Quantitative Assessment of the Radiation Exposure during Pathologic Process in the Sentinel Iymph Node Biopsy using Radioactive Colloid (방사성 콜로이드를 이용한 감시림프절 생검 병리처리과정에서 방사선 피폭의 정량적 평가)

  • Song, Yoo-Sung;Lee, Jeong-Won;Lee, Ho-Young;Kim, Seok-Ki;Kang, Keon-Wook;Kook, Myeong-Cherl;Park, Weon-Seo;Lee, Geon-Kook;Hong, Eun-Kyung;Lee, Eun-Sook
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.41 no.4
    • /
    • pp.309-316
    • /
    • 2007
  • Purpose: Sentinel lymph node biopsy became the standard procedure in early breast cancer surgery. Faculty members might be exposed to a trace amount of radiation. The aim of this study is to quantify the radiation exposure and verify the safety of the procedure and the facilities, especially during pathologic process. Materials and Methods: Sentinel lymph node biopsies with Tc-99m human serum albumin were performed as routine clinical work. Exposed radiation doses were measured in pathologic technologist, nuclear medicine technologist, and nuclear medicine physician using a thermoluminescence dosimeter (TLD) during one month. We also measured the residual radioactivities or absorbed dose rates, the exposure distance and time during procedure, the radiation dose of the waste and the ambient equivalent dose of the pathology laboratory. Results: Actual exposed doses were 0.21 and 0.85 (uSv/study) for the whole body and hand of pathology technologist after 47 sentinel node pathologic preparations were performed. Whole body exposed doses of nuclear medicine physician and technologist were 0.2 and 2.3 (uSv/study). According to this data and the exposure threshold of the general population (1 mSv), at least 1100 studies were allowed in pathology technologist. The calculated exposed dose rates (${\mu}$ Sv/study) from residual radioactivities data were 2.47/ 22.4 ${\mu}$ Sv (whole body/hand) for the surgeon; 0.22/ 0 ${\mu}$ Sv for operation nurse. The ambient equivalent dose of the pathology laboratory was 0.02-0.03 mR/hr. The radiation dose of the waste was less than 100 Bq/g and nearly was not detected. Conclusion: Pathologic procedure relating sentinel lymph node biopsy using radioactive colloid is safe in terms of the radiation safety.(Nucl Med Mol Imaging 2007;41(4);309-316)

Assessment on HACCP Recognition & Sanitary Management of the Industry Foodservice Manager in Seoul (식품 위해 요소 중점 관리 기준에 대한 서울 지역 사업체 급식 관리자의 위생관리평가)

  • 이헌옥;심재영;김영경;조민호;최호순;엄애선
    • Korean journal of food and cookery science
    • /
    • v.17 no.6
    • /
    • pp.542-548
    • /
    • 2001
  • Hazard Analysis Critical Control Point(HACCP) is becoming an important component of food safety worldwide. The aim of this study was to investigate comprehensively the education and knowledge level of food service managers on HACCP as well as applying HACCP system to industrial foodservice. Total 247 foodservice managers participated in the survey and 159 responses were used for analysis. The results were as follows: 1) 89% of foodservice managers were educated about HACCP, and 40.9% felt they did fully understand HACCP and 47.8% did half. 2) The score for the implementation of HACCP was in the order of apparatus and facility sanitation, personal sanitation, and time-temperature/etc. sanitation. 3) Foodservice managers who were taught HACCP kept a deep attention to food and personal sanitation, compared with those without education(p<0.05). However, the education time on HACCP affected conducting safety management. The results suggest that education and understanding of HACCP are positively related, and understanding of HACCP has a positive influence on conducting safety management.

