp.9-16
    • /
    • 2016
  • Buried pipe system is subject to leak or rupture due to internal and external defects with age. Especially, if the pipeline is designed for pressurized gas, the leak can wreak a devastating on its surrounding area. The current method of setting up underground gas pipeline is based on OGP criteria of applying one tenth of the inner pipe pressure. The criteria is applied irrespective of their burial depth or pipe's properties. At times, even the whole safety measures are totally ignored. Considering the magnitude of possible damage from a gas leakage, a precise analytical tool for the risk assessment is urgently needed. The study was conducted to assess possible scenarios of gas accidents and to develop a computer model to minimize the damage. The data from ETA was analyzed intensively, and the model was developed. The model is capable of predicting jet fire influence area with comprehensive input parameters, such as burial depth. The model was calibrated and verified by the historic accident data from Edison Township, New Jersey, the United States. The statistical model was also developed to compare the results of the model in this study and the existing OGP model. They were in good agreement with respect to damage predictions, such as radiation heat coming from 10 meters away from the heat source of gas flame.

Defect Depth Measurement of Straight Pipe Specimen Using Shearography (전단간섭계를 이용한 직관시험편의 결함 깊이 측정)

  • Chang, Ho-Seob;Kim, Kyung-Suk
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.32 no.2
    • /
    • pp.170-176
    • /
    • 2012
  • In the nuclear industry, wall thinning defect of straight pipe occur the enormous loss in life evaluation and safety evaluation. To use non-destructive technique, we measure deformation, vibration, defect evaluation. But, this techniques are a weak that is the measurement of the wide area is difficult and the time is caught long. In the secondary side of nuclear power plants mostly used steel pipe, artificiality wall thinning defect make in the side and different thickness make to the each other, wall thinning defect part of deformation measure by using shearography. In addition, optical measurement through deformation, vibration, defect evaluation evaluate pipe and thickness defects of pressure vessel is to evaluate quantitatively. By shearography interferometry to measure the pipe's internal wall thinning defect and the variation of pressure use the proposed technique, the quantitative defect is to evaluate the thickness of the surplus. The amount of deformation use thickness of surplus prediction of the actual thickness defect and approximately 7 percent error by ensure reliability. According to pressure the amount of deformation and the thickness of the surplus through DB construction, nuclear power plant pipe use wall thinning part soundness evaluation. In this study, pressure vessel of thickness defect measure proposed nuclear pipe of wall thinning defect prediction and integrity assessment technology development. As a basic research defected theory and experiment, pressure vessel of advanced stability and soundness and maintainability is expected to contribute foundation establishment.

Surface Characteristics of Type II Anodized Ti-6Al-4V Alloy for Biomedical Applications

  • Lee, Su-Won;Jeong, Tae-Gon;Yang, Jae-Ung;Jeong, Jae-Yeong;Park, Gwang-Min;Jeong, Yong-Hun
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2017.05a
    • /
    • pp.77-77
    • /
    • 2017
  • Titanium and its alloys offer attractive properties in a variety of applications. These are widely used for the field of biomedical implants because of its good biocompatibility and high corrosion resistance. Titanium anodizing is often used in the metal finishing of products, especially those can be used in the medical devices with dense oxide surface. Based on SAE/AMS (Society of Automotive Engineers/Aerospace Material Specification) 2488D, it has the specification for industrial titanium anodizing that have three different types of titanium anodization as following: Type I is used as a coating for elevated temperature forming; Type II is used as an anti-galling coating without additional lubrication or as a pre-treatment for improving adherence of film lubricants; Type III is used as a treatment to produce a spectrum of surface colours on titanium. In this study, we have focused on Type II anodization for the medical (dental and orthopedic) application, the anodized surface was modified with gray color under alkaline electrolyte. The surface characteristics were analyzed with Focused Ion Beam (FIB), Scanning Electron Microscopy (SEM), surface roughness, Vickers hardness, three point bending test, biocompatibility, and corrosion (potentiodynamic) test. The Ti-6Al-4V alloy was used for specimen, the anodizing procedure was conducted in alkaline solution (NaOH based, pH>13). Applied voltage was range between 20 V to 40 V until the ampere to be zero. As results, the surface characteristics of anodic oxide layer were analyzed with SEM, the dissecting layer was fabricated with FIB method prior to analyze surface. The surface roughness was measured by arithmetic mean deviation of the roughness profile (Ra). The Vickers hardness was obtained with Vickers hardness tester, indentation was repeated for 5 times on each sample, and the three point bending property was verified by yield load values. In order to determine the corrosion resistance for the corrosion rate, the potentiodynamic test was performed for each specimen. The biological safety assessment was analyzed by cytotoxic and pyrogen test. Through FIB feature of anodic surfaces, the thickness of oxide layer was 1.1 um. The surface roughness, Vickers hardness, bending yield, and corrosion resistance of the anodized specimen were shown higher value than those of non-treated specimen. Also we could verify that there was no significant issues from cytotoxicity and pyrogen test.

