• Title/Summary/Keyword: assessment of safety

Search Result 5,533, Processing Time 0.037 seconds

Static Test and Suggestion of Shear Strength Equation on Shear Studs in Composite Bridge (합성형 교량에서 전단연결재에 대한 정적실험 및 강도식의 제안)

  • Yi, Seong-Tae
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.22 no.2
    • /
    • pp.43-50
    • /
    • 2018
  • In this study, to investigate the shear connection material for the composite of steel plate and bottom plate, design standards and research cases for shear connectors in various countries around the world were analyzed and shear tests were performed on the Push-out specimens with a shear connection, which transmits the horizontal shear force developed on the contact surface between the steel plate and the concrete slab due to various vertical loads acting on the bridge deck. Through Push-out tests of shear studs, of which FRP bar instead reinforcement is placed, the shear stud evaluation formula of the steel strap bottom plate was suggested. The suggested equation suggested in this study has the safety factor of approximately three times compared to allowable strength of highway bridge design criteria. In addition, compared to existing DIN standards and Viest assessment equation, the results showed similar values(approximately, 5% error).

Development of Recombinant Human Growth Hormone in Yeast: Efficacy Evaluation and Safety Assessment (Human growth hormone의 개발과 이에 따른 효능 및 안전성 평가)

  • Lee Sangkyun;Park Soon Jae
    • Proceedings of the Korean Society of Toxicology Conference
    • /
    • 1997.10a
    • /
    • pp.38-42
    • /
    • 1997
  • Human growth hormone is known as one of the peptide hormones which is consisted of 191 amino acids derived from the pituitary gland in humans. The objectives of this study were to supply inexpensive recombinant methionyl human growth hormones (rHGH) synthesized by the DNA technology in a yeast cell line and followed by the establishement of protein purification techniques. The next steps of the research were to study its physic-chemical properties and biological properties, and to evaluate various preclinical aspcts including pharmacokinetics sutdy, general pharmacology study, general toxicity test, and specific toxicity tests. Clinical phase I, II, III studies were also done against growth hormone dficient children to reveal that growth promoting effects were similar compared with the natural HGH extracted from pituitary glands and commercially available rHGHs. The results could be summarized that (I) this yeast dervied rHGH have had excellent physico-chemical and biological properties in comparison with a natural HGH and other synthesized rHGHs, (2) we could not see any toxic side effects when very high doses were administered to the experimental animals, and (3) this growth hormone showed effectiveness in the growth stimulating to growth hormone deficient patients.

  • PDF

A Study on the Development of Calculation Tables and Formulas for Determining Separation Distance in Case of Cl2・HF Tank-lorry Leakage (염소・불화수소 탱크로리 누출사고 시 이격거리 산정을 위한 산정표 및 산정식 개발 연구)

  • Jeon, Byeong-Han;Kim, Hyun-Sub;Lim, Sang-Min;Lee, Joo-Chan;Lee, Gang-San
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.4
    • /
    • pp.212-219
    • /
    • 2021
  • Chemical accidents caused by transport vehicles account for 20% of all chemical accidents every year, but there are difficulties in the accident-response process due to repeated situations where the impact assessment information is unknown. In this study, we developed a calculation table and formula for predicting the range of damage for chlorine and hydrogen fluoride, which have a high domestic usage, high risk of accidents, and high accident frequency in the last 7 years. The calculation table is based on the leakage rate, wind speed, and temperature, and the calculation formula was derived using R software for special situations where it is difficult to apply the calculation table. The calculation table and formula could be used on site by related organizations to obtain important information for decision making, which could help in minimizing damage from chemical accidents, setting separation distances, and deciding to evacuate residents.

Decision technique for accommodation facilities of multi-utility tunnel in basic planning phase (기본 계획 단계에서의 공동구 수용시설물 결정 기법)

  • Oh, Won-Joon;Jin, Kyu-Nam;Kang, Yeong-Ku;Cho, Choong-Yeun;Sim, Young-Jong
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.21 no.1
    • /
    • pp.79-92
    • /
    • 2019
  • In this paper, we propose a method to determine whether to install the accommodation facility of the multi-utility tunnel more effectively in the basic planning phase, and to set up an evaluation system to determine the configuration and kind of accommodation facility. For the configuration of the accommodation facility, 98 alternatives were analyzed for 7 accommodation facility. For the evaluation system of the accommodation facility, index related to feasibility and economic in basic planning phase were selected. The evaluation system classified as spatial, effective, and cost evaluation was presented reflecting the selected index, and AHP analysis was performed for weight setting. The results of this study will be helpful for users including designers to shorten the time and increase the efficiency in the process of determining accommodation facility of the multi-utility tunnel in basic planning phase.