  • PDF

Comparison Study on Efficacies of Disinfectants and Sanitizers Among Methods for Quantitative Surface Test (살균소독제의 정량적 표면시험방법별 유효성 비교)

  • Kim, Ae-Young;Kim, Yong-Su;Ha, Sang-Do
    • Journal of Food Hygiene and Safety
    • /
    • v.25 no.3
    • /
    • pp.238-244
    • /
    • 2010
  • Currently, in vitro suspension tests using tubes are used as a authorized test method for sanitizers and disinfectants. However, the methods could not accurately assess the efficacy of sanitizers and disinfectant on the food-contacted surfaces in the field. This study evaluated the effectiveness of 5 kinds of representative sanitizers and disinfectants against E. coli and S. aureus to compare three quantitative surface testing methods that have been internationally standardized. As a result, the ASTM E2111-05 (ASTM(1)) test method obtained 5.18 $\pm$ 0.03 and 5.27 $\pm$ 0.04 log cfu/carrier reduction in dealing with E. coli and S. aureus, respectively, the ASTM E2197-02 (ASTM(2)) test method obtained 4.63 $\pm$ 0.04 and 3.97 $\pm$ 0.03 log cfu/carrier reduction and the CEN EN 13697 test method should 6.14 $\pm$ 0.05 and 5.31 $\pm$ 0.10 log cfu/carrier reduction in clean condition (CEN(1)) but 4.37 $\pm$ 0.02 and 4.06 $\pm$ 0.01 log cfu/carrier reduction in dirty condition (CEN(2)). Among them, CEN(1) showed the highest bactericidal effects, whereas ASTM(2) and CEN(2) revealed low performance (p < 0.05). In conclusion, the bactericidal effects of the ASTM(2) method and the CEN EN 13697 method adopting stainless steel were lower than the ASTM(1) method, which uses glass. The effectiveness assessment results among nationally accredited test methods were different each other. This implies that they could not fit for in the accurate evaluation of sanitization and disinfection on food-contact surfaces in practical food-processing fields. These results could be used as a basic data for establishment of an official surface test methods applicable in the field.

The Content and Risk Assessment of Heavy Metals in Herbal Pills (유통 환제의 유해 중금속 함량 및 위해도 평가)

  • Lee, Sung-Deuk;Lee, Young-Ki;Kim, Moo-Sang;Park, Seok-Ki;Kim, Yeon-Sun;Chae, Young-Zoo
    • Journal of Food Hygiene and Safety
    • /
    • v.27 no.4
    • /
    • pp.375-387
    • /
    • 2012
  • The objective of this study is investigation of contamination levels and assessment of health risk effects of heavy metals in herbal pills. 31 Items and 93 samples were obtained for this investigation from major herbal medicine producing areas, herbal markets and on-line supermarkets from Jan to Jun in 2010. Inductively coupled plasma mass spectrometer method was conducted for the quantitative analysis of Pb, Cd and As. In addition, the mercury analyzer system was conducted for that of Hg without sample digestion. The average contents of heavy metals in samples were as follows : 0.87 mg/kg for Pb, 0.08 mg/kg for Cd, 2.87 mg/kg for As and 0.16 mg/kg for Hg, respectively. In addition, the average contents of heavy metals in different parts of plants, including cortex, fructus, herba, radix, seed, algae and others were 0.63 mg/kg, 3.94 mg/kg, 1.42 mg/kg, 1.05 mg/kg, 0.16 mg/kg, 22.31 mg/kg and 10.17 mg/kg, respectively. After the estimations of dietary exposure, the acceptable daily intake (ADI), the average daily dose (ADD), the provisional tolerable weekly intake (PTWI) and the relative hazard of heavy metals were evaluated. As the results, the relative hazards compared to PTWI in samples were below the recommended standard of JECFA as Pb 3.1%, Cd 0.9%, Hg 0.5%. Cancer risks through slope factor (SF) by Ministry of Environment Republic Korea and Environmental Protection Agency was $4.24{\times}10^{-7}$ for Pb and $3.38{\times}10^{-4}$ for As (assuming that the total arsenic content was equal to the inorganic arsenic). Based on our results, possible Pb-induced cancer risks in herbal pills according to parts used including cortex, fructus, herba, radix, seed, algae and others were $1.95{\times}10^{-7}$, $1.45{\times}10^{-6}$, $2.14{\times}10^{-7}$, $6.27{\times}10^{-7}$, $1.99{\times}10^{-8}$, $3.61{\times}10^{-7}$ and $9.64{\times}10^{-8}$, respectively. Possible As-induced cancer risks in herbal pills by parts used including cortex, fructus, herba, radix, seed, algae and others were $1.54{\times}10^{-5}$, $7.24{\times}10^{-5}$, $1.23{\times}10^{-4}$, $2.02{\times}10^{-5}$, $3.25{\times}10^{-6}$, $2.18{\times}10^{-3}$ and $5.67{\times}10^{-6}$ respectively. Taken together, these results indicate that the majority of samples except for some samples with relative high contents of heavy metals were safe.