  • PDF

An Assessment of the Quantitative Effect of TSS by Vessel Traffic Flow Simulation (해상교통류 시뮬레이션을 이용한 통항분리제도의 정량적 효과평가)

  • ;;;INOUE, Kinzo
    • Journal of Korean Society of Transportation
    • /
    • v.21 no.1
    • /
    • pp.41-49
    • /
    • 2003
  • Marine traffic management could be defined as the implementation of managerial technical measures to improve vessel traffic safety. The managerial elements of vessel traffic management for ports and harbours or narrow channels include the total amount of traffic control, the vessel traffic separation scheme, speed restriction, traffic control by signals, the navigation information service and so forth. This research aims to quantify how much the traffic separation schemes(TSS) contribute to the alleviation effect of ship handling difficulty and to propose a design standard when the individual management measure is applied in an actual waterway. Traffic separation schemes have now been established in most of the major routes and congested waters of the world, and the number of collisions and groundings have often been dramatically reduced. In this part, the relationship between the alleviation of ship handling difficulty and the reduction of encounter figures among ships is quantitatively clarified by applying the ES model. As results of simulation analysis, it is recognized that a traffic separation system is most effective in the case of narrow width and heavy traffic volume. The centre buoy installation reduces about 1/4 of the alleviation of ship handling difficulty, TSS establishment 1/3, and design change to one-way traffic from two-way traffic reduces 1/2.

Methodology for Quantitative Monitoring of Agricultural Worker Exposure to Pesticides (농작업자에 대한 농약 노출의 정량적 측정 방법)

  • Kim, Eun-Hye;Lee, Hye-Ri;Choi, Hoon;Moon, Joon-Kwan;Hong, Soon-Sung;Jeong, Mi-Hye;Park, Kyung-Hun;Lee, Hyo-Min;Kim, Jeong-Han
    • The Korean Journal of Pesticide Science
    • /
    • v.15 no.4
    • /
    • pp.507-528
    • /
    • 2011
  • Agricultural workers who mix/loads and spray pesticide in fields expose to pesticide through dermal and inhalation routes. In such situation, exposed amount should be measured quantitatively for reasonable risk assessment. Patch, gloves, socks and mask will be good materials for monitoring for dermal exposure while personal air monitor equipped with solid adsorbent and air pump will be a tool for inhalation exposure. For extrapolation of absorbed amount in dermal exposure matrices and of trapped amount in solid sorbent to total deraml or inhalation exposure, Korean standard body surface area and respiration rate were proposed in substitution of EPA data. Important exposure factors such as clothing and skin penetration ratio of dermal and inhalation exposure were suggested based on Spraying time for exposure monitoring must be long enough that the amount of pesticide to get absorbed/trapped in exposure matrices results in reasonable analytical value. In domestic case for the both of speed sprayer and power spray machine, spraying time of 20~40 minutes (0.1~0.2 ha) will be reasonable per single replicate before extrapolating to 4 hours a day with triplicates experiment.

Fall Risk Assessment of the Elderly living in Nursing Home (노인요양시설 거주 노인의 낙상 위험요인 조사 연구)

  • Yang, Sun-Hee;Park, Young-Hae;Cho, Hae-Sook;Baek, Hee-Chong
    • Journal of Home Health Care Nursing
    • /
    • v.12 no.2
    • /
    • pp.1-15
    • /
    • 2005
  • Purpose: This study was conducted to assess the fall risk factors. Method: The subjects were 87 persons who were older than 65 years living at 28 nursing home in Seoul and Gyunggi province. Subjects were interviewed using RAFS II for intrinsic factor and the environmental factor were assessed using a structured questionnaire from Oct. to Dec. in 2004. The data were analyzed by SPSS(ver. 12.0) programs, using descriptive statistics, $x^2$-test, and t-test. Result: The 37.9% of the subjects experienced the fall, and its average number is $1.94\pm1.75$. The Women's experience of the fall was higher than that of the men, but it was no significant difference with gender. There was no significant difference with the age and duration of living. The mean of the intrinsic risk factor was 13.38 in total score 39 points marks on the RAFS II scales. The intrinsic risk factor score of the fallen group 15.71 was significantly higher than the non-fallen group 12.10. The variables of recent fall experience(t=4.72, p=0.000) and urinary dysfunction(t=2.64, p=0.010) was significantly higher than the non-fallen group. The highest variable of the intrinsic factor was the age and the variables of drug intake, balance, chronic disease, recent fall experience, urinary dysfunction were followed in order. The mean of the environmental risk factor was 0.24 points. No significant differences were shown in environmental risk factor between the fallen and the non-fallen groups. To the fallen group, the place of entrance was the highest risky environmental factor. To see in area dimension, the floor surfaces was the highest risky environmental factor and equipment and illumination factor was the following risky elements in order. In the total score of environmental risk factors based on the ares, the fallen group was 0.26 and the non-fallen group was 0.24, but there were no significant differences between the groups. Conclusion: This results suggested that visual protection strategy, set up the safety device in the place of entrance and inner stairway, bathroom and nonskid mat in the nursing home would be contribute to the prevention of the fall for the elderly.