A Study on the Quality Control Method for Geotechnical Information Using AI (AI를 이용한 지반정보 품질관리 방안에 관한 연구)

  • Park, Ka-Hyun;Kim, Jongkwan;Lee, Seokhyung;Kim, Min-Ki;Lee, Kyung-Ryoon;Han, Jin-Tae
    • Journal of the Korean Geotechnical Society
    • /
    • v.38 no.11
    • /
    • pp.87-95
    • /
    • 2022
  • The geotechnical information constructed in the National Geotechnical Information DB System has been extensively used in design, construction, underground safety management, and disaster assessment. However, it is necessary to refine the geotechnical information because it has nearly 300,000 established cases containing a lot of missing or incorrect information. This research proposes a method for automatic quality control of geotechnical information using a fully connected neural network. Significantly, the anomalies in geotechnical information were detected using a database combining the standard penetration test results and strata information of Seoul. Consequently, the misclassification rate for the verification data is confirmed as 5.4%. Overall, the studied algorithm is expected to detect outliers of geotechnical information effectively.

Residual Seismic Capacity Evaluation of RC Frames with URM Infill Wall Based on Residual Crack Width and Damage Class (잔류균열폭 및 손상도에 기초한 무보강 조적벽체를 갖는 RC 골조의 잔존내진성능 평가)

  • Choi, Ho
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.13 no.5
    • /
    • pp.41-50
    • /
    • 2009
  • Following an earthquake, the major concerns for damaged buildings are their safety/risk in the event of aftershocks, and thus a quantitative damage assessment must be performed in order to evaluate their residual seismic capacity and to identify necessary actions for the damaged buildings. Post-event damage evaluation is therefore as essential for the quick recovery of a damaged community as pre-event seismic evaluation and strengthening of vulnerable buildings. The objective of this study is to develop a post-earthquake seismic evaluation method for RC frames with URM infill wall for typical school buildings. For this purpose, full-scale, one-bay, single-story specimens having different axial loads in columns are tested under cyclic loadings. During the tests, residual crack widths, which can also be found in damaged buildings, are measured in order to estimate the residual seismic capacity from the observed damage. In this paper, the relationship between the measured residual crack width and the residual seismic capacity is discussed analytically and experimentally, and reduction factors are proposed to estimate the residual seismic capacity based on the observed damage level.

Application of ecosystem modeling for the assessment of water quality in an eutrophic marine environment; Jinhae Bay (부영양화된 해양환경의 수질개선을 위한 해양생태계모델링의 적용 ; 한국의 진해만)

  • Lee, Won-Chan;Park, Sung-Eun;Hong, Sok-Jin;Oh, Hyun-Taik;Jung, Rea-Hong;Koo, Jun-Ho
    • Proceedings of KOSOMES biannual meeting
    • /
    • 2006.11a
    • /
    • pp.217-219
    • /
    • 2006
  • This study focused an water quality response to land-based pollution loads and the appropriate pollutant load reduction in Chinhae Bay using an eco-hydrodynamic model. Land-based discharge foam urban areas, industrial complex and sewage treatment plant was the greatest contributor to cause red-tide blooms and summer hypoxia. Tidal currents velocity af the ebb tide was about 10 cm/s stronger than that of the flood tide. A residual current was simulated to. have a slightly complicated pattern with ranging from 0.1 to. 2.7 cm/s. In Masan Bay, pollutant materials cannot flaw from the inner to the outer bay easily because af residual currents flaw southward at surface and northward at the bottom. The simulation results of COD distribution showedhigh concentrations aver 3 mg/L in the inner part of Masan Bay related pollutant discharge, and charge, and lower levels less than 1.5mg/L in the central part of Chinhae Bay. For improvement water quality in Chinhae Bay, it is necessary to reduce the organic and inorganic loads from paint sources by mare than 50% and ameliorate severe polluted sediment.