Cloning of Farm Animals in Japan; The Present and the Future

  • Shioya, Yasuo
    • Proceedings of the Korean Society of Developmental Biology Conference
    • /
    • 2001.10a
    • /
    • pp.37-43
    • /
    • 2001
  • 1. About fifty thousand of cattle embryos were transferred and 16000 ET-calves were born in 1999. Eighty percents of embryos were collected from Japanese Black beef donors and transferred to dairy Holstein heifers and cows. Since 1985, we have achieved in bovine in vitro fertilization using immature oocytes collected from ovaries of slaughterhouse. Now over 8000 embryos fertilized by Japanese Black bull, as Kitaguni 7~8 or Mitsufuku, famousbulls as high marbling score of progeny tests were sold to dairy farmers and transferred to their dairy cattle every year. 2. Embryo splitting for identical twins is demonstrated an useful tool to supply a bull for semen collection and a steer for beef performance test. According to the data of Dr. Hashiyada(2001), 296 pairs of split-half embryos were transferred to recipients and 98 gave births of 112 calves (23 pairs of identical twins and 66 singletons). 3. A blastomere-nuclear-transferred cloned calf was born in 1990 by a joint research with Drs. Tsunoda, National Institute of Animal Industry (NIAI) and Ushijima, Chiba Prefectural Farm Animal Center. The fruits of this technology were applied to the production of a calf from a cell of long-term-cultured inner cell mass (1988, Itoh et al, ZEN-NOH Central Research Institute for Feed and Livestock) and a cloned calf from three-successive-cloning (1997, Tsunoda et al.). According to the survey of MAFF of Japan, over 500 calves were born until this year and a glaf of them were already brought to the market for beef. 4. After the report of "Dolly", in February 1997, the first somatic cell clone female calves were born in July 1998 as the fruits of the joint research organized by Dr. Tsunoda in Kinki University (Kato et al, 2000). The male calves were born in August and September 1998 by the collaboration with NIAI and Kagoshima Prefecture. Then 244 calves, four pigs and a kid of goat were now born in 36 institutes of Japan. 5. Somatic cell cloning in farm animal production will bring us as effective reproductive method of elite-dairy- cows, super-cows and excellent bulls. The effect of making copy farm animal is also related to the reservation of genetic resources and re-creation of a male bull from a castrated steer of excellent marbling beef. Cloning of genetically modified animals is most promising to making pig organs transplant to people and providing protein drugs in milk of pig, goat and cattle. 6. Farm animal cloning is one of the most dreamful technologies of 21th century. It is necessary to develop this technology more efficient and stable as realistic technology of the farm animal production. We are making researches related to the best condition of donor cells for high productivity of cloning, genetic analysis of cloned animals, growth and performance abilities of clone cattle and pathological and genetical analysis of high rates of abortion and stillbirth of clone calves (about 30% of periparutum mortality). 7. It is requested in the report of Ministry of Health, labor and Welfare to make clear that carbon-copy cattle(somatic cell clone cattle) are safe and heathy for a commercial market since the somatic cell cloning is a completely new technology. Fattened beef steers (well-proved normal growth) and milking cows(shown a good fertility) are now provided for the assessment of food safety.