  • PDF

Youth Risk Behavior Survey of Middle School Students in Daegu Metropolitan City (대구시 일부지역 중학생들의 건강관련 위험행동과 관련요인조사)

  • 이중정;이충원
    • Korean Journal of Health Education and Promotion
    • /
    • v.19 no.3
    • /
    • pp.51-72
    • /
    • 2002
  • This research was conducted to understand and analyze the health-related behaviors of middle school students and get fundamental research data essential to provide efficient student guidance and public health service at school. The interview using Youth Risk Behavior Surveillance System(YRBSS). Translation and modification for Korean students of the YRBS. The Korean version of YRBS(Youth Risk Behavior Surveillance System) that translation and modification for Korean students of the YRBS developed by the Centers for Disease Control and Prevention(CDC)was used to assessment to health-related behaviors of youth. The interviewees were 1040 enrolled students at middle school in Daegu metropolitan city. YRBSS monitors six categories of priority health behaviors among youth and young adults behaviors that contribute to unintentional and intentional injuries; tobacco use; alcohol and other drug use, sexual behaviors that contribute to unintended pregnancy and sexually transmitted diseases(STDs)(including human immunodeficiency virus infection); unhealthy dietary behaviors; and physical activity. The result shows that over 30% of students rarely or never used safety belt and almost students were rarely or never wore a bicycle helmet. During the 12 months preceding the survey, 21.9% female students had felt so sad or hopeless almost every day for $\geq$ 2weeks in a row that they stopped doing some usually activities 20.5% of male middle school students have ever tried cigarette smoking. 26.2% of male students and 27.2% do female students had had over one drinks of alcohol during their lifetime(lifetime alcohol use). 47% of male students had had over one drinks of alcohol on $\geq$ 1 of the 30 days preceding the survey(current alcohol use). Over one half of female student were thought they were overweight. These results suggest that some risk behaviors be very prevalent in a korean middle school students and priority health-risk behaviors, which contribute to the leading cause of mortality and morbidity among youth and adult, often are establish during middle school age, extend into adulthood, are interrelated. Among both children and adults, the leading causes of death are closely linked to these behaviors. Among adults, chronic diseases such as cardiovascular disease, cancer, and diabetes are the national leading killers. Practicing healthy behaviors, such as eating low-fat, high-fruit-and-vegetable diets, getting regular physical activity, and refraining from tobacco use, would prevent many premature deaths. Because health-related behaviors are usually established in childhood, positive choices need to be promoted before damaging behaviors are initiated or become ingrained.

Influence of Punch Velocity on Gas Hydrogen Embrittlement Behaviors in SA372 Steel (압력용기용 강의 가스수소 취화 거동에 미치는 펀치속도의 영향)

  • Bae, Kyung-Oh;Shin, Hyung-Seop;Baek, Un-Bong;Nahm, Seung-Hoon;Park, Jong-Seo;Lee, Hae-Moo
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.37 no.12
    • /
    • pp.1497-1502
    • /
    • 2013
  • When using hydrogen gas as an ecofriendly energy sources, it is necessary to conduct a safety assessment and ensure thereliability of the hydrogen pressure vessel against hydrogen embrittlement expected in the steel materials. In this study, by applying the in-situ SP test method, the gas hydrogen embrittlement behaviors in SA372 steel, which is commonly used as a pressurized hydrogen gas storage container, were evaluated. To investigate the hydrogen embrittlement behavior, SP tests at different punch velocities were conducted for specimens with differently fabricated surfaces at atmospheric pressure and under high-pressure hydrogen gas conditions. As a result, the SA372 steel showed significant hydrogen embrittlement under pressurized hydrogen gas conditions. The effect of punch velocity on the hydrogen embrittlement appeared clearly; the lower punch velocity case indicated significant hydrogen embrittlement resulting in lower SP energy. The fractographic morphologies observed after SP test also revealed the hydrogen embrittlement behavior corresponding to the punch velocity adopted. Under this pressurized gas hydrogen test condition, the influence of specimen surface condition on the extent of hydrogen embrittlement could not be determined clearly.