  • PDF

Quality Characteristics of Instant Coffee with Probiotics and Microground Coffee (Probiotics와 미세분쇄 원두커피가 첨가된 인스턴트 커피의 품질적 특성)

  • Ko, Bong Soo;Lim, Sang Ho;Han, Sung Hee
    • Culinary science and hospitality research
    • /
    • v.23 no.8
    • /
    • pp.153-162
    • /
    • 2017
  • Bacillus coagulans was added as probiotics in instant coffee with microground roasted coffee which is recently rising premium coffee and the instant coffee (ProBio coffee) was compared with 3 commercial instant coffees with microground roasted coffee in quality characteristics to understand the competitiveness of ProBio coffee. In sensory evaluation, ProBio coffee had inferior aroma intensity and overall acceptance compared with control group (brewed coffee) (p<0.05) but it had equal quality or more compared with 3 commercials. Total polyphenol content, chlorogenic acid content, DPPH free radical scavenging activity and caffeine content were $110.72{\pm}1.99mg/g$, $2,700{\pm}20mg/g$, $146.22{\pm}3.62TEAC\;mg/g$, $28.1{\pm}3.2ppm$ respectively. In general quality characteristics, water content, solubility, particle size and particle strength of ProBio coffee were similar to general instant coffee but had darker color than it. In safety assessment, acrylamide content was $502{\pm}10ppb$, and residual pesticides and ochratoxin A were not detected. Over 70% of B. coagulans were maintained in 4 months of storage and 16 months of shelf life was predicted in ProBio coffee by $Q_{10}$ model. Therefore, ProBio coffee was confirmed to have a sufficient product competiveness compared with 3 commercials.

Rediscovering A Path to Aging in Place: Development of Housing Cooperatives for Rural Elderly

  • Lee, Hyun-Jeong
    • Architectural research
    • /
    • v.13 no.3
    • /
    • pp.31-40
    • /
    • 2011
  • Profit-keeping behaviors naturally occur in the market to satisfy consumers, and the logic behind it lies in the economies of scale. On the flip side, some commodities transacted in the market are not available or can not be easily acquired unless the demand is high enough. Under this proposition, some consumers rise and find their own solution to meet the services at a reasonable cost or at an adequate level. The commonly adopted way is to establish a cooperative, and it stirs purchasing power by pooling resources and further bargains price and service quality. As a consumer cooperative, housing cooperatives notably found in rural towns enable the elderly to continue independent living. This study is to take a closer look at residential life of the rural elderly in housing cooperatives. Utilizing in-depth focus group interviews with 40 residents in four housing cooperatives, this qualitative research draws main factors affecting the decision to move in, residential assessment, and strengths and weakness of living in a housing cooperative. The primary factor influencing the moving decision is to continue to independent living in a familiar community, and the bottom line is planning ahead. Frailty and bereavement are found to be the leading occasions for them to move. The participants are satisfied with the independent living arrangement, and particularly, cited such features as safety and security, elderly-friendly design, common spaces, freedom, social activities and efficient living. Also, it is stated that some cooperative natures such as control over the property and giving a voice on management render positive impacts on the satisfaction with communal living. In spite of all the benefits and strengths, participants face with a public notion that an independent living arrangement like a housing cooperative has never done before in rural towns, so that most people recognize it as part of dependent living arrangements like nursing home.

Radiocarbon Dating Practices by Benzene Liquid Scintillation Method (벤젠-액체 섬광계수법에 의한 $^{14}C$ 연대측정)

  • Lee, Yeon-Gyu;Choi, Jeong-Min;Kim, Chang-Gyu
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.4 no.3
    • /
    • pp.180-187
    • /
    • 1999
  • Radiocarbon dating method using benzene liquid scintillation was performed on the oyster shell fragments which producted from the shell mounts at Hadong Mogdori in Kyeongsangnamdo. This paper described to the age dating method and compared to the result. The carbon in sample is synthesized to a benzene through the sample preparation, $SrCO_3$, $SrC_2$, $C_2H_2$ and $C_6H_6$ synthesizing process. Age dating is calculated by Wallac 1415 Liquid Scintillation Counter. The result of age dating is estimated to be $4905{\pm}112$ yr BP in Yosu Univ. which is a good agreement with the result in Shimane Univ. ($4912{\pm}123$ yr BP). Radiocarbon dating method using benzene liquid scintillation is a simple and economical in operation and establishment, it has a potential instrumentation in the university and research institute.

  • PDF