  • PDF

COMPARISON OF TRAMADOL/ACETAMINOPHEN AND CODEINE/ACETAMINOPHEN/IBUPROFEN IN ONSET OF ANALGESIA AND ANALGESIC EFFICACY FOR POSTOPERATIVE ACUTE PAIN (수술후 급성 동통에 대한 Tramadol/Acetaminophen과 Codeine/Acetaminophen/Ibuprofen의 효과 발현시점과 진통효과의 비교)

  • Jung, Young-Soo;Kim, Dong-Kee;Kim, Moon-Key;Kim, Hyung-Jun;Cha, In-Ho;Han, Moo-Young;Lee, Eui-Wung
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.30 no.2
    • /
    • pp.143-149
    • /
    • 2004
  • Background: Some clinical trials have reported that a new analgesic combination of tramadol and acetaminophen provides good efficacy in various pain models. For the more clinical uses of this agent, comparisons about the onset of analgesia and analgesic efficacy in the acute state of pain with the other drugs known as strong analgesics were needed. Purpose: The goal of this study was to compare the times to onset of analgesia and the other analgesic efficacy of 75 mg tramadol/650 mg acetaminophen and 20 mg codeine/500 mg acetaminophen/400 mg ibuprofen in the treatment of acute pain after oral surgery. Patients and Methods: Using a randomized, single-dose, parallel-group, single-center, and active-controlled test design, this clinical study compared the times to onset of analgesia using a two-stopwatch technique and the other analgesic efficacy of the single-dose tramadol/acetaminophen and codeine/acetaminophen/ibuprofen. These were assessed in 128 healthy subjects with pain from oral surgical procedures involving extraction of one or more impacted third molars requiring bone removal. From the time of pain development, the times to onset of perceptible and meaningful pain relief, pain intensity, pain relief, an overall assessment, and adverse events of the study medications were recorded for 6 hours. Results: The demographic distribution and baseline pain data in the two groups were statistically similar. The median times to onset of perceptible pain relief were 21.0 and 24.4 minutes in the tramadol/acetaminophen and codeine/acetaminophen/ibuprofen groups respectively and those to onset of meaningful pain relief were 56.4 and 57.3 minutes, which were statistically similar. The other efficacy variables such as mean total pain relief (TOTPAR) and the sum of pain intensity differences (SPID) were also similar in the early period after pain development and drug dosing. The safety of tramadol/acetaminophen was well tolerated and very comparable to that of codeine/acetaminophen/ibuprofen. Conclusions: In this acute dental pain model, the onset of analgesia and analgesic efficacy of tramadol/acetaminophen was comparable to that of codeine/acetaminophen/ibuprofen. These results showed that tramadol/acetaminophen was recommendable for fast and effective treatment in the management of postoperative acute pain.

A STUDY ON GEOMETRIC COMPARISON OF FOUR INTERCHANGEABLE IMPLANT PROSTHETIC RETAINING SCREWS AND MEASUREMENT OF LOOSENING TORGUE (호환 가능한 임플랜트 보철용 유지 나사들의 형태 비교와 풀림 회전력의 측정에 관한 연구)

  • Cho, Su-Mi;Lim, Ju-Hwan;Cho, In-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.36 no.3
    • /
    • pp.468-482
    • /
    • 1998
  • Since the concept of osseointegration was introduced by Branemark of Sweden, dental implants have been used for various dental prosthetic treatments. The survival rate of dental implant is likely to be closely related to the total biomechanical role of each component of implant system. The use of interchangeable component is very attractive for dental practitioners because such an approach would save treatment cost, flexibility of prosthetic treatment options as well as conveniences. Therefore, the use of interchangeable implant system has been increasing without scientific assessment of safety and efficacy of various interchangeable implant system. The purpose of this study, therefore, were to compare the geometric characteristic of four interchangeable dental implant screws and the loosening torque of these screws. Four types of dental implant screws tested in this study were Nobelpharma, 3i, Impla-med, Restore. Four screws each of the test specimens were subjected for scanning electron microscopic examinations under the same condition and a 35x magnified standard SEM picture was objected from each test specimen using JSM-5200 scanning microscope. From each of the SEM pictures, eight parameters. i.e., diameter of screw head. screw length, thread pitch, major diameter. neck diameter, neck length, crest width and root width were determined using a caliper. The measurement for each parameters were then corrected for their magnification factor. The loosening torque were also determined by using a torque gauge. All of the measurements were statistically analyzed by ANOVA test and multiple range test. Statistical significance was set in advance at the probability level of less than 0.05. All analyses were done with SPSS software for the personal computer. The conclusion obtained from this studies were summarized as the following; 1. No statistically significances were noted in the thread pitch. and crest width in the four screws, and in the case of major diameter, the Impla-med screw was significantly smaller than the other three screws (p<0.05). Therefore, four implant bolts could be physically inserted in a abutment nuts. 2. The diameter of screw head was decreased in the order of Restore, 3i, Nobelpharma, Impla-med screws and the length of screws were decreased in the order of 3i, Restore, Nobelpharma and Impla-med. The diameter of neck was decreased in the order of Impla-med, Restore. Nobelpharma, 3i screws. The differences of each of these parameters were statistically significant (p<0.05). The width of root of screws were decreased in the order of Nobelpharma, Impla-med, Restore and 3i. The differences among Nobelpharma and Impla-med. Restore and 3i were statistically significant (p<0.05). 3. When the screws were loosening 1, 3, 4 and 5 times, the loosening torque for Impla-med and 3i screws were significantly higher than that of Nobelpharma or Restore screws (p<0.05). However, when statistically smaller than that of 3i, Restore or Nobelpharma screws(p<0.05).

  • PDF

Change of Fractured Rock Permeability due to Thermo-Mechanical Loading of a Deep Geological Repository for Nuclear Waste - a Study on a Candidate Site in Forsmark, Sweden

  • Min, Ki-Bok;Stephansson, Ove
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2009.06a
    • /
    • pp.187-187
    • /
    • 2009
  • Opening of fractures induced by shear dilation or normal deformation can be a significant source of fracture permeability change in fractured rock, which is important for the performance assessment of geological repositories for spent nuclear fuel. As the repository generates heat and later cools the fluid-carrying ability of the rocks becomes a dynamic variable during the lifespan of the repository. Heating causes expansion of the rock close to the repository and, at the same time, contraction close to the surface. During the cooling phase of the repository, the opposite takes place. Heating and cooling together with the, virgin stress can induce shear dilation of fractures and deformation zones and change the flow field around the repository. The objectives of this work are to examine the contribution of thermal stress to the shear slip of fracture in mid- and far-field around a KBS-3 type of repository and to investigate the effect of evolution of stress on the rock mass permeability. In the first part of this study, zones of fracture shear slip were examined by conducting a three-dimensional, thermo-mechanical analysis of a spent fuel repository model in the size of 2 km $\times$ 2 km $\times$ 800 m. Stress evolutions of importance for fracture shear slip are: (1) comparatively high horizontal compressive thermal stress at the repository level, (2) generation of vertical tensile thermal stress right above the repository, (3) horizontal tensile stress near the surface, which can induce tensile failure, and generation of shear stresses at the comers of the repository. In the second part of the study, fracture data from Forsmark, Sweden is used to establish fracture network models (DFN). Stress paths obtained from the thermo-mechanical analysis were used as boundary conditions in DFN-DEM (Discrete Element Method) analysis of six DFN models at the repository level. Increases of permeability up to a factor of four were observed during thermal loading history and shear dilation of fractures was not recovered after cooling of the repository. An understanding of the stress path and potential areas of slip induced shear dilation and related permeability changes during the lifetime of a repository for spent nuclear fuel is of utmost importance for analysing long-term safety. The result of this study will assist in identifying critical areas around a repository where fracture shear slip is likely to develop. The presentation also includes a brief introduction to the ongoing site investigation on two candidate sites for geological repository in Sweden.

  • PDF

Optimal Duration of Dual Antiplatelet Therapy after Stent-Assisted Coil Embolization of Unruptured Intracranial Aneurysms : A Prospective Randomized Multicenter Trial

  • Ban, Seung Pil;Kwon, O-Ki;Kim, Young Deok;Kim, Bum-Tae;Oh, Jae Sang;Kim, Kang Min;Kim, Chang Hyeun;Kim, Chang-Hyun;Choi, Jai Ho;Kim, Young Woo;Lim, Yong Cheol;Byoun, Hyoung Soo;Park, Sukh Que;Chung, Joonho;Park, Keun Young;Park, Jung Cheol;Kwon, Hyon-Jo;Korean NeuroEndovascular Society,
    • Journal of Korean Neurosurgical Society
    • /
    • v.65 no.6
    • /
    • pp.765-771
    • /
    • 2022
  • Objective : Stent-assisted coil embolization (SAC) has been increasingly used to treat various types of intracranial aneurysms. Delayed thromboembolic complications are major concerns regarding this procedure, so dual antiplatelet therapy with aspirin and clopidogrel is needed. However, clinicians vary the duration of dual antiplatelet therapy after SAC, and no randomized study has been performed. This study aims to compare the safety and efficacy of long-term (12 months) dual antiplatelet therapy and short-term dual antiplatelet therapy (6 months) after SAC for patients with unruptured intracranial aneurysms (UIAs). Methods : This is a prospective, randomized and multicenter trial to investigate the optimal duration of dual antiplatelet therapy after SAC in patients with UIAs. Subjects will receive dual antiplatelet therapy for 6 months (short-term group) or 12 months (long-term group) after SAC. The primary endpoint is the assessment of thromboembolic complications between 1 and 18 months after SAC. We will enroll 528 subjects (264 subjects in each group) and perform 1 : 1 randomization. This study will involve 14 top-performing, high-volume Korean institutions specializing in coil embolization. Results : The trial will begin enrollment in 2022, and clinical data will be available after enrollment and follow-up. Conclusion : This article describes that the aim of this prospective randomized multicenter trial is to compare the effect of short-term (6 months) and long-term (12 months) dual antiplatelet therapy on UIAs in patients undergoing SAC, and to find the optimal duration.

Assessment of Airborne Welding Fume Concentration for Some Manufacturing Industries in Busan

  • Cha, Min-Ho;Kim, Jeong-Won;Kim, Jong-Eun;Cho, Young-Ha;Moon, Deog-Hwan
    • Journal of Environmental Health Sciences
    • /
    • v.33 no.6
    • /
    • pp.506-512
    • /
    • 2007
  • This study was conducted to describe the exposure levels of welding fumes by the type of manufacturers, work process, welding type and the size of manufacturers, and to find out the trend of chronological changes of airborne welding fume levels. The subjects of this study were 509 manufacturers, consisting of 11 types of manufacturers, 3 work processes, 7 welding types, in Busan from January, 1997 to December, 2005. Airborne concentration of welding fume was determined by manual of National Institute for Occupational Safety and Health (NIOSH), and the data were analyzed by using SPSS 10.0 for Windows program. The mean concentration of airborne welding fume in all manufacturers was $1.29\;mg/m^3$ (Range: $0.01{\sim}3.00\;mg/m^3)$. The level of welding fume was the highest, as $1.96\;mg/m^3$, for manufactures of motor vehicles, trailers and semi-trailers, which was lower than $5.0\;mg/m^3$ of 8 hr-TWA in Korean permissible exposure limit for welding fume. There was a significant difference in the mean levels of welding fumes by work process, showing the highest in welding workshop ($1.39\;mg/m^3$), followed by pipeline welding workshop ($1.26\;mg/m^3$) and engineering workshop ($1.20\;mg/m^3$). Among welding types, the mean level of welding fume was the highest in the type of $CO_2$ & arc welding, as $1.46\;mg/m^3$, followed by $CO_2$ welding ($1.40\;mg/m^3$), shielded metal arc welding ($1.31\;mg/m^3$), spot welding ($1.27\;mg/m^3$), and so on. The highest mean level of welding fume was $1.58\;mg/m^3$ in work process of pipe line welding workshop for the manufacturers of basic iron and steel, and $2.27\;mg/m^3$ in the type of arc welding for the manufactures building ship and boats. By the size of manufacturers, the mean concentration of welding fume for manufactures in small scale with less than 50 workers was the highest as $1.45\;mg/m^3$ (Range: $0.07{\sim}3.00\;mg/m^3)$. The mean level of welding fume was the highest as $1.39\;mg/m^3$ both in 1997 and in 2005, showing a trend of fluctuating periodically within a range of $1.10{\sim}1.39\;mg/m^3$. The above results suggested that more effective control program for work environment producing welding fumes should be developed and applied since there were significant variations in welding fume levels by the type of manufacturers, work processes, welding types, the size of manufactures, and by